  8815   Tue Jul 9 20:09:53 2013 KojiUpdateIOOWFS debuggingThe low UGFs of the MC WFS servos made
the MC insane thesedays: 
The servos are too slow and we kept
  
  8817   Wed Jul 10 01:27:44 2013 gautamUpdateGreen LockingY-end Green PDH open-loop transfer function [Annalisa, gautam]
Summary:
We have measured the open-loop transfer
 Green_PDH_measurement.pdfY-end_Green_PDH.pdf 
  8818   Wed Jul 10 02:10:41 2013 manasaUpdateGreen LockingBeatbox gets a makeover

    

       
            
 IMG_0842.JPGIMG_0844.JPGIMG_0845.JPGIMG_0846.JPG 
  8819   Wed Jul 10 02:28:04 2013 AnnalisaUpdateGreen LockingBeat notes lost![Manasa, Jenne, Annalisa]
I was going to find the beat note
to start the cavity scan, but I couldn't.
  
  8820   Wed Jul 10 11:27:02 2013 manasaUpdateGreen LockingX arm beatnote foundI found the beat note for X arm. I did
not change anything this morning (to the
best of my knowledge). Hooking up the spectrum
  
  8821   Wed Jul 10 11:44:02 2013 AnnalisaUpdateGreen LockingY beat note found!I found the beat note for the Y arm. Nothing
was changed with respect to yesterday night,
but the beat is back!
  
  8822   Wed Jul 10 14:49:00 2013 SteveUpdateGreen Locking more fiber protective tubing layed

    

       
            
 fibreETMXprotectedendOnly.jpg 
  8824   Thu Jul 11 00:30:27 2013 manasaUpdateGreen LockingX arm ALS post-beatbox makeoverI ran a series of diagnostics on the X
arm ALS to look at how the beatbox behaves
after the makeover.
 XALS_inloop.pdfXALS_scan.pdfALS_outloop.pdf 
  8825   Thu Jul 11 03:14:19 2013 JenneUpdateLSCYarm held nicely on IR resonance with ALS, PRMI+arm attempt[Annalisa, Jenne, Nic]
After having troubles with the Xarm
earlier (maybe Manasa can write/say something
 Yarm_onIRresonance_noPRMIyet_POYcalibrated.pdf 
  8826   Thu Jul 11 07:34:42 2013 manasaUpdateLSCYarm held nicely on IR resonance with ALS, PRMI+arm attempt

    

       
            
  
  8827   Thu Jul 11 09:15:10 2013 SteveUpdateendtable upgradeETMY optable groundedETMY optical table top was grounded to
the ETMY chamber through 1 Mohms this morning.
I  also strain releifed
  
  8828   Thu Jul 11 09:24:03 2013 SteveUpdateGeneralthere should be nothing left on optable topsThere are 4 oscilloscopes left on the AP
optical table top.... It's only 25 lbs...
  
  8829   Thu Jul 11 12:00:50 2013 AlexUpdate Planned rack additions[Eric, Alex]
We mounted our Laser Module and Laser
Power Source in rack 1y1. We plan to add
 Annotated_Rack_1y1_-_update.pdf 
  8830   Thu Jul 11 13:52:51 2013 CharlesUpdateISSRMS threshold detection and triggeringThere are essentially two major portions
of the ISS I am designing. One system has
the voltage reference, differential amplifier
 40mServo_v1.pdfSimple_Comparator_Circuit.pngF0001TEK.JPG 
  8831   Thu Jul 11 14:38:38 2013 AnnalisaUpdateGreen LockingY arm cavity scanYesterday I did a cavity scan with IR while
holding the Yarm with green.
ALS
 IRlocked_res_mot_0710.pdfArmScanN5.pngCavityScanETMYmis 
  8833   Fri Jul 12 00:12:41 2013 KojiUpdateLSCPRMI + Y arm trial[Koji, Manasa, Annalisa]
I made several trials to scan the
arm on the IR TEM00 resonance while the PRMI
  
  8834   Fri Jul 12 09:00:10 2013 SteveUpdateGeneral Halogen illumination cables disconnectedAlex and Steve,
Old halogen chamber illuminator cabling
disconnected and potenciometer board removed
 1Y1oldilluminatersDisconnected.jpg 
  8835   Fri Jul 12 12:30:47 2013 manasaUpdateGeneral Halogen illumination cables disconnected

    

       
            
  
  8836   Fri Jul 12 12:51:13 2013 CharlesUpdateISSRMS Noise from PMC TransmissionI went out on the floor to look at the
transmitted signal from the PMC to get a
rough idea of the noise of the unstabilized
  
  8837   Fri Jul 12 12:51:16 2013 manasaUpdateLSCPRMI + ALS automation

    

       
            
  
  8838   Fri Jul 12 13:15:43 2013 KojiUpdateISSRMS Noise from PMC TransmissionIt would be better to measure the power
spectrum density of the fluctuation. 
The RMS does not tell enough information
  
  8839   Fri Jul 12 18:30:20 2013 CharlesUpdateISSRMS Noise from PMC Transmission

    

       
            
  
  8840   Fri Jul 12 21:23:42 2013 JenneUpdateASCPOP QPD calibration attemptThese are the data, one plot for when the
vertical QPD position was changed, and one
for when the horizontal (yaw) QPD position
 ChangeVertMicrometer_July2013.pngChangeSideMicrometer_July2013.png 
  8841   Fri Jul 12 23:13:32 2013 manasaUpdateGreen LockingALS sensor noise[Annalisa, Koji, Manasa]

In order to improve the ALS stability
 X_ALS_0712.pdfY_ALS_0712.pdf 
  8842   Sat Jul 13 03:27:20 2013 AnnalisaUpdateGreen LockingY arm caity scanI started doing a scan of the Y arm cavity
with IR with ALS enabled.
ALS
 PowerSpectrum0712ScanCavityAligned.pdfScanCavityMisPitch.pdfScanCavityMisYaw.pdf 
  8843   Sun Jul 14 17:47:28 2013 KojiUpdateIOOMC WFS maintenanceAnnalisa notified me that the MC autolocker
could not keep the MC locked.
I found the initial alignment was
  
  8844   Sun Jul 14 18:19:00 2013 AnnalisaUpdateGreen LockingArm cavity scanYesterday evening Nic and me were in the
lab. The Mode Cleaner was unlocked, but after
many attempt we could fix it and we did many
  
  8847   Mon Jul 15 14:12:15 2013 SteveUpdateVACRGA scan at day 144 Pumpdown 75, vacuum normal condition
at day 144
 
 pd75mRGA144d.pngpd75m144d.png 
  8849   Mon Jul 15 16:44:46 2013 AlexUpdateOMCOMC North Safety [Eric Alex]
We are planning on testing our laser
module soon, so we have added aluminum foil
 photo_2_(1).JPG 
  8851   Mon Jul 15 17:16:59 2013 JenneUpdateASCPOP QPD calibration attemptI tried to retake POP QPD calibration data
again today.  The MC was mostly fine,
but whenever the PRMI unlocked, both ITM
 ChangeSideMicrometer_July2013_calib2.pngChangeSideMicrometer_July2013_calib1.pngChangeVertMicrometer_July2013_calib1.png 
  8854   Tue Jul 16 01:17:21 2013 JenneUpdateASCPOP QPD calibration attempt[Rana, Jenne]
I took POP QPD calibration data with
a new method, on Rana's suggestion. 
  
  8855   Tue Jul 16 10:16:23 2013 KojiUpdate Beatbox XARM whitening modifiedThe
X arm whitening filters of the beatbox were
modified.
 Beatbox_mod.pdfALS_whitening.pdfBeatbox_input_dependence.pdf 
  8856   Tue Jul 16 13:48:26 2013 SteveUpdatePEMcranes cleanedKeven and Steve,
The 3 cranes tested and  wiped
off as preparation for upcoming vent.
  
  8858   Tue Jul 16 15:22:27 2013 manasaUpdateCDSFront ends back upc1sus, c1ioo, c1iscex and c1iscey were
down. Why? I was trying to lock the arm and
I found that around this time, several computers
  
  8860   Tue Jul 16 18:20:25 2013 JenneUpdateCDSProto-ASC implemented in ASS modelThe proto-ASC now includes triggering. 
I have updated the hacky temp ASC screen
to show the DoF triggering.  I have
  
  8861   Tue Jul 16 19:16:12 2013 ranaUpdateDAQNDS2 StatusI have
modified the settings on the router that
  
  8864   Wed Jul 17 22:49:37 2013 KojiUpdateGreen LockingALS Y whitening filter change[Koji Annalisa]
We did the same mod of the beatbox
for the Y arm too. See 
  
  8865   Wed Jul 17 22:51:50 2013 KojiUpdateGreen LockingALS Y performance with the new whitening filter[Manasa Koji]
Summary: 
The new whitening filters improved
 ALS_Y_130717.pdfALS_Y2_StripTool.png 
  8866   Thu Jul 18 01:10:00 2013 kiwamuUpdateGreen LockingALS Y performance with the new whitening filter 
  
  8867   Thu Jul 18 02:21:41 2013 KojiUpdateLSCPRMI+Y arm ALS success![Koji, Jenne, Manasa, Annalisa, Rana,
Nic]
 Screenshot-Untitled_Window1.pngPRMI_Yarm.pdf 
  8868   Thu Jul 18 10:47:21 2013 JamieUpdateLSCPRMI+Y arm ALS success!AWESOME!  You guys rock.   
  8869   Thu Jul 18 10:50:54 2013 LisaUpdateLSCPRMI+Y arm ALS success!

    

       
            
  
  8870   Thu Jul 18 15:34:15 2013 Alex ColeUpdateElectronicsPD Frequency Response Update [Eric, Alex]
Our RF Switch arrived today, and
we mounted it in rack 1Y1 (1st attachment). 
 photo_3_(1).JPGphoto_1_(4).JPGphoto_2_(4).JPG 
  8871   Thu Jul 18 15:55:31 2013 JenneUpdateLSCPRMI+Y arm ALS Sensing MatricesLast
night, I took sensing matrix data at various
different offsets for the Yarm. 
 SensMatMeas_17July2013_PRMI_YarmOffResonance.pngSensMatMeas_17July2013_PRMI_YarmMidResonance.pngSensMatMeas_17July2013_PRMI_YarmOnResonance.png 
  8872   Thu Jul 18 16:30:08 2013 KojiUpdateLSCPRMI+Y arm ALS Sensing MatricesHmm. I agree that something was funny.

Let's take the matrix without the
  
  8876   Thu Jul 18 21:45:36 2013 CharlesUpdateISSISS - Full Schematic Here I have included the full schematic
(so far) of the proposed ISS. There are two
sheets: the first schematic details the filter
 40mServo_v1.pdf 
  8878   Fri Jul 19 12:00:12 2013 manasaUpdateGreen LockingALS Y performance with the new whitening filter

    

       
            
  
  8879   Fri Jul 19 12:02:18 2013 manasaUpdateLSCPRMI+Y arm ALS success!Data retrieved using getdata (30 minutes
trend) saved at
  
  8880   Fri Jul 19 12:23:34 2013 manasaUpdateCDSCDS FE not happyI found CDS rt processes in red. I did 'mxstreamrestart'  Screenshot-Untitled_Window.png 
  8881   Fri Jul 19 14:04:24 2013 KojiUpdateCDSCDS FE not happydaqd was restarted.

- tried telnet fb 8088
  