40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 205 of 341  Not logged in ELOG logo
ID Date Authorup Type Category Subject Text Attachments
  12396   Wed Aug 10 19:37:08 2016 gautamUpdateElectronicsMic AmplifierIn order to help Praful do his huddle test,
I have temporarily arranged
for the outputs of the 3 channels he wants
  
  12401   Thu Aug 11 11:56:40 2016 gautamUpdateSUSETMY re-suspended


 pitchBalancingWithBias.PDF 
  12407   Sat Aug 13 18:25:22 2016 gautamUpdateCOCRC folding mirrors - Numerical reviewThis elog
is meant to summarize my numerical simulations
for looking into the effects of curvature
 PRX_consolidated.pdfSRX_consolidated.pdfGouy_PRC.pdfGouy_SRC.pdf 
  12411   Mon Aug 15 18:28:15 2016 gautamUpdateSUSAir-bake preparationI
assume that we are prepared to live with
the pitch bias situation of ETMY
 IMG_6816.JPG 
  12413   Tue Aug 16 11:51:43 2016 gautamUpdateCOCRC folding mirrors - Numerical reviewSummary of roundtable meeting yesterday
between EricG, EricQ, Koji and Gautam:

We identified two possible courses
 PRC_consolidated.pdfSRC_consolidated.pdfGouyPRC.pdfGouySRC.pdf 
  12414   Tue Aug 16 16:38:00 2016 gautamUpdateCOCRC folding mirrors - Numerical reviewHere are the results for case 2: (flat
PR3/SR3, for purpose of simulation, I've
used a concave mirror with RoC in the range
 PRC_consolidated.pdfSRC_consolidated.pdfGouyPRC.pdfGouySRC.pdf 
  12415   Tue Aug 16 21:54:27 2016 gautamUpdateSUSAir-bake - IN PROGRESSI
put in both ETMX and ETMY into the air-bake
oven at approximately 8.45pm tonight.
 IMG_3005.JPG 
  12417   Wed Aug 17 14:37:36 2016 gautamUpdateCOCRC folding mirrors - Numerical review


 PRG.pdf 
  12420   Wed Aug 17 23:00:57 2016 gautamUpdateSUSAir-bake of towersI just put in the following into the air
bake oven for a 12 hour, 70C bake:


ETMX and ETMY cages (with
 IMG_3006.JPG 
  12422   Thu Aug 18 14:14:20 2016 gautamUpdateSUSAir-bake of towers - finishedI took the two cages, wires and wire clamps
out this morning, back into the cleanroom
after their 12 hour 70C bake. 
  
  12424   Fri Aug 19 22:51:12 2016 gautamUpdateSUSETMs first-contactedI've applied first contact to both
the ETMs. They're now ready to be suspended.
I've also cut up some lengths of the
  
  12426   Sun Aug 21 16:23:05 2016 gautamUpdateSUSETMX suspended
ETMX has been successfully suspended
I've
used one of the new wire clamps, and also
the new suspension wire 
Because
 IMG_3018.JPG 
  12428   Mon Aug 22 13:06:11 2016 gautamUpdateSUSETMY suspendedToday morning, I suspended ETMY and made
the same checks dscribed below. The clamping
went smoothly, 5 in. lb. of torque seems
 IMG_3019.JPG 
  12430   Mon Aug 22 18:04:24 2016 gautamUpdateSUSETMY OSEMs inserted[Johannes, gautam]

We worked on trying to insert the
OSEMs in the optimal positions such that
  
  12434   Tue Aug 23 19:35:38 2016 gautamUpdateSUSETMY back in IFO[johannes,
gautam]
 10x 
  12443   Thu Aug 25 20:07:35 2016 gautamUpdateSUSOSEM issues - maybe resolved?[lydia, johannes,
gautam]

While
  
  12444   Thu Aug 25 21:11:43 2016 gautamUpdateSUSETMY back in IFOThere was
some confusion as to the order in which we
should go about trying to recover the Y arm.
 ETMY_BounceSpectra_25Aug2016.pdf 
  12445   Fri Aug 26 11:35:44 2016 gautamUpdateSUSETMY UL sensor problematic I've been noticing that the ETMY UL
sensor output has been erratic  over
the last few days. It seems to be jumping
 ETMY_BounceSpectra_26Aug2016.pdf41.png19.png 
  12448   Fri Aug 26 17:48:14 2016 gautamUpdateSUSbounce mode coupling reductionWe worked on reducing the bounce mode coupling
into the sensor signals today. After some
trial and error, essentially following the
 ETMY_BounceSpectra_26Aug2016_1.pdf 
  12449   Sun Aug 28 21:40:11 2016 gautamUpdateSUSETMY UL sensor problematic I wanted to observe the UL coil for any
excursions over the weekend. Looking at the
2 day trend, something is definitely wrong.
 ETMY_UL_problematic.png 
  12450   Mon Aug 29 09:37:05 2016 gautamUpdateSUSETMY UL sensor problematic It looks like the problem is indeed in
the Satellite box. Attachment #1 shows the
second trend for the last 12 hours (~930pm
 satelliteBox.png 
  12451   Mon Aug 29 14:42:06 2016 gautamUpdateSUSETMY Satellite box diagnosticsI opened up the ETMY satellite box to investigate
the glitches seen in the UL sensor output. 

Attachments #1 & 2: The
 IMG_6840.JPGIMG_6841.JPG 
  12455   Tue Aug 30 20:26:36 2016 gautamUpdateSUSITMY installed[gautam,
johannes, lydia]
 IMG_3052.JPGSRM_sensor_level_comp.pngETMY_BounceSpectra_30Aug2016.pdf 
  12457   Wed Aug 31 22:09:18 2016 gautamUpdateSUSY arm locked to Green Koji tweaked the alignment sliders till
we were able to get the Y arm locked to green
in a 00 mode, GTRY ~ 0.5 which is the prevent
  
  12458   Wed Aug 31 23:01:02 2016 gautamUpdateSUSthe chamber HEPA tents are backSome more numbers we found while working
in/around the chamber today:

  
  12466   Fri Sep 2 21:09:08 2016 gautamUpdateSUSY arm locked in air[johannes, lydia, gautam]


The Y arm has been locked
to IR in air using POY11 as an error signal 
 03.png56.png 
  12467   Fri Sep 2 21:15:53 2016 gautamUpdateSUSITMX and ETMX preemptive table levelingThe ITMX table had relaxed overnight into
a slightly misaligned state overnight - since
the ITMX table holds PR2 and hence can affect
  
  12471   Tue Sep 6 00:14:14 2016 gautamUpdateElectronicsSatellite Amplifier 




 osempdComparison.pdf 
  12474   Tue Sep 6 20:45:14 2016 gautamUpdateSUSX arm test masses back in chamber[Teng, Johannes,
Lydia, gautam]


The
 IMG_3137.JPGIMG_3143.JPGIMG_3142.JPGIMG_3148.JPG 
  12475   Tue Sep 6 20:52:42 2016 gautamUpdateSUSOSEM issues



The
 P9060254.JPG 
  12476   Wed Sep 7 17:23:26 2016 gautamUpdateSUSPRM LR fixed for now[johannes, gautam]


We took the heavy door
off in the morning with Steve's help
The
 IMG_3208.JPGIMG_3211.JPG 
  12478   Thu Sep 8 22:12:36 2016 gautamUpdateSUSX arm in place, locked to green, IR flashes visibleDetailed elog to follow but summary of
todays activities:


ITMX and ETMX are back
  
  12480   Fri Sep 9 17:50:02 2016 gautamUpdateSUSHeavy doors on BS-PRM, ETMY chambers[steve, teng, johannes, lydia, gautam]


we set about doing some
final checks on the Y arm while Johannes
  
  12526   Fri Sep 30 19:53:07 2016 gautamUpdateendtable upgradeX end IR pickoff fiber coupled[johannes, gautam]

Today we re-installed the fiber
coupler on the X-endtable to couple some
  
  12532   Wed Oct 5 16:28:10 2016 gautamUpdateendtable upgradeEX laser power monitor PD installedI installed a 10% BS to pick off some of
the light going to the IR fiber, and have
added a Thorlabs PDA55 PD to the EX table
  
  12533   Wed Oct 5 19:10:04 2016 gautamUpdateGeneralArm loss measurement review[ericq,gautam]

There are multiple methods by which
the arm loss can be measured, including,
  
  12534   Wed Oct 5 19:43:13 2016 gautamSummaryGeneralVent reviewThis elog is meant to review some of the
important changes made during the vent this
summer - please add to this if I've forgotten
  
  12542   Mon Oct 10 11:48:05 2016 gautamUpdateCDSPower-cycled c1susaux, realigned PMC, spots centered on WFS1 and WFS2[Koji, Gautam]

We did the following today morning:


I re-aligned the PMC -
  
  12545   Mon Oct 10 18:34:52 2016 gautamUpdateGeneralPZT OM MirrorsI did a quick survey of the drive electronics
for the PZT OM mirrors today. The hope is
that we can correct for the clipping observed
  
  12551   Tue Oct 11 13:30:49 2016 gautamUpdateSUSPRM LR problematic againPerhaps the problem is electrical? The
attached plot shows a downward trend for
the LR sensor output over the past 20 days
 PRM_LR_decay.png 
  12552   Wed Oct 12 13:34:28 2016 gautamUpdateSUSPRM LR problematic againLooks like what were PRM problems are now
seen in the SRM channels, while PRM itself
seems well behaved. This supports the hypothesis
 08.png 
  12560   Thu Oct 13 19:28:14 2016 gautamUpdateGeneralin-air alignmentI did the following today to prepare for
taking the doors off tomorrow.


Locked MC at low power

low
  
  12561   Fri Oct 14 10:31:53 2016 gautamUpdateGeneraldoors are off ITMY and BS/PRM chambers[steve,ericq,gautam]

We re-checked IMC locking, arm
alignments (we were able to lock and dither
  
  12563   Fri Oct 14 18:33:55 2016 gautamUpdateGeneralAS clipping investigations[steve,ericq,gautam]

In the afternoon, we took the heavy
door off the OMC chamber as well, such that
 7x 
  12566   Mon Oct 17 22:45:16 2016 gautamUpdateGeneralAS beam centered on all OMs[ericq, lydia, gautam]

IMC realignment, Arm
dither alignment
 7x 
  12568   Tue Oct 18 18:56:57 2016 gautamUpdateGeneralOM5 rotated to bypass OMC, green scatter is from window to PSL table[ericq, lydia, gautam]


We started today by checking
leveling of ITMY table, all was okay on that
 OMCchamber.pdfgreenGhosts.JPGIMG_3322.JPGIMG_3326.JPG 
  12571   Wed Oct 19 16:41:55 2016 gautamUpdateGeneralHeavy doors back on[ericq, lydia, steve, gautam]


We aligned the arms, and
centered the in-air AS beam onto the PDs
 8x 
  12576   Fri Oct 21 02:06:20 2016 gautamUpdateGeneralIFO recoveryThe pressure on the newly installed gauge
on the X arm was 6E-5 torr when I came in
today evening, so I decided to start the
  
  12578   Mon Oct 24 11:39:13 2016 gautamUpdateGeneralALS recoveredI worked on recovering ALS today. Alignments
had drifted sufficiently that I had to to
the alignment on the PSL table onto the green
 ALSOutOfLoop20161024.pdfXendPDHOLTF20161024.pdf 
  12579   Tue Oct 25 15:56:11 2016 gautamUpdateGeneralPRFPMI locked, arms loss improved[ericq,gautam]

Given that most of the post vent
recovery tasks were done, and that the ALS
 PRFPMIlock_25Oct2016.pdfITMYwoes.png 
ELOG V3.1.3-