40m QIL Cryo_Lab CTN SUS_Lab CAML OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 204 of 355  Not logged in ELOG logo
ID Date Author Type Categoryup Subject Text Attachments
  4797   Wed Jun 8 23:17:25 2011 kiwamuUpdateLSCDRMI output matrix diagonalizationApproximately
two weeks ago I diagonalized the LSC output
matrix for the DRMI locking.
 Screen_shot_2011-06-08_at_23.21.28.png 
  4805   Fri Jun 10 14:50:37 2011 KojiUpdateLSCNew LSC code installed[Koji Jamie]
The new c1lsc code has been installed.
The LSC screens have also been updated (except
  
  4808   Mon Jun 13 12:34:21 2011 Jamie, KojiUpdateLSCUpdated LSC model installedAfter a couple of hickups, I was able to
compile and install Koji's rework of the
LSC model.
  
  4818   Tue Jun 14 18:12:34 2011 Jamie, KiwamuUpdateLSCLSC seems to be fully recoveredWe are now locking the arms reliably, with
reasonable transmitted power.  We zeroed
the LSC offsets with script, since they were
  
  4821   Wed Jun 15 01:30:38 2011 JamieSummaryLSCSchnupp asymmetry measurementMeasurement of Schnupp asymmetry
This
was done by measuring the relative phase
between the sidebands reflected from the
 schnupp.pngarm_phase.pyplot.pyschnupp_ETMX.pikschnupp_ETMY.pik 
  4834   Fri Jun 17 23:20:05 2011 KojiUpdateLSCSome updates of the LSC screenSome updates of the LSC screen
- Signal amplitude monitor for the
PD signals (--> glows red for more than
 screen.png 
  4845   Mon Jun 20 18:36:49 2011 SureshUpdateLSCREFL55 PD update[Suresh, Koji]
   I used a matlab code
written by Koji to analyse the transimpedance
 REFL55_response.pdf 
  4850   Tue Jun 21 20:35:50 2011 kiwamuUpdateLSCa script to measure sensing matrixLast
night I was making a script which will measure
the sensing matrix using the realtime LOCKIN
 elog.png 
  4851   Tue Jun 21 23:29:41 2011 kiwamuUpdateLSCsensing matrix measurementI
am now measuring the sensing matrix in the
DRMI configuration.
  
  4857   Wed Jun 22 17:42:03 2011 kiwamuUpdateLSCsensing matrix measurementThe sensing
matrix was measured in the DRMI configuration
 sensemat.png 
  4863   Thu Jun 23 05:22:51 2011 kiwamuUpdateLSCPRMI locking : not stable enoughI was trying   
  4864   Thu Jun 23 09:46:16 2011 ranaUpdateLSCPRMI locking : not stable enoughAll the suspensions are bad until you fix
them. But, ... there
  
  4884   Sat Jun 25 06:09:38 2011 kiwamuUpdateLSCFriday lockingI
was able to measure the sensing matrix in
the PRMI configuration.
  
  4899   Tue Jun 28 15:20:08 2011 kiwamuUpdateLSCsensing matrix measurement in PRMI configurationHere is
the result of the measurement of the sensing
 rawmatrix.pngsensmat.png 
  4905   Wed Jun 29 00:35:36 2011 KojiUpdateLSCnew LSC overview screen 80% doneNew
LSC screen is 80% completed.
It is now accessible from the LSC
 LSC_OVERVIEW.png 
  4910   Wed Jun 29 12:20:53 2011 kiwamuUpdateLSCsensing matrix measurement in PRMI configurationOf course
I made a mistake in my calculation of the
  
  4912   Wed Jun 29 14:43:12 2011 KojiUpdateLSCLSC model updatedLSC model has been updated and running,
- Now the power and signal recycling
cavity lengths are named "PRCL"
  
  4915   Thu Jun 30 00:58:19 2011 KojiSummaryLSCLSC whitening filter test[Jenne, Koji]
We have tested the LSC whitening
filters. In summary, they show the transfer
 chans_24_31_WeirdPhase.pdfOctopus.jpgTest_Inputs_Plugged_In.jpgContec_Tester_Board.jpg 
  4949   Wed Jul 6 23:03:57 2011 kiwamuUpdateLSCmodified locking scripts[Jenne / Kiwamu]
 Last night we modified the
locking scripts, that were called from C1IFO_CONFIGURE.adl,
  
  4951   Thu Jul 7 02:23:59 2011 JenneSummaryLSCLSC Whitening Filters have been fitI have fit all of the LSC whitening filters
using vectfit4.m
All the data is in my folder ..../users/jenne/LSC_WhiteningTest_29June2011/
 AS55Q.png 
  4955   Thu Jul 7 15:34:44 2011 JenneSummaryLSCLSC Whitening Filters have been fit


   
        
            
  
  4962   Tue Jul 12 11:52:54 2011 Jamie, SureshUpdateLSCLSC model updatesThe LSC model has been updated:
Binary outputs to control whitening
filter switching
We now take the
  
  4984   Mon Jul 18 20:59:19 2011 JenneUpdateLSCBig ol' mess[Jamie, Jenne]
We decided to take on the deceptively
easy-sounding task of checking that the LSC
  
  4988   Tue Jul 19 10:18:24 2011 ranaUpdateLSCBig ol' messRemember, as per our
marker board conversation, that the resistor
noise as excitation method only works if
  
  4993   Tue Jul 19 23:39:11 2011 Jamie, JenneUpdateLSCMajor overhaul of LSC rack; binary switching of whitening filters now workingYesterday we started going through the
LSC binary whitening switching to make sure
the new switching control in the LSC model
  
  4996   Wed Jul 20 06:52:01 2011 SureshUpdateLSCABSL - PSL beat lockThe ABSL locking setup to the PSL is down. 
According
the plan, I started to use the IR beam dumped
after the doubling crystal for the IR beat
  
  5040   Wed Jul 27 01:58:23 2011 kiwamuUpdateLSClocking statusThrough some locking exercise   
  5041   Wed Jul 27 08:59:10 2011 SureshUpdateLSClocking status I had to realign PSL beam into the
MC in order to reobtain the MC lock. 
We lost lock at sometime around 8:30 AM on
 MC_RFPD_DCMon.png 
  5054   Thu Jul 28 16:10:34 2011 kiwamuUpdateLSCBoth arm locked[Nicole / Jamie / Rana / Kiwamu]
  The X arm and Y arm have been
locked.
  
  5074   Sun Jul 31 00:05:52 2011 kiwamuUpdateLSCscript for loss measurement : modifiedI
modified the script armloss
so that the channel names in the script are
  
  5076   Sun Jul 31 17:28:34 2011 kiwamuSummaryLSCTolerance of Arm length = 2 cm Required
arm length = 37.7974 +/- 0.02 [m]
 random2cm.pngarmsensMAT.pngPOP55phase2cm.png 
  5077   Sun Jul 31 22:35:35 2011 kiwamuUpdateLSCarm loss measurement : doneI
did the measurement of the arm loss on both
X and Y arm by running the armLoss
  
  5081   Mon Aug 1 11:46:56 2011 ranaSummaryLSCTolerance of Arm length = 2 cmwow. This Monte-Carlo matrix is one of
the most advanced optical modeling things
I have ever seen. We never had this for any
  
  5086   Mon Aug 1 23:26:32 2011 KojiUpdateLSCREFL33 PDOld MZ PD (InGaAs 2mm, @29.5MHz) has been
modified for REFL33.
There has been no choice for the 11MHz
 REFL33_schematic_110801_KA.pdfP8011390.JPG 
  5100   Wed Aug 3 01:30:04 2011 JenneUpdateLSCAbsolute length of Xarm and Yarm measuredSo far, this is just preliminary, because   
  5101   Wed Aug 3 02:20:33 2011 KojiUpdateLSCREFL165 PDREFL165 PD has been made from the old 166MHz
PD.
As the required inductance was ~10nF
 REFL165_schematic_110802_KA.pdfP8031393.JPGP8031391.JPG 
  5112   Wed Aug 3 22:22:47 2011 KojiUpdateLSCREFL165 PDThis REFL165 was good in terms of RF, but
I forgot to make the DC path functioning.
I will try some ideas to fix this
  
  5113   Wed Aug 3 22:31:38 2011 KojiUpdateLSCREFL33 PDREFL33 is ready for the installation
Characterization results of REFL33
is found in the PDF attachment.
 REFL33_test_110801_KA.pdf 
  5121   Fri Aug 5 04:03:16 2011 KojiUpdateLSCREFL165 PDREFL165 PD was made and tested. The characterization
results are in the PDF file.
Resonance at 166.12MHz
 P8041394.JPGP8041395.JPGREFL165_test_110804_KA.pdf 
  5210   Fri Aug 12 16:42:51 2011 YoichiConfigurationLSCLSC Feed Forward CompensatorI've been working on adding feed forward (FF)
paths to our LSC code.
So far, I've made a basic feed forward functionality
 FFCinLSC.pngFFC.png 
  5218   Sat Aug 13 01:52:07 2011 YoichiUpdateLSCFeed forward delayYoichi, Koji

While I was testing the feed forward cancellation,
 Spe1.pdfTFFitting.png 
  5273   Sat Aug 20 00:42:22 2011 KeikoUpdateLSCTolerance of PRC, SRC, MICH length = 2 mm ? 
  
  5292   Tue Aug 23 17:51:37 2011 KeikoUpdateLSCTolerance of PRC, SRC, MICH length = 2 mm ?Keiko,
Kiwamu
We noticed that we have used wrong
  
  5334   Fri Sep 2 04:41:35 2011 KeikoUpdateLSCTolerance of PRC, SRC, MICH length = 5 mm ? Keiko,
Kiwamu
 MATRIX.pngdphase.png 
  5359   Wed Sep 7 16:21:35 2011 kiwamuUpdateLSCarm loss measurement : reslutsHere are the results of the arm loss measurements,
which I have done before the vent.
I ran the existing matlab script,
 Yarmloss.pngXarmloss.png 
  5360   Wed Sep 7 17:28:41 2011 kiwamuUpdateLSCX arm loss measurement : not goodThe measurement
itself wasn't good.
 Xarmlossmeasurement.png 
  5377   Sat Sep 10 14:55:28 2011 KeikoUpdateLSC3f demodulation board check To
check the demodulation boards for REFL33
and REFL165, a long cable from ETMY (SUS-ETMY-SDCOIL-EXT
  
  5378   Sat Sep 10 16:10:42 2011 KeikoUpdateLSC3f demodulation board checkThere is a LP filter just after the RF
input of an demodulation board (its schematic
can be found as D990511-00-C on DCC). I have
 REFL33-input-filter.png 
  5380   Sat Sep 10 18:57:52 2011 KeikoUpdateLSC3f demodulation board checkThe
phase delay due to the RF input filter on
the demodulation board will not bother the
  
  5381   Sat Sep 10 19:03:57 2011 ranaUpdateLSCY Arm workI lined up the Y Arm for locking and then
centered the oplevs for ETMY and ITMY.
* The ITMY OL has still got the old
  
ELOG V3.1.3-