  6965   Thu Jul 12 02:12:42 2012 yutaUpdateSUSBS 3.3 Hz motionI tried to reduce BS 3.3 Hz motion with
local damping. 3.3 Hz probably comes from
the stack, but I want to reduce this because
 BSdam.pngBSOLSUSresonantgain.png 
  6964   Wed Jul 11 16:19:08 2012 yutaUpdateSUSoplev servo phiologyI heard that Steve did great work on oplev
in Feb 2012.
Here's summary what happened to oplev
  
  6963   Wed Jul 11 14:27:29 2012 YaakovSummarySTACISCurrent STACIS StatusThe X and Y directions in the STACIS still
both oscillate uncontrollably in closed loop,
so I'll be doing my testing in Z for now.
 geo_open_z.pnggeo_open_z2.pngambient_open_z.pngambient_closed_z_geoFeed.pngopenVclosed.GIF 
  6962   Wed Jul 11 14:22:54 2012 EricSummaryGeneralSURF UpdateHere's
what I accomplished since my last elog: 
  
  6961   Wed Jul 11 13:45:01 2012 JenneUpdatePEMmore seismic noise next week

    

       
            
  
  6960   Wed Jul 11 13:36:58 2012 yutaUpdateSUSOSEM and oplev spectra of opticsBelow is angular spectra of every suspended
core optics.
As you can see, there's a peak at
 OLPITYAW.pngSUSPITYAW.png 
  6959   Wed Jul 11 11:18:21 2012 steveUpdatePEMmore seismic noise next week 
   The fabricators
of the big flume in the CES lab have begun
 testing the sediment feed system which is
  
  6958   Wed Jul 11 11:00:45 2012 MashaSummaryGeneralWeek SummaryThis week, my work fell into two categories:
Artificial Neural Networks and lab-related
projects.
 Error.fig 
  6957   Wed Jul 11 10:17:18 2012 SashaSummarySimulationsSURF - Week 2 and 3 - SummaryThese past two weeks, I've been working
on simulating a basic 
 6x 
  6956   Wed Jul 11 09:48:24 2012 LizSummaryComputer Scripts / ProgramsUpdate/daily summary testingI have been
working on configuration of the Daily Summary
webpages and have been attempting to create
  
  6955   Wed Jul 11 03:53:41 2012 yutaUpdateLSCBS 3.3 Hz motion on MIIt is not as dramatic as PRMI, but I could
see BS 3.3 Hz motion at AS and REFL when
MI is locked at dark fringe.
 REFLDCASDCMIlocked.png 
  6954   Wed Jul 11 02:25:11 2012 yutaUpdateLSCPRMI beam spot motion might be from PRM/BS motionMy hypothesis from the measurements below,
to explain PRMI beam spot motion is;
 POPDCASDC4.pngFeedback4.pngOLPITYAWandPOPDC4.pngOLPITYAWandPOPDCunlocked.png 
  6953   Tue Jul 10 21:37:05 2012 yutaUpdateLSCPRMI glitch studyPRMI
glitch certainly comes from power recylcing
gain fluctuation.
 PRMIgilitch20120709.pngPRMIgilitch20120709_closer.png 
  6952   Tue Jul 10 17:47:55 2012 yutaUpdateSUSPRM oplevs fixedI centetered PRM oplev, lowered gain and
PRM oplev servo is not oscillating any more.
It is OK for more than a softball
 PRMoplevpitOLTF.pngPRMoplevyawOLTF.pngPRMOplevSpectra20120710.png 
  6951   Tue Jul 10 10:50:02 2012 JamieConfigurationGeneralSeismometer repositioning

    

       
            
  
  6950   Tue Jul 10 03:16:17 2012 yutaUpdateLSCPRMI got more stable a bitI modified filiters for LSC_MICH and LSC_PRCL
again to cope with power recycling gain fluctuation.
After some more alignment, power recycling
 LSCMICHOLTF.pngLSCPRCLOLTF.pngPRMI20120709_2.png 
  6949   Tue Jul 10 01:52:47 2012 KojiUpdateLSCPRMI got more stable a bitThe phase margins looks still too small.
Do You need such high gain at LF?
This is not a high finesse cavity so can
  
  6947   Mon Jul 9 23:18:09 2012 yutaUpdateLSCPRMI got more stable a bitI modified filiters for LSC_MICH and LSC_PRCL.
Although modes we can see at POP and
AS look still bad, error signals are less
 LSCMICHOLTF.pngLSCPRCLOLTF.pngALL_1025928219_PRMIlocked3.pngPRMIbeammotion20120709.png 
  6946   Mon Jul 9 16:28:13 2012 MashaConfigurationGeneralSeismometer repositioning Today I REPOSITIONED
THE SEISMOMETERS 
  
  6945   Mon Jul 9 15:05:00 2012 JenneUpdatePEMSeismometers being moved, new safety shower[Masha, Jenne]
Masha is moving the seismometers,
so they are all off right now.  Were
  
  6944   Mon Jul 9 11:27:27 2012 JenneUpdateComputersc1oaf has been down for several days - BURT restore wasn't done correctly on startupThe c1oaf model hasn't been running for
a few days (since the leap second problems
we were having last week).  I had looked
  
  6943   Mon Jul 9 10:52:48 2012 MashaUpdatePEMStripTools on WallThe RMS signals generated by the updated
filtering process are now on the wall. The
NaN issue is gone it seems, and the template
  
  6942   Mon Jul 9 05:15:46 2012 yutaUpdateGreen Lockinglocked MI while ALS using ASDCI locked MI while both arm length are stabilized
at IR resonance. This could be done using
DC READOUT,
 FPMIALStrial20120709.png 
  6941   Mon Jul 9 05:02:58 2012 yutaUpdateLockingadjusted ALS filters, current RMSI adjusted filters of ALS to give more
phase margin.
RMS
 ALSXarmLengthspectra20120708.pngALSXarmOLTF.pngALSYarmOLTF.pngALSYarmLengthspectra20120708.png 
  6940   Sun Jul 8 19:31:53 2012 yutaUpdateLockingcharacterizing LSC arm lock by ALS error signalRMS
of X/Y arm length using POX/POY lock is <160
pm and <120 pm respectively. 
 XarmLengthspectra20120708.pngLSCPOYarmIRlockOLTF.pngYarmLengthspectra20120708.pngLSCPOXarmIRlockOLTF.png 
  6939   Sun Jul 8 00:58:08 2012 KojiSummaryLockingcalibrating phase tracking mode scan data

    

       
            
  
  6938   Sun Jul 8 00:27:54 2012 yutaSummaryLockingcalibrating phase tracking mode scan dataFSR
for X/Y arm are 3.97 +/- 0.03 MHz and 3.96
+/- 0.02 MHz respectively. This
  
  6936   Sat Jul 7 17:28:11 2012 MashaUpdatePEMPEM no longer freaking out (as much).

    

       
            
  
  6935   Sat Jul 7 16:34:41 2012 MashaUpdatePEMPEM no longer freaking out (as much). Hi everybody,
Sorry for flooding the ELOG about
the PEM channels. Today I
 Masha.png 
  6934   Sat Jul 7 15:48:00 2012 MashaUpdatePEMCurrent PEM status

    

       
            
  
  6933   Fri Jul 6 22:30:14 2012 MashaUpdatePEMCurrent PEM status

    

       
            
 MashaDV.png 
  6932   Fri Jul 6 20:54:54 2012 MashaUpdatePEMCurrent PEM statusHi everybody,
Last night I (with the help of Jenne
and  Jenne's advice - not to implicate her
  
  6931   Fri Jul 6 14:10:31 2012 yutaSummaryLSCcalculation of FPMI using ALSFrom calculation, phase fluctuation of
reflected beam from length stabilized arm
is not disturbing MI lock.
  
  6930   Fri Jul 6 09:52:35 2012 steveUpdateVACpump down hick up I can not understand what really
happened here with CC1 gauge or there was
really a pressure glitch.
 d3wFireworks.pngpdhickup.png 
  6929   Fri Jul 6 09:27:40 2012 steveUpdateVAC4 days at atm I'm looking for some movement indicators
of the vent-pump down events.
 
 vent_moves.png 
  6928   Fri Jul 6 09:00:34 2012 not ZachUpdateComputersNDS2 client now working on Ubuntu machines

    

       
            
  
  6927   Fri Jul 6 08:38:04 2012 steveUpdateComputerstime outWhy do we have these timing blanks?  timingblanks.png 
  6926   Fri Jul 6 02:46:03 2012 yutaUpdateLockingY arm ALS handing off to LSCHanding off the servo from ALS to LSC for
one arm is quite easy because servo filters
are pretty much same for ALS and LSC. I demonstrated
 handofftoLSC20120706.png 
  6925   Fri Jul 6 01:39:56 2012 yutaUpdateLockingMI + Y arm ALS succeed, but not bothMI with X arm length stabilized off resonance
and Y arm length stabilized at resonance
using ALS succeed, but I couldn't bring X
 FPMIALStrial20120706.pngnewALSMEDMscreen.png 
  6924   Fri Jul 6 01:12:02 2012 JenneUpdateComputersc1sus is fine

    

       
            
  
  6923   Thu Jul 5 16:49:35 2012 JenneUpdateComputersc1sus is funnyI was trying to use a new BLRMs c-code
block that the seismic people developed,
instead of Mirko's more clunky version, but
  
  6922   Thu Jul 5 13:38:05 2012 yutaSummaryLockingcavity g-factor from mode scanCavity
g-factor for X arm is 0.3737 +/- 0.002, Y
arm is 0.3765 +/- 0.003.
  
  6921   Thu Jul 5 13:12:12 2012 ZachUpdateComputersNDS2 client now working on Ubuntu machinesFrom my conversations with JZ and Leo,
it seemed there was no package that generated
the appropriate mex files. It was clear that
  
  6920   Thu Jul 5 12:27:05 2012 JamieUpdateCDSfront-end/fb communication lost, likely again due to timing offsets

    

       
            
  
  6919   Thu Jul 5 12:06:35 2012 JamieUpdateComputersNDS2 client now working on Ubuntu machines
    

       
            
  
  6918   Thu Jul 5 11:12:53 2012 JenneUpdateCDSfront-end/fb communication lost, likely again due to timing offsets

    

       
            
  
  6917   Thu Jul 5 10:49:38 2012 JamieUpdateCDSfront-end/fb communication lost, likely again due to timing offsetsAll the front-ends are showing 0x4000 status
and have lost communication with the frame
builder.  It looks like the timing skew
  
  6916   Thu Jul 5 01:34:11 2012 yutaUpdateLockingMI with X arm ALSI tried to lock FPMI using ALS, but I could
not take care of ALS for both arms + MI.
So, I decided to try one arm + MI.
  
  6915   Thu Jul 5 01:20:58 2012 yutaSummaryCDSslow computers, 0x4000 for all DAQ statusALS looks OK. I tried to lock FPMI using
ALS, but I feel like I need 6 hands to do
it with current ALS stability. Now I have
  
  6914   Wed Jul 4 21:11:53 2012 yutaUpdateLockingFPMI in vacuum is backI aligned FPMI and greens. There's no recognizable
difference between before and after the vent.
 ALL_1025495266.pngMEDMscreenshotswithCOW_20120704.png 