  11609   Thu Sep 17 03:48:10 2015 ericqSummaryLSCsome further notesSomething odd is happening with the CM
board. Measuring from either input to OUT1
(the "slow output") shows a nice
  
  11611   Thu Sep 17 13:06:05 2015 ericqSummaryLSCLow input impedance on CM boardAs it turns out, our version of the common
mode board does not have
high input impedence. I think this is what
  
  11619   Fri Sep 18 11:59:08 2015 ericqUpdateLSCAUX X Laser Current RevertedOnce again, the transmitted X green beam
was showing enormous intensity fluctuations
(50x higher than normal). Last month, I reduced the
  
  11620   Fri Sep 18 13:33:17 2015 ericqUpdateLSCFast ALS troubles - Noise at 36kHzTo get around the problems between the
pomona LPF and low CM board input impedance,
I've placed the LPF at the CM board fast
 IRlock_noises.pdf 
  11621   Fri Sep 18 16:08:41 2015 ericqUpdateLSCFast ALS troubles - Noise at 36kHz I looked at REFL11 and REFL55 during
PRMI lock - the line is there.

 PRMIlock_REFLspectra.pdfIMCspectrum.pdf 
  11626   Mon Sep 21 11:40:30 2015 ericqUpdateGeneralMegatron maitenenceThe MC autolocker and FSSslow scripts weren't
running on Megtron. These were started by
running the following commands on megatron:
  
  11629   Mon Sep 21 23:18:55 2015 ericqSummaryComputer Scripts / ProgramsFrequency counting algorithmI definitely think lowpassing the output
is the way to go. Since this frequency readback
will be used for slow control of the beatnote
  
  11632   Tue Sep 22 03:48:18 2015 ericqUpdateLSCDRMI tweaked, briefly held with ALS armsGiven the RF component power supply grounding,
POP110, POP22 and REFL165 all changed somewhat.
They have all been rephased for the DRMI,
  
  11634   Tue Sep 22 16:42:39 2015 ericqUpdateIOOHousekeepingI've moved the OAF MC2 signal path
to go directly from c1oaf to c1mcs, so that
the LSC being ON/OFF doesn't interfere
  
  11635   Tue Sep 22 16:52:36 2015 ericqSummaryGeneralRandom NotesSome things bouncing around my head that
haven't made it to ELOG yet:


Last week, Rana and I were
  
  11637   Wed Sep 23 03:08:50 2015 ericqUpdateLSCDRMI + ALS Arms[ericq, Gautam]

We can reliably
 DRMIarms.pdf 
  11638   Wed Sep 23 10:31:49 2015 ericqUpdateLSCDRMI + ALS ArmsLooking good. How many meters of CARM is
'-1 counts'?
  
  11640   Thu Sep 24 17:01:37 2015 ericqUpdateComputer Scripts / ProgramsFreeing up some space on /cvs/cdsI noticed that Chiara's backup HD (which
has a capacity of 1.8TB, vs the main drives
2TB) was near to getting full, meaning that
  
  11641   Thu Sep 24 17:06:14 2015 ericqUpdateCalibration-RepairC1CAL LockinsJust a quick note for now: I've repopulated
C1CAL with a limited set of lockin oscillators/demodulators,
informed by the aLIGO common LSC model. Screens
  
  11648   Tue Sep 29 16:52:49 2015 ericqUpdateLSCFast ALS troubles - unknown zeroFast ALS control continues to elude me. 

I fixed my LPF to take the input
impedance of the CM board input into account;
 OLG_fastALS.pdf 
  11651   Wed Sep 30 10:00:02 2015 ericqUpdateLSCused LISOLISO confirms that I did my algebra right
in picking the component values, and shows
no extra zeros. 
  
  11658   Fri Oct 2 03:29:16 2015 ericqUpdateLSCFast ALS progress - AO path crossed over, but no high BWI've been using an SR560 to experiment
with differnent pole frequencies, to try
and cancel the mystery zero. It's after
 crossedover.pdf 
  11667   Mon Oct 5 11:25:21 2015 ericqUpdateSUSETMY OL laser deadGautam alerted me that the Y arm looked
like it was being dithered, even though the
ASS was turned off. I found that the ETMY
 ETMY-OLSUM.png 
  11669   Tue Oct 6 03:30:17 2015 ericqUpdateLSCDRFPMI Progress[ericq, Gautam]

Highlight of the night: the DRFPMI
was held at arm powers > 110 for 20 seconds.
  
  11671   Thu Oct 8 04:48:50 2015 ericqUpdateLSCDRFPMI ProgressProgress was made. CARM was stably locked
on RF only. DARM was RF only for a few moments
before I typed in a wrong number...
  
  11673   Thu Oct 8 14:14:50 2015 ericqUpdateLSCDRFPMI Progress


  
  11676   Fri Oct 9 09:22:38 2015 ericqUpdateLSCDRFPMI Progress   oct8_allRF.pdf 
  11678   Fri Oct 9 11:41:09 2015 ericqUpdateVACN2 Pressure fellAt 10:02AM, the N2 Pressure fell below
60 PSI. The watch script saw this happen,
but I did not recieve the email it is supposed
  
  11679   Fri Oct 9 13:31:21 2015 ericqUpdateLSCALS plant shapeTo get a better look at how to do fast
ALS, I took some "Plant TF"
measurements of the X arm. 
 xarm_plantTFs.pdf 
  11681   Fri Oct 9 16:23:25 2015 ericqUpdateLSCALS plant shapeAh, I understand it now! Since the additive
offset path keeps the post-cavity frequency
TF flat, the pre-cavity frequency must grow
  
  11682   Fri Oct 9 16:43:50 2015 ericqUpdateIOOWeird IMC behaviorA few minutes ago, Gautam and I were poking
around the IOO rack, looking at where he
should power his frequency divider box, and
 IMC_oddity.png 
  11685   Tue Oct 13 05:48:39 2015 ericqUpdateLSC:/[ericq, Gautam]

Despite our best efforts, the grappa
remains out of reach: the DRFPMI was not
  
  11686   Tue Oct 13 16:28:21 2015 ericqUpdateLSCFast ALS pomonaI've made a cascaded passive 2-pole
pomona box for fast ALS use, using LISO to
check that it'll give the right shape
 liso_lp.zip2LPfit.pdf 
  11687   Tue Oct 13 17:04:54 2015 ericqUpdateCDSCDS thingsAfter some discussion at last week's
40m meeting, I increased the frequency of
daqd trying to write out minute trends from
  
  11691   Thu Oct 15 03:08:57 2015 ericqUpdateLSCDRFPMI Locked for 20 sec[ericq, Gautam]

For real this time.

 DRFPMI_locked.pdf 
  11692   Thu Oct 15 04:14:14 2015 ericqUpdateLSCDRFPMI Locked for 20 secFast ALS was still a problem tonight. I
don't think high frequency ALS noise
saturating the PC drive is the issue; I put
  
  11694   Thu Oct 15 14:39:58 2015 ericqUpdateComputer Scripts / Programsnodus web apache simlinks too soft


  
  11698   Mon Oct 19 15:23:22 2015 ericqUpdateLSCLonger DRFPMI lockHere is a longer lock, about 100 seconds
RF only, from later that same night. The
in-loop CARM and DARM error signals have
 second_DRFPMI_15Oct2015.png 
  11699   Mon Oct 19 16:16:01 2015 ericqUpdateCDSC1ALS crashesGautam was working on his digital frequency
counter stuff when the c1als model crashed.
I had trouble bringing it back until I realized
  
  11700   Mon Oct 19 16:20:52 2015 ericqUpdateLSCGreen beatnote couplers installedLast Friday, I installed some RF couplers
on the green BBPDs' outputs, and sent
them over to Gautam's frequency divider
  
  11701   Tue Oct 20 11:24:29 2015 ericqHowToLSCHow to DRFPMIHerein,
I will describe
the current settings and procedures used
  
  11702   Tue Oct 20 15:51:44 2015 ericqUpdateSUSMC2 F2P tunedUsing a modified version of Hang's
deMod_deCoup scripts, I tuned the MC2 coil
output matrix to minimize the appearance
  
  11703   Tue Oct 20 16:27:04 2015 ericqUpdateVACvacuum VME machines rebooted[ericq, Gautam, Steve]

Following roughly the same procedure
as ELOG
  
  11716   Tue Oct 27 03:46:26 2015 ericqUpdateSUSMC2 F2P mis-tunedD'oh. Good point.

Reverted for now; I'm thinking
about doing laser pointer->MC2 QPD...
  
  11718   Tue Oct 27 03:56:52 2015 ericqUpdateLSCDRFPMI workA handful of DRFPMI locks tonight, longest
one was ~7 minutes. 

EPICS/network latency has been
  
  11721   Wed Oct 28 17:06:30 2015 ericqUpdateASCNew PRC Angular FF filters installedI've installed new filters for the
T240 -> PRM static online angular feedforward
that were trained after some of the recent
  
  11722   Thu Oct 29 03:25:49 2015 ericqUpdateLSCDRFPMI work[ericq, Gautam]

The length of DRFPMI lock did not
increase much tonight, but we got a ~80 second sensing
 DRFPMI.pdfDRMIarms.pdf 
  11726   Tue Nov 3 03:12:46 2015 ericqUpdateLSCDRFPMI workTonight was kind of a wash. 

We spent some time retaking
single arm scans with Gautam's frequency
  
  11729   Wed Nov 4 14:44:00 2015 ericqUpdateSUSETMX oplev servo disabledI've turned the ETMX oplev servos off
for the time being. (At the input side, so
that no scripts will accidently turn it on).
  
  11731   Wed Nov 4 16:12:07 2015 ericqUpdateCDSOPTIMUSThere is a new machine on the martian network: 32
cores and 128GB of RAM. Probably this is
more useful for intensive number crunching
 optimus.png 
  11733   Wed Nov 4 22:42:02 2015 ericqUpdateSUSETMX oplev servo disabledDuring this time period, it looks like
there was maybe one excursion. Here are the
individual OSEM signals, which I think to
 ETMXexcursion.png 
  11742   Mon Nov 9 15:59:06 2015 ericqUpdateLSCFSR and linewidth measurements with phase tracker


  
  11744   Mon Nov 9 23:22:18 2015 ericqUpdateSUSETMX oplev servo disabledDuring a ETMX kick that just occured, with
only local damping on, the slow VMon channels
didn't show any noticable change. 
 Vmon_duringkick.png 
  11758   Thu Nov 12 10:47:17 2015 ericqUpdateSUSETMX oplev servo disabledBy looking at the oplev and Vmons before
and after a step of 90 counts in SUS-ETMX_PIT_OFFSET,
I observe:
  
  11759   Thu Nov 12 16:00:55 2015 ericqUpdateIOOPSL Laser turned back onWe found the PSL laser switched off. Looking
at the wall StripTool, it looks like this
happened about 4 hours ago. Gautam was working
  
ELOG V3.1.3-