  6950   Tue Jul 10 03:16:17 2012 yutaUpdateLSCPRMI got more stable a bitI modified filiters for LSC_MICH and LSC_PRCL
again to cope with power recycling gain fluctuation.
After some more alignment, power recycling
 LSCMICHOLTF.pngLSCPRCLOLTF.pngPRMI20120709_2.png 
  6953   Tue Jul 10 21:37:05 2012 yutaUpdateLSCPRMI glitch studyPRMI
glitch certainly comes from power recylcing
gain fluctuation.
 PRMIgilitch20120709.pngPRMIgilitch20120709_closer.png 
  6954   Wed Jul 11 02:25:11 2012 yutaUpdateLSCPRMI beam spot motion might be from PRM/BS motionMy hypothesis from the measurements below,
to explain PRMI beam spot motion is;
 POPDCASDC4.pngFeedback4.pngOLPITYAWandPOPDC4.pngOLPITYAWandPOPDCunlocked.png 
  6955   Wed Jul 11 03:53:41 2012 yutaUpdateLSCBS 3.3 Hz motion on MIIt is not as dramatic as PRMI, but I could
see BS 3.3 Hz motion at AS and REFL when
MI is locked at dark fringe.
 REFLDCASDCMIlocked.png 
  6972   Thu Jul 12 23:15:34 2012 yutaUpdateLSCPRMI LSC is making PRM motion worseIt looks like PRMI LSC is making PRM motion (and
BS motion) at ~3Hz worse.
 PRMBSPRMIonoff.pngITMXITMYPRMIonoff.pngOplevPRMIonoff.png 
  6976   Sun Jul 15 16:25:15 2012 ranaUpdateLSCPRMI LSC is making PRM motion worseAs   
  7029   Wed Jul 25 15:33:55 2012 janoschUpdateLSCringdown measurementWe did our first ringdown measurement on
the Y arm. First we tried to keep the arm
locked in green during the ringdown, but
 Rindown1.png 
  7030   Wed Jul 25 16:31:01 2012 JenneUpdateLSCYarm green locking to arm - PDH box saturating

    

       
            
  
  7033   Wed Jul 25 22:16:36 2012 KojiUpdateLSCringdown measurementIs this the step response of the single
pole low pass???
It should have an exponential decay,
  
  7038   Thu Jul 26 13:10:51 2012 janoschUpdateLSCmodelled ringdownWe fitted shutter and ringdown functions
to the ringdown data. It is not perfectly
clear how the power change due to the shutter
 Ringdown.png 
  7039   Thu Jul 26 15:43:03 2012 ranaUpdateLSCmodelled ringdownYou cannot use the digital system for this.
You hook up a scope to the transmitted light
as well as the incoming light (after the
  
  7073   Wed Aug 1 18:20:58 2012 JamieUpdateLSCYarm recovered[Jenne, Jamie]
We recovered lock and alignment of
the Y arm.  TRY_OUT is now at ~0.9,
  
  7078   Thu Aug 2 11:09:52 2012 EricSummaryLSCFree-Swinging Michelson MeasurementsTo take the free swinging Michelson measurements
for the interferometer calibration Jamie
aligned the beam splitter with ITMX and ITMY.
 free_swing_MICH.png 
  7170   Tue Aug 14 04:37:06 2012 YoichiSummaryLSCXARM Open Loop GainYoichi, Rana
Here is the open loop gain of the
XARM loop.
 xarm-opltf.png 
  7171   Tue Aug 14 04:53:45 2012 YoichiSummaryLSCX-Arm noise spectrumYoichi, Rana
Here is the noise spectrum of the
X-arm error signal along with the TRX DC
 xarm-spectrum.png 
  7184   Tue Aug 14 22:16:46 2012 JenneUpdateLSCLSC whitening triggersI'm ~30% of the way through implementing
LSC whitening filter triggers.  I think
that everything I have done should be compile-able,
  
  7187   Wed Aug 15 04:03:55 2012 ranaSummaryLSCY-Arm Locking0) Did a bunch of alignment to get beams
roughly centered on ETMY and ITMY and maximize
power. Adjusted the aperture and focus on
 yArmNoise_120815.pngyarm.pdf 
  7188   Wed Aug 15 09:09:45 2012 jamieUpdateLSCLSC whitening triggers

    

       
            
  
  7191   Wed Aug 15 11:44:35 2012 jamieSummaryLSCntp installed on all workstations

    

       
            
  
  7211   Fri Aug 17 00:16:30 2012 EricSummaryLSCYARM CalibrationI modified my Simulink model of the YARM
to match the new filter modules Rana installed
on YARM. I also scaled the open loop transfer
 olg_model_meas.pnglength_response_model.pngyarm_uncal_power_spec.pdfyarm_cal_power_spec.pdf 
  7213   Fri Aug 17 04:54:01 2012 Yoichi, KojiSummaryLSCPRMI Locking To taste the strangeness of the current
40m PRC, I locked the PRMI with the guide
of Koji.
 AS_1029238601.jpgPOP_1029238616.jpgREFL_1029238629.jpgPRMI-OPLG.png 
  7224   Sat Aug 18 03:55:12 2012 YoichiSummaryLSCX-arm locking againTonight, I worked on the X-arm locking
again. I did not have any significant progress,
but observed several issues and will give
 MC_Trans.png 
  7274   Fri Aug 24 21:00:40 2012 KojiUpdateLSCX end green investigationI checked and fixed the X end green situation.
Now
the X green beam is locked with TEM00.
  
  7311   Wed Aug 29 19:28:41 2012 Elli KingUpdateLSCSetup for a cavity scan or the input mode cleaner Riju, Elli
Today we prepared
our experimental setup to take a cavity scan
 40m_cavity_scan_diagram.jpg 
  7360   Fri Sep 7 12:28:09 2012 KojiUpdateLSC11&55MHz modulations turned off11MHz modulation source was turned off
(disabled) at Marconi at 12:00.
  
  7445   Thu Sep 27 13:05:55 2012 Eric GustafsonUpdateLSC40 meter photodiode frequency response measurement system installationJenne, Mike and   
  7447   Thu Sep 27 16:26:11 2012 SteveUpdateLSCRF fibre protection in cable trays

    

       
            
  
  7448   Thu Sep 27 17:00:41 2012 Eric GustafsonUpdateLSC40 meter photodiode frequency response measurement system installationMike and I installed all of the telescopes
and launching hardware for REFL11, REFL33,
REFL55, AS55, MCRef, POX11 and POP55. On
  
  7513   Tue Oct 9 23:12:56 2012 JenneUpdateLSC11MHz reconnected to EOMRiju hasn't been in the lab in a long time
to do any measurements, so I put the signals
back to how they should be.  
  
  7515   Wed Oct 10 02:15:14 2012 ranaUpdateLSC11 MHz reconnected to EOM Absolutely hokey. What are
our requirements for this RFPD? What
are the power levels and SNR that we want
  
  7554   Tue Oct 16 00:33:29 2012 JenneUpdateLSCPOP lens placed on POX table, 2 PRMI movies[Evan, Jenne]
We aligned the PRMI.  We definitely
can lock MICH, but we're not really sure
  
  7555   Tue Oct 16 02:34:38 2012 KojiUpdateLSCPOP lens placed on POX table, 2 PRMI moviesHow
can you lock the PRMI without the REFL beams?
  
  7556   Tue Oct 16 11:38:17 2012 JenneUpdateLSCMore PRMI notes from last night

    

       
            
  
  7738   Wed Nov 21 21:06:13 2012 AyakaUpdateLSCcalibration of armsMotivation
In order to estimate whether we can
see acoustic coupling in arms or not, we
 7x 
  7739   Sat Nov 24 13:58:07 2012 ranaUpdateLSCcalibration of armsFor the loop diagnosis, its best
to use the method of "IN1/IN2",
rather than manipulate the close loop gain.
  
  7743   Mon Nov 26 10:42:06 2012 AyakaUpdateLSCcalibration of armsI uploaded a zip file that contains data
files used for the calibration.
OLTF_x/y.txt: the open loop transfer
 armcalib.zip 
  7800   Sat Dec 8 04:12:38 2012 DenUpdateLSCprcl Today I wanted to check that AS and
REFL beams are real and contain proper information
about interferometer. For this I locked YARM
 IMG_0118.JPG 
  7801   Sun Dec 9 01:21:51 2012 DenUpdateLSCbeam inside DRMI is clipping on PR3 Tip-Tilt

    

       
            
 6x 
  7802   Sun Dec 9 17:51:53 2012 ranaUpdateLSCbeam inside DRMI is clipping on PR3 Tip-Tilt 
 Some explanation of how you
define power buildup please. Also some plots
  
  7803   Mon Dec 10 03:02:03 2012 DenUpdateLSCbeam inside DRMI is clipping on PR3 Tip-Tilt

    

       
            
 PRCL_LOCK.png 
  7804   Mon Dec 10 10:13:41 2012 DenUpdateLSCbeam inside DRMI is clipping on PR3 Tip-Tilt 
That's OK, but its best to use standard
notation. The power recycling gain is defined
  
  7806   Mon Dec 10 22:34:34 2012 DenUpdateLSCbeam inside DRMI is clipping on PR3 Tip-Tilt

    

       
            
 PR2.bmpPRM_LOCK.bmpITMY.pngITMX.png 
  7808   Tue Dec 11 09:31:47 2012 AyakaUpdateLSCOplev update for improving sensitivity Motivation
We observed that oplev servos affect
 7x 
  7812   Tue Dec 11 21:53:37 2012 AyakaUpdateLSCOplev update for improving sensitivity[Rana, Ayaka]
The BS oplev pitch feedback came
back.
 OL_BSpit.pdfBSoplevservo.png 
  7814   Wed Dec 12 11:49:05 2012 AyakaUpdateLSCAcoustic noise in POX and AS error signal[Koji, Ayaka]
Last night, I injected acoustic noise
at POX table and AS table with oplev controls
 POX_noise4.pdfAScontXARM_acoustic.pdf 
  7820   Thu Dec 13 03:20:48 2012 DenUpdateLSCbeam inside DRMI is clipping on PR3 Tip-Tilt

    

       
            
 PR2_ITMX.pngPR2_ITMY.pngPR3_LOCK.png 
  7829   Fri Dec 14 03:32:51 2012 AyakaUpdateLSCHigh frequency noise in AS signalI calibrated the AS error signal into the
displacement of the YARM cavity in the same
way as I did before (elog).
 XARM_OL.pdfAS_ITMXexc.pdfASspe_noise.pdfASgain.pngASspe.tar.gz 
  7832   Fri Dec 14 09:31:59 2012 ranaUpdateLSCHigh frequency noise in AS signalThis is NOT calibrated. Its sort of calibrated
in the 500-1000 Hz area, but does not correctly
use the loop TF or the cavity pole.
  
  7833   Fri Dec 14 10:09:30 2012 AyakaUpdateLSCHigh frequency noise in AS signal

    

       
            
  
  7835   Fri Dec 14 16:35:38 2012 AyakaUpdateLSCHigh frequency sensitivity improvedSince I found that the the AS sensitivity
seems to be limited by circuit noise, I inserted
a RF amplifier just after the AS RF output.
 ASspe_noise_amp.pdfASspe_acoustic_amp.pdfASnoise.tar.gz 