40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 1 of 348  Not logged in ELOG logo
IDup Date Author Type Category Subject Text Attachments
  1   Wed Oct 17 18:46:33 2007 ranaConfigurationGeneraleLog ChangeThis is the first entry in the [U]new[/U]
40m eLog.
  
  2   Thu Oct 18 14:52:35 2007 ranaRoutineASCtest[B]test[/B]
[LINE]X-(:P;(:))
  
  3   Thu Oct 18 15:03:14 2007 ajwRoutineGeneralthis is only a test[IMG]elog:3/1[/IMG]
[IMG]elog:3/2[/IMG]
 DCreadoutNoise.pngdemo40m.png 
  5   Fri Oct 19 16:11:38 2007 pkpOtherOMCOMC PZT responseSam and I locked the laser to the OMC cavity
and looked at the error signal as a function
of the voltage applied to the OMC PZT.
 fullspec.jpg4.5to10.jpg4.5to10.pdffullres.pdf 
  6   Sat Oct 20 11:54:13 2007 waldmanOtherOMCOMC and OMC-SUS work[Rich, Chub, Pinkesh,  Chris,  Sam]

Friday the 18th was a busy day in OMC land.
  
  7   Mon Oct 22 12:02:59 2007 ajwRoutineGeneralSTACIS as microseismic shakerIn case we ever want to use our Stacis systems
as shakers, check this:
[URL=http://www.techmfg.com/appnotes/Stacis_microseismic_shaker_appnote.htm]link[/URL]
  
  8   Mon Oct 22 19:27:14 2007 pkpOtherOMCPZT calibration/ transfer function.We measured the PZT transfer function by comparing
the PZT response of the circuit with the
cavity in the loop, with that of the circuit
 calib.pdfcalibpzt2.pdfall2.pdfnoPZT2.pdf 
  9   Tue Oct 23 09:01:00 2007 ranaOtherOMCPZT calibration/ transfer function.Are you sure that the error signal sweep is
not saturated on the top ends? This is usually
the downfall
  
  10   Tue Oct 23 11:08:20 2007 steveOtherGeneralbrush firesThere are big brush fires around LA
40 days plot show no effect in the 40m lab
 brushfires.jpg 
  11   Wed Oct 24 01:43:32 2007 Andrey RodionovOtherGeneralPDF-file -> Will report about first results for XARM during Wednesday meeting
Here is  the pdf-file with some graphs showing
first results for XARM optimization.
 Andrey_October_24.pdf 
  12   Wed Oct 24 08:58:09 2007 steveOtherPSLlaser headtemp is upC1:PSL-126MOPA_HTEMP is 19.3C

Half of the chiller's air intake was covered
 htempup.jpg 
  13   Thu Oct 25 00:01:21 2007 ranaSoftware InstallationCDSGEO DV => LIGO DV[URL=http://www.aei.mpg.de/~hewitson/]Martin
Hewitson[/URL] of [B]GEO600[/B] fame has
modified the cool GEO DV
 Picture_1.png 
  14   Thu Oct 25 17:52:45 2007 waldmanOtherOMCOMCs with QPDs[Rich, Chub, Pinkesh, Sam]

Yesterday we got the QPD, OTAS, and PZT cabling
  
  15   Thu Oct 25 22:02:58 2007 robRoutinePSLHEPAs maxedIn light of the SoCal fires, I turned the
PSL HEPAs up to 100%.
  
  16   Thu Oct 25 23:35:36 2007 waldmanOtherOMCHang the OMC![Pinkesh, Sam]

We tried,  convicted and hung the OMC today.
 IMG_1483.jpgIMG_1481.jpg 
  17   Fri Oct 26 09:10:17 2007 steveRoutinePEMPEM &PSL trendThe fires are out, lab particle counts are
up.
Psl HEPAs are at 100% and mobel HEPAs are
 counts&psl.jpg5dcounts.jpg 
  18   Fri Oct 26 16:19:29 2007 Tobin FrickeRoutineIOOMC resonancesWe would like to measure the absorption of
the mode cleaner optics.  The plan is to
repeat <a href="http://ilog.ligo-wa.caltech.edu:7285/mLIGO/Cleaning_the_Mode_Cleaner">Valera's
  
  19   Fri Oct 26 17:34:43 2007 waldmanOtherOMCOMC + earthquake stops
[Chub, chris, Pinkesh, Sam]
  
  20   Fri Oct 26 21:48:40 2007 waldmanConfigurationOMCFiber to 056I set up a 700 mW NPRO in Rana's lab and launched
it onto a 50m fiber.  I got a few mW onto
the fiber,  enough to see with a card before
  
  21   Sat Oct 27 19:00:44 2007 waldmanConfigurationOMCHanging, locked OMC with REFL extracted.I got the OMC locked to the fiber output today.
 It was much more difficult than I expected
and I spent about 30 minutes or so flailing
  
  22   Sun Oct 28 03:03:42 2007 ranaConfigurationIOOThree Way Excitement[SIZE=2][B]We've been trying to measure the
MC mirror internal mode frequencies so that
we can measure
  
  23   Mon Oct 29 09:16:31 2007 steveRoutineVACthe rga is backWe had no filament current since last power
glitch of Oct. 8, 2007
First I thought that the filament was lost,
 rgaisback.jpg 
  24   Mon Oct 29 09:46:50 2007 steveRoutineVACvac & pem trendPumpdown 64 pumped by maglev for 125 days
pd64-m-d125
 pd64md125.jpg 
  25   Mon Oct 29 11:07:22 2007 waldmanSoftware InstallationOMCSoftware install on OMS[Alex, Sam]

We spent a little time this morning working
  
  26   Mon Oct 29 12:20:15 2007 waldmanConfigurationOMCChanged OMS filtersI changed the OMS configuration so that some
of the OMC-SUS LED channels go to a breakout
box so that we can input the PDH error signal.
  
  27   Mon Oct 29 23:10:05 2007 waldmanConfigurationOMCLost in DAQspace[Pinkesh, Sam]

In setting up a Digital based control of
 SS.pdfSS.gif 
  28   Mon Oct 29 23:25:42 2007 tobinSoftware InstallationCDSframes mountedI mounted the frames directory on mafalda
and linux3.  It's intentionally not listed
in the /etc/fstab so that an fb crash won't
  
  29   Tue Oct 30 00:47:29 2007 ranaOtherIOOMC RingdownsI did a bunch of [B]MC ringdown measurements[/B]
using the PD that Rob set up. The idea is
to put a fast PD (PDA255)
 tek00000.pngtek00001.pngtek00004.pngMC2ringdown.tar.gz 
  30   Tue Oct 30 13:58:07 2007 ajwConfigurationIOOMC RingdownsHere's a quick fit-by-eye to the latter part
of the data from tek00000.xls.
 CavityRingdown.pngCavityRingdown.m 
  31   Tue Oct 30 16:55:40 2007 tobinRoutine Drag-wiping perfectedSteve, Tobin

Steve procured an assortment of syringes
  
  32   Tue Oct 30 19:32:13 2007 tobinProblem FixedComputersconlogger restartedI noticed that the conlogger wasn't running.
 It looks like it hasn't been running since
October 11th.  I modified the restart_conlogger
  
  33   Tue Oct 30 20:15:24 2007 tobinOtherEnvironmentearthquakeRana, Tobin

Largish (M5.6) earthquake in San Francisco
  
  34   Wed Oct 31 08:33:54 2007 ranaProblem FixedSUSVent measurementsThere was a power outage during the day yesterday;
whoever was around should post something
here about the
  
  35   Wed Oct 31 08:34:35 2007 ranaOtherIOOloss measurementsIn the end, we were unable to get a good scatter
measurement just because we ran out of steam.
The idea was to get a frame
  
  36   Wed Oct 31 08:38:35 2007 ranaProblem FixedIOOMC autolockerThe MC was having some trouble staying locked
yesterday. I tracked this down to some steps
in the last
  
  37   Wed Oct 31 09:45:28 2007 waldmanOtherOMCResolution to DAQland saga[Jay, Sam]

We did a rough accounting for the linear
  
  38   Wed Oct 31 10:31:23 2007 Andrey RodionovRoutineVACVenting is in progress
We (Steve, David, Andrey) started venting
the vacuum system at 9.50AM Wednesday morning.
  
  39   Wed Oct 31 15:02:59 2007 tobinRoutineIOOMode Cleaner Mode TrackingI processed the heterodyned mode cleaner data
yesterday, tracking the three 28 kHz modes
corresponding to MC1, MC2, and MC3.  Unfortuntately
 mode-track.pdftrends.pdfmcmodetrack.zip 
  40   Wed Oct 31 15:22:59 2007 robConfigurationIOOMode Cleaner transfer functionI measured the transfer function of the input
mode cleaner using a PDA255 and the ISS.
 First I put the PD in front of the ISS out-of-loop
 MCtf.pdf 
  41   Wed Oct 31 19:26:08 2007 Andrey RodionovRoutineGeneralPhotographs of "Mode-Cleaner Entrance"
Here are the pictures of "inside the chamber".
 9x 
  42   Wed Oct 31 23:55:17 2007 waldmanOtherOMCQPD testsThe 4  QPDs for the OMC have been installed
in the 056 at the test setup.  All 4 QPDs
work and have medm screens located under
 QPD_SignalSpectrum.pdfQPD_SignalSpectrum.gif 
  43   Thu Nov 1 01:28:04 2007 waldmanOtherOMCFirst digital lock of OMC[Pinkesh, Sam]

We locked a fiber based NPRO to the suspended
 071101_PZT_firstLoopSweep.pdf071101_PZT_firstLoopSweep.gif071101_OMC_FirstLock_spectra.pdf071101_OMC_FirstLock_spectra.gif 
  44   Thu Nov 1 09:17:27 2007 steveRoutineVACvent 64Yesterday before vent I could not lock  MC,
therfore I could not measure the 
transmitted power at MC2 
 vent64.jpg 
  45   Thu Nov 1 11:45:30 2007 tobinConfigurationIOOMode cleaner drag-wipingAndrey, Bob, David, John Miller, Rana, Rob,
Steve, Tobin
  
  46   Thu Nov 1 16:34:47 2007 Andrey RodionovSummaryComputersLimitation on attachment size of E-LOG
I discovered yesterday when I was attaching
photos that it is NOT possible to attach
  
  47   Thu Nov 1 16:42:48 2007 Andrey RodionovSummaryEnvironmentEnd of Daylight Saving Time this weekendUseful information for everyone, as a friendly
reminder:
  
  48   Thu Nov 1 16:51:33 2007 d40AoGGeneralD40[SIZE=3][FONT=Comic Sans MS]If you vant see
D40 againn, you leave one plate goulash by
N2 tank in morning.
 PB010001.JPG 
  50   Thu Nov 1 19:53:02 2007 Andrey RodionovBureaucracyPhotosTobin's picture   DSC_0053.JPG 
  51   Thu Nov 1 19:53:34 2007 Andrey RodionovBureaucracyPhotosRobert's photo   DSC_0068.JPG 
  52   Thu Nov 1 19:54:22 2007 Andrey RodionovBureaucracyPhotosRana's photo   DSC_0120.JPG 
ELOG V3.1.3-