  6406   Tue Mar 13 16:56:19 2012 kiwamuUpdateLSCevolution of the sensing matrix in PRMI as a function of timeNext steps:

    Compare the obtained sensing
matrix with an Optickle model. Particularly
  
  6407   Tue Mar 13 19:14:40 2012 kiwamuUpdateLSCNoise estimatino in the REFL33Q as a MICH sensor
A feasibility study of the REFL33Q as a MICH
sensor was coarsely performed from the point
 NB_REFL33.png 
  6411   Wed Mar 14 04:19:51 2012 kiwamuUpdateLSCREFL33Q for MICH control : not good I tried the REFL33Q for controlling
MICH in the PRMI configuration (#6407)
 Untitled.png 
  6414   Wed Mar 14 13:16:50 2012 kiwamuUpdateLSCA correction on Noise estimatino in the REFL33QA
correction on the previous elog about the
REFL33Q noise:
  
  6417   Wed Mar 14 16:33:20 2012 keikoUpdateLSCRAM simulation / RAM pollution plotIn the last post, I showed that SRCL element
in the MICH sensor (AS55I-mich) is chaned
1% due to RAM.
 Mar14pollution.pngRAMexampleplot.png 
  6419   Wed Mar 14 21:01:36 2012 keikoUpdateLSCevolution of the sensing matrix in PRMI as a function of timeThis is the simulated signals
to compare with the original post #6403
  
  6420   Wed Mar 14 23:02:09 2012 KojiUpdateLSCLocking activityKiwamu and Koji
The target is to realize DRMI or
PRMI + one arm with ALS.
  
  6464   Thu Mar 29 11:29:27 2012 keikoUpdateLSCPOP22/POP110 amplifiresYesterday I and Kiwamu connected two amplifiers
(mini-circuit, ZFL-1000LNB+) for POP22/110.
Dataviewer can see some signals. I'll test
  
  6466   Thu Mar 29 18:42:11 2012 keikoUpdateLSCPOP22/POP110 amplifiresAdding two amplifiers on POP22/110,
I checked the signals going to the dmod board
of 22 and 110.
 P3290004.JPGP3290005.JPG 
  6471   Fri Mar 30 10:20:51 2012 kiwamuUpdateLSClocking last nightI was trying to make the DRMI lock more
robust.
Increasing the gains of the oplev
  
  6474   Sat Mar 31 08:01:07 2012 kiwamuUpdateLSCDRMI measurementI have measured the sensing matrix of the
DRMI although the lock still doesn't stay
for a long time.
  
  6475   Mon Apr 2 18:24:34 2012 keikoUpdateLSCRAM simulation for Full ifo I extended my RAM script from DRMI
(3DoF) to the full IFO (5DoF).
Again, it calculates the operation
  
  6478   Tue Apr 3 01:52:15 2012 ZachUpdateLSCRAM simulation for Full ifo

    

       
            
  
  6480   Tue Apr 3 14:11:33 2012 keikoUpdateLSCRAM simulation for Full ifo

    

       
            
  
  6481   Tue Apr 3 14:17:18 2012 keikoUpdateLSCRAM simulation for Full ifoI add a flow-chart drawing what the scripts
do and how the scripts calculate the LSC
matrix.
 flowchart.png 
  6482   Tue Apr 3 15:50:58 2012 keikoUpdateLSCRAM simulation for Full ifoOops,
Yesterday's results for DARM was wrong!
  
  6483   Tue Apr 3 22:50:37 2012 keikoUpdateLSCRAM simulation for Full ifoKoji and
Jamie suggested me to include the coupling
between DoFs when I calculate the last matrix.
  
  6486   Wed Apr 4 23:57:35 2012 keikoUpdateLSCRAM simulation for Full ifo I'm still wondering whether iteration
version or simple version is closer approximation
to the real situation. Sorry for few explanations
  
  6488   Thu Apr 5 06:27:51 2012 kiwamuUpdateLSCAS110 sideband monitor installed[Jenne / Kiwamu]

 We
  
  6489   Thu Apr 5 07:19:16 2012 kiwamuUpdateLSCDRMI locking I
tried locking the DRMI to the signal-extraction
condition with the new trigger by AS110.
 DRMI_2012Apr4_edit.png 
  6504   Sat Apr 7 00:31:12 2012 keikoUpdateLSCRAM simulation for Full ifoI didn't
understand how CARM can be decreased 2 orderes
of magnitude and PRCL can be INCREASED by
 plot4a.pngplot4b.png 
  6506   Sat Apr 7 01:56:05 2012 kiwamuUpdateLSCOSA signal in DRMI conditionIt wasn't a dream or illusion -- I was
locking the DRMI to the right condition last
Wednesday (#6489).
 OSA.png 
  6508   Sat Apr 7 06:58:34 2012 kiwamuUpdateLSCDRMI lock : lost good alignmentSomehow I lost the good alignment, where
the lock can be frequently acquired and hence
I didn't go further ahead.
  
  6509   Mon Apr 9 15:02:30 2012 JenneUpdateLSCLocked MICHI was going to try some locking, but things
are a little too noisy. 
Just so Kiwamu knows what I did today,
  
  6510   Mon Apr 9 15:09:34 2012 JenneUpdateLSCLocked MICH

    
        
  
  6512   Mon Apr 9 18:18:14 2012 kiwamuUpdateLSCDRMI time seriesHere is a time series when the DRMI is
being locked.
You can see that the AS110 goes up
 time_series1.png 
  6535   Sat Apr 14 00:19:35 2012 SureshOmnistructureLSCOptical Fibers for insitu RFPD characterisation    I have worked out the fibers
we need to get for the following distribution
scheme:
  
  6598   Thu May 3 17:15:38 2012 KojiUpdateLSCc1iscaux2 rebooted/burtrestored[Jenne/Den/Koji]
We saw some white boxes on the LSC
screens.
  
  6716   Wed May 30 18:08:40 2012 JamieUpdateLSCc1lsc: add error point pick-offs, moved ctrl pick-offs after feedforwardI made some modifications to the c1lsc
model in order to extract both the error
and control signals.
 LSCchain.png 
  6717   Wed May 30 18:16:44 2012 JamieUpdateLSCskeleton of new c1cal calibration model created[Jamie, Xavi Siemens, Chris Pankow]
We built the skeleton of a new calibration
model for the LSC degrees of freedom. 
  
  6735   Thu May 31 23:53:00 2012 JenneUpdateLSCLSC trigger updateI modified the lsc model (after Jamie finished)
to use a new triggering scheme.  It
HAS NOT yet been compiled and tested, since
  
  6749   Mon Jun 4 17:14:31 2012 JenneUpdateLSCLSC recompiled several times todayAs of now, the regular LSC DoF triggers
work, just as they used to.  There is
a problem with the filter module triggers
  
  6831   Mon Jun 18 23:38:39 2012 JenneUpdateLSCAdded LSC channels to framesSince the .ini files get overwritten every
time a model is compiled now, we need to
put all channels we want saved to frames
  
  6834   Tue Jun 19 23:36:19 2012 yutaUpdateLSCcalibrated POY error signal[Jenne, Yuta]

We calibrated POY error signal(C1:LSC-POY11_I_ERR).
 LSCyarmTF_usingITMY.pngLSCyarm_HAover1plusG.pngPOYerrorcalibration.png 
  6835   Wed Jun 20 00:01:04 2012 JenneUpdateLSCcalibrated POY error signal[Yuta, Jenne]
We have measured the out of loop
residual motion of the Yarm while locked
 LSC_POY_11_I_ERR_calib_19June2012.pdfPOY_calib_19June2012_FiltBankSettings.png 
  6841   Wed Jun 20 18:43:57 2012 yutaUpdateLSCcalibrated POX error signal[Jenne, Yuta]

We did the same calibration for POX.
 LSCxarmTF_usingITMX.pngLSCxarm_HAover1plusG.pngPOXerrorcalibration.png 
  6931   Fri Jul 6 14:10:31 2012 yutaSummaryLSCcalculation of FPMI using ALSFrom calculation, phase fluctuation of
reflected beam from length stabilized arm
is not disturbing MI lock.
  
  6947   Mon Jul 9 23:18:09 2012 yutaUpdateLSCPRMI got more stable a bitI modified filiters for LSC_MICH and LSC_PRCL.
Although modes we can see at POP and
AS look still bad, error signals are less
 LSCMICHOLTF.pngLSCPRCLOLTF.pngALL_1025928219_PRMIlocked3.pngPRMIbeammotion20120709.png 
  6949   Tue Jul 10 01:52:47 2012 KojiUpdateLSCPRMI got more stable a bitThe phase margins looks still too small.
Do You need such high gain at LF?
This is not a high finesse cavity so can
  
  6950   Tue Jul 10 03:16:17 2012 yutaUpdateLSCPRMI got more stable a bitI modified filiters for LSC_MICH and LSC_PRCL
again to cope with power recycling gain fluctuation.
After some more alignment, power recycling
 LSCMICHOLTF.pngLSCPRCLOLTF.pngPRMI20120709_2.png 
  6953   Tue Jul 10 21:37:05 2012 yutaUpdateLSCPRMI glitch studyPRMI
glitch certainly comes from power recylcing
gain fluctuation.
 PRMIgilitch20120709.pngPRMIgilitch20120709_closer.png 
  6954   Wed Jul 11 02:25:11 2012 yutaUpdateLSCPRMI beam spot motion might be from PRM/BS motionMy hypothesis from the measurements below,
to explain PRMI beam spot motion is;
 POPDCASDC4.pngFeedback4.pngOLPITYAWandPOPDC4.pngOLPITYAWandPOPDCunlocked.png 
  6955   Wed Jul 11 03:53:41 2012 yutaUpdateLSCBS 3.3 Hz motion on MIIt is not as dramatic as PRMI, but I could
see BS 3.3 Hz motion at AS and REFL when
MI is locked at dark fringe.
 REFLDCASDCMIlocked.png 
  6972   Thu Jul 12 23:15:34 2012 yutaUpdateLSCPRMI LSC is making PRM motion worseIt looks like PRMI LSC is making PRM motion (and
BS motion) at ~3Hz worse.
 PRMBSPRMIonoff.pngITMXITMYPRMIonoff.pngOplevPRMIonoff.png 
  6976   Sun Jul 15 16:25:15 2012 ranaUpdateLSCPRMI LSC is making PRM motion worseAs   
  7029   Wed Jul 25 15:33:55 2012 janoschUpdateLSCringdown measurementWe did our first ringdown measurement on
the Y arm. First we tried to keep the arm
locked in green during the ringdown, but
 Rindown1.png 
  7030   Wed Jul 25 16:31:01 2012 JenneUpdateLSCYarm green locking to arm - PDH box saturating

    

       
            
  
  7033   Wed Jul 25 22:16:36 2012 KojiUpdateLSCringdown measurementIs this the step response of the single
pole low pass???
It should have an exponential decay,
  
  7038   Thu Jul 26 13:10:51 2012 janoschUpdateLSCmodelled ringdownWe fitted shutter and ringdown functions
to the ringdown data. It is not perfectly
clear how the power change due to the shutter
 Ringdown.png 
  7039   Thu Jul 26 15:43:03 2012 ranaUpdateLSCmodelled ringdownYou cannot use the digital system for this.
You hook up a scope to the transmitted light
as well as the incoming light (after the
  
ELOG V3.1.3-