  7319   Thu Aug 30 17:03:32 2012 janosch, Manasa, SteveUpdate ETMXThe baffle has been moved away from ETMX
towards the edge of the table (in fact, it
is a little beyond the edge). It is also
  
  7318   Thu Aug 30 13:10:41 2012 jamieUpdateCamerasETMX

    

       
            
 etmx-face-baffle.png 
  7317   Thu Aug 30 12:01:27 2012 janosch, Manasa,SteveUpdate ETMXWe have done some work at ETMX today. We
installed the baffle and placed two
mirrors on the table.
  
  7316   Thu Aug 30 08:37:11 2012 SteveUpdateSUSETMX and ITMX needs more attention

    

       
            
 after4.1mAtm.pngeq4.1mAtm.png 
  7315   Thu Aug 30 08:12:39 2012 SteveUpdateGeneralIn vac plans for tomorrow, 8/30 
 1,PRM spot can be viewed directly
from the window south-east of ITMX chamber. 
  
  7314   Thu Aug 30 00:08:34 2012 jamieUpdateGeneralIn vac plans for tomorrow, 8/30

    

       
            
  
  7313   Wed Aug 29 21:02:45 2012 JenneUpdateIOOOptics between Faraday and PRM are centered, realigned[Jenne, Suresh, with support from Jamie
and Koji]
MC spots measured, MC1, MC3 no change.
  
  7312   Wed Aug 29 20:43:23 2012 KojiUpdateIOOSetup for a cavity scan or the input mode cleanerThe technique is based on detection of
the beating between the resonant carrier
and a resonant higher order mode.
  
  7311   Wed Aug 29 19:28:41 2012 Elli KingUpdateLSCSetup for a cavity scan or the input mode cleaner Riju, Elli
Today we prepared
our experimental setup to take a cavity scan
 40m_cavity_scan_diagram.jpg 
  7310   Wed Aug 29 17:35:34 2012 KojiUpdatePSLPower reduced!The biggest reason why we could not lock
the MC was that the beam was not properly hitting
  
  7309   Wed Aug 29 17:09:57 2012 jamieUpdateSUSETMX OK, free swingingETMX appears to be fine.  It was stuck
to its OSEMs in the usual way.  I touched
it and it dislodged and is now swinging freely. 
 Screenshot.png 
  7308   Wed Aug 29 17:02:41 2012 ericqUpdatePSLPower reduced!

    

       
            
  
  7307   Wed Aug 29 12:46:49 2012 SteveUpdateVACVent completed in 4 hrs 
 vent72.pngbeforeVentOpl.pngbeforeVent.png 
  7306   Wed Aug 29 11:47:21 2012 ericqUpdateVACVenting [Steve, Eric]
I've been helping Steve vent this
morning. The following things were done (from
  
  7305   Wed Aug 29 09:35:03 2012 janoschMetaphysicsRingdownripples 2Ok, so the whole idea that mirror motion
can explain the ripples is nonsense. At least,
when you think off the ringdown with
  
  7304   Tue Aug 28 20:23:54 2012 KojiMetaphysicsRingdownripples Laser frequency shift = longitudinal motion
of the mirrors
Ringing: http://www.opticsinfobase.org/ol/abstract.cfm?uri=ol-20-24-2463
  
  7303   Tue Aug 28 19:21:37 2012 janoschMetaphysicsRingdownripples Hmm. I don't know what ringing really
is. Ok, let's assume it has to
do with the pump... I don't see how
  
  7302   Tue Aug 28 19:06:32 2012 KojiMetaphysicsRingdownripples Isn't it just a ringing of the intracavity
power as you shifted the laser frequency
abruptly?
  
  7301   Tue Aug 28 18:28:21 2012 janoschMetaphysicsRingdownripples Let's see if the ripples observed
in the MC ringdown can be due to tilt
motion of the mirrors.
  
  7300   Tue Aug 28 17:59:03 2012 JenneUpdateVACVENT: GO!I have turned of the high voltage supplies
for PZT1 and PZT2.  The OMC PZT high
voltage supplies were already off, since
  
  7299   Tue Aug 28 17:51:39 2012 JenneUpdatePSLPBS and Half Wave plates introduced

    

       
            
  
  7298   Tue Aug 28 17:43:04 2012 JenneUpdatePSLPower reduced!

    

       
            
  
  7297   Tue Aug 28 17:16:54 2012 ericqUpdatePSLPower reduced!We have now reduced the power being
input to the MC from 1.25W to 10mW, and changed
out the MC refl BS for a mirror. 
  
  7296   Tue Aug 28 17:02:16 2012 jamieUpdateGeneralsvn commit changesI just spent the last hour checking in
a bunch of uncommitted changes to stuff in
the SVN.  
  
  7295   Tue Aug 28 16:27:22 2012 ericqUpdatePSLPBS and Half Wave plates introduced[Jenne, Eric]
We installed a Half Wave Plate ->
Polarized Beam Splitter -> Half Wave Plate
  
  7294   Tue Aug 28 11:28:31 2012 ericqUpdatePSLPMC alignment going bad

    

       
            
  
  7293   Tue Aug 28 09:37:33 2012 SteveUpdateVACRGA scan at day 56RGA scan,  Maglev pumping speed at
day 56
CC1 is dying. CC4 is real.
 pd72m56d.pngpd72m56dpr.png 
  7292   Tue Aug 28 00:23:54 2012 JenneUpdatePSLPMC alignment going badPMC transmission started going down this
afternoon, around 3pm-ish.  Right now
it's 0.775, which is very, very low. 
 PMC_transmission_GoingDown_27Aug2012.png 
  7291   Tue Aug 28 00:16:19 2012 jamieUpdateGeneralAlignment and vent prepI think we (Jenne, Jamie) are going to
leave things for the night to give ourselves
more time to prep for the vent tomorrow.
 as1.png 
  7290   Mon Aug 27 23:52:59 2012 JenneUpdateIOOMC Spots centeredFinally!
Jamie and I have the MC spots centered. 
We did the normal move the input beam, realign
 MCdecenter_26Aug2012.png 
  7289   Mon Aug 27 18:59:24 2012 jamieUpdateIOOMC ASC screen was confusing - Jenne is not stupid

    

       
            
 Screenshot-1.pngScreenshot-2.png 
  7288   Mon Aug 27 18:32:48 2012 JenneUpdateIOOMC spot position - Jenne is stupid

    

       
            
  
  7287   Mon Aug 27 17:14:00 2012 jamieUpdateCDSc1oaf problem

    

       
            
  
  7286   Mon Aug 27 15:49:46 2012 JenneUpdateSUSEQ damage

    

       
            
  
  7285   Mon Aug 27 15:46:55 2012 SteveUpdateSAFETYsafety training Rijuparna                 Chakraborty
and Elli Elenora King received 40m specific 
basic safety training in the 40mLab
 IMG_1597.JPG 
  7284   Mon Aug 27 12:03:54 2012 KojiUpdateIOOMC spot position - callin' it quitsThe MC REFL path was checked. ==> Some
clippings were fixed. MC WFS is working now.
- MC was aligned manually
  
  7283   Mon Aug 27 10:49:03 2012 KojiUpdateSUSEQ damageAfter shaking ITMX by the alignment bias
in yaw, it came back.
As ETMX seems to be largely misaligned
  
  7282   Mon Aug 27 09:24:17 2012 SteveUpdateSUSEQ damage  It looks like we may lost 1 (or
3 )  magnets? Do not panic, it's not
for sure
 eqDamage.png 
  7281   Mon Aug 27 08:34:18 2012 SteveUpdatePEMearthquakesShasky
day yesterday postpones venting. We had
about 11 shakes larger than mag 4.0 Mag5.5
 eq5.5Msaltonsea.pngM5.5inaction.pngEQeffect.png 
  7280   Mon Aug 27 01:05:36 2012 JenneUpdateIOOMC spot position - callin' it quitsspot positions in mm (MC1,2,3 pit MC1,2,3
yaw):
[-0.98675603448324423, -0.94064212026141558,
 MCdecenter_26Aug2012.png 
  7279   Sun Aug 26 21:47:50 2012 KojiUpdateCDSC1LSC oozeI came in to the lab in the evening and
found c1lsc had "red" for FB connection.
I restarted c1lsc models and it kept
  
  7278   Sun Aug 26 20:58:21 2012 JenneUpdateVACDon't vent!!!![Koji, Jenne]
Steve, do not vent tomorrow morning! 
We are still not prepared, and will not finish
  
  7277   Sun Aug 26 12:26:44 2012 JenneUpdateIOOMC spot position - not done yet

    

       
            
  
  7276   Sun Aug 26 11:53:09 2012 JenneUpdateIOOMC2 getting kicked up regularlyWe need to re-look at this new MC autolocker
stuff, and the new MCL filters.
MC2 is getting kicked up (sometimes
  
  7275   Fri Aug 24 22:01:15 2012 JenneUpdateIOOMC spot position - closeI am getting closer with the MC spot centering. 
I had everything but MC1 really great, but
then I tweaked MC1's pointing, and things
 MCdecenter_24Aug2012.png 
  7274   Fri Aug 24 21:00:40 2012 KojiUpdateLSCX end green investigationI checked and fixed the X end green situation.
Now
the X green beam is locked with TEM00.
  
  7273   Fri Aug 24 20:48:10 2012 KojiUpdatePSLPMC alignedas usual.   
  7272   Fri Aug 24 16:03:39 2012 SteveUpdateVACVacuum related work at atmVacuum related work at atmosphere:
Atm1,  Check all chamber dog
clamps tightness with torque wrench,
 IMG_1563.JPGIMG_1565.JPGIMG_1566.JPG 
  7271   Fri Aug 24 14:46:08 2012 JenneSummaryGeneralDetailed alignment planFriday / pre-vent:
[done]
Align the MC mirrors for the incident
  
  7270   Fri Aug 24 13:22:19 2012 DenUpdateModern Controlcavity simulationI did a simulation of a cavity, feedback
signal was calculated using LQG controller.
I assumed that there is not length ->
 model.pngcontroller.pngcavity_lqg.pngcavity.png 