  10605   Tue Oct 14 17:38:31 2014 ericqUpdateComputer Scripts / ProgramsRossa and Allegra wiped, Ubuntu 12.04 installedWhen I came in, Rossa was booted to Ubuntu
10. I tried rebooting to select 12, but couldn't
ever successfully boot again. Since Diego
  
  10613   Wed Oct 15 20:10:29 2014 ericqUpdateLSCInterim DARM SignalI've done
some preliminary modeling to see if there
is a good candidate for an 
 7x 
  10617   Thu Oct 16 12:22:43 2014 ericqUpdateCDSDaqd segfaulting againI've been trying to figure out why daqd
keeps crashing, but nothing is fixed yet. 
I commented out the line in /etc/inittab
  
  10618   Thu Oct 16 16:21:42 2014 ericqUpdateLSCInterim DARM SignalI've added
(TRX-TRY)/(TRX+TRY) to the DC DARM sweep
plots, and it looks like an even better candidate.
 dcDARMSweep-300.pdfdcDARMSweep-120.pdfdcDARMSweep-50.pdfdcDARMSweep-0.pdf 
  10621   Fri Oct 17 03:05:00 2014 ericqUpdateLSCDARM locked on DC Transmission difference I've
been able to repeatedly get off of ALS and
onto (TRY-TRX)/(TRY+TRX). Nevertheless, lock
 TRdifflock.pngOct17lock.pdf 
  10627   Tue Oct 21 00:38:40 2014 ericqUpdateLSCsweep + RMS as uncertainty

    

       
            
 dcCARMSweep_uncertainties.png 
  10635   Thu Oct 23 13:08:55 2014 ericqUpdateGeneralGap in local Chiara backupsAfter the second of the two recent power
outages, the outlet powering Chiara's external
drive for local backups didn't come back.
  
  10641   Mon Oct 27 19:15:54 2014 ericqUpdateLSCTrying to PRMI on 165I spent some time trying to debug our inability
to get MICH onto REFL165Q while the arms
are held off with ALS, to no real success. 
  
  10647   Tue Oct 28 15:27:25 2014 ericqUpdateIOOIMC WFS sensing matrix measurement I took some spectra of the error
signals and MC2 Trans RIN with the loops
off
 45.png 
  10649   Wed Oct 29 03:33:38 2014 ericqUpdateLSCTrying to PRMI on 165 
Short report: Further frustrated
by 165 tonight. The weird thing is, the procedure
  
  10655   Thu Oct 30 16:25:22 2014 ericqOmnistructureComputer Scripts / Programsnew version of cdsutils (361) installed

    

       
            
  
  10656   Fri Oct 31 02:19:37 2014 ericqUpdateLSCSome SRMI progressEarlier today, I did some simulations that
suggested that PRC lengths on the order of
a cm from our current estimated one could
  
  10662   Mon Nov 3 17:14:00 2014 ericqUpdateASCIMC to IFO angular motionSomething to note, as we have the IMC angular
controls under consideration:
Jenne has the DRMI locked right now.
 2014-10-03-MC2T_to_POPQPD.pdf 
  10667   Tue Nov 4 19:17:53 2014 ericqUpdateComputer Scripts / ProgramsAnaconda + CDSutilsI've fallen down the rabbit hole of trying
to reconcile our desire for newer versions
of the Numpy and Scipy python packages with
  
  10668   Wed Nov 5 01:58:54 2014 ericqUpdateLSC3F RFPD RF spectraGiven the checkout of the aLIGO BBPDs happening
(aLOG
link), wherein the PDs were acting funny,
 Nov52014_3fPD_DRMIspectra.zipREFL165_DRMIspectrum.pngREFL33_DRMIspectrum.png 
  10672   Wed Nov 5 18:08:00 2014 ericqUpdateLSCPSL and AUXY beatnote in IR foundGreen beatnotes   
  10673   Wed Nov 5 22:25:42 2014 ericqUpdateLSC3F RFPD RF spectra 
Now that I have followed the chain,
the PD signal is indeed being amplified at
 REFL165_demod_DRMIspectrum.png 
  10679   Thu Nov 6 11:49:58 2014 ericqUpdateLSC3F RFPD RF spectra

    

       
            
  
  10683   Fri Nov 7 02:21:12 2014 ericqUpdateLSC3F RFPD RF spectra 
After some enlightening conversation
with Koji, we figured that the RF amplifier
  
  10685   Fri Nov 7 14:41:18 2014 ericqUpdateLSC3F RFPD RF spectra

    

       
            
 165_ampSaturation.png165_HPatPD.png 
  10690   Sat Nov 8 16:01:32 2014 ericqConfigurationLSCDRMI sensingHere are some preliminary results from
the sensing sweeps I did the other night. 
Notes:
 6x 
  10692   Mon Nov 10 18:11:57 2014 ericqUpdateLSC3F RFPD RF spectra Jenne and I measured the situation
using a SHP-150 directly attached to the
REFL165 RF output, and at first glance, the
 165signals.pdf 
  10693   Mon Nov 10 18:23:10 2014 ericqConfigurationLSCDRMI sensingARG, I accidentally permuted the digital
demod angles. This significantly weakens
the argument for believing AS55I is broken...
 REFL11.pngREFL33.pngREFL55.pngREFL165.pngAS55.png 
  10699   Wed Nov 12 00:55:56 2014 ericqUpdateLSCNotch at 110MHz

    

       
            
 165_Notched.pdf 
  10700   Wed Nov 12 01:30:39 2014 ericqUpdateLSCDRFPMI, PRFPMI HOM resonancesI did some simulations to see if we are
susceptible to HOM resonances as we reduce
the CARM offset. I restricted my search to
 HOMs.zipDRFPMI_HOMscan.pngPRFPMI_HOMscan.png 
  10705   Wed Nov 12 21:18:32 2014 ericqUpdateLSCDRFPMI, PRFPMI HOM resonancesSo, with my last entry, I was guilty of
just throwing stuff into the simulation and
not thinking about physics... so I retreated
 HOMlist.py.zip 
  10713   Fri Nov 14 02:43:05 2014 ericqUpdateLSCPRFPMI HOM resonancesI've extended my analysis to the PRFPMI
case, with the current working knowledge
of radii of curvature and cavity lengths.
 HOMcurves.pdfHOMpeaks.pdfprfpmiHOM.zip 
  10720   Fri Nov 14 20:31:13 2014 ericqUpdateLSCRIN in transmission a problem?I took a quick look at single arm RIN.
Actuating on MC2 vs. the ETM, or using AS55
instead of POY11 made no noticeable difference
  
  10729   Fri Nov 21 02:22:25 2014 ericqUpdateLSCMore ALS PRFPMI exploration Similar to what Jenne did the other
night, I kept the PRFPMI arm DoFs locked
on ALS, in hopes to check out the RF error
  
  10731   Fri Nov 21 13:58:51 2014 ericqUpdateOptical LeversHeNe RIN test Steve had me measure the RIN of a
JDSU HeNe laser. I used a PDA520, and measured
the RIN after the laser had been running
 2014-11-21_HeNeRIN.zipRIN_P893519.pdf 
  10735   Tue Nov 25 14:52:14 2014 ericqUpdateOptical LeversOpLev RINs At Rana's request, I've made an in-situ
measurement of the RIN of all of our OpLevs.
PSL shutter closed, 10mHz BW. The OpLevs
 RIN.pdf 
  10744   Mon Dec 1 20:12:52 2014 ericqUpdateModern ControlRebirth of CESAR / ESCOBAR I've uploaded a note at T1400735 about  gssimSweep.pdf 
  10754   Thu Dec 4 02:59:05 2014 ericqUpdateLSCBump in Darm Plant[J,Q]
After some housekeeping (ASS is wonky,
alignment of X green beat was bad, tuning
 Dec4_darmbump.pdf 
  10783   Thu Dec 11 17:45:54 2014 ericqUpdateComputer Scripts / ProgramsLockloss plotting With some advice from Jamie, I've
gotten the lock loss plotting script that
is used at LHO working on our machines. The
 figure.png 
  10784   Thu Dec 11 18:00:43 2014 ericqUpdateComputer Scripts / ProgramsMC error signal monitoringThe other day, I hooked up the agilent
analyzer to OUT2 of the MC board, which is
currently set to output the MC refl error
  
  10785   Thu Dec 11 18:12:46 2014 ericqUpdateLSC(Fixed) Y end whitening board

    

       
            
  
  10796   Sat Dec 13 14:26:36 2014 ericqUpdateLSCMismatched gains on ETMY Transmon QPDYesterday, we were seeing anomalously high
low frequency RIN in the y-arm (rms of 4%
or so). I swung by the lab briefly to check
  
  10797   Mon Dec 15 12:53:13 2014 ericqUpdateComputer Scripts / ProgramsStatus of the new nodus Nodus
(solaris) is dead, long live Nodus (ubuntu).
  
  10809   Wed Dec 17 13:14:38 2014 ericqUpdateLSCPRMI loops need help

    

       
            
 oops.pdf 
  10811   Wed Dec 17 18:14:36 2014 ericqUpdateASCTransmon QPD -> ASC servos ready for comissioning I have completed all of the model
modifications and medm screen updates to
allow for feedback from the  transmon QPD
 newASCscreen.png 
  10814   Thu Dec 18 02:23:34 2014 ericqUpdateLSCLocking update [ericq, Diego]
Some locking efforts tonight; many
locklosses due to PRC angular motion. Furthest
 15lockloss.png15spec.pdf 
  10815   Thu Dec 18 15:41:30 2014 ericqUpdateComputer Scripts / ProgramsOffsite backups of /cvs/cds going againSince the Nodus switch, the offsite backup
scripts (scripts/backup/rsync.backup) had
not been running successfully. I tracked
  
  10816   Thu Dec 18 16:21:08 2014 ericqUpdateComputer Scripts / Programsscripts not being backed up! I just stumbled upon this while poking
around:
Since the great crash of June 2014,
  
  10819   Fri Dec 19 16:39:25 2014 ericqUpdateComputer Scripts / Programselog autostartI've set up nodus to start the ELOG on
boot, through /etc/init/elog.conf.
Also, thanks to this, we don't need to use
  
  10820   Fri Dec 19 16:59:32 2014 ericqUpdateComputer Scripts / ProgramsFSS Slow servo moved to megatronGiven that op340m showed some undesired
behavior, and that the FSS slow seems prone
to railing lately, I've moved the FSS slow
  
  10825   Sat Dec 20 00:00:03 2014 ericqUpdateComputer Scripts / ProgramsFSS Slow servo moved to megatronI ssh'd in, and was able to run each script
manually successfully. I ran the initctl
commands, and they started up fine too. 
  
  10830   Mon Dec 22 16:21:15 2014 ericqUpdateelogStrange ELOG searchIn order to fix ELOG search, I have started
running ELOG v2.9.2 on Nodus.
Sadly,
  
  10835   Tue Dec 23 14:27:16 2014 ericqUpdateCDSChiara moved to UPS Steve and I switched chiara over
to the UPS we bought for it, after ensuring
the vacuum system was in a safe state. Everything
  
  10836   Tue Dec 23 14:30:11 2014 ericqUpdateCDSChiara moved to UPS

    

       
            
  
  10839   Tue Dec 23 16:49:32 2014 ericqUpdateelogStrange ELOG search So, despite having registered users,
it turns out that the "Author"
field is still open for editing when making
  
ELOG V3.1.3-