ID |
Date |
Author |
Type |
Category |
Subject |
7511
|
Tue Oct 9 17:16:14 2012 |
Den | Update | SUS | diagonalization |
I went inside to align the beam on WFS and noticed that oscillations in yaw are ~10 times stronger then in pitch. I've plot rms of pitch and yaw measured by LID sensors and saw that MC3 yaw rms motion is a few times larger then pitch.
Also MC1 input diag matrix does not diagonalize signals for pitch and yaw. In the spectrums of these signals all 4 resonance are equally seen during the free swinging. I think we should rediagonalize MC1.
Another thing is that if MC1 and MC3 are on the same stack, pitch and yaw spectrums of these mirrors should be comparable. But MC1 signal is ~2-3 times larger then of MC3. I think we should correct calibration. |
7510
|
Tue Oct 9 09:29:10 2012 |
Steve | Update | IOO | this is where we are |
Quote: |
Quote: |
The new cold cathode gauge CC1 is in place. We were at atmosphere for 28 days ......more later
|
cc1 = 2.3e-5 Torr at day 6 vacuum normal
|
|
7509
|
Tue Oct 9 00:25:33 2012 |
Jenne | Update | IOO | PZTs - hacky solution in place!! |
[Evan, Jenne]
We applied some volts across both the pitch and yaw pin sets of the ribbon cable that goes to PZT2. We ended up with ~40V yaw and ~14.5V pitch. That was the nice happy center of the clipping that we can see on the AS camera. Once we found the center of the PZT clipping range with the ITMY beam, we recentered the AS camera (actually, this took a few iterations, but now it's good).
We then aligned MICH, but aren't able to get it to lock. Before falling asleep, we have decided to align the PRM and SRM, so right now we have a flashing DRMI. Both the SRMI and PRMI look a little funny the closer you get to 'good' alignment, so I'll investigate a little more tomorrow, and include pictures. (The video capture script has barfed again, and I'm not in the mood to deal with it today.) |
7508
|
Mon Oct 8 23:58:57 2012 |
Jenne | Update | SAFETY | Control room emergency lights came on |
[Evan, Jenne]
We were sitting trying to lock MICH (hooooorraaaayy!!!), and the emergency lights above the control room door came on, and then ~1 minute later turned off. Steve, can you see what's up? |
7507
|
Mon Oct 8 22:07:46 2012 |
rana | Update | SUS | Doors on, ready to pump |
Quote: |
All oplevs need a little realignment, especially ETMY, which had it's lens removed (Rana has a Wall of Shame photo of this, which is why it was removed by him). Steve will look into this tomorrow, after he starts pumping.
|
The shame:

There is no situation in which it is OK to install a mount like this. Steve had installed this flaky and shaky mount to optimize the beam size on the OL QPD.
Everyone in the lab should know better. Putting in something like this is just like sabotage - it creates extra noise in our interferometer in a sneaky way and just makes locking harder. All mounts for anything useful (including QPDs) must have highly rigid mounts.
Use the example from the PSL relayout: use the 3/4" steel mounts and the wide aluminum bases from Newport. No more art projects using home made mounting crap, Steve. |
7506
|
Mon Oct 8 21:42:17 2012 |
Jenne | Update | IOO | PZT diagnosis - not fixed yet, possible solution |
Note to self:
The ENV-40 amplifiers that we have supply -10V through +150V .... so don't exceed those limits.
piezojena link |
7505
|
Mon Oct 8 18:45:48 2012 |
Jenne | Update | IOO | PZT diagnosis - not fixed yet, possible solution |
After the fuse-blowing fiasco earlier this afternoon, Koji and I took another look at the PZT controllers.
We put an ammeter in place of the fuse, and watched the current as we turned on the transformer module. The steady-state current with no other modules plugged in is ~15mA. However, there is a surge current right when you turn on the box which sometimes goes as high as 330mA. Since the fuse is 250mA, this explains the fuse blowing, even though Koji had already checked out the low voltage path.
The high voltage line was connected, with +180V to the HV out pin of the backplane connector, and the (-) terminal of the power supply connected to signal ground on the board.
We inserted the PITCH module for PZT2, and we started with ~10V as our "high" voltage, and slowly increased the value (current at this time was ~60mA). We also had a function generator plugged into the "MOD" input, which is where the epics slider goes, so that we should see a changing output voltage. We never saw a changing output voltage. Increasing the HV power supply didn't help.
When Koji spun the "DC offset" knob really fast and then stopped, sometimes the output voltage as measured on the connector-converter board between the white and red wires would jump up, and then settle back down. It came back to the same value that it always was, but it was bizzarre that it would jump like that. We suspect that that knob is an offset for use with the closed loop setting, so it isn't relevant for us anyway. Watching the MON output, the value never changed, even when Koji did his fancy knob twirling.
We switched to the other PITCH module, and watched the output voltage on the MON output. This time, with the function generator unplugged, so no modulation input (so we were expecting a steady DC output voltage) the number on the LCD and the MON output fluctuated wildly. We plugged in the function generator, and the fluctuations did not change in approximate amplitude or DC offset. They kind of looked the same.
So, we have concluded that (a) the PZT drivers don't work, and (b) we don't understand why. Therefore, we don't know how to fix them.
With that in mind, we are thinking of totally circumventing the PZT drivers.
I plugged in the PZT1 connector converter board, which has Koji's circuit that he made last time when PZT1 died. I plugged the ribbon cable which goes to the PZT, and the +\- 30V power supply, and the PZT responded! Just plugging in the power supply puts the PZTs near the center of their nominal range. I then put a function generator on the epics inputs for pitch and yaw (one at a time), and saw the spot move around at the ~1Hz that I was applying. Yay!
What I think I'll do for tonight - modify the other connector converter board so that I can just use 2 HV power supplies (current limited) to steer the PZT. I set up a TV monitor next to the PZT electronics (1Y3? 1Y4? I forget), and it's connected to output 20 of the video switch, so I can watch the AS camera and move the PZTs by hand. Then maybe I can try to align some stuff. (Evan is coming to work tonight, so if I electrocute myself, someone will be here to call 5000) Koji suggested buying 2 single-channel thorlabs piezo drivers, like we have on the PSL table for the FSS loop. These take in 0-10V and output either 0-75V, 0-100V or 0-150V (depending on which setting you choose). These cost $712 each. This would be a more permanent solution than me just sitting out there, since we could once again control PZT2 via epics.
|
7504
|
Mon Oct 8 14:19:17 2012 |
Jenne | Update | IOO | PZT diagnosis - not fixed yet |
Quote: |
What I will do tomorrow (when there is someone here to rescue me if I crispy-fry myself) is solder a wire to the now open pin of the backplane connector on the HV driver board, so that we can supply an external 180V to the pitch / yaw modules (although, obviously we won't be using the burnt yaw modules as-is). Tomorrow I'll start by applying a nice small voltage, check that things still look okay, no shorts, and then I'll slowly increase the voltage until I get to the nominal 180V.
|
I connected a thick wire to pin 22 of the backplane connector of the transformer / power supply module of the PZT box. This is the pin that +180V is supposed to go on, to be distributed to the other boards in the crate. Last week I had drilled a hole in the front panel so the wire can come out (since no one on campus seems to have HV panel mount connectors in stock).
While the transformer module was isolated, not touching anything else, I applied (slowly ramping up) 180V DC, and it all looked good.
When I plugged the module back into the crate (first turning off and disconnecting the HV), I blew the 250mA fuse again. No HV yet, just the low voltage stuff that Koji had fixed last week. :(
We're now out of 250mA fuses, we're supposed to get a box of them tomorrow. |
7503
|
Mon Oct 8 12:34:52 2012 |
Den | Update | Modern Control | state estimation |
Quote: |
I guess that the estimated state has the same low pass filter, effectively, that we use to low pass the feedback signal in SUSPOS. I wonder if there is an advantage to the state estimation or not. Doesn't the algorithm also need to know about the expected seismic noise transmission from the ground to the optic?
|
I think state estimation and optimal control are two different techniques that are often used together. Sometimes (as for pendulum) we can use LQG without state estimation as we need only position and velocity. But for more complex systems (like quad suspension) the states of all 4 masses can be reconstructed in some optimal way using information from only one of them if the dynamics is sufficiently well known. When current system states are measured/estimated we can apply control where all our filters are hidden.
The algorithm needs to know about expected seismic noise transmission from the ground to the optic, but it might be not very precise. I gave it some rough estimate, there are better ways to do it. I think that we'll understand whether we need state estimation or not when we'll move to more complex systems. Brett uses a similar approach for his modal control. Interesting if these methods + seismometer readings will be able to say if one of your sensors is noisier then others.
|
7502
|
Mon Oct 8 11:44:21 2012 |
Jenne | Update | SUS | ETMX slow machine fine |
Quote: |
I think the ETMX slow machine might be dead. All of the regular FE readbacks are fine, and the c1iscex FE computer looks fine, but the slow readbacks are all whited out.
I turned off the damping loops for ETMX, since I don't have access to the watchdog disable/enable switch. I guess checking this out will be task #1 for Monday morning.
|
For lack of a better idea, I keyed the crate. The computer came back up just fine, ETMX is happily damped again. |
7501
|
Mon Oct 8 11:15:53 2012 |
Jenne | Update | PSL | PMC and FSS had a weird weekend |
Something bizarre-o was going on with the PMC and FSS over the weekend. On the striptool, PMC's PZT looks like it was doing a sawtooth pattern for several hours. I opened up the FSS screen, and the FSS SLOWDC had walked itself up to +10. It's not supposed to get that far from 0.
Here are some trends, so you can see what was going on.
10 day trend: This weird behavior began ~Friday evening (FSS_SLOWDC ramps quickly).

1 day trend: You can see the sawtooth pattern in PMC_PZT more clearly here. It's at the same time as the FSS_SLOWDC is ramping rapidly, and the FSS_FAST is saturated.

|
7500
|
Mon Oct 8 10:56:59 2012 |
Jenne | Update | SUS | ETMX slow machine dead?? |
I think the ETMX slow machine might be dead. All of the regular FE readbacks are fine, and the c1iscex FE computer looks fine, but the slow readbacks are all whited out.
I turned off the damping loops for ETMX, since I don't have access to the watchdog disable/enable switch. I guess checking this out will be task #1 for Monday morning. |
7499
|
Mon Oct 8 09:51:30 2012 |
rana | Update | Modern Control | state estimation |
I guess that the estimated state has the same low pass filter, effectively, that we use to low pass the feedback signal in SUSPOS. I wonder if there is an advantage to the state estimation or not. Doesn't the algorithm also need to know about the expected seismic noise transmission from the ground to the optic? |
7498
|
Mon Oct 8 09:45:28 2012 |
jamie | Update | Computers | Rebooted cymac0 |
Quote: |
I rebooted cymac0 a couple of times. When I first got here it was just frozen. I rebooted it and then ran a model (x1ios). The machine froze the second time I ran ./killx1ios. I've rebooted it again.
|
For context, there's a is stand-alone cymac test system running at the 40m. It's not hooked up to anything, except for just being on the martian network (it's not currently mounting any 40m CDS filesystems, for instance). The machine is temporarily between the 1Y4 and 1Y5 racks. |
7497
|
Sun Oct 7 23:39:10 2012 |
Den | Update | Modern Control | state estimation |
I've applied online state estimation technique using Kalman filter to LQG controller. It helps to estimate states that we do not measure. I've considered MC2 local damping, we measure position and want to estimate velocity that we need for control. We can either differentiate the signal or apply state estimation to avoid huge noise injection at high frequencies. In state estimation we need to know noise covariance, I've assumed that LID sensor noise is 0.1 nm. Though covariance can be calculated better.
In the time-domain figure C1:SUS-MC2_SUSPOS_IN1 = MC2 postion, C1:SUS-MC2_SUSPOS_OUT = MC2 velocity obtained by differentiation, 2 other channels are estimations of position and velocity. |
7496
|
Sun Oct 7 15:05:42 2012 |
Den | Update | SUS | MC2 sus damping restored |
Quote: |
This is the third morning in a row that the MC2 was tripped.
|
MC2 was tripped again. I think the answer is that watchdog's critical value was too small C1:SUS-MC2_PD_MAX_VAR = 10, so seismic could trip MC2. I've changed the value to 100.

|
7495
|
Sun Oct 7 12:11:00 2012 |
Aidan | Update | Computers | Rebooted cymac0 |
I rebooted cymac0 a couple of times. When I first got here it was just frozen. I rebooted it and then ran a model (x1ios). The machine froze the second time I ran ./killx1ios. I've rebooted it again. |
7494
|
Fri Oct 5 18:08:17 2012 |
Manasa | Configuration | PSL | AOM installation |
Quote: |
Do more investigation to understand what is causing the power reduction.
Is the alignment inadequate? Check the in-lock ccd image.
Is the incident power reduced? (by what?) Use dataviewer.
Is the AOM doing something? Is it active? Then how much power is it eating?
BY THE WAY, how the deflected beam is dumped?
If you don't have anything for blocking the 1st order beam, you have to expect Steve coming to you.
|
The PMC has been aligned and is all happy happy 
I have installed an iris to dump the higher order beams deflected by the AOM. After installing the iris, I found that the PMC trans dropped to 0.58V and the PMC misaligned in pitch. So I've touched the 2 steering mirrors before the PMC. Now it is satisfactorily locked with PMC trans at 0.84.
I have also checked the alignment with AOM switched on. PMC trans drops to 0.15 with AOM on and comes back to 0.84 when AOM is switched off without losing lock . |
7493
|
Fri Oct 5 16:21:48 2012 |
Steve | Update | General | freshmen visiters |
40 plus freshmen visited the 40m today |
7492
|
Fri Oct 5 14:53:29 2012 |
Jenne | Update | PSL | TTFSS board not fully seated! |
[Den, Jenne]
Den noticed that the -15V LED on the TTFSS board was not illuminated. A further symptom of the FSS being funny was that the PC RMS Drive was constantly high (3.6 ish) and the FAST Monitor was very high, often saturated.
We took the TTFSS board out, and put an extender card in, and it looked like all of the correct power is being supplied to the board (the +\- 24V LEDs on the extender card were illuminated). Just to check, we put the board back in, and this time both +\- 15V LEDs came on. So it looks like the board is fine, it just wasn't seated in there all the way.
Now the readbacks on the FSS screen look good (PC RMS Drive is less than 1, FAST Mon is 5ish), the MC is locked, and I think we're back in business.
|
7491
|
Fri Oct 5 14:40:55 2012 |
Steve | Update | VAC | RGA scan after power outage |
Quote: |
All the front end machines are back up after the outage. It looks like none of the front end machines came back up once power was restored, and they all needed to be powered manually. One of the things I want to do in the next CDS upgrade is put all the front end computers in one rack, so we can control their power remotely.
c1sus was the only one that had a little trouble. It's timing was for some reason not syncing with the frame builder. Unclear why, but after restarting the models a couple of times things came back.
There's still a little red, but it mostly has to do with the fact that c1oaf is busted and not running (it actually crashes the machine when I tried to start it, so this needs to be fixed!).
|
The RGA was not effected by the short power outage. |
7490
|
Fri Oct 5 11:11:00 2012 |
Den | Update | PEM | readout box power |
Quote: |
Guralp readout box received +13.7 /0/ -15V instead +15V because of the broken fuse. Power provided by the source is normal.
Edit by Den: I've found a similar fuse on one of the tables and borrowed it. Guralp is not working again.
|
I've meant Guralp is NOW working again  |
7489
|
Fri Oct 5 04:34:31 2012 |
rana | Update | SUS | How about the slow machines? |
Quote: |
Quote: |
Based on the elog entries, I assume they have not been burtrestored...
|
Do you know how to burtrestore or restart slow machines?
Edit by Den: I did burtrestore of c1psl.snap from 2 days ago. Still slow machines behave not normal. For example, if I sweep C1:PSL-FSS_SLOWDC, SLOW monitor value does not change.
|
Problems with Slow Machines?
Read ELOG |
7488
|
Fri Oct 5 01:36:49 2012 |
Den | Configuration | PEM | changed PEM DQ channels |
Quote: |
We should do this wherever possible so that our channels will have real calibrations associated with them.
Next we should up the rate at which the model runs up to 16 kHz so that we can record the microphones at 16 kHz. FM radio has information up to 20 kHz. AM radio goes up to ~8 kHz. We should be at least as modern as AM radio. How do we make the change? How do we make sure the FOTON file stays OK?
|
I've added calibration gains to Guralp (to um/sec) and EM172 (to Pa) channels.
We can run PEM at 16 kHz. I think Foton file stores both sos-representation and filter commands which are independent of the sampling frequency, so it should be possible to change model sampling frequency quickly.
In fact, we can save data at 64 kHz from iop models. I've done this once with MC_F channel. However, I did not test EM172 noise at frequencies > 1 kHz. |
7487
|
Fri Oct 5 00:29:34 2012 |
Den | Update | PEM | readout box power |
Guralp readout box received +13.7 /0/ -15V instead +15V because of the broken fuse. Power provided by the source is normal.
Edit by Den: I've found a similar fuse on one of the tables and borrowed it. Guralp is not working again. |
7486
|
Thu Oct 4 23:01:49 2012 |
Rijuparna | Configuration | | cavitymode scan |
Here I am attaching the schematic diagram of the experimental set-up for IMC cavitymode scanning. A 30- 45MHz scanning signal generated by Agilent 4395A network analyzer enters EOM, which in turn modulates the laser beam entering IMC. The cavity response can be verified from reflected/transmitted beam.
I worked with the reflected beam last days. But I got no clue about the percentage of reflected light reaching the photodiode and also the photodiode response. I would like to measure the power reaching photodiode and also would like to perform the test with transmitted beam - on wednesday if possible.
|
7485
|
Thu Oct 4 22:35:16 2012 |
Den | Update | SUS | How about the slow machines? |
Quote: |
Based on the elog entries, I assume they have not been burtrestored...
|
Do you know how to burtrestore or restart slow machines?
Edit by Den: I did burtrestore of c1psl.snap from 2 days ago. Still slow machines behave not normal. For example, if I sweep C1:PSL-FSS_SLOWDC, SLOW monitor value does not change. |
7484
|
Thu Oct 4 22:27:54 2012 |
Koji | Update | SUS | How about the slow machines? |
One terrible concern of mine is that the slow machines were rebooted at the power interruption.
Based on the elog entries, I assume they have not been burtrestored...
If this is true, they may cause some weird behaviors of the PSL/IOO electronics.
|
7483
|
Thu Oct 4 22:16:40 2012 |
Den | Update | PSL | PMC is locked |
PZT monitor is not lying to us, I've measured it with a voltmeter. But PMC SERVO is still interesting. If I break the loop after PMCERR signal monitor (C1:PSL-PMC_BLANK=0), I can change PZT voltage from 0V (C1:PSL-PMC_RAMP = -7.3) to 132V (C1:PSL-PMC_RAMP=-10.0). If I break the loop by enabling TEST1, PZT voltage goes up to 294 V, though voltage on the TEST1 and MIXER MON is 0. |
7482
|
Thu Oct 4 22:16:28 2012 |
Koji | Configuration | PSL | AOM installation |
Do more investigation to understand what is causing the power reduction.
Is the alignment inadequate? Check the in-lock ccd image.
Is the incident power reduced? (by what?) Use dataviewer.
Is the AOM doing something? Is it active? Then how much power is it eating?
BY THE WAY, how the deflected beam is dumped?
If you don't have anything for blocking the 1st order beam, you have to expect Steve coming to you. |
7481
|
Thu Oct 4 20:57:43 2012 |
Manasa | Configuration | PSL | AOM installation |
Quote: |
Quote: |
Jenne and Jamie also find that the PMC is behaving very weird 
|
Can someone detail what "weird" means? Is it singing old songs from Guns & Roses?
|
It isn't singing Jan..it's dancing between 0.7 to 0 and we are not able to figure out whose the DJ ; there seems to be something else that is controlling the PMC as there is no coordination between what we do (tweaking the mirrors) and what we observe (the PD signals). |
7480
|
Thu Oct 4 18:48:04 2012 |
janosch | Configuration | PSL | AOM installation |
Quote: |
Jenne and Jamie also find that the PMC is behaving very weird 
|
Can someone detail what "weird" means? Is it singing old songs from Guns & Roses? |
7479
|
Thu Oct 4 17:54:59 2012 |
Manasa | Configuration | PSL | AOM installation |
Quote: |
After the AOM work the beam wasn't well aligned to the PMC. The PMC REFL CCD shows large misalignment in yaw.
|
{Jan, Manasa, Den}
We wanted to align the PMC and followed Koji's procedure detailed to us by mail. We touched the 2 steering mirrors in front of the PMC for alignment.
- Stand in front of the PMC.
- Find an oscillosocpe on the shelf in the PSL enclosure.
- This has two signals connected. One is the PMC refl dc.
The other is the PMC trans dc.
- Minimize the refl. Maximize the trans.
- You have the CRT monitor on the MC chamber.
- Project the image of the PMC refl CCD.
This should show some what symmetric image like an LG mode.
- Use the dataviewer to see how C1:PSL-PMC_PMCTRANSPD is recovered.
We were able to obtain 0.7 at PMC trans; but the PMC was never really stable dropped from 0.7 to 0 abruptly from time to time.
Jenne and Jamie also find that the PMC is behaving very weird 
Summary: Problem unresolved 
|
7478
|
Thu Oct 4 14:08:49 2012 |
jamie | Update | SUS | suspensions damped |
All suspension damping has been restored. |
7477
|
Thu Oct 4 14:04:21 2012 |
jamie | Update | CDS | front ends back up |
All the front end machines are back up after the outage. It looks like none of the front end machines came back up once power was restored, and they all needed to be powered manually. One of the things I want to do in the next CDS upgrade is put all the front end computers in one rack, so we can control their power remotely.
c1sus was the only one that had a little trouble. It's timing was for some reason not syncing with the frame builder. Unclear why, but after restarting the models a couple of times things came back.
There's still a little red, but it mostly has to do with the fact that c1oaf is busted and not running (it actually crashes the machine when I tried to start it, so this needs to be fixed!). |
7476
|
Thu Oct 4 08:39:58 2012 |
Steve | Update | General | power outage |
There had to be a power outage. Laser and air condition turned back on. The vacuum is OK
Sorensen DC power supplies were tripped, so they were reset: at AUX OMC South 18V and 28V for RF PS and at 1X1 24V
Power Outage confirmed:
** Notification **
CALIFORNIA INSTITUTE OF TECHNOLOGY
FACILITIES MANAGEMENT
**PLEASE POST**
Building: Campus
Date: Thursday October 04,2012
This morning at 2:17 a.m. much of the City of Pasadena including our Campus experienced a electric power sag of short duration, approximately 1/10 of a second. The cause was a fault on one of Pasadena’s 17KV circuits. Some sensitive equipment have been impacted.
Contact: Mike Anchondo x-4999
|
7475
|
Thu Oct 4 01:06:52 2012 |
Jenne | Update | IOO | PZT diagnosis |
[Koji, Jenne]
We naively hoped that just replacing the fuses would fix the problem with the PZT HV drivers. Alas, this was not the case.
All of our investigations (other than visual inspections) today have been of the PZT2 module. We have not applied any electricity to any PZT1 components/modules today.
After blowing a few more fuses (not good, we know, but we really didn't know what was going on at the time and were convinced that our changes between fuse installations should prevent fuse-blowing, including removing all modules except the HV driver), we found that the YAW driver for both PZT1 and PZT2 has severe discoloration on the PCB, and several resistors and other solder joints are damaged near some high voltage regulators. Pitch on PZT1 looks a tiny bit discolored, but doesn't look totally cooked like the 2 YAW modules do. So, at least PZT1's Yaw was cooked before we started replacing fuses, since we haven't plugged it in yet today.
We then began some more methodical checks:
We bypassed the fuses by applying 10 Vpp = ~7.2 Vrms to the input side of the big transformer on the PZT2 HV driver board. (This usually sees the 120 Vrms from the wall AC, so we were looking at things with a factor ~16 attenuation from what they normally see.) We then measured things on the other side of the transformer, and made sure that they made some sense (one path for 5V stuff, one path for 15V stuff, one path for 180V stuff). One of the rectifying diode bridges (the one for HV) didn't seem to be working, and didn't seem to have all of its pins connected, as if perhaps one or more diodes inside was destroyed.
When I went home for dinner, Koji continued looking at the low voltage supply capability of the PZT2 driver. He removed the diode bridge from the HV path, and also removed the FET that lives on the output side of the HV driver board. He was then able to energize the HV driver and the non-burnt pitch module. So the +\-5 V and +\-15 V paths have been confirmed okay for PZT2's driver stuff.
What I will do tomorrow (when there is someone here to rescue me if I crispy-fry myself) is solder a wire to the now open pin of the backplane connector on the HV driver board, so that we can supply an external 180V to the pitch / yaw modules (although, obviously we won't be using the burnt yaw modules as-is). Tomorrow I'll start by applying a nice small voltage, check that things still look okay, no shorts, and then I'll slowly increase the voltage until I get to the nominal 180V.
Since the low voltage stuff on the driver board is working, once we supply an external 180V (if successful), we should be able to re-install the PZT driver and drive PZT2.
Since both Yaw modules that we have are burnt, I am proposing that we use the PZT2 HV board (which has been checked and modified this evening) with the 2 pitch modules. Since we are not actively utilizing the strain gauge sensors, the fact that the calibrations on these modules are not exactly the same (rather, that PZT1's pitch is not the same as PZT2's yaw) should not matter at all. This means that we will not be able to energize PZT1 at all, but that shouldn't be a problem. Even when PZT 2 was working, PZT1 had very, very, very limited motion through the full range of applied voltage, so having no driver connected shouldn't have an impact.
|
7474
|
Wed Oct 3 23:36:54 2012 |
Koji | Configuration | PSL | AOM installation |
After the AOM work the beam wasn't well aligned to the PMC. The PMC REFL CCD shows large misalignment in yaw. |
7473
|
Wed Oct 3 23:24:05 2012 |
Koji | Update | SUS | MC2 sus damping restored |
Quote: |
This is the third morning in a row that the MC2 was tripped. Would you look at it Koji?
|
This may be cause by the impact of crazy WFS signal after the lock loss.
The auto locker is not fast enough to shut the WFS down before the mirrors are kicked.
Jenne and I discussed the issue and agreed that this can be solved by implementing
the same triggering algorithm as the LSC triggers.
Give us a bit more time to work on this. |
7472
|
Wed Oct 3 18:45:51 2012 |
jamie | Update | IOO | wiki page for active IO tip-tilts |
I made a wiki page for the active IO tip-tilts. I should have made this a long time ago. |
7471
|
Wed Oct 3 16:52:16 2012 |
Manasa | Configuration | PSL | AOM installation |
{Jan, Manasa}
We set start to check the performance of the AOM on the PSL table. The AOM driver spits out ~1.5W rf at 80MHz for 1V DC at its modulation input. In order to align the AOM, we reduced the input power to the AOM to ~10% using the QWP between the PBS and the laser. We touched the steering mirror before the AOM...but did not succeed in getting any appreciable first order deflection. We then released the AOM mount and moved it a few microns in and out until we obtained a significant change in power along the zero-order beam from 400mV to 100mV when the rf power was changed from 0 to ~1.5W (by changing modulation input from 0 to 1V). The AOM was clamped at this alignment and the QWP was rotated to give maximum input power.
During the course of aligning the AOM, the PMC unlocked and was restored after the alignment.
All went well without having to make any emergency calls to anyone
We will now have to think about switching the AOM on and off for ringdown measurements. This could be done by either using a high-power rf switch or by switching the modulation DC input between 0 and 1V; whichever will be more comfortable to take many many ringdown measurements.
|
7470
|
Wed Oct 3 16:26:58 2012 |
Manasa | Update | PEM | ants on the PSL table |
I spotted around 4 within 30 minutes working at the PSL table even after the deathly spray . They seem to be running down from the cables on the oscilloscope rack to the table and the optics. |
7469
|
Wed Oct 3 15:58:57 2012 |
Steve | Configuration | IOO | SOS coil drivers moved |
The SOS coil drivers (Atm2) were moved from 1X1 to 1Y2 location. Is this the best place to locate the IOO Tip-Tilt steering that will replace the PJ-PZT ?
See 40m wiki T-T |
7468
|
Wed Oct 3 15:37:04 2012 |
Steve | Update | PEM | ants on the PSL table |
We observed one or two ants climbing over PMC optics without booties and safety glasses.
The floor was mopped with strong Bayer Home Pest Control solution in the Vertex area.
Do not work inside the 40m lab if you are sensitive to chemicals!
|
7467
|
Wed Oct 3 11:43:33 2012 |
Steve | Update | SAFETY | safety training |
Den Martynov received 40m specific safety training. |
7466
|
Wed Oct 3 07:41:23 2012 |
Steve | Update | SUS | MC2 sus damping restored |
This is the third morning in a row that the MC2 was tripped. Would you look at it Koji? |
7465
|
Tue Oct 2 16:32:43 2012 |
Jenne | Update | IOO | PZT diagnosis |
[Koji, Jenne]
Jamie and I pulled the whole PZT driver for both PZT1 and PZT2.
Koji and I found that each HV power supply (the left-most module) has 2 fuses. Both HV supplies (PZT1 and PZT2) have one blown fuse. The "T2L250A" measures low resistance for both HV supplies, but the "T250mAL250V" measures Open for both HV supplies.
I have ordered 10 pieces of each kind of fuse, Next Day shipping, from DigiKey. |
7464
|
Tue Oct 2 16:15:22 2012 |
Manasa | Configuration | PSL | AOM installation |
Quote: |
{Jan, Manasa}
We installed the AOM driver back on the PSL table this morning. To calibrate the AOM RF output we connected a 1V dc to the modulation input of the driver and we are convinced with the setup.
Before we direct the rf signal to the AOM, in order to check its diffraction efficiency, we would like to setup an rf PD at the AOM output. We think we have place for a filter and PD after the AOM (replacing a beam dump) and would like to confirm the position before we actually install them. The layout is the picture below showing sweet spots for the new pd to sit. If you think it may disturb the system in any way, let us know!
|
The rf PD and filter have been installed at the earlier proposed spot on the PSL table.

|
7463
|
Tue Oct 2 15:14:54 2012 |
jenne, jamie | Update | IOO | PZT diagnosis |
pzt2 mod signals matched slider vals for both pitch and yaw
pzt2 yaw mon output = 6
pzt2 pitch mon output = 11.3
From the PZT connector-converter board we determined the following pin-outs:
X=Yaw: red=1, white=14, black=3
Y=Pitch: red=2, white=15, black=16
We believe that red is signal, white/black/shield are all ground. We also believe (although this is from the PMC PZT) that the expected capacitance of the PZTs should be in the 100's of nF range.
Here are the readings from the two PZT dsub connectors:
pin 1:14 PZT1 = ".003" on 2uF scale
PZT2 = ".184"
pin 2:15 PZT1 = ".002" on 2uF scale
PZT2 = ".202"
So we think this means (given this crappy capacitance meter) that PZT2 is showing roughly 200nF, which sounds ok, but that PZT1 is indeed bad.
So next we investigate the PZT2 driver.
|
7462
|
Tue Oct 2 14:20:33 2012 |
Manasa | Configuration | IOO | PDA255 not working |