40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 190 of 344  Not logged in ELOG logo
ID Date Author Type Categoryup Subject Text Attachments
  14882   Mon Sep 16 12:38:59 2019 aaronUpdateIOOWFS measurementsI wanted to make a zero model of this circuit
to get a handle on the results. I couldn't
import zero on pianosa, and I tried pip installing
  
  14886   Tue Sep 17 09:41:48 2019 gautamUpdateIOOWFS loop measurementsLet's
not worry about C1LSC until the c1iscaux
  
  14887   Tue Sep 17 10:34:48 2019 aaronUpdateIOOWFS loop measurementsI'm using the notebooks from rana as
a starting point, and making a script to
measure and fill the WFS sensing matrix.
  
  14888   Tue Sep 17 10:47:44 2019 rikaUpdateIOOWFS loop measurements[aaron, rika]

Once stop the auto-locker and realigned
to make beam to get into QPD again.
 MC2.pdf 
  14896   Wed Sep 18 14:45:52 2019 rikaUpdateIOOWFS loop measurements[aaron, rika]

Gettng TFs

In the data
we got yesterday, we can see some filter's
 Screenshot_from_2019-09-18_18-15-34.png 
  14897   Wed Sep 18 15:27:45 2019 gautamUpdateIOOTT cables need to be remadeSummary:

The custom ribbon cables piping
the coil driver board outputs to the eLIGO
 IMG_7945.JPG 
  14898   Thu Sep 19 09:39:30 2019 gautamUpdateIOOTT cables need to be remadeWhile debugging this problem, c1lsc models
crashed. I ran the reboot script this morning
to bring the models back. There was a 0x4000
 CDSoverview.png 
  14899   Thu Sep 19 11:26:18 2019 gautamUpdateIOOTT cables DON'T need to be remadeFalse
alarm - the mistake
was mine. Looking at the schematic
  
  14914   Mon Sep 30 13:20:55 2019 aaronUpdateIOOshot noise measurementI wanted to measure the RF transimpedance
of the WFS heads, as outlined above.

Summary: Measurement is not done.
  
  14929   Thu Oct 3 11:38:35 2019 aaronUpdateIOOWFS measurementsI set up the spectrum analyzer to make
the WFS head RF transfer function measurement
(V/W) on WFS1. I placed the Jenne laser on
  
  14946   Mon Oct 7 19:50:33 2019 gautamUpdateIOOIMC locking not working after this workSee trend. This is NOT symptomatic of some
frozen slow machine - if I disable the WFS
servo inputs, the lock holds just fine.
 IMCflaky.pngIMG_8015.JPG 
  14950   Tue Oct 8 10:29:19 2019 gautamUpdateIOOMC Transmission scanSummary:

There is ~ 7% variation
in the power seen by the MC2 trans QPD, depending
 MC2_transmission_scatter.pdftransmissionMaps.pdfcorrelStructure.pdf 
  14952   Tue Oct 8 16:54:56 2019 ranaUpdateIOOIMC locking not working after this workI think this offset setting thing is not
so good. People do this every few years,
but putting offsets in servos means that
  
  14957   Tue Oct 8 20:39:42 2019 aaronUpdateIOOWFS loop measurementsI installed nds2 on donatello with
yum, but still can't import nds2.
  
  14958   Wed Oct 9 09:37:28 2019 aaronUpdateIOOWFS loop measurementsI installed nds2 again, this time successfully
with
  
  Draft   Wed Nov 6 20:34:08 2019 KojiUpdateIOOEOM resonant box installed 




  
  15019   Wed Nov 6 20:34:28 2019 KojiUpdateIOOPower combiner loss (EOM resonant box installed)Gautam and I were talking about some modulation
and demodulation and wondered what is the
power combining situation for the triple
 power_combiner.pdf 
  15165   Tue Jan 28 16:01:17 2020 gautamUpdateIOOIMC WFS servos stable againWith all of the shaking (man-made and divine),
it was a hard to debug this problem. Summary
of fixes:
 QPD_recenter.png 
  15170   Tue Jan 28 20:51:37 2020 YehonathanUpdateIOOIMC WFS servos stable againI resume my IMC ringdown activities now
that the IMC is aligned again.

To avoid any accidental misalignments
  
  15175   Wed Jan 29 12:40:24 2020 YehonathanUpdateIOOIMC Ringdowns preliminary data analysisI analyze the IMC ringdown data from last
night. 

Attachment 1 shows the normalized
 IMCRingdownNormalizedRawdata.pdfIMCTransPDFits.pdf 
  15181   Fri Jan 31 16:04:30 2020 gautamUpdateIOOInput pointing driftOne factor which hampers locking efforts
is the apparent drift of the input beam into
the IFO. Over timescales of ~1 hour, I have
 IPdrift.pdfIPdrift_PRMI.pdf 
  15183   Mon Feb 3 13:54:10 2020 YehonathanUpdateIOOIMC Ringdowns extended data analysisI extended the ringdown data analysis to
the reflected beam following Isogai
et al.
 IMCTransReflAnalysis_anotated.pdf 
  15190   Wed Feb 5 21:13:17 2020 YehonathanUpdateIOOIMC Ringdowns extended data analysisI translate the results obtained in the
previous elog to the IMC 3 mirror cavity.
I assume the loss in each mirror in the IMC
  
  15215   Sat Feb 15 12:56:24 2020 YehonathanUpdateIOOIMC Transfer function measurement{Yehonathan, Meenakshi}

We measure the IMC transfer function
using SR785.
 IMCFrequencyResponse.pdfIMCRingdownNormalizedRawdata.pdfIMCREFLPDFits.pdf 
  15224   Tue Feb 25 19:58:06 2020 HangUpdateIOOMC2 coil balancing[Yehonathan, Hang]

We did some quick DC balancing
of the MC2 coil drivers to reduce the l2a
  
  15227   Wed Feb 26 22:05:06 2020 gautamUpdateIOOIMC checksToday, I did the following tests (and so
was touching electronics/cables at/around
1X2):
  
  15229   Wed Feb 26 23:50:51 2020 gautamUpdateIOOIMC checksIn the style of the KA characterization
of the CM board, the AO path gain EPICS slider
(IN2) of the IMC servo board was stepped
 sliderCal.pdfAO_inputTFs.pdf 
  15259   Fri Mar 6 01:19:19 2020 gautamUpdateIOOExcess laser frequency noiseSummary:

Sometime between 1PM and 6PM on
Tuesday, excess laser frequency noise
 MCF.pdfExcessFreqNoise.pdfALSnoise.pdf 
  15260   Fri Mar 6 16:33:11 2020 gautamUpdateIOOExcess laser frequency noiseI did some preliminary debugging of this,
and have localized the problem to the output
path (after MC slow) on the IMC Servo card.
  
  15265   Wed Mar 11 16:46:25 2020 HangUpdateIOOMC2 coil balancingMy old scheme was flawed as I used pitch
as the readback. The pitch signal could not
distinguish the cross-coupling due to coil
  
  15546   Sat Aug 29 18:52:42 2020 ranaUpdateIOOIMC gain changeI lowered
the (FAST) PZT gain on the IMC/FSS servo
today.
  
  15566   Wed Sep 9 20:52:45 2020 ranaSummaryIOOwandering line in IMCsince the summary pages are working again,
I was clicking through and noticed that there's
a wandering peak in the whitened IMC spectrogram
  
  15573   Tue Sep 15 17:19:09 2020 gautamUpdateIOOMC F spectrum There was an abrupt change in the MC_F
spectrum between August
4 and August
 MCF_MCL.pdf 
  15574   Tue Sep 15 19:17:30 2020 ranaUpdateIOOMC F spectrum that's a very curious disconnection

the "Pentek" whitening
board that carries the MC channels has jumpers
  
  15576   Wed Sep 16 09:43:41 2020 gautamUpdateIOOMC F spectrum This
elog suggests that there is uniformly
1 stage engaged across all channels. I didn't
 MCF_MCL.pdf 
  15641   Fri Oct 23 16:41:06 2020 KojiUpdateIOOExcess laser freq noise investigation[Koji, Rana]

We wanted to track down the excess
noise seen in MC_F and other places (see
 plot.pdf 
  15643   Mon Oct 26 13:35:58 2020 KojiUpdateIOOExcess laser freq noise investigationIn fact, the problem was the grounding
issue (presumably on the IOO racks).
A temporary differential receiver
 6x 
  15644   Mon Oct 26 17:26:26 2020 gautamUpdateIOOExcess laser freq noise investigationApart from the questionable wiring on the Acromags,
one other important difference is in the
way the connections were made between the
  
  15669   Tue Nov 10 12:41:23 2020 gautamUpdateIOO1W > IMCLooking back through the elog, 1mtorr is
the pressure at which it is deemed safe to
send the full power beam into the IMC. After
 CD93A725-FB5C-4F67-BB2E-D122205114B0.jpeg 
  15670   Tue Nov 10 14:30:06 2020 gautamUpdateIOOWFS2 broken While proceeding with the interferometer
recovery, I noticed that there appeared to
be no light on WFS2. I confirmed on the AP
 WFS2broken.pngWFS2broken_RF.png 
  15708   Fri Dec 4 15:58:22 2020 KojiUpdateIOOWFS2 broken I checked the backplane connection for
IMC WFS2  and found that the
cables for IMC WFS2 and the IMC demod were
  
  15713   Mon Dec 7 12:38:51 2020 gautamUpdateIOOIMC loop charSummary:

There seems to be significant phase
loss in the TTFSS path, which is limiting
 OLTFcomparison.pdfdemodMons.pdfOLTFcomparison.pdf 
  15965   Thu Mar 25 15:31:24 2021 gautamUpdateIOOWFS servosThe servos are almost certainly not optimal
- but we have the IFO sort of working, so
before we make any changes, let's make
  
  16006   Wed Apr 7 22:48:48 2021 gautamUpdateIOOWaveplate commissioningSummary:

I spent an hour today evening checking
out the remote waveplate operation. Basic
 remotePowCtrl.pdf 
  16022   Tue Apr 13 17:47:07 2021 gautamUpdateIOOWaveplate commissioning - software preparedI spent some time today setting up a workable
user interface to control the waveplate.


Created some EPICS database
 remoteHWP.png 
  16036   Thu Apr 15 15:54:46 2021 gautamUpdateIOOWaveplate commissioning - hardware installed[jordan,
gautam]
  
  16238   Tue Jul 6 10:47:07 2021 Paco, AnchalUpdateIOORestored MCMC was unlocked and struggling to recover
this morning due to misguided WFS offsets.
In order to recover from this kind of issue,
  
  16239   Tue Jul 6 16:35:04 2021 Anchal, Paco, GautamUpdateIOORestored MCWe found that megatron is unable to properly
run scripts/MC/WFS/mcwfsoff and scripts/MC/WFS/mcwfson
scripts. It fails cdsutils commands due to
  
  16705   Mon Mar 7 10:06:32 2022 YehonathanUpdateIOOIMC unlocked again, completely misalignedCame this morning and saw that the IMC
is unlocked.

Went into MC Lock screen and see
 Screenshot_2022-03-07_10-15-19.png 
  16708   Mon Mar 7 14:55:33 2022 KojiUpdateIOOIMC unlocked again, completely misalignedHmm, the bias values were reset at 2022-03-03-20:01UTC
which is 2022-03-03-12:01 PST with no apparent
disruption of the data acquisition (= no
  
ELOG V3.1.3-