  8021   Thu Feb 7 10:35:35 2013 yutaUpdateGeneralStore optics in respective cabinetsI'm not the one who opened the ITMX table
yesterday, but thanks for reminding me.
I put POP DC oscilloscope and its
  
  8020   Thu Feb 7 09:03:54 2013 ManasaUpdateGeneralStore optics in respective cabinets
@Yuta
The ITMX table has been left open since
  
  8019   Wed Feb 6 22:39:23 2013 JamieUpdateGeneralPRC/arm mode matching with flipped PR2/PR3: coming soonI intended to post a long analysis of the
PRC/arm mode matching for the various TT
situations using Nic's a
  
  8018   Wed Feb 6 20:19:52 2013 ManasaUpdateOpticsG&H and LaserOptik mirrors[Koji, Manasa]
We measured the wedge angle of the
G&H and LaserOptik mirrors at the OMC
  
  8017   Wed Feb 6 20:03:50 2013 ManasaUpdateLockingPRC cavity gains

    

       
            
  
  8016   Wed Feb 6 20:00:06 2013 ManasaUpdateElectronicsBNC cables piled up at every corner [Yuta, Steve, Manasa]
There are cables piled up around
the access connector area which have been
 109393779.png 
  8015   Wed Feb 6 19:59:35 2013 ranaUpdateLockingPRC cavity gains  Getting closer, but need to
use the real measured AR reflectivity values,
not the 1500 ppm guess. These should be measured
  
  8014   Wed Feb 6 18:39:08 2013 JenneUpdateLockingPRC cavity gains[Yuta, Jenne]
We have both calculated, and agree
on the numbers for, the PRC gain for carrier
  
  8013   Wed Feb 6 15:39:19 2013 SteveUpdateElectronicsDC power supplies in cabinets East arm cabinet E9 and E10
 
 IMG_0066_1.JPG 
  8012   Wed Feb 6 15:20:55 2013 yutaSummaryGeneralFWHM was wrongI have to blame Jamie for putting extra
2 randomly.
Measured PRM-PR2 cavity 
  
  8011   Wed Feb 6 15:11:21 2013 JenneUpdateElectronics"Temporary" power supply situation[Jenne, Yuta, Rana, Steve, Manasa]
We have taken stock of the lab
"temporary" power supply situation,
  
  8010   Wed Feb 6 15:10:22 2013 SteveUpdatePEMnew safety signs on exterier doors

    

       
            
 IMG_0068.JPG 
  8009   Wed Feb 6 15:05:18 2013 SteveUpdateSAFETYcameras must be anchordCameras
must be immediately anchord to avoid a possible
 IMG_0070_1.JPGIMG_0069_1.JPG 
  8008   Wed Feb 6 14:51:25 2013 JenneUpdateElectronics1 power supply replaced!

    

       
            
  
  8007   Wed Feb 6 11:59:12 2013 JenneUpdateLockingPRC cavity gainsEDIT:  These numbers are for a perfect,
non-lossy arm cavity.  So, a half real,
half imaginary world.
  
  8006   Tue Feb 5 19:32:47 2013 yutaSummaryGeneralPR2/PR3 flipping and PRC stabilityWe are considering of flipping PR2 and/or
PR3 to make PRMI stable because PR2/PR3 seems
to be convex.
 PRMI_PR2HR_PR3HR.pngPRMI_PR2AR_PR3HR.pngPRMI_PR2HR_PR3AR.pngPRMI_PR2AR_PR3AR.png 
  8005   Tue Feb 5 19:16:22 2013 JamieSummaryGeneralarbcav of PRC with +600 RoC PR2/3This is just a simple rerun of arbcav from
#7995
but with the PR2/3 RoCs set to 600, instead
 mode_density_PRC_3.pdfmode_density_PRC_2.pdf 
  8004   Tue Feb 5 15:31:03 2013 SteveUpdateGeneralclean assembly room benches cleaned upManasa, Jamie and Steve,
Tip-Tilts and parts moved into the
most north " 40m "  cabinet 
 IMG_0057.JPGIMG_0061.JPG 
  8003   Tue Feb 5 12:08:43 2013 Max HortonUpdateSummary PagesUpdating summary pagesGetting started:  Worked on
understanding the functionality of summary_page.py. 
The problem with the code is that it was
  
  8002   Tue Feb 5 11:30:19 2013 KojiSummaryGeneralrough analysis of aligned PRM-PR2 mode scanMakes sense. I mixed up n and n-1
Probability function: X = (x1 + x2
+ ... + xn)/n, where xi = xavg +/- dx
  
  8001   Tue Feb 5 10:18:54 2013 SteveUpdatePEMhigh particle count ALART

    

       
            
 badair.png100d_airq.png 
  8000   Tue Feb 5 10:09:08 2013 yutaSummaryGeneralrough analysis of aligned PRM-PR2 mode scanstdev of [0.764, 0.751] is 0.007, but what
we need is the error of the averaged number.
Statistical error of the averaged number
  
  7999   Tue Feb 5 09:08:11 2013 SteveUpdatePEM exterier doors to be painted

    

       
            
 IMG_0055.JPG 
  7998   Tue Feb 5 03:16:51 2013 KojiSummaryGeneralrough analysis of aligned PRM-PR2 mode scan0.764 and 0.751 do not give us the stdev
of 0.005.
I have never seen any Yokogawa in
  
  7997   Tue Feb 5 02:04:44 2013 yutaSummaryGeneralrough analysis of aligned PRM-PR2 mode scanI redid PRM-PR2 cavity scan using oscilloscope
to avoid anti-aliasing effect.
Measured 
 PRMPR2scan.png 
  7996   Mon Feb 4 22:46:03 2013 JamieSummaryGeneralarbcav for SRC with curved TTsI ran Zach's arbcav on our SRC with curved
TTs and the situation looks much worse than the PRC.
 mode_density_SRC_3.pdfmode_density_SRC_2.pdf 
  7995   Mon Feb 4 19:48:32 2013 JamieSummaryGeneralarbcav recalc of PRC with correct ITM transmissionI noticed that Koji used a high reflector
for the ITMs for his full PRC arbcav calculation.
 I just redo it here with the correct ITM
 mode_density_PRC_2.pdfmode_density_PRC_3.pdf 
  7994   Mon Feb 4 19:33:19 2013 yutaSummaryGeneralrough analysis of aligned PRM-PR2 mode scan[Jenne, Yuta]

We redid PRM-PR2 cavity scan because
 3peakdata.png 
  7993   Mon Feb 4 15:26:10 2013 JamieUpdateComputer Scripts / ProgramsNew "getdata" program to pull NDS channel data, including test pointsI've added a new program called getdata
(to scripts/general/getdata) that will conveniently
pull arbitrary data from an NDS server, either
  
  7992   Mon Feb 4 15:06:56 2013 KojiSummaryGeneralHypothesis

    

       
            
  
  7991   Mon Feb 4 11:10:59 2013 KojiSummaryGeneralrough analysis of aligned PRM-PR2 mode scanThe expected finesse is 100ish. How much
can we beleive the measured number of 50?
From the number we need to assume
  
  7990   Mon Feb 4 10:45:51 2013 JamieSummaryGeneralrough analysis of aligned PRM-PR2 mode scanHere's a sort of rough analysis of the
aligned PRM-PR2 cavity mode scan.
On Friday we took some mode scan
 scan-labeled.pdf 
  7989   Sun Feb 3 13:20:02 2013 KojiSummaryGeneralHypothesisRana mentioned the possibility that the
PR2 curvature makes the impact on the mode
stability. Entry
 mode_density_PRC.pdfmode_density_PRC.zip 
  7988   Fri Feb 1 23:52:59 2013 ranaUpdateLockingPRM/PR2 cavity Very exciting result, if true. I
suppose we should try to reconfirm this result
by doing another phase map of PRM03.
  
  7987   Fri Feb 1 23:12:42 2013 KojiUpdateLockingPRM/PR2 cavityDuring the scanning we were riddled by
the fact the PDH error and the transmission
peaks do not happen simultaneously.
  
  7986   Fri Feb 1 19:55:33 2013 JenneUpdateLockingPRM/PR2 cavity[Jamie, Koji, Jenne]
We are looking at the mode scan data,
and have some preliminary results! 
  
  7985   Fri Feb 1 15:12:53 2013 JenneUpdateLockingPRM/PR2 cavity After Jamie did all the work this
morning on the POP table, I was able to get
the cavity to lock.  It's not very stable
  
  7984   Fri Feb 1 14:47:17 2013 RijuUpdate Photodiode transimpedance Summary:  shotnoiseinterceptmcreflpd.pdf 
  7983   Fri Feb 1 12:34:55 2013 JenneUpdatePSLToo much power injected into vacuumI noticed (while relocking the MC after
Jamie and I zeroed the LSC offsets) that
the MC refl power was 4.8 V.  Usually
  
  7982   Fri Feb 1 12:22:27 2013 ZachSummaryASCOptics litIt's OK; even Siegman got it wrong---48
times.
RA: NO, stil not OK.
  
  7981   Fri Feb 1 09:33:11 2013 JamieUpdateLockingPRM/PR2 cavityI replaced the BS1 between the POPDC PD
and the camera with a 98 reflector, and moved
the 50 up before the BS to dump half the
  
  7980   Thu Jan 31 23:48:45 2013 KojiUpdateLockingPRM/PR2 cavityWow! What's happened?   
  7979   Thu Jan 31 22:14:11 2013 ranaSummaryASCOptics lit Gouy not Guoy:
http://www.rp-photonics.com/gouy_phase_shift.html
pronounced Goo-eee, with the emphasis
  
  7978   Thu Jan 31 20:06:22 2013 EvanUpdateLockingPRM/PR2 cavity[Jenne, Evan]
Tonight we made a non-folded cavity
between the PRM and PR2 as follows. I put
  
  7977   Thu Jan 31 15:56:38 2013 RijuUpdate Photodiode transimpedanceSummary: Measurement  shotnoiseinterceptpda10cf.pdf 
  7976   Thu Jan 31 15:34:22 2013 RijuUpdateRF SystemPhotodiode transimpedance

    

       
            
  
  7975   Thu Jan 31 15:20:46 2013 ZachUpdateLockingMode spacing calcI should mention that I just found a bug
in how it treats odd-mirror-number cavities.
For such cavities, HG modes with odd horizontal
  
  7974   Thu Jan 31 14:46:05 2013 JenneUpdateRF SystemPhotodiode transimpedance

    

       
            
  
  7973   Thu Jan 31 14:30:50 2013 JenneUpdateLockingMode spacing calcI have calculated (using Zach's sweet software)
the expected mode content for the various
possible PRCs that we can make. 
 Half_PRC_Configs.pdf 
  7972   Thu Jan 31 12:44:42 2013 RijuUpdate Photodiode transimpedanceToday I collected the data for shot noise
intercept current for MC REFL PD. I didn't
get many data points at higher DC voltage
  