  7758   Wed Nov 28 21:42:21 2012 ranaFrogsComputer Scripts / Programsdataviewer font errorAn error this evening on rossa: dataviewer
not working due to some font errors:
controls@rossa:~ 0$ dataviewer
  
  7757   Wed Nov 28 17:40:28 2012 jamieOmnistructureComputerselog working again on firefox 17Koji and I figured out what the problem
is.  Apparently firefox 17.0 (specifically
it's user-agent string) breaks fckeditor,
  
  7756   Tue Nov 27 19:06:16 2012 RijuUpdate Testing AG4395A+GPIB I ve tested another bandpass filter
today with similar set-up. This time I took
the data with corrected reference level.
 tfmag1.jpgtfphase1.jpg 
  7755   Tue Nov 27 17:45:42 2012 SteveUpdateGeneralspare optics of AP table moved to cabinetSpare optics from the AP table were moved
to glass cabinet in the east arm. I'm not
sure this is the right place. We'll see what
 IMG_1819.JPG 
  7754   Tue Nov 27 11:27:22 2012 SteveUpdatePEMparticle count is going up

Jeff is still working on the filter banks.
 5yparticles.pngparticle_6m_6m.png1y_particlec.png10y_particle_c.png 
  7753   Tue Nov 27 09:44:09 2012 SteveUpdateVACpumpdown at 15 days It took 15 days to reach 1e-5 Torr
The RGA was turned on yesterday.
The rga scan plotting was not working. Den
 pd74m15d.pngpd74m15d_rga1d.png 
  7752   Tue Nov 27 03:26:00 2012 JenneUpdateGeneralPOP beam on POP55, POP camera

    

       
            
  
  7751   Tue Nov 27 01:03:42 2012 AyakaUpdateWienerFilteringSound on PSL Last Thursday, I put the speaker
and my laptop in the PSL table, and make
triangular wave sound with the basic frequency
 gauss_psdcoh_mcf.pngtri40_psdcoh_mcf.pnggauss_filters_mcf.pngGauss_estimatefilters_mcf.png 
  7750   Tue Nov 27 00:45:20 2012 jamieUpdateIOOMC_L and laser frequency noise spectraI grabbed the a plot of the iLIGO PSL frequency
noise spectrum from the Rana manifesto:
 laser_noise.pdfMCL_noise.pdf 
  7749   Tue Nov 27 00:26:00 2012 jamieOmnistructureComputersUbuntu update seems to have broken html input to elog on firefox After some system updates this evening,
firefox can no longer handle the html input
encoding for the elog.  I'm not sure
  
  7748   Mon Nov 26 23:45:52 2012 AyakaUpdateIOOTuning MC_L[Rana, Jamie, Ayaka]
We could not lock the arms with MC_L
loop on. Therefore we measured the change
 POYerr_MCL.jpgMCL-MCFxover.jpgMCL-MCFxover2.jpg121126.tar.gz 
  7747   Mon Nov 26 19:27:59 2012 RijuHowTo Testing AG4395A+GPIBRiju, Jenne
We have checked the transfer function
of a bandpass filter using AG4395A network
 tfmag.jpgtfphase.jpg 
  7746   Mon Nov 26 18:56:34 2012 JenneHowToComputersData logging suggestionsWe've been talking for a while about how
we want to store data.  I'm not in love
with keeping it on the elog, although I think
  
  7745   Mon Nov 26 18:36:17 2012 JenneUpdatePEMBLRMS back

    

       
            
  
  7744   Mon Nov 26 10:58:20 2012 SteveUpdatePEMair cond maitenance tomorrowAir conditioning maintenance is scheduled
for tomorrow morning till noon.
  
  7743   Mon Nov 26 10:42:06 2012 AyakaUpdateLSCcalibration of armsI uploaded a zip file that contains data
files used for the calibration.
OLTF_x/y.txt: the open loop transfer
 armcalib.zip 
  7742   Mon Nov 26 10:06:51 2012 ranaSummaryIOOMC slides from 2002   MCtalk.pdf 
  7741   Sat Nov 24 23:50:35 2012 KojiUpdateIOOMC WFS refusing to workToday I found the IMC was misaligned significantly
by WFS feedback.
Once the feedback was cleared, it
  
  7740   Sat Nov 24 22:14:08 2012 KojiUpdateGeneralAP table cleaning upOn Wednesday (21st) night, I checked the
AP table as I wanted to try PRMI locking. 
It was difficult to work with the
 APTable121124.pdfAPTable121124.graffle.zip 
  7739   Sat Nov 24 13:58:07 2012 ranaUpdateLSCcalibration of armsFor the loop diagnosis, its best
to use the method of "IN1/IN2",
rather than manipulate the close loop gain.
  
  7738   Wed Nov 21 21:06:13 2012 AyakaUpdateLSCcalibration of armsMotivation
In order to estimate whether we can
see acoustic coupling in arms or not, we
 7x 
  7737   Wed Nov 21 01:36:36 2012 KojiUpdateIOOMCL disabled / WFS clear history restoredAs MCL is disturbing arm locking by injecting
a lot of noise, I have modified 'mcup' 
to disable MCL
  
  7736   Wed Nov 21 01:31:37 2012 Koji, AyakaUpdateLockingalignment on ETMX tableSince the transmission beam on ETMXT camera
seemed to be clipped, we checked the optics
on ETMX table.
 output.nv12.bmp 
  7735   Tue Nov 20 20:37:51 2012 KojiUpdateIOOMC autolockerLast night I found that the MC autolocker
has not been updated since the chamber was
closed.
  
  7734   Tue Nov 20 16:03:37 2012 janoschUpdatePEMSeismometers and a microphone
  
  7733   Tue Nov 20 15:24:52 2012 AyakaUpdatePEMSeismometers and a microphone I got two seismometers and one microphone
back from Tara.
They are now near the Gurlap under
  
  7732   Tue Nov 20 15:11:22 2012 SteveUpdateGeneralfew more sensing cardsNew  Lumitek IR
Sensor Cards are here. We got 2 pieces
of Q-11-T (2" x 2"), 2 pieces of
  
  7731   Tue Nov 20 11:40:19 2012 ranaConfigurationGreen LockingEnd table upgrade for auxiliary green laser : ETMX layout on new table 
 Mounts:

    No more mounts using the
  
  7730   Tue Nov 20 02:57:24 2012 Ayaka, Den, KojiUpdateLockingred in armsWe aligned and locked x and y arms.
MCL loop makes arms lock unstable,
adds a lot of noise at frequencies 60-100
 8x 
  7729   Mon Nov 19 23:14:31 2012 EvanUpdateCamerasETMYF focusAdjusted focus on ETMYF camera so that
the IR beam is in focus.
  
  7728   Mon Nov 19 22:42:14 2012 KojiConfiguration40m UpgradingEndtable upgrade for auxiliary green laser : ETMX layout on new table
    I don't like the idea to
place the cylindrical lenses right in front
of the laser. 
  
  7727   Mon Nov 19 20:17:53 2012 JenneConfiguration40m UpgradingEndtable upgrade for auxiliary green laser : ETMX layout on new table 
For convenience, I would include
a steering mirror in front of the TRX PD. 
  
  7726   Mon Nov 19 20:03:53 2012 ManasaConfiguration40m UpgradingEndtable upgrade for auxiliary green laser : ETMX layout on new tableI have attached the possible layout of
the optics on the new ETMX endtable. More
optics have been added when compared to the
 ETMX_endtable_New_Model.pdf 
  7725   Mon Nov 19 15:58:02 2012 SteveUpdateSAFETYsafety trainingCharles Blakemore  our new undergrad
help received 40m specific safety training
today.
  
  7724   Mon Nov 19 15:15:22 2012 JenneUpdateSUSAll oplev gains turned on

    

       
            
  
  7723   Mon Nov 19 15:12:52 2012 JenneUpdateAlignmentYarm locked IR

    

       
            
  
  7722   Sat Nov 17 22:50:17 2012 KojiUpdateAlignmentred in armsYou have constraints for the IR beams (i.e.
one PZT and one BS for 8 dofs), so now you
need to align the arms for the input IR beams.
  
  7721   Sat Nov 17 18:02:14 2012 DenUpdateAlignmentred in arms

    

       
            
  
  7720   Sat Nov 17 03:30:13 2012 Den, AyakaUpdateAlignmentred in armsWe aligned accurately 00 green in yarm,
changed voltage on PZT2 to see red flashing
at TRY at the normalized level 0.2-0.3. The
  
  7719   Fri Nov 16 09:57:57 2012 JenneUpdateGreen Lockingxarm locked

    

       
            
  
  7718   Fri Nov 16 03:12:39 2012 Ayaka, DenUpdateGreen Lockingxarm lockedWe aligned and locked xarm for green.
 etmxf.png 
  7717   Fri Nov 16 00:08:36 2012 KojiUpdateSUSMC2 woesPeople complained about the MC instability:
If
we aligned the MC, it locked nicely for a
  
  7716   Thu Nov 15 21:52:48 2012 Den, AyakaUpdateGreen Lockingyarm lockedWe aligned and locked Y arm for green:

    installed camera on PSL
to monitor green transmission
    aligned
 yarm.pngetmyf.png 
  7715   Thu Nov 15 03:09:08 2012 JenneUpdateAlignmentNo good progress, many optionsI didn't make any concrete progress today.
AS and REFL cameras are in place, and Manasa
has put ND 0.5 filters on both. I used a
  
  7714   Thu Nov 15 02:18:24 2012 DenUpdateModern ControlBS oplevI've applied LQR feedback technique to
BS oplev in pitch. I think the most inconvenient
thing in using LQR controller is the amount
 lqr_cost.pngolpit_hg.png 
  7713   Wed Nov 14 21:59:09 2012 DenUpdateCDSdaq errorsI tried to add a test point to C1MCS model
and spent next two hours rebooting front-ends,
restarting models and realigning MC.
  
  7712   Wed Nov 14 13:58:18 2012 JenneUpdateIOOTurn off MCL path before doing MC spot measurement

    

       
            
  
  7711   Wed Nov 14 09:01:42 2012 Dumb statement catcherUpdateIOOTurn off MCL path before doing MC spot measurement

    

       
            
  
  7710   Wed Nov 14 00:56:19 2012 JenneUpdateIOOWFS on, PZT2 ~set, AS camera backWFS
are back on, and working nicely. 
Den and I had seen a problem (which I had
  
  7709   Tue Nov 13 22:12:15 2012 JenneUpdateIOOTurn off MCL path before doing MC spot measurement[Jenne, Den]
We have discovered that the MCL loop
squishes the length fluctuations that result
  