Entry  Fri Jan 20 15:59:02 2012, kiwamu, Update, Green Locking, Y arm ALS noige budget Yarm_ALS_2012Jan19.png
    Reply  Fri Jan 20 16:24:50 2012, kiwamu, Update, Green Locking, Y arm ALS : time series time_series.png
    Reply  Fri Jan 20 17:05:59 2012, rana, Update, Green Locking, Y arm ALS : time series 
Entry  Tue Jan 24 18:11:13 2012, kiwamu, Update, Green Locking, Y arm ALS noise budget Yarm_ALS_2012Jan19.pngnewservo.png
    Reply  Wed Jan 25 02:59:46 2012, kiwamu, Update, Green Locking, Y arm ALS noise budget 
Entry  Wed Jan 25 17:32:03 2012, steve, Update, Green Locking, geen pointing into y arm is misaligned 
Entry  Thu Jan 26 06:09:52 2012, kiwamu, Update, Green Locking, noisy AS55 Yarm_ALS_2012Jan25.png
    Reply  Thu Jan 26 10:17:01 2012, steve, Update, Green Locking, geen pointing into y arm is realigned P1080513.JPG
    Reply  Fri Jan 27 05:21:43 2012, kiwamu, Update, Green Locking, fine alignment of the Y end green setup 
Entry  Fri Jan 27 16:55:28 2012, Jenne, Update, Green Locking, Y-green realigned 
Entry  Tue Feb 21 08:33:16 2012, steve, Update, Green Locking, periscope adapter plate percplate.PDF
Entry  Tue Feb 21 18:39:11 2012, kiwamu, Update, Green Locking, New BBPDs installed 
Entry  Mon Feb 27 14:35:37 2012, Jenne, Update, Green Locking, PSL Beat Setup BeatPSLlayout_27Feb2012.png
    Reply  Mon Feb 27 18:35:45 2012, Jenne, Update, Green Locking, X Beat Search 
Entry  Wed Feb 29 20:27:00 2012, Jenne, Update, Green Locking, X green beat - found it! 
Entry  Wed Mar 7 11:44:29 2012, Jenne, Update, Green Locking, Xgreen beatnote cable made, laid 
Entry  Fri Mar 9 16:00:46 2012, steve, Update, Green Locking, laser emergency shut down switch replaced at the south end 
Entry  Wed Mar 14 10:06:26 2012, steve, Update, Green Locking, dichroic mirror quotes 
    Reply  Thu Mar 22 08:14:21 2012, steve, Update, Green Locking, dichroic mirror quotes with large wedge 
Entry  Fri May 4 17:46:46 2012, Jenne, Update, Green Locking, PSL doubling oven back on 
Entry  Wed May 30 01:35:15 2012, yuta, Update, Green Locking, aligned Y arm green beam 
Entry  Thu May 31 01:27:16 2012, yuta, Update, Green Locking, PSL and Y arm green beams aligned 
Entry  Thu May 31 01:36:17 2012, yuta, Update, Green Locking, GREEN_TRX/GREEN_TRY PDs 
Entry  Thu May 31 16:19:07 2012, yuta, Update, Green Locking, temperature setting for PSL doubling crystal 
Entry  Thu May 31 16:54:12 2012, Jenne, Update, Green Locking, Links to old elogs for green beatnote laser temps 
Entry  Fri Jun 1 02:13:00 2012, Jenne, Update, Green Locking, Attempt at Ygreen beat - failed 
Entry  Sat Jun 2 03:19:37 2012, yuta, Update, Green Locking, Y green beat note found? - too small CIMG1437.JPG
Entry  Mon Jun 4 23:48:43 2012, jenne, Update, Green Locking, lowered gain 
Entry  Tue Jun 5 00:49:28 2012, Jenne, Update, Green Locking, Nightly update 
Entry  Tue Jun 5 22:03:22 2012, Jenne, Omnistructure, Green Locking, IR beat signal at PSL 
Entry  Wed Jun 6 02:28:02 2012, yuta, Update, Green Locking, tried to see Yarm length change with weak beat note beatycoarseringdown20120605.pngbeatysetup20120605.png
Entry  Wed Jun 6 21:11:45 2012, yuta, Update, Green Locking, improved Y arm green alignment beatygreenpower20120606.png
Entry  Thu Jun 7 01:46:05 2012, yuta, Summary, Green Locking, Y green beat - found it!! CIMG1504.JPG
    Reply  Thu Jun 7 02:25:27 2012, yuta, Update, Green Locking, improved Y arm green alignment - even more beatygreenpower20120607.png
    Reply  Thu Jun 7 02:59:31 2012, yuta, Update, Green Locking, Y green beat - found it!! 
Entry  Thu Jun 7 05:39:41 2012, yuta, Update, Green Locking, coarsely stabilized Y arm length with ALS MyFirstALS20120607.png
    Reply  Thu Jun 7 07:27:27 2012, Koji, Update, Green Locking, improved Y arm green alignment - even more freq_noise_AUX.pdf
Entry  Fri Jun 8 15:08:27 2012, yuta, Update, Green Locking, aligned/mode-matched Y green beat setup 
Entry  Mon Jun 11 21:50:08 2012, yuta, Update, Green Locking, beatbox looks OK CIMG1522.JPG
Entry  Tue Jun 12 01:58:33 2012, yuta, Update, Green Locking, aligned Y arm to Y end green 
Entry  Tue Jun 12 11:54:50 2012, Jenne, Update, Green Locking, c1gcv recompiled c1gcv20120612.png
    Reply  Tue Jun 12 20:35:46 2012, yuta, Update, Green Locking, c1gcv recompiled c1gcv20120612-2.png
Entry  Tue Jun 12 23:18:18 2012, yuta, Update, Green Locking, I-Q signals for the beat FINEIQplot20120612.pngCOARSEIQplot20120612.pngbeatysetup20120612.png
Entry  Wed Jun 13 02:11:59 2012, yuta, Update, Green Locking, my first modescan (sort of) modescan20120612_1.png
    Reply  Wed Jun 13 02:24:02 2012, rana, Update, Green Locking, my first modescan (sort of) 
    Reply  Wed Jun 13 03:03:38 2012, yuta, Update, Green Locking, my first modescan (sort of) 
    Reply  Wed Jun 13 11:10:56 2012, rana, Update, Green Locking, my first modescan (sort of) 
Entry  Wed Jun 13 17:39:13 2012, yuta, Update, Green Locking, calibrating the beatbox ALS-BEATY_COARSE_I_IN1_DQ.pngALS-BEATY_COARSE_Q_IN1_DQ.pngALS-BEATY_FINE_I_IN1_DQ.pngALS-BEATY_FINE_Q_IN1_DQ.png
Entry  Thu Jun 14 01:36:34 2012, yuta, Update, Green Locking, can't scan Y arm for 1FSR BEATY_COARSE_LoopOnOff.png
Entry  Thu Jun 14 04:53:39 2012, yuta, Summary, Green Locking, designing ALS loop for mode scan ALSloop.pngALSopenloop.pngyarmlength.png