7809
|
Tue Dec 11 10:09:04 2012 |
Ayaka | HowTo | PEM | cables needs care |
Quote: |
How NOT to:
The janitor can not clean in areas like this. He may only steps on these cables accidentally as he dust wiping our chambers.
|
Sorry for the mess. I fixed it. |
7808
|
Tue Dec 11 09:31:47 2012 |
Ayaka | Update | LSC | Oplev update for improving sensitivity |
Motivation
We observed that oplev servos affect the arm spectra badly (elog #7798). Some of them are fixed, but still they inject noise into the arms.
So I tried to turn the oplevs off and to see the acoustic noise effect. However, the mirrors moves so much that the signal does not seem to be linear any more, and the noise spectrum of arms changes especially around 60 - 100 Hz as you can see the spectrogram of YARM error signal below. This makes it difficult to find acoustic coupling noise. Therefore, I tried to fix the oplev servos so that the noise spectra do not get worse when the oplev servos are on.

Checking oplev UGFs
I checked the oplev open loop transfer functions. The UGFs of oplevs are all around 1-3Hz and phase margin looks enough except the BS oplev.
The gain of the BS oplev OLTF has so low that the signal is not fed back. Moreover, there is much phase delay in the BS feedback loop than the others'.
The counts of BS oplev sum is not changed so much for this 4 months, so the oplev beam seems to hit the BS correctly.
I am not sure what makes difference.
 

Clipped oplev beam fixed
Den and I found the output beam of ETMY oplev was clipped the other day. Also I found the scattered beam of ITMY oplev was on the edge of the mirror inside the vacuum and it made more scattered lights.
(before) -> (after)
I fixed both of the clipped beam. But still the oplev feedback inject the noise into the arm. (red: oplev off, blue: oplev on)
 |
7807
|
Tue Dec 11 08:53:52 2012 |
Steve | HowTo | PEM | cables needs care |
How NOT to:
The janitor can not clean in areas like this. He may only steps on these cables accidentally as he dust wiping our chambers. |
7806
|
Mon Dec 10 22:34:34 2012 |
Den | Update | LSC | beam inside DRMI is clipping on PR3 Tip-Tilt |
Quote: |
That's OK, but its best to use standard notation. The power recycling gain is defined as the power incident on the BS divided by the power incident on the PRM from the laser side. You should also compare it with the PRC gain that you expect from mirror transmissions.
|
I've made snapshots of PR2, PRM, ITMY and ITMX mirrors. Power buildup recycling gain (POWER BS / POWER PRM) was equal to 3-4.

|
7805
|
Mon Dec 10 16:28:13 2012 |
jamie | Omnistructure | Computers | progressive retrieval of online data now possible with the new NDS2 client |
Leo fixed an issue with the new nds2-client packages that was preventing it from retrieving online data. It's working now from matlab, python, and octave.
Here's an example of a dataviewer-like script in python:
#!/usr/bin/python
import sys
import nds2
from pylab import *
# channels are command line arguments
channels = sys.argv[1:]
conn = nds2.connection('fb', 8088)
fig = figure()
fig.show()
for bufs in conn.iterate(channels):
fig.clf()
for buf in bufs:
plot(buf.data)
draw()
|
|
7804
|
Mon Dec 10 10:13:41 2012 |
Den | Update | LSC | beam inside DRMI is clipping on PR3 Tip-Tilt |
That's OK, but its best to use standard notation. The power recycling gain is defined as the power incident on the BS divided by the power incident on the PRM from the laser side. You should also compare it with the PRC gain that you expect from mirror transmissions. |
7803
|
Mon Dec 10 03:02:03 2012 |
Den | Update | LSC | beam inside DRMI is clipping on PR3 Tip-Tilt |
Quote: |
Some explanation of how you define power buildup please. Also some plots showing the evidence.
|
I think about power buildup as a ratio of the power in the cavity when it is locked and unlocked = (POYDC_LOCKED - POYDC_OFFSET) / (POYDC_UNLOCKED - POYDC_OFFSET). I do not multiply this number by PRM transmission.
POYDC_OFFSET = -0.006
POYDC_UNLOCK = 0.063
For example, on the plot below power buildup is 15.

|
7802
|
Sun Dec 9 17:51:53 2012 |
rana | Update | LSC | beam inside DRMI is clipping on PR3 Tip-Tilt |
Some explanation of how you define power buildup please. Also some plots showing the evidence. |
7801
|
Sun Dec 9 01:21:51 2012 |
Den | Update | LSC | beam inside DRMI is clipping on PR3 Tip-Tilt |
Quote: |
Today I wanted to check that AS and REFL beams are real and contain proper information about interferometer. For this I locked YARM using AS55_I and REFL11_I. Then I compared spectrum with POY11_I locking. Everything is the same. I've also adjusted phase rotations of AS55 (0.2 ->24) and REFL11 (-34.150 -> -43).
|
I studied more carefully beam path inside DRMI using PRM face camera and found that beam is clipping on PR3 edge.
Step 1: PRCL LOCK, MICH LOCK, power build up 30.
Note: left is right and vice versa on the PRM camera

Step 2: PRLC - UNLOCK, MICH - LOCK, PRM is still aligned. Right photo is AS port. I've slightly misaligned ITMs such that disturbance of AS beam is clearly seen.

Step 3: PRCL - UNLOCK, MICH - LOCK, PRM misalined in yaw such such that the beam LASER -> PRM -> PR2 -> PR3 -> BS -> ITMX -> BS -> PR3 -> PR2 -> PRM -> PR2 -> PR3 is completely clipped on the TT edge. AS beam is now not clipped.

So the conclusion is that when PRC is not locked and beam is thin, it can avoid clipping. When PRC locked, beam size grows and it starts to clip. I think we need to move the mount next to PR3 because of it we to not have enough space to align the TT.
Step 4: PSL shutter is closed.

|
7800
|
Sat Dec 8 04:12:38 2012 |
Den | Update | LSC | prcl |
Today I wanted to check that AS and REFL beams are real and contain proper information about interferometer. For this I locked YARM using AS55_I and REFL11_I. Then I compared spectrum with POY11_I locking. Everything is the same. I've also adjusted phase rotations of AS55 (0.2 ->24) and REFL11 (-34.150 -> -43).
Then I've locked MICH and aligned EMTs such that ASDC was close to zero. Then I locked PRCL and aligned PRM. Power buildup was 50.

|
7799
|
Fri Dec 7 20:34:31 2012 |
Ayaka | Update | SUS | oplevs as acoustic and seismic noise couplers at high frequencies |
I will just leave the picture of spectrum that shows the injected acoustic sound effects due to the oplevs.

red line: POY error without oplev feedback nor acoustic noise
blue line: POY error without oplev feedback but with acoustic noise
brown line: POY error with oplev feedback but without acoustic noise
green line: POY error with oplev and acoustic noise
You can see there is noise only at green line around 70 - 100 Hz. And it does not look like the acoustic signal is injected directly to the arms but the acoustic sound couples to the original noise source. |
7798
|
Fri Dec 7 19:24:43 2012 |
Den, Ayaka | Update | SUS | oplevs as acoustic and seismic noise couplers at high frequencies |
We've provided acoustic excitation using speakers on the AS table and saw that PSD of YARM feedback signal increased in the frequency range 50 - 100 Hz. Meanwhile, XARM feedback signal did not change. Moreover, YARM noise is much higher at these frequencies compared to XARM.
The problem was with YARM oplev servos. Both ITMY and ETMY produced noise to YARM length. ITMY oplev signal had a huge resonance at 55 Hz. We measured coherence with accelerometers, it was 0.8. It turned out that one of the mirror mounts was not fixed in the oplev path. When we fixed it, noise has gone.
Note: speakers were on AS table but mirror mounts could steel feel it on ITMY table.

Then we had a look on ETMY table. We saw a mirror on suspiciously long mirror mount that was used in the ETMY oplev path. We slightly kicked long mount with a small screwdriver and YARM control signal went up with resonance at 100 Hz.

|
7797
|
Fri Dec 7 02:02:23 2012 |
Den | Update | Alignment | c1ass |
I suppose that there is also a similar system possible to align the arms in a continuous way; i.e. low level drives and very low bandwidth. Also something fast / slow for the the DRMI.
|
c1ass was really useful today when we slowly aligned PZT and servo kept arms aligned to the input beam. I think it is possible to automate phase and matrix measurements. DRMI servo will be very useful.
Today I tried to investigate the mode in PRCL and MICH. I locked them but power build-up was only 27. The beam on the POP camera looked like interference of 00 mode and a long strip of fringes. (I wanted to make videocaptures but script is not working - the problem is that it is looking for /usr/lib/*.so.4 libraries but they were updated to *.so.5, I made a few links .so.4 -> .so.5 but this kept going for many libraries, so this should be fixed in a better way).
We looked at PRM and BS faces and they had the same shape - interference of a circle with a strip. There were also a lot of bright spots all over the frames. Loops were closed and circle was not moving. Strip was oscillating at ~1Hz and also its position significantly changed with alignment. Looking at PRM face camera we made a conclusion that the length of the strip is ~5 cm and width ~1cm. Interesting that strip has plenty of power - approximately 10 times of transmitted beam when cavity is not locked. As a result POYDC was oscillating at the same frequency as a strip. |
7796
|
Fri Dec 7 00:08:39 2012 |
rana | Update | Alignment | c1ass |
This looks like a good performance tuning for these. It would be good if you can codify this procedure in the wiki so that even unexperienced people can tune up the system after reboots or vacuum work.
Is it possible to have some python scripts automatically measure and set the phases and matrices? If so, can we also run them iteratively so that after the second run we can confirm that they have converged? Then the script can output a short report of numbers telling us how well the system is now tuned.
I suppose that there is also a similar system possible to align the arms in a continuous way; i.e. low level drives and very low bandwidth. Also something fast / slow for the the DRMI. |
7795
|
Thu Dec 6 02:55:46 2012 |
Den | Update | Alignment | c1ass |
Today I've set c1ass model to improve alignment of X and Y arms. I've added all measured parameters to ASS scripts. I've also added a script to c1ass.adl that downloads calculated OFFSETs to corresponding ASC filter banks and blocks outputs. It should be called after alignment convergence.
XARM phase rotation and sensing matrix
Demodulator |
Phase rotation, degrees |
ETM_P_T |
-5 |
ETM_Y_T |
-10 |
ITM_P_T |
-62 |
ITM_Y_T |
163 |
I-quadrature |
ETM_PIT |
ETM_YAW |
ITM_PIT |
ITM_YAW |
ETM_P_T |
1.0000
|
-0.6116 |
-0.560 |
0.5660 |
ETM_Y_T |
-0.1600 |
1.0000 |
0.2310 |
-0.3979 |
ITM_P_T |
-0.0794 |
0.4960 |
1.0000 |
-0.8791 |
ITM_Y_T |
0.0624 |
-0.3903 |
-0.4787 |
1.0000 |
Output gains were (-0.5, 0.5, -0.25, -0.25). XARM Gain was set to 0.5.

YARM phase rotation and sensing matrix
Demodulator |
Phase rotation, degrees |
ETM_P_T |
10 |
ETM_Y_T |
0 |
ITM_P_T |
107 |
ITM_Y_T |
-35 |
I-quadrature |
ETM_PIT |
ETM_YAW |
ITM_PIT |
ITM_YAW |
ETM_P_T |
1.0000
|
0.3899 |
-0.515 |
-0.0309 |
ETM_Y_T |
0.1017 |
1.0000 |
-0.3143 |
-0.5269 |
ITM_P_T |
-0.3505 |
0.0565 |
1.0000 |
-0.0945 |
ITM_Y_T |
-0.2085 |
-0.3607 |
0.6042 |
1.0000 |
Output gains were (-0.25, 0.25, 0.7, -0.7). YARM Gain was set to 0.8.

|
7794
|
Wed Dec 5 17:38:41 2012 |
Riju | HowTo | | Photodiode transimpedance |
I have started making the circuit to measure the transimpedance for the photodiode PDA10CF using Jenne's laser. I will continue it tomorrow. |
7793
|
Wed Dec 5 16:54:29 2012 |
jamie | Omnistructure | Computers | new (beta) version of NDS2 installed on control room machines |
Quote: |
NDS2 is not designed for non DQ channels - it gets data from the frames, not through NDS1.
For getting the non-DQ stuff, I would just continue using our NDS1 compatible NDS mex files (this is what is used in mDV).
|
The NDS2 protocol is not for non-DQ, but the NDS2 client is capable of talking both the NDS1 and NDS2 protocols.
fb:8088 is an NDS1 server, so the client is talking NDS1 to fb. It should therefore be capable of getting online data.
It doesn't seem to be seeing the online channels, though, so I'll work with Leo to figure out what's going on there.
The old mex functions, which like I said are now available, aren't capable of getting online data. |
7792
|
Wed Dec 5 09:53:01 2012 |
rana | Update | WienerFiltering | The microphones and the speaker on the AP table |
Don't try to re-invent the mic mount: just copy the LIGO mic mount for the first version. |
7791
|
Wed Dec 5 09:42:46 2012 |
rana | Omnistructure | Computers | new (beta) version of NDS2 installed on control room machines |
NDS2 is not designed for non DQ channels - it gets data from the frames, not through NDS1.
For getting the non-DQ stuff, I would just continue using our NDS1 compatible NDS mex files (this is what is used in mDV). |
7790
|
Wed Dec 5 03:25:32 2012 |
Den | Update | ASC | dithering |
I wanted to center beams on the XARM cavity mirrors using c1ass model. I've run XARM setup script and then turned dithering on. Cavity went out of lock because calculated offsets were incorrect.
I was using TRX only and calculated rotation phases for ITM and ETM pitch and yaw. For this I've added a low pass filter into Q-quadrature bank and made DC value at the output to be zero by adjusting the phase. I've put gains (+1 or -1) in the I quadrature such that output was positive.
Then I've set the sensing matrix to identity as I decided to deal with separate loops. Of coarse, they are mixed by the cavity, but at least in the control system they are distinguished. Old matrix summed error signals in one degree of freedom from both mirrors. This makes more sense but still not precise because coils are not ideally diagonalized.
Then I've adjusted gains for control loop for every degree of freedom. I've ended up with (0.1; 0.1; 0.1; -0.1). I did not use large gains as I wanted slow convergence because of the demodulation low-pass filter time response constant of 20 sec. Coupling (I quadrature) was reduced from (0.9, 0.3, 2.4, 1.2) to zeros (0-0.1) in ~5 minutes, TRX increased from 0.73 to 0.90.
There is one thing that I do not understand yet. I think controllers should minimize angle -> length coupling that is proportional to I-quadrature if phase is correct. But phase depends on alignment and when the feedback loops are on, phase drifts. I could see it during my measurement. But I did not find any script that smoothly tunes phase such that coupling is all in I-quadrature. I guess this is not hard to set a gradient descent algorithm that minimizes DC value of Q-quadrature. Or how this is usually done? |
7789
|
Wed Dec 5 01:06:22 2012 |
Ayaka | Update | WienerFiltering | The microphones and the speaker on the AP table |
In order to see the acoustic coupling on arm signals, I set 6 microphones and the speaker on the AP table. The microphones are not seismically isolated for now.
I have a signal generator under the AP table.
 
When I played the 43 Hz triangular wave sound, I could see some coherence between POY error signal and microphones even though there is no peak in POY.

To Do:
- Try to subtract the acoustic signal and see with which microphone the acoustic signal can be subtracted best. But how can I find whether the signal is subtracted or not? Is coherence information enough?
- Make circuits for microphones to come to 40m.
- Make suspension systems for microphones. One idea is that the microphones should be suspended from bridges which is to be put around at the top of the tables since there is no space for stacks for each microphones.
- Prepare a new ADC.
- Perform the same measurements at the other tables, such as POX and POY.
|
7788
|
Tue Dec 4 23:08:46 2012 |
Den | Omnistructure | Computers | new (beta) version of nds2 installed on control room machines |
Quote: |
I've installed the new nds2 packages on the control room machines.
|
I've tried new nds2 Java interface in Matlab. Using findChannels method of the connection class I see only slow, DQ and trend channels. I could even download data online using iterate method. When it will be possible to do the same with fast non-DQ channels?
>> conn = nds2.connection('fb', 8088);
>> conn.iterate({'C1:LSC-XARM_OUT'})
??? Java exception occurred:
java.lang.RuntimeException: No such channel.
at nds2.nds2JNI.connection_iterate__SWIG_0(Native Method)
at nds2.connection.iterate(connection.java:91)
|
7787
|
Tue Dec 4 21:57:04 2012 |
Den | Update | SUS | TTs are ready |
Quote: |
Please leave here what was the instruction by Bran and Suresh so that the other people can redo it sometime later!
|
The connectors can be plugged into the BOSEMs if we loosen the two screws which hold down the mini-D connector and the flex circuit. Tighten the screws after the connector is pluged in. |
7786
|
Tue Dec 4 20:38:51 2012 |
jamie | Omnistructure | Computers | new (beta) version of nds2 installed on control room machines |
I've installed the new nds2 packages on the control room machines.
These new packages include some new and improved interfaces for python, matlab, and octave that were not previously available. See the documentation in:
/usr/share/doc/nds2-client-doc/html/index.html
for details on how to use them. They all work something like:
conn = nds2.connection('fb', 8088)
chans = conn.findChannels()
buffers = conn.fetch(t1, t2, {c1,...})
data = buffers(1).getData()
NOTE: the new interface for python is distinct from the one provided by pynds. The old pynds interface should continue to work, though.
To use the new matlab interface, you have to first issue the following command:
javaaddpath('/usr/lib/java')
I'll try to figure out a way to have that included automatically.
The old Matlab mex functions (NDS*_GetData, NDS*_GetChannel, etc.) are now provided by a new and improved package. Those should now work "out of the box". |
7785
|
Tue Dec 4 20:13:55 2012 |
Koji | Update | SUS | TTs are ready |
Please leave here what was the instruction by Bran and Suresh so that the other people can redo it sometime later!
|
7784
|
Tue Dec 4 18:53:50 2012 |
Ayaka | Update | Alignment | BS chamber |
BS chamber seemed to be kicked again around 10:00 am today.
I moved PZT mainly in YAW and locked both arms. I adjusted the beam to be almost on the center of both ETM by sights.

|
7783
|
Tue Dec 4 18:06:35 2012 |
Den | Update | SUS | TTs are ready |
Using instructions from Bram and Suresh, I was able to plug in connectors to BOSEMs. Today I've tested electronics, everything works good. Jamie made an medm screen and channels for TTs. Sliders for pitch and yaw go from -100 to 100 counts. Calibration to angle is 1e-5 rad / count.
TTs are in the clean room waiting for installation.

|
7782
|
Tue Dec 4 11:30:36 2012 |
Zach | Update | PSL | PMC calibration for MC_F calibration |
In order to have less unknown, you can calibrate the PMC PZT separately. Lock the PMC and take a transfer function from either the NPRO PZT input or the FSS AOM VCO input to the PMC control signal. The VCO is better, since the calibration should be much better known, but I am not sure what the current setup of the 40m PSL is, so I don't know if the FSS is normally locked.
Since you know the NPRO PZT or VCO actuation coefficients, you can assume the PMC loop (where the OL gain is high enough) is correcting for the frequency fluctuations. So, simply multiply the known coefficient by the transfer function to get the PMC PZT gain.
Then, you can re-do your PMC PZT sweep measurement and be confident of the calibration. The FSR must be right, so you can get the finesse with confidence.
Quote: |
Hmm... Does anyone find falses in my measurement?
If not, the finesse can be 4 times smaller than the value which was 5 years ago?
|
|
7781
|
Tue Dec 4 10:51:10 2012 |
Steve | Update | SUS | PRM damping restored |
PRM oplev gains set to zero from PIT 0.15 and YAW -0.3 and damping restored |
7780
|
Tue Dec 4 10:44:36 2012 |
Steve | Update | PEM | short power outage |
CALIFORNIA INSTITUTE OF TECHNOLOGY
FACILITIES MANAGEMENT
**PLEASE POST**
Building: Campus
Date: Thursday October 04,2012
This morning at 2:17 a.m. much of the City of Pasadena including our Campus experienced a electric power sag of short duration, approximately 1/10 of a second. The cause was a fault on one of Pasadena’s 17KV circuits. Some sensitive equipment have been impacted.
Contact: Mike Anchondo x-4999 |
7779
|
Tue Dec 4 01:43:37 2012 |
rana | Update | PSL | PMC calibration for MC_F calibration |
If you can't find the PMC sidebands in the transmission, its because the SNR is too small.
It may be a better idea to look at the PMC error signal, since the DC signal there is suppressed by the demodulation. |
7778
|
Mon Dec 3 17:04:12 2012 |
Ayaka | Update | PSL | PMC calibration for MC_F calibration |
In order to calibrate MC_F signal, I need to know the calibration value from thorlab's PZT driver to laser frequency.
The calibration value should be ~ 15MHz/V (the PZT driver has 15 gain, and the laser has the calibration value of ~ 1MHz/V according to the laser spec sheet), but I want to confirm it.
This can be measured by sweeping the input voltage of the PZT driver and see the transmission signal from unlocked PMC.
1. Response of PMC transmission when the signal is inputted to laser PZT
I inputted 0.2 Hz triangular wave with 5Vamp and 2.5V offset into the PZT driver and see the transmission signal from PMC. After the PZT driver and before the laser, there is an analog low pass filter but its cut off frequency is 1 Hz so I did not take it into consideration.
 (TEK00000.CSV, TEK00001.CSV in the zip file)
I could not the side-band resonances. I guess it was because the generated signal is not big enough (but still the maximum range of the signal generator.)
Therefore, in order to calibrate the input voltage to the frequency, I need to know finesse or FWHM frequency.
2. Responce of PMC transmission when the voltage of PZT on the PMC is swept
In order to measure the finesse and FWHM frequency, I also swept the PMC PZT voltage with the DC offset slider at the FSS.adl and tried to measure the finesse of PMC. (reference: elog #904)
 (PMC-PZTcal_121203.xml in the zip file)
The result of fitting:
V_FSR (the PZT voltage difference between the 2 resonances) ~ 63 +/- 7 V (= 731MHz (given))
V_FWHM (the PZT voltage to sweep FWHM) ~ 0.32 +/- 0.04 V (~ 3.7 MHz)
Finesse ~ 200 +/- 30
However, this finesse value is much smaller than the value on the Wiki, 800. (Manasa showed me.)
V_FSR is comparable to the result Rana got at the referenced elog. But I am not sure about the V_FWHM because it is hard to figure out how large the PZT voltage changed from the template file (PMC-PZTcal.xml).
Are those mode wrong? But if so, where is the correct mode resonances? I think they should be visible...
3. Calibration value
When I know the FWHM frequency, I can calibrate the input on the PZT driver into laser frequency.
The results are:
if I take the finesse of 800 and FSR of 731 MHz (the values on the Wiki): ~5.0 MHz/V
if I take the finesse of 200 and FSR of 731 MHz (the measured value): ~20.0 MHz/V
Actually, the measured value is closer to the value calculated from the spec sheet.
Hmm... Does anyone find falses in my measurement?
If not, the finesse can be 4 times smaller than the value which was 5 years ago? |
7777
|
Mon Dec 3 16:37:09 2012 |
Steve | Update | PEM | EM 172 microphones ordered |
Quote: |
I've put EM 172 microphones inside Steve's isolation box to measure their noise. I've attached mics to each other and aligned them using the tape.
At low frequencies (below 1 Hz) the noise is limited by ADC as there is a 10 Hz high-pass filter inside mic readout box.
ADC noise is measured by splitting the signal from 1 mic into 2 ADC channels.

|
BT EM172 microphones are ordered. |
7776
|
Mon Dec 3 07:40:00 2012 |
Steve | HowTo | Alignment | how was the BS chamber misalinged |
Quote: |
Whoever was working around the BS chamber at 11 AM on Friday should admit it now and take the punishment.
For those of you who like to do work on the interferometer without reporting it in the elog because you think that what you did doesn't affect anything, this is your example of how our time can be wasted by such laziness.
|
I'm taking full responsibility for this action and I told them after lunch Friday.
HOW NOT TO:
The BS isolation stack supported by two beam tubes and they can pivot around the pivot point. |
7775
|
Sun Dec 2 00:37:49 2012 |
Den | Update | SUS | TT cable problem |
This week I've got all TT stuff baked and today was testing eddy current damping and electronics.
In the beginning everything was good: ring magnets fit mirror holder holes and their interaction with actuation magnets is strong enough to keep damping magnets in the wholes. I've put the frame horizontally and kicked it, magnets were still in the whole. Brackets also fit to the TT frame.

I've tested eddy current dumping during ring down measurements, it was strong enough.

Then I started to test electronics. I've provided signal to TT1 channels and could see it in the clean room. But then things went terrible. I just could not connect TT cables to OSEMS, there is not enough space in the OSEM for the connector to plug in.

Connector should be machines to be more narrow. There is actually no reason for a connector to have this shape. I think it was designed to fit perfectly the OSEM frame but turned out to be ~0.5 mm wider then it should be. |
7774
|
Sat Dec 1 16:58:14 2012 |
Manasa | Update | WIKI-40M Update | Optical tables |
I have updated the wiki with the layout of the out-of-vac optical tables: Updated optical tables
I used the new camera to take pictures.
Lesson learnt after the update:
To use the new canon to take better pictures of optics tables; set the camera to manual mode; no flash and iso at around 800 or higher if you can hold the camera still for that long. The autofocus works beautifully...so you will not need any minor tweaking of lens to take pictures. |
7773
|
Sat Dec 1 13:56:38 2012 |
rana | Update | Alignment | BS chamber |
Whoever was working around the BS chamber at 11 AM on Friday should admit it now and take the punishment.
For those of you who like to do work on the interferometer without reporting it in the elog because you think that what you did doesn't affect anything, this is your example of how our time can be wasted by such laziness. |
7772
|
Sat Dec 1 00:24:37 2012 |
Den, Ayaka | Update | Alignment | BS chamber |
Today at 11:13 AM the stack of invacuum BS table was kicked and IFO misaligned. We adjusted PZT2 voltage by ~20 V in yaw such that IPPOS was restored. Then we could lock arms.

|
7771
|
Sat Dec 1 00:13:16 2012 |
Den | Update | Adaptive Filtering | ARMS and MC |
Quote: |
I actuate on ETMY for YARM and ETMX for XARM. For now I did adaptive filtering for both arms at the same time. I used the same parameters for xarm as for yarm.
I've notched 16 Hz resonance because it has high Q and I need to think more how to subtract it using FIR filter or apply IIR.
I'll try MC stabilazation method.
|
Adaptive filtering was applied to MC and X,Y arms at the same time. I used a very aggressive (8 order) butterworth filter at 6 Hz as an AI filter for MC not to inject noise to ARMS as was done before
Mu for MC was 0.2, downsample = 16, delay = 1. I was able to subtract 1 Hz. Stack subraction is not that good as for arms but this is because I used only one seismometer for MC that is under the BS. I might install accelerometers under MC2.
EDIT, JCD, 18Feb2013: Den remembers using mu for the arms in the range of 0.01 to 0.1, although using 0.1 will give extra noise. He said he usually starts with something small, then ramps it up to 0.04, and after it has converged brings it back down to 0.01. |
7770
|
Fri Nov 30 23:10:36 2012 |
Charles | Update | Electronics | Vertex Illuminators |
3 of the 4 remote controlled illuminators at the vertex are installed and can now be turned on via sitemap. There are a total of 15 controls for "Illum", but only the 3 labeled with MC, BS-PRM and ITMY-SRM are functional. |
7769
|
Fri Nov 30 22:11:50 2012 |
Den | Update | Adaptive Filtering | ARMS |
Quote: |
This is interesting. I suppose you are acting on the ETMY.
Can you construct the compensation filter with actuation on the MC length?
Also can you see how the X arm is stabilized?
This may stabilize or even unstabilize the MC length, but we don't care as the MC locking is easy.
If we can help to reduce the arm motion with the MCL feedforward trained with an arm sometime before,
this means the lock acquisition will become easier. And this may still be compatible with the ALS.
Why did you notched out the 16Hz peak? It is the dominant component for the RMS and we want to eliminate it.
|
I actuate on ETMY for YARM and ETMX for XARM. For now I did adaptive filtering for both arms at the same time. I used the same parameters for xarm as for yarm.
I've notched 16 Hz resonance because it has high Q and I need to think more how to subtract it using FIR filter or apply IIR.
I'll try MC stabilazation method. |
7768
|
Fri Nov 30 14:21:18 2012 |
rana | HowTo | Computer Scripts / Programs | The mystery of PDFs and you. As deep as the mystery of Rasputin. |
This is how to post PDF:
From DTT, print the plot as a postscript file.
Then use ps2pdf to make a archival PDF version (the flag is the key!). Example:
ps2pdf -dPDFX /home/controls/Desktop/darm.ps |
7767
|
Fri Nov 30 11:49:24 2012 |
Koji | Update | Adaptive Filtering | YARM |
This is interesting. I suppose you are acting on the ETMY.
Can you construct the compensation filter with actuation on the MC length?
Also can you see how the X arm is stabilized?
This may stabilize or even unstabilize the MC length, but we don't care as the MC locking is easy.
If we can help to reduce the arm motion with the MCL feedforward trained with an arm sometime before,
this means the lock acquisition will become easier. And this may still be compatible with the ALS.
Why did you notched out the 16Hz peak? It is the dominant component for the RMS and we want to eliminate it. |
7766
|
Fri Nov 30 11:38:35 2012 |
Steve | Update | PSL | foil removed from enclosure |
Aluminum foil replaced by sheet metal on Enclosure and AP table. |
7765
|
Fri Nov 30 09:59:53 2012 |
Steve | HowTo | General | How not to |
Clean cabinet S15 doors were left open. You have to lock it up! |
7764
|
Fri Nov 30 02:40:44 2012 |
Den | Update | Adaptive Filtering | YARM |
I've applied FIR adaptive filter to YARM control. Feedback signal of the closed loop was used as adaptive filter error signal and OAF OUT -> IN transfer function I assumed to be flat because of the loop high gain at low frequencies. At 100 Hz deviation was 5 dB so I've ignored it.
I've added a filter bank YARM_OAF to C1LSC model to account for downsampling from 16 kHz to 2 kHz and put low-pass filter inside.
I've used GUR 1&2 XYZ channels as witnesses. Bandpass filters 0.4-10 Hz we applied to each of them. Error signal was filters using the same bandpass filter and 16 Hz 40 dB Q=10 notch filter. As an AI filter I used 32 Hz butterworth 4 order low-pass filter. Consequently, AI, bandpass and notch filters were added to adaptive path of witness signals.
I've used an FIR filter with 4000 taps, downsampling = 16, delay = 1, tau = 0, mu = 0.01 - 0.1. Convergence time was ~3 mins.

|
7763
|
Thu Nov 29 09:58:06 2012 |
Den | Update | PEM | Decreased RMS in Seismometers |
Quote: |
[Den, Ayaka]
We found that seismometer was working and the calibration in the filter banks should have been wrong.
We turned off the all FM2 filter in RMS filter banks.
We also installed STS seismometer. It is under the BS. Now we have spectrum of three seismometers;
RA: the above plot is kind of unreadable and useless. Please replace with something legible and put in some words about why there is a wrong filter, what exactly it is, etc., etc. etc. And why would you leave in a filter which is not supposed to be on? We might as well leave a few secretly broken chairs in the control room...
|
First of all, STS-2 is in the end of X arm, GUR2 is under BS, GUR1 is in the end of Y arm.
BLRMS were small because we applied calibration from counts to um/s two times. In the past we had calibration in the RMS BP filter bank (vel2vel = FM2). Now we have calibration in the seismometer input filter bank so we can save calibrated _OUT channels. |
7762
|
Thu Nov 29 02:43:48 2012 |
Ayaka | Update | PEM | Decreased RMS in Seismometers |
Quote: |
The attached plots display RMS noise from various accelerometers and seismometers over the past 90 days. One can see how after the reinstallation of the seismometers in November, RMS from the GUR1Z and GUR1X channels decreases by a factor of about 100 from data in August. Additionally, the RMS over the course of the last 90 days has notably decreased in all instruments. In many cases, the RMS is only the result of inherent electronics noise, rather than from a signal.
|
The Image is replaced
[Den, Ayaka]
We found that seismometer was working and the calibration in the filter banks should have been wrong.
We turned off the all FM2 filter in RMS filter banks.
We also installed STS seismometer. It is under the BS. Now we have spectrum of three seismometers.
 
RA: the above plot is kind of unreadable and useless. Please replace with something legible and put in some words about why there is a wrong filter, what exactly it is, etc., etc. etc. And why would you leave in a filter which is not supposed to be on? We might as well leave a few secretly broken chairs in the control room... |
7761
|
Thu Nov 29 00:15:13 2012 |
Den, Koji | Update | IOO | MC WFS work |
Quote: |
The instability started about 48hour ago, that means my work on the AP table did not
made immediate trouble. But it does not mean anything.
For now, the WFS outputs are off. More work is needed to find what's wrong.
|
The problem was caused by low reflectivity of the mirror that splits MC reflected beam into two: first goes to trash, second - to WFS. Power before the mirror was 100mW, reflected beam that goes to WFS was 0.3mW. Using dataviewer we learnt that the beam intensity was ~5 times more in the past.
This happened because the mirror position was adjusted a few days ago. Its reflection depends on the angle of incidence and amount of light to WFS was significantly reduced. We could either increase the angle of incidence or use two mirrors with high reflectivity instead of this with high transmission.
We've chosen the second variant not to confuse anyone in future with non-45 degrees angles. We are now using one mirror with reflectivity 98% to direct most power to the trash while other 2% are directed using the second mirror to WFS path. We now have 0.7 mW on WFS1 and 1.3 mW on WFS2.
Then we adjusted WFS
- blocked the beam and run scripts/MC/WFS/WFS_FilterBank_offsets to calculate offsets in the WFS servo
- aligned MC and centered beams on WFS 1 and 2
- provided excitation to MC1 at 5 Hz (400 counts) and adjusted I&Q phase rotation
- adjusted the gain and changed it in MC autolocker (reduced from 0.25 to 0.15 as we now have more power of WFS as before)
We were able to close the loops. The phase margin is too low though, we need to improve feedback filters.

|
7760
|
Wed Nov 28 23:55:13 2012 |
Ayaka | Update | WienerFiltering | Sound on PSL |
I have been searching for the way we can subtract signal better since I could see the acoustic coupling signal remains in the target signal even though there are no coherence between them.
I changed the training time which is used to decide wiener filter.
I have total 10 minutes data, and the wiener filter was decided using the whole data before.
 
(Right: the performance with the data when the triangular sound was created. Left: the performance with the data when the gaussian sound was created.)
I found that the acoustic signal can be fully subtracted above 40 Hz when the training time is short. This means the transfer functions between the acoustic signals and MCF signal change.
However, if the wiener filter is decided with short-time training, the performances at lower frequencies get worse. This is because wiener filter do not have enough low-frequency information.
So, I would like to find the way to combine the short-time training merit and long-time training merit. It should be useful to subtract the broad-band coupling noise. |