40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 184 of 344  Not logged in ELOG logo
ID Date Author Type Categoryup Subject Text Attachments
  9999   Wed May 28 14:13:06 2014 manasaUpdateIOOMC relocked

    

       
            
  
  10017   Mon Jun 9 23:08:58 2014 JenneUpdateIOOMC board checkoutRana mentioned this in his elog entry re:
SLOW computer recovery, but I want to highlight
it:
  
  10038   Fri Jun 13 19:09:44 2014 KojiUpdateIOOA blown fuse found on the euro card crate at 1X2 (IOO) rack.[Rana Zach Koji]
We tracked down the MC locking issue
to be associated with the power supply problem.
  
  10039   Sat Jun 14 18:43:15 2014 ranaUpdateIOOMC Autolocker upgrades Somehow the caget/caput commands
are really slow. I'm not sure if this is
new behavior or not, but after changing values,
  
  10042   Mon Jun 16 12:58:50 2014 manasaSummaryIOORingdown recap A recap of the ringdown measurements made
at the 40m in mid 2012, the hardware that
was installed for the same and results from
 Ringdown_815.pdfMCringdown_cum.pdfcum_plot.png 
  10043   Mon Jun 16 15:32:12 2014 ranaSummaryIOORingdown recap  
To do this better:
1) Just step the analog input
  
  10064   Wed Jun 18 21:37:11 2014 KojiUpdateIOOMC REFL investigation[Jenne Koji]
We decided to check the situation
of the REFL MC beam path.
  
  10066   Wed Jun 18 22:34:44 2014 ericqUpdateIOOcaget frusrtation

    

       
            
  
  10078   Fri Jun 20 09:46:49 2014 manasaUpdateIOOMC WFS servo turned ONThe IMC stayed locked last night, but with 
a high REFL ~3.0. I found the WFS servo OFF;
so went ahead and enabled it. (Did somebody
  
  10225   Thu Jul 17 01:24:35 2014 ranaUpdateIOOMC / EOM Stability Mystery Solved!MC loop is near
unstable. Common gain reduced. Needs more
 MC_OLG.pdf 
  10235   Fri Jul 18 14:59:07 2014 EvanUpdateIOOMC servo TFs[Rana, Evan]
This morning we took several TFs
of the MC servo board using the HP4395A.
 mcServoTFSettings.pngMCtfs.pdf 
  10247   Mon Jul 21 13:58:33 2014 ericqUpdateIOOMC autolocker acting upThe autolocker claimed it was running and
blinking, but not doing anything (i.e. lock
bit was not updating and no switches or sliders
  
  10251   Tue Jul 22 08:36:08 2014 EvanUpdateIOOMC servo TFs

    

       
            
 MCtfExpectations.pdf 
  10303   Thu Jul 31 09:14:14 2014 ericqUpdateIOOMC stability Last night, I poked around to try
and see if I could reproduce the sketchy
MC behavior by exciting MC2 in a way that
  
  10310   Thu Jul 31 19:37:59 2014 KojiUpdateIOOSuccessful modification of the FSSQuick note:
Migration
of the 10Hz pole from the output stage of
  
  10314   Thu Jul 31 23:43:00 2014 KojiUpdateIOOModulation frequency adjustmentThe main IFO modulation frequency was adjusted
to match with the FSR of the IMC.
The new frequency is 11.066128 MHz.
  
  10316   Fri Aug 1 01:29:55 2014 KojiUpdateIOOPMC issue- PMC suddenly refused to lock.
- Investigated what's wrong
- Finally, I touched RF Output Adjust
  
  10317   Fri Aug 1 01:57:24 2014 KojiSummaryIOOMC auto lockerTo make MC auto locker running correctly,
mcdown and mcup were revised
I tried it by unlocking MC several
  
  10319   Fri Aug 1 08:55:34 2014 KojiSummaryIOOMC auto lockerIt seems that the MC auto locker and the
FSSSlow PID servo survived a night.
PC Drive is still angry occasionally.
 MC.png 
  10320   Fri Aug 1 10:40:48 2014 KojiSummaryIOOMC servo summing ampThe
summing amp is prepared to allow up to use
bipolar full range of the FSS box output
 Fast_PZT_IF.PDF 
  10321   Fri Aug 1 11:11:12 2014 KojiUpdateIOOCurrent IMC servo configurationThe comparison between the new and old
MC servo (FSS part) was attached.
- The new servo has the same DC
 diagram.pdf 
  10322   Fri Aug 1 12:49:06 2014 KojiSummaryIOOMC servo analysisReasoning to choose the current parameters:
FSS Common: 18dB
FSS Fast: 20dB
 MC_OLTF.pdfMC_Error_Common.pdfMC_Crossover.pdfMC_CLTF_Fast.pdf 
  10340   Wed Aug 6 17:29:36 2014 JenneUpdateIOOFSS offset changedThe MC has been unstable and unhappy for
the last several hours.  When I looked,
I saw that the FSS_FAST monitor has been
  
  10341   Wed Aug 6 21:22:09 2014 KojiUpdateIOOFSS offset changedThe fast feedback
should be around zero now!
  
  10343   Thu Aug 7 11:57:59 2014 KojiSummaryIOOMC servo analysisLISO Fit for the IMC open loop TF. The
data and liso source for the fitting were
attached in the ZIP file.
 MC_OLTF_Fit.pdfIMC_OLTF.zipMC_OLTF_estimated.pdf 
  10344   Thu Aug 7 12:25:14 2014 JenneUpdateIOOFSS offset changed

    

       
            
  
  10351   Fri Aug 8 12:39:19 2014 ericqSummaryIOOMC servo analysisI have measured the current boosted MC
CLG below 100kHz with an SR785. Swept sine
only could get me down to 10kHz, but I was
 mcLoopAug8.zipMCloopAug8.pdf 
  10354   Fri Aug 8 15:57:29 2014 ericqSummaryIOOMC servo analysis I did some further measurements,
to try and see what corresponds to what.
In the end I performed four measurements:
 OLTFs.pdfCLTFs.pdfmcLoopAug8.zip 
  10356   Fri Aug 8 18:08:12 2014 KojiSummaryIOOMC servo analysisThe closed gain I meant is the AO path:
Use IN2 to excite the MC loop and measure
IN1 using MON2(?). 
  
  10359   Sat Aug 9 14:35:28 2014 KojiSummaryIOOMC servo analysisEric's OLTF turned out consistent with
the AO path TF that has been measured by
me on Jul 31 (entry
 MC_OLTF_Fit.pdfliso.zipMC_CLTF_Fit.pdfMC_CLTF_new.pdfMC_OLTF_new.pdf 
  10363   Mon Aug 11 21:03:48 2014 ericq, ranaSummaryIOOMC demod measurementWe measured
the TF of the MC Demod board today. 
  
  10364   Mon Aug 11 22:07:31 2014 KojiSummaryIOOMC demod measurementSCLF-5!? It's surprising as the cut off
of the OLTF is just above 1Hz. cf
this entry
  
  10365   Mon Aug 11 23:32:54 2014 ericqSummaryIOOMC demod measurementHere's the magnitude plot of the board
TF. As mentioned above, this was done with
Marconi+Scope, so we were not able to get
 MCDemod.pdfdemodLP.txt 
  10370   Tue Aug 12 18:20:13 2014 ericqUpdateIOOFSS box TFsI made some measurements of the FSS box
today, to have TFs for a loop model, but
also to see what the difference between the
 FSSbox.pdfFSSfilt.pdfFSSdata.zip 
  10380   Wed Aug 13 23:08:17 2014 ranaUpdateIOOFSS box TFsAs EQ pointed out recently, we're injecting
into the FSS error point just after an RF
pi filter, but before the VGA. We wondered
 FSScomm.pdf 
  10391   Thu Aug 14 19:23:25 2014 ranaHowToIOOHow do I set the FSS offset to make the PZT voltage start at the right place? When the IMC locks, we want the FAST
OUT of the TTFSS box to be close to zero
volts. We also want the control signal from
  
  10392   Thu Aug 14 19:33:00 2014 JenneConfigurationIOOMoved MC2 spotLast night, and again just now, I used
the ./MC2_spot_[direction] scripts to center
the MC2 spot on the trans QPD.  The
  
  10406   Mon Aug 18 09:42:50 2014 KojiSummaryIOOMCREFL PD charcterizationRiju did the
measurement of the MCREFL PD.
I found data files in her directory
 MCREFLPD_transimpedance.pdfMCREFLPD_transimpedance_zoom.pdf 
  10424   Fri Aug 22 15:11:55 2014 andres, nicolasSummaryIOOMC WFS activity1. Before doing anything, we centered the
IOO QPDs.
2. With the WFS enabled, we offloaded
  
  10425   Fri Aug 22 15:58:02 2014 SteveSummaryIOOMC WFS activity 
 
 GoyphaseSet.png 
  10561   Thu Oct 2 20:54:45 2014 KojiUpdateIOOIMC WFS measurements[Eric Koji]
We made sensing matrix measurements
for the IMC WFS and the MC2 QPD.
 IMC_RIN_141002.pdfIMC_WFS_141002.pdf 
  10564   Fri Oct 3 13:03:05 2014 ericqUpdateIOOIMC WFS measurementsYesterday, Koji and I measured the transfer
function of pitch and yaw excitations of
each MC mirror, directly to each quadrant
 WFS1PIT.pdfWFS2PIT.pdfWFS1YAW.pdfWFS2YAW.pdfanalyzeWfs.zip 
  10565   Sun Oct 5 10:09:49 2014 ranaUpdateIOOIMC WFS measurementsIt seems clever, but I wonder
why use DTT and command line perl, instead
of using the FE lockins or just demod the
  
  10566   Sun Oct 5 23:43:08 2014 KojiUpdateIOOIMC WFS measurementsThere are several non scientific reasons.   
  10646   Tue Oct 28 14:07:28 2014 KojiUpdateIOOIMC WFS sensing matrix measurementLast night the sensing matrix for IMC WFS&QPD
were measured.
C1:IOO-MC(1, 2, 3)_(ASCPIT, ASCYAW)_EXC
 00.png 
  10647   Tue Oct 28 15:27:25 2014 ericqUpdateIOOIMC WFS sensing matrix measurement I took some spectra of the error
signals and MC2 Trans RIN with the loops
off
 45.png 
  10648   Tue Oct 28 20:47:08 2014 diegoUpdateIOOIMC WFS sensing matrix measurementToday I started looking into the WFS problem
and improvement, after being briefed by Koji
and Nicholas. I started taking some measurements
 6x 
  10653   Thu Oct 30 02:12:59 2014 diegoUpdateIOOIMC WFS sensing matrix measurement[Diego,Koji]
Today we took some measurements of
transfer functions and power spectra of suspensions
 12x 
  10681   Thu Nov 6 12:58:28 2014 KojiUpdateIOOWFS offset was resetIMC WFS operating point seemed to get degraded.
- IMC WFS feedback was relieved.
- WFS servo was turned off.
  
  10704   Wed Nov 12 20:11:41 2014 KojiUpdateIOOMC WFS gain reduced againMC WFS was oscillative at 1Hz. I've reduced
the servo gain further (x1, x1, x10, x1,
x1, and x10).
  
ELOG V3.1.3-