  16934   Tue Jun 21 18:41:46 2022 TomislavUpdateASCSimulation plotIn the attachment please find a comparison
of error signals of simulation and reality.
For C1:IOO-WFS1/2_PIT_IN1 excess signal ('belly')
 sens_output_comparison.png 
  16937   Tue Jun 21 22:22:37 2022 TomislavUpdateASCPlotsIn the attachment please find a comparison
of error signals of simulation and reality
after including air turbulence as input noise.
 sens_output_comparison_with_air_turbulence.png 
  16948   Sat Jun 25 22:18:41 2022 TomislavUpdateASCSimulation and reality comparisonsIn the attachment please find plots comparing
controller output, local damping output,
and error signals.
 sens_output_comparison_23_6_new.pngcontr_out_comparison_23_6_new.pnglocal_damp_out_comp_23_6_new.png 
  387   Thu Mar 20 17:45:36 2008 ranaSummaryASSAdaptive Filtering in the ASS systemOver the past couple weeks we (Matt, Alex,
Rob, me) have worked on getting an adaptive
filter
  
  428   Fri Apr 18 19:46:08 2008 ranaUpdateASScheck adaptiveI restarted the adaptive code today using
'startass' and 'upass'. 
I moved them into the scripts/ASS/ subdirectory.
 0052_xray_thm45.jpg 
  432   Mon Apr 21 12:58:42 2008 robUpdateASScheck adaptive[quote]

Caryn Palatchi (a Caltech undergrad who just
  
  579   Thu Jun 26 21:07:11 2008 ranaConfigurationASSdust & MC1I realized today, that yesterday while we
were trying to debug the adaptive noise canceler,
I turned
 Screenshot-2.png 
  981   Mon Sep 22 21:54:05 2008 ranaUpdateASSNew Wiener result with x10 gain in ACCThe 2 attached PDF files show the performance
of the Wiener filter code on 2 hours of data
with a 4000 tap filter on 64 Hz data. All
 f.pdf 
  1105   Sun Nov 2 20:44:58 2008 ranaUpdateASSWiener Filter performance over 5 hoursI took one 2 hour stretch of data to calculate
a MISO Wiener filter to subtract the Ranger
seismometer
 f.pngf1.png 
  1111   Mon Nov 3 22:35:40 2008 ranaUpdateASSWiener Filter performance over 5 hours[FONT=Comic Sans MS]To speed up the Wiener
filter work I defined a 256 Hz version of
the original 16kHz IOO-MC_L signal. The
 DAQ.pdf 
  1112   Tue Nov 4 00:47:53 2008 ranaUpdateASSWiener Filter performance over 5 hoursSame as before, but now with a working Ranger
seismometer.
 f2.pngf.png 
  1985   Fri Sep 11 17:11:15 2009 SanjitUpdateASSOAF: progress made[Jenne & Sanjit]
Good news: We could successfully
send filtered output to MC1 @ SUS.
  
  2434   Sun Dec 20 21:39:40 2009 rana, jenne, kiwamuUpdateASSOAF Model update and build instructionsAfter a lot of headache, I
got the OAF working again - read on for details.....................
  
  2437   Mon Dec 21 02:22:31 2009 rana, jenne, kiwamuUpdateASSOAF Model update and build instructionsThis allowed measuring the MC1 -> MCL
TF finally. Its mostly flat. Data saved as
Templates/OAF/OAF-MCLTF.xml
 Untitled.png 
  2438   Mon Dec 21 07:30:58 2009 ???UpdateASSOAF Model update and build instructions What does OAF stand for? The entry
doesn't say that. Also the acronym is not
in the abbreviation page of the wiki.
  
  2440   Mon Dec 21 10:09:06 2009 jenneUpdateASSOAF Model update and build instructionsOAF stands for Online Adaptive Filtering.
 We use the same computer which was once
the ASS. One of these days, we'd like to
  
  2441   Mon Dec 21 19:24:29 2009 ranaUpdateASSOAF Model update and build instructionsI fit the MC1 -> MCL TF using vectfit4.m
(from mDV). The wrapper file is mDV/extra/C1/
fitMC12MCL.m.
 mc12mcl.png 
  2442   Tue Dec 22 02:50:09 2009 rana, kiwamu, jenneUpdateASSOAF Feedaround ON and doing something goodKiwamu made the OAF screen functional today
- screenshot attached.
After this, I used the measured TF
 oaf.pngoaf.png 
  2449   Wed Dec 23 17:33:14 2009 ranaUpdateASSOAF Feedaround ON and doing something goodThe Rai box ran out of batteries a couple
of days ago and so the data is no good. I've
put the Ranger back on the SR560 for now
  
  4696   Wed May 11 23:02:52 2011 valeraUpdateASSDither angular stabilizitaion system updateThis is what was done in past two days:
- The ETMY and ITMY pitch and yaw
dofs are modulated at 40, 44, 42, 46 Hz respectively
  
  4709   Fri May 13 00:39:53 2011 valeraUpdateASSc1ass updateHere the status of the dither alignment
or c1ass:
- Both pitch and yaw centering on
 c1assqpds.jpg 
  4726   Mon May 16 11:47:59 2011 kiwamuUpdateASSc1ass update part IIThe medm screen for c1ass started being
modified to be more user-friendly.
The modification is still 
 c1ass.png 
  4795   Wed Jun 8 16:41:48 2011 valeraUpdateASSX and Y arm dither alignment status   BeamPositionIndicators.png 
  6723   Thu May 31 01:20:41 2012 JenneUpdateASSASS filter outputs are non-zero with no inputI was looking a little at ASS, while Yuta
was doing some Green transmitted DC PD work,
and I find that the output of some filters
 ASS_Yarm_crazyOutputs_30May2012.png 
  6980   Tue Jul 17 11:28:29 2012 JenneUpdateASSNames of DoF filters in ASS wrongThe names of the DoF filters in the ASS
loop were wrong.  The filters themselves
were correct (low pass filters at super low
  
  7017   Tue Jul 24 03:14:13 2012 JenneUpdateASSCalibration of MC ASS lockinsI wanted to check that the calibration
of the MC ASS lockins was sensible, before
trusting them forevermore.
  
  7074   Wed Aug 1 22:37:21 2012 JenneUpdateASSFilters installed in the ASSAs part of trying to figure out what is
going on with the ASS, I wanted to figure
out what filters are installed on which lockins.
 ASS_lockin_filters_1Aug2012.pdf 
  7075   Thu Aug 2 00:43:55 2012 JenneUpdateASSMajor cleanup of the ASS model[Jamie, Jenne]
We are trying to figure out what
the story is with the ASS, and in order to
  
  7081   Thu Aug 2 23:31:04 2012 JenneUpdateASSMajor cleanup of the ASS modelJamie re-redid the ASS model a few hours
ago.
I have just compiled it, and restarted
  
  7082   Fri Aug 3 03:24:13 2012 JenneUpdateASSNew ASS screensI wanted to try out the ASS tonight, but
I wanted some kinds of screens thrown together
so I would know what I was doing.  Turns
  
  7092   Mon Aug 6 17:15:15 2012 JenneUpdateASSFilter banks not workingI was trying to load some filters into
the ASS so that I can try it out, but for
some reason the filter banks aren't working
  
  7099   Tue Aug 7 00:22:10 2012 JenneUpdateASSFilter banks working

    

       
            
  
  7100   Tue Aug 7 03:20:56 2012 JenneUpdateASSASS setup, on, off scripts writtenI wrote new setup, on and off scripts for
the arm ass.  They take the arm as an
argument, so it's the same script for both
  
  7123   Wed Aug 8 20:34:29 2012 JenneUpdateASSTrouble measuring sensing matrixI turned on the ASS, without closing the
loops, to try to measure the sensing matrix. 
The Yarm was locked 
  
  7124   Wed Aug 8 20:50:39 2012 KojiUpdateASSTrouble measuring sensing matrixFrom the log, I couldn't understand what
has been done.
The procedure we should perform is
  
  7129   Thu Aug 9 00:23:11 2012 JenneUpdateASSTrouble measuring sensing matrix

    

       
            
  
  7131   Thu Aug 9 01:26:03 2012 KojiUpdateASSTrouble measuring sensing matrixThat's a good point, but I suspect
that you end up with the in-phase (0deg)
as the response of the IFO is immediate compared
  
  7135   Thu Aug 9 12:31:36 2012 JenneUpdateASSASS rebuilt againI was (in between Eric's measurements) driving
the YARM ASS dithers, and noticed that instead
of driving ITMY PIT, I was driving ITMX PIT.
  
  7137   Thu Aug 9 23:50:09 2012 JenneUpdateASSASS matrix measured, first ASS testKoji pointed out that I was being silly,
and rather than actually misaligning the
optics (by, say, changing their IFO Align
  
  8176   Wed Feb 27 00:56:01 2013 JenneUpdateASSMotivation for reactivating the ASSI am putting a little bit of brain power
into reviving the ASS, and I want to write
down what the motivation is, and what the
  
  8178   Wed Feb 27 02:21:55 2013 JenneUpdateASSMotivation for reactivating the ASSI have modified the MeasureSpotPositions.py
script to accept the arms as valid cavities
(it used to give an error "Sorry, this
  
  8204   Fri Mar 1 02:49:34 2013 JenneUpdateASSArm A2L measurementI haven't finished debugging the scripts
so that the measurement is fully automatic,
like the MC, but I did measure the arm spot
 QUAD1_1046168242.bmp 
  8205   Fri Mar 1 08:19:40 2013 SteveUpdateASSdrift Early morning drift in pitch. This
plot is meaningless because there is no real 
light on IP-Ang
 drift.png 
  8216   Mon Mar 4 09:51:26 2013 SteveUpdateASSIP-ANG is still not real  IP-ANG  is coming out of ETMY
without clipping. The beam is very high on
the pick off mirror at the end table but
 IP-ANG.png 
  8229   Tue Mar 5 01:43:04 2013 JenneUpdateASSArm A2L measurement script finishedIn either .../scripts/XARM or ...../scripts/YARM
run either A2L_XARM or A2L_YARM.
The wrapper script will, like the
 YARMdecenter.png 
  8494   Thu Apr 25 20:48:48 2013 KojiUpdateASSDen fixed the Yarm ASS scriptsI contacted Den about malfunctioning of
the Yarm ASS.
He found the scripts were modified
  
  8525   Fri May 3 01:24:25 2013 KojiUpdateASSDen fixed the Yarm ASS scriptsOutput matrices are added to ASS. Currently
ASS is based on the mirror bases.
I prefer to have the actuator bases
  
  8552   Wed May 8 18:33:02 2013 KojiUpdateASSYARM ASS - faster and more precise convergencePrecise arm alignment is more demanded.
as the PRMI locking requires good and reliable
alignment of the ITMs.
 YARM_ASS.pngScreenshot.png 
  8554   Wed May 8 22:36:42 2013 KojiUpdateASSXARM ASS (YARM ASS - faster and more precise convergence)Same ASS setup for the X arm has been
done.
Now
 XARM_ASS.png 
  9018   Fri Aug 16 13:25:50 2013 KojiUpdateASSASX model/screen cleaning up[Koji Manasa]
Yesterday we cleaned up the ASX model
and screens to have more straight forward
  
ELOG V3.1.3-