  7015   Mon Jul 23 21:54:48 2012 ranaUpdatePEMWeather Station Works!To get the code to run on c1pem1, we had
to move the old target back into the /cvs/cds/caltech/target/
directory.  It is in /cvs/cds/caltech/target/c1pem1/.
 Untitled.png 
  7016   Tue Jul 24 02:12:14 2012 MashaUpdatePEMBLRMS, MEDM, TriangulationToday I worked with the BLRMS channels,
re-triangulated the seismometers (the STS
is now on the very end of the Y-arm, while
  
  7017   Tue Jul 24 03:14:13 2012 JenneUpdateASSCalibration of MC ASS lockinsI wanted to check that the calibration
of the MC ASS lockins was sensible, before
trusting them forevermore.
  
  7018   Tue Jul 24 12:06:41 2012 MashaUpdatePEMNew RMS channels, New C1PEM OverviewAs Jenne suggested last night, I changed
the C1PEM overview in Epics. Previously,
the C1PEM_OVERVIEW.adl screen had two separate
 NewRMSFrames.png 
  7019   Tue Jul 24 15:17:10 2012 MashaUpdatePEMRMS Filters, PEM SitemapRMS Filters
How Den, Rana, and I chose RMS filters:
 GUR1Z0p3to1FilterCoherence.pngGUR1Z3to10FilterCoherence.pngGUR1Z3to10FilterSignal.png 
  7020   Tue Jul 24 18:33:12 2012 YaakovUpdateVIDEOCentering the MCR cameraJenne and I centered the MCR camera   
  7021   Tue Jul 24 21:16:55 2012 DenUpdatedigital noisequantization testI'm trying to get some intuition how digital
noise due to quantization shows up in iir
filters. I decided to do tests in C using
 iir_2.pngiir_8.png 
  7023   Wed Jul 25 11:22:39 2012 LizUpdateComputer Scripts / ProgramsWeek 6 updateThis week,
I made several modifications to the Summary
 P7230026.JPGP7230031.JPG 
  7024   Wed Jul 25 11:25:27 2012 MashaUpdateGeneralSummaryThis week, I have been mainly working on
my new neural network project, and working
with the BLRMS channels.
  
  7026   Wed Jul 25 11:41:00 2012 YaakovUpdateVIDEOCentering the MCR camera

    

       
            
  
  7027   Wed Jul 25 12:00:21 2012 YaakovUpdateSTACISWeekly updateThe past few days I've been working on
making a noise budget for the
  
  7029   Wed Jul 25 15:33:55 2012 janoschUpdateLSCringdown measurementWe did our first ringdown measurement on
the Y arm. First we tried to keep the arm
locked in green during the ringdown, but
 Rindown1.png 
  7030   Wed Jul 25 16:31:01 2012 JenneUpdateLSCYarm green locking to arm - PDH box saturating

    

       
            
  
  7031   Wed Jul 25 16:55:01 2012 DenUpdatedigital noisenotch, lowpass filters Direct Form 2 is noisy in the first
test. This is the one similar to Matt's in
his presentation. Input signal was a sine
 6x 
  7032   Wed Jul 25 17:35:44 2012 LizUpdateComputer Scripts / ProgramsSummary Pages are in the right place!The summary pages can now be accessed from
the "Daily Summary" link under
LOGS on the 40 meter Wiki page.
  
  7033   Wed Jul 25 22:16:36 2012 KojiUpdateLSCringdown measurementIs this the step response of the single
pole low pass???
It should have an exponential decay,
  
  7034   Wed Jul 25 23:03:22 2012 ranaUpdatedigital noisenotch, lowpass filtersIf the problem is the precision in DTT,
then why would the noise change when the
corner frequency of the filter is changed?
  
  7035   Thu Jul 26 02:44:17 2012 JenneUpdateIOOCentering the MCR camera[Yaakov, Jenne]
The
short version:
  
  7036   Thu Jul 26 10:22:03 2012 DenUpdatedigital noisenotch, lowpass filters

    

       
            
 same_bw.png16384_bw0p8.pngcorners_bw0p1.pngcorners_bw0p01.png 
  7037   Thu Jul 26 12:10:28 2012 DenUpdateCDSnew c1tst model for testing RCG code

    

       
            
  
  7038   Thu Jul 26 13:10:51 2012 janoschUpdateLSCmodelled ringdownWe fitted shutter and ringdown functions
to the ringdown data. It is not perfectly
clear how the power change due to the shutter
 Ringdown.png 
  7039   Thu Jul 26 15:43:03 2012 ranaUpdateLSCmodelled ringdownYou cannot use the digital system for this.
You hook up a scope to the transmitted light
as well as the incoming light (after the
  
  7040   Thu Jul 26 16:08:59 2012 YaakovUpdateSTACISNoise plot updateI have a tentative noise plot for the STACIS
that includes accelerometer noise, geophone
noise, and platform motion with the STACIS
 stacy_noise.bmpstacy_noise.figfeedbacks.bmpfeedbacks.fig 
  7041   Thu Jul 26 17:39:49 2012 DenUpdatedigital noisebiquad key is working I've filtered a 1 Hz sin wave excitation
with a notch filter inside c1sus and c1rfm
models. The biquad key is switched on in
 df2_bqf.pngdf2_bqf_spec.pngiir_psd_notch.pngiir_time_notch.png 
  7042   Thu Jul 26 21:31:44 2012 DenUpdatedigital noiseonline biquad works

    

       
            
 df2_bqf_lp.pngdf2_bqf_lp_spec.png 
  7043   Fri Jul 27 14:27:14 2012 JamieUpdateCDSnew c1tst model for testing RCG code

    

       
            
  
  7044   Fri Jul 27 14:28:36 2012 steveUpdateVACcold cathode gaugesOur cold
cathode 423 gauges are 10 years old.
They get insulated by age and show no ionization
 cc_gauges.png 
  7045   Fri Jul 27 14:30:49 2012 JamieUpdatedigital noisebiquad key is workingWhat is "DQF"?  Is that
the biquad?  And what is the difference
between DF1 and DF2?  Why don't you
  
  7046   Fri Jul 27 16:32:17 2012 JamieUpdateCDSRCG bug exposed by simple c1tst modelAs Den mentioned in 7043,
attempting to run the c1tst model was causing
the entire c1iscey machine to crash. 
  
  7047   Mon Jul 30 09:00:18 2012 steveUpdatePSLPMC is still not fixedThe PMC was locking right the way, but
it's transmission would not go up. 
Finally I get it back up by moving the "sticky"
 pmcA.pngpmcB.png 
  7048   Mon Jul 30 10:05:29 2012 JenneUpdatePSLPMC is still not fixed

    

       
            
  
  7049   Mon Jul 30 12:38:45 2012 JamieUpdateCDSMove to RCG 2.5 tag releaseI moved the RCG to the advLigoRTS-2.5 tag:

controls@c1iscey ~ 0$ ls -al
/opt/rtcds/rtscore/release
lrwxrwxrwx 1
  
  7050   Mon Jul 30 14:24:25 2012 DenUpdatedigital noisebiquad key is working

    

       
            
 lnf.png 
  7051   Mon Jul 30 15:49:16 2012 steveUpdateVACcc1 switched

    

       
            
 cc1changedfVtH.png 
  7052   Mon Jul 30 16:05:36 2012 DenUpdatedigital noisefilter checker We decided to write a script that
will check online filters for digital noise.
One method can be implemented using the following
 iir_psd_notch.pngiir_psd_lp.pngiir_time_lp.png 
  7053   Mon Jul 30 17:24:45 2012 YaakovUpdateSTACISRevised sensor noise plot; dead PZTThe geophone noise in my last eLog was
taken before
any amplification of the signal, but
 sensor_noise.bmpsensor_noise.bmpsensor_noise.fig 
  7054   Mon Jul 30 22:52:51 2012 YaakovUpdateSTACISGeophone calibrationTonight I looked at the signal from a geophone
and accelerometer side by side, in order
to see if they show the same ground motion
 7x 
  7055   Tue Jul 31 00:27:52 2012 DenUpdatePEMtrilliumWe have a Trillium for several days from
Vladimir. I've put seismometer inside the
foam box on linolium. I was not able to level
  
  7056   Tue Jul 31 08:01:22 2012 steveUpdateVACcc1 switched

    

       
            
 cc1h1d.png 
  7057   Tue Jul 31 15:17:58 2012 JamieUpdateCDSc1ifo medm screens checked into CSD userapps svnI moved the medm/c1ifo directory into the
CDS userapps svn at cds/c1/medm/c1ifo, and
then linked it back into the medm directory:
  
  7058   Tue Jul 31 15:24:53 2012 YaakovUpdateSTACISOpen loop gains and block diagramFirst, a quick note on the PZT I thought
I killed- it was most likely something in
the high voltage amplifier that broke, since
 z_OL.figz_OL.bmpx_OL.bmpstacis_block.bmpx_OL.fig 
  7060   Tue Jul 31 18:59:59 2012 JamieUpdateCDSupdated medm paths for MISC (IFO,CDS,VIDEO), IFO alignment scripts updated accordinglyIn an attempt to clean up the medm situation,
I did a bunch of further rearrangement and
cleanup.  Instead of having c1ifo, I
  
  7061   Tue Jul 31 19:34:55 2012 KojiUpdateSTACISOpen loop gains and block diagramWith your definition of the open loop gain,
G=+1 is the condition to have singularity
in a closed loop transfer function 1/(1-G).
  
  7062   Tue Jul 31 20:59:35 2012 JamieUpdateCDSfixing up MEDM snapshotsI've started to try to fix all the old
non-working medm snapshots.  I've made
a new snapshot directory, and some new snapshot
  
  7063   Wed Aug 1 10:07:16 2012 LizUpdateComputer Scripts / ProgramsWeek 7 UpdateOver the past week, I have continued refining the summary   
  7067   Wed Aug 1 11:50:49 2012 JamieUpdateCDSadded input monitors to LSC_TRIGGER library partI added an EPICS monitor to the input of
the LSC_TRIGGER part, to allow monitoring
the signal used for the trigger.  I
 trigmtrx.png 
  7069   Wed Aug 1 15:02:29 2012 JenneUpdateIOOIP POS QPD centeredJamie went out to look at IP POS, and the
beam was *way* off.  Even though our
alignment is still rough, we're kind of close
  
  7070   Wed Aug 1 15:14:20 2012 JenneUpdateIOOPSL Pointing QPD signals lost in late-June 2012I was looking into why we don't have any
light on the PSL pointing QPDs, and it turns
out that it has been this way since ~June
 IOO_QPDs_lost_midJune2012.pngIP_QPDs_lost_midJune2012.png 
  7071   Wed Aug 1 16:38:46 2012 steveUpdateSUSspare SRMU 03 optic movedSOS optics prepared to be hanged are moved
from the South Flow Bench to S15 Clean Cabinet.
SRMU 03 (1-25-2010) specification
 IMG_1464.JPGIMG_1465.JPGIMG_1466.JPG 
  7072   Wed Aug 1 17:04:22 2012 JenneUpdateSUSspare SRMU 03 optic moved

    

       
            
  