40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 173 of 344  Not logged in ELOG logo
Entry  Fri Nov 6 14:08:44 2020, gautam, Update, PSL, PMC re-locked 
The PMC servo railed and so I re-locked it at ~half range. I've been noticing that the diurnal drift of the PZT control voltage has been larger than
usual - not sure if it's entirely correlated with temperature on the PSL table. Anyway the cavity is locked again so all is good.
Entry  Tue Sep 15 10:57:30 2020, gautam, Update, PSL, PMC re-locked, RGA re-enabled RGAscan.pdf
The PMC has been unlocked since September 11 sometime (summary pages
are flaky again). I re-locked it just now. I didn't mess with the HEPA settings for now as I'm not using the IFO at the moment, so everything
should be running in the configuration reported here. 
Entry  Fri May 16 00:25:53 2014, rana, Update, PSL, PMC realign 
 Tonight I noticed that the drop in PMC transmission was ~1V, more than the usual of ~0.5V from the daily drift.
While re-aligning on the table, I noticed that the misalignment was not from either of the steering mirrors; i.e. I has to walk them both to get
the alignment back. This implies that the misalignment is generated far upstream. Maybe the the laser itself is moving. We need some updates from Steve's
Entry  Tue Dec 27 23:03:56 2011, kiwamu, Update, PSL, PMC realigned 
I have realigned the steering mirrors for PMC because the transmitted light had been at ~ 0.741
After the alignment it went back to ~ 0.850.
Entry  Mon Mar 5 03:22:54 2012, kiwamu, Update, PSL, PMC realigned 
I realigned the steering mirrors for the PMC. The trans value went up from 0.79 to 0.83.
The misalignment was largely in the pitch direction.
Entry  Fri Jan 9 19:18:51 2015, Jenne, Update, PSL, PMC realigned 
A few hours ago I tweaked up the alignment to the PMC.  It was really bad in pitch, and the transmission was down to about 0.711.
    Reply  Thu Jan 15 19:01:30 2015, ericq, Update, PSL, PMC realigned 
PMC realigned again... The transmission was down to 0.70, and the MC was having a hard time trying to autolock.
    Reply  Mon Jan 23 15:43:47 2012, Jenne, Update, IOO, PMC realignment 


    
        
            Quote:
        
        
            
            I realigned the incident beam to PMC at 23:30. The transmitted light went up from 0.78 to 0.83.
    Reply  Mon Jan 23 23:12:00 2012, kiwamu, Update, IOO, PMC realignment 
I have realigned the beam pointing to PMC. The transmitted light increased from 0.74 to 0.83.
The misalignment was mainly in pitch.
Entry  Wed Mar 4 11:16:37 2020, gautam, Update, PSL, PMC realignment PMCrealignment.png
I realigned the input pointing into the PMC this morning. Usually, the way I do this is to minimize any discernible mode structure in the PMC reflection
CCD image. Today, I noticed that making the DC reflection go down also makes the DC transmission go down. Possibilities:


we are sampling slightly different spots inside the PMC cavity which change the buildup by ~2-3%.
we are misaligned on the
Entry  Thu Jan 19 23:34:52 2012, kiwamu, Update, IOO, PMC realignment and HEPA 
I realigned the incident beam to PMC at 23:30. The transmitted light went up from 0.78 to 0.83.
Also I decreased the HEPA level down to 20 % for the night time locking.
Entry  Fri Nov 1 19:09:01 2013, rana, evan, Configuration, PSL, PMC reflected beam nonsense 
 While looking at the PMC REFL beam for the AOM diffracted beam, we noticed that although only one beam exists between the PMC and the first steering
mirror, there are two afterwards and they both go to the PMC REFL  RFPD!!! This is madness. We only want one beam on our PDH diode.
The reason that we have two beams is that that first steering mirrors is actually a (W1-PW-1025-UV-1064-45P) non-wedged window with an AR coating
Entry  Mon Sep 2 15:22:57 2013, Jenne, Update, PSL, PMC relocked 
 The PMC was locked on an LG 10 mode (or something like it), for at least the last 8 hours.  I relocked it on the regular 00 mode, and it's
fine now.  
Also, in CDS news, I did an mxstream restart (the RCG upgrade is supposed to make this not an issue anymore...), and did a "diag reset"
Entry  Sun May 4 14:20:04 2014, ericq, Update, IOO, PMC relocked 
The PMC has been unlocked for ~23 hours. FSS slow was at ~-1.5 V. I zeroed it, and relocked the PMC, transmission is ~0.81V. MC with WFS came back fine.
Entry  Wed May 21 22:15:37 2014, ericq, Update, PSL, PMC relocked 
PMC has been unlocked for ~4hrs, not sure why. It's servo gain was down at -10dB...
Relocked with transmission of .76V, MC locks fine with WFS, transmission of 15.5k.
    Reply  Mon May 26 20:10:14 2014, ericq, Update, PSL, PMC relocked 
I came in and PMC transmission was at 0.5V, and ETMX was swinging around a lot, (LSC mode was on). 
Turning off oplevs let ETMX calm down. I realigned the PMC to 0.82V. 
MC wouldn't relock, it looked misaligned in pitch and yaw on MC camera.
Entry  Tue Mar 10 14:47:05 2015, manasa, Update, PSL, PMC relocked 
PMC was locked in a bad state. FSS slow actuator adjust was at ~ -0.7 and PZT voltage at ~45.

So I set these right by moving the appropriate sliders and relocked it. FSS slow actuator adjust brought back to zero and PZT voltage ~115. PMC
trans after relock is 0.789.
Entry  Sat Mar 12 22:23:37 2016, rana, Summary, IOO, PMC relocked 
Found it locked on TEM01 mode.

Sweets in the fridge for non-PhD holders, courtesy of the highest levels of Caltech.
Entry  Thu Jul 17 08:30:15 2008, steve, Update, PSL, PMC relocked manually pmc4d.jpg
The PMC pzt HV and the servo gain adj. are railing at max this morning

Why is it on the decreasing side of FSS_RTTEMP slope?
Entry  Tue May 13 00:46:58 2014, rana, HowTo, PSL, PMC relocking 
The PMC runs out of range sometimes due to the daily temperature swing. The voltage swings up after sunset and then starts to swing down before sunrise.
So when you relock the PMC at the beginning of the locking night, the mnemonic from the PMC is:
Sun Go Low, Lock Me Voltage Low.
Entry  Mon Dec 15 22:40:09 2014, rana, Summary, PSL, PMC restored SadToastFace.jpg
 Found that the PMC gain has been set to 5.3 dB instead of 10 dB since 9 AM this morning, with no elog entry.
Entry  Mon Jul 7 16:39:09 2014, manasa, Update, PSL, PMC ringdown setup PMC_ring.png
I moved stuff on the PSL table to accommodate the PMC ringdown setup.
I used the beam that leaks from the steering mirror at the PMC transmission that was dumped to a razor blade dump. I installed a Y1 to steer the
beam to the ringdown PD. Power in the beam 75mW.
    Reply  Mon Jul 7 23:19:55 2014, rana, Update, PSL, PMC ringdown setup 


    
        
            Quote:
        
        
            

           I moved stuff on the PSL table to accommodate the PMC ringdown setup.
    Reply  Wed Jul 9 16:33:05 2014, manasa, Update, PSL, PMC ringdown setup 


    
        
            Quote:
        
        
            

           
            
                
           
Entry  Wed Jul 30 13:09:40 2008, josephb, Eric, Configuration, PSL, PMC scan experiment 
We turned the PSL power down by a factor of 4, blocked one half of the Mach Zehnder and scanned the PMC by applying a ramp signal to PMC PZT.  Eric will
adding plots later today of those results.
Entry  Tue Sep 23 11:17:59 2008, steve, Update, PSL, PMC scattering spot rainbow.pngpmcclip.png
The PMC output side has a new madly scattering spot at chamfer 2 o'clock position
Entry  Mon Aug 25 14:18:36 2008, Jenne, Update, PSL, PMC servo board is fixed 
The PMC servo board is back in place, all fixed up with a shiny new resistor.  The PMC locks, and the MC locks (I'm not saying anything either way about
how long the MC will stay locked, but it is locked for now).  The resistor is connected to the connector using a short piece of wire, so this problem won't
happen again, at least with this connector on this board.
    Reply  Wed Nov 18 16:51:58 2015, Koji, Summary, PSL, PMC servo calibration PMC_err_cal.pdf
Summary

The PMC servo error (MIX OUT MON on the panel) and actuation (HV OUT MON) have been calibrated using the swept cavity.

Error signal slope in round-trip displacement: 2.93e9 +/- 0.05e9 [V/m]
Entry  Wed Jul 9 21:43:41 2014, Jenne, Update, Electronics, PMC servo card modifications in DCC 
[Rana, Jenne]
We have decided to keep better track (using new-fangled digital "computers") of our modifications
to electronics boards.  
    Reply  Sun Jan 26 13:47:00 2020, gautam, Update, PSL, PMC servo characterization elecTFs.pdfVGAchar_postFix.pdfVGAlinearity_postFix.pdfnewOLTFs.pdf
Summary:


I investigated the stage-by-stage transfer functions of the PMC servo up till the HV stage. See Attachment #1. There were no unexpected features.
I replaced the AD602
Entry  Mon Jan 20 20:20:36 2020, gautam, Update, PSL, PMC servo checkout PMCsweep.pdfOLTFmeas.pdf
Summary:

The PDH discriminant of the PMC servo was measured to be ~0.064 GV/m.
This is ~50 times lower than what is reported here. Perhaps this is a signature of the infamous
    Reply  Mon Nov 16 19:05:59 2015, Koji, Summary, PSL, PMC servo circuit review, follow up measurements 
PMC follow up measurements have been done. The servo circuit was reviewed.

Now the PMC, IMC, X/Y arms are locked and aligned waiting for the IFO work although I still think something is moving (ITMX?)
as the FPMI fringe is quite fast.
    Reply  Mon Nov 16 21:32:49 2015, Koji, Summary, PSL, PMC servo circuit review, follow up measurements 
The result of the precise inspection for the PMC servo board for the 40m was done.

The record, including the photo of the board, can be found at https://dcc.ligo.org/D1400221-v2

- I found some ceramic 1uF caps are used in the signal path. They have been replaced with film caps by WIMA.
    Reply  Tue Nov 17 16:21:10 2015, Koji, Summary, PSL, PMC servo circuit review, follow up measurements 
I'm still analyzing the open loop TF data. Here I report some nominal settings of the PMC servo

Nominal phase setting: 5.7
Nominal gain setting: 3dB
    Reply  Thu Jan 23 22:10:01 2020, gautam, Update, PSL, PMC servo pulled out 
While I have the board out, I'll try and do a thorough investigation of TFs and noise of the various stages. There is no light into the IFO until this is done.





I
    Reply  Fri Jan 24 15:42:08 2020, gautam, Update, PSL, PMC servo restored 
The PMC servo was re-installed at ~345pm. HV supplies were re-energized to their nominal values. I will update the results of the investigation shortly.
The new nominal PMC servo gain is +9dB.




Quote:


    Reply  Mon Jun 13 09:08:17 2016, Steve, Update, PSL, PMC slow drift PMCslowDrift.png
The PMC transmission slow degration or it's input beam is not stable.

 
Entry  Tue Feb 15 11:57:06 2011, steve, valera, Configuration, PSL, PMC swap P1070421.JPGP1070423.JPG
 We swapped the PMC s/n 2677 for s/n lho006.
The table below summarizes the power levels before and after the PMC swap.

    
        
             
            old
Entry  Tue Jul 15 10:24:57 2008, steve, Update, PSL, PMC temp & pzt voltage pmctemp.jpg
The PMC pzt HV was happy with no HEPA temp stability.
Can we thermally insulate the pmc ?
Entry  Thu Jul 28 19:49:12 2011, Sonali, Update, PSL, PMC trans beam aligned. 
Kiwamu and I aligned the PMC transmitted beam the incident beam going to PMC today.
I learnt how to lock the PMC using the digital controls.
Entry  Wed Jul 16 15:59:04 2008, josephb, Eric, Configuration, Cameras, PMC trans camera path 
In order to reduce saturation, we placed a Y1 plate (spare from the SP table) in transmission just before the GC650 camera looking at the PMC transmision.
 The reflection (most of the light) was dumped to a convient razor blade dump.  We also removed the 0.3 and 0.5 ND filters and placed them in the 24 hour
loan ND filter box.
Entry  Mon Sep 22 18:54:54 2008, Jenne, Update, PSL, PMC transfer functions with various brick-on-top configurations PMC_OLG_100Hz_to_100kHz.pngPMC_OLG_5kHz_to_30kHz.png
Attached below is a graphical summary of different things that I have tried putting on the PMC to reduce the noise in the loop.  The motivation behind these
measurements is the current inability here at the 40m to increase the UGF of the PMC.  This is part of a broader ISS loop/gain/noise problem that we are
having, which is causing Rob's locking efforts to have trouble.  (The ISS is next on the to-do list, after we find the best configuration for the PMC,
    Reply  Thu Apr 22 15:15:26 2021, gautam, Update, PSL, PMC transmission 
I was a bit surprised by these numbers suggesting the PMC transmission is only 50-60%. I went to the table today and confirmed that it is more like 85%
(1.3 W in, 1.1 W transmitted, both numbers from with the FieldMate power meter), as I claimed
in 2019. Even being conservative with the power meter errors, I think we can be confident T_PMC will be >80% (modulo any thermal effects with higher
    Reply  Thu Apr 22 15:34:54 2021, Anchal, Update, PSL, PMC transmission 
Koji mentioned that the mode of the laser is different for lower diode currents. So that might be the reason why we got less transmission at the low
input power but more afterward.
Entry  Fri Jan 23 10:00:21 2009, steve, Update, PSL, PMC transmission is down pmc4d.jpg
The PMC transmission is going down.
I have not relocked the PMC yet.
    Reply  Fri Jan 23 14:00:02 2009, Yoichi, Update, PSL, PMC transmission is down LaserPower.png
[quote]The PMC transmission is going down.
I have not relocked the PMC yet.[/quote]
Entry  Wed Feb 3 07:57:01 2010, steve, Update, PSL, PMC transmission is low pmct40d.jpg
The low PMC transmission alarm was on this morning. The PMC alignment needs a touch up.
Entry  Mon Jun 9 17:32:14 2008, Yoichi, Configuration, PSL, PMC transmittance 
I checked the current PMC transmissivity at a low power.
The input laser power to the PMC was reduced to 75mW by rotating the HWP in front of the PBS.
In this configuration, the output power from the PMC was 50mW. So the transmittance is about 66%.
Entry  Fri Jun 13 11:17:25 2008, Yoichi, Update, PSL, PMC transmittance at high power 
We received a new cable for the Scientech calorimeter. So I measured the transmittance of the PMC at higher power.

Summary:
Entry  Fri Jun 20 02:20:33 2008, Yoichi, Update, , PMC transmittance degradation pmc_trans_long_trend.pdfpmc_trans_improvement.pdf
The PMC transmitted light power has been degrading constantly for last two weeks (see the attachment 1).
I went down to 2.55V.
The output of the MOPA is constant during this period. More strangely, the reflected power from the PMC is also constant.
ELOG V3.1.3-