  6822   Sat Jun 16 01:03:21 2012 yutaUpdateGreen Lockingused longer delay line for mode scan[Mengyao, Yuta]

Last night, I used 1.5 m delay line
 YarmScan20120615.png 
  6823   Sat Jun 16 12:03:41 2012 ZachUpdateGreen Lockingscanned Y arm for 5FSRIs that time stamp really correct?
I wanted to look at the signal closely to
see if I could get any feeling for why it
  
  6824   Sat Jun 16 13:01:17 2012 yutaUpdateGreen Lockingscanned Y arm for 5FSR

    

       
            
 YarmScanDV.png 
  6825   Sat Jun 16 18:17:00 2012 yutaUpdateGreen LockingY arm length using 5FSR scanCalibrating error signal to beat
frequency;
  I injected 0 dBm RF sine wave
 ALS-BEATY_COARSE_I_IN1_DQ.pngCalibYarmScan20120614_2.png 
  6826   Sat Jun 16 18:51:44 2012 KojiUpdateGreen LockingY arm length using 5FSR scan

    

       
            
  
  6827   Sat Jun 16 19:32:11 2012 yutaUpdateGreen LockingY arm length using 5FSR scanI know!
But I think there's some error (~
10% ?) in calibrating the beatbox. In elog
  
  6829   Mon Jun 18 16:23:59 2012 JenneUpdateLockingLSC trigger updateThe LSC triggers for the individual filter
modules in a filter bank now works. 
This is handy so that boosts can come on
  
  6831   Mon Jun 18 23:38:39 2012 JenneUpdateLSCAdded LSC channels to framesSince the .ini files get overwritten every
time a model is compiled now, we need to
put all channels we want saved to frames
  
  6832   Mon Jun 18 23:54:31 2012 yutaUpdateGreen Lockingphase tracker for ALS[Koji, Jenne, Yuta]

Summary:
 newIQLOCK.pngYarmScan20120618.pngfine8FSRscan.png 
  6834   Tue Jun 19 23:36:19 2012 yutaUpdateLSCcalibrated POY error signal[Jenne, Yuta]

We calibrated POY error signal(C1:LSC-POY11_I_ERR).
 LSCyarmTF_usingITMY.pngLSCyarm_HAover1plusG.pngPOYerrorcalibration.png 
  6835   Wed Jun 20 00:01:04 2012 JenneUpdateLSCcalibrated POY error signal[Yuta, Jenne]
We have measured the out of loop
residual motion of the Yarm while locked
 LSC_POY_11_I_ERR_calib_19June2012.pdfPOY_calib_19June2012_FiltBankSettings.png 
  6836   Wed Jun 20 00:02:16 2012 yutaUpdateGreen Lockingslower scan using phase tracking ALSFor those of you who want to see plots
from slower scan.
 YarmScan20120619.png 
  6837   Wed Jun 20 01:02:20 2012 JamieUpdateGreen LockingRF amp removed from X arm ALS setupI very badly forgot to log about this in
the crush of surfs.
I removed Koji's proto-beatbox RF
  
  6838   Wed Jun 20 16:37:11 2012 yutaUpdateLockingETMX 1064 trans camera[Jenne, Yuta]

We made ETMXT camera working.
  
  6840   Wed Jun 20 18:09:23 2012 yutaUpdateLockingboth arms aligned, ITMX oplev centered[Jenne, Yuta]

We aligned FPMI. I also centered ITMX
 FPMIalignment2010620.png 
  6841   Wed Jun 20 18:43:57 2012 yutaUpdateLSCcalibrated POX error signal[Jenne, Yuta]

We did the same calibration for POX.
 LSCxarmTF_usingITMX.pngLSCxarm_HAover1plusG.pngPOXerrorcalibration.png 
  6842   Thu Jun 21 01:58:29 2012 JenneUpdateGreen LockingXgreen preparations[Yuta, Koji, Jenne]
Lots
of small things happened tonight, in preparation
  
  6844   Thu Jun 21 09:01:18 2012 steveUpdateSTACISthe resurrection of STACIS -surfThere is a small wood cabinet under the
south end flow bench, labeled STACIS.
Unit is complete with extension cards
 IMG_1364.JPG 
  6845   Thu Jun 21 09:10:08 2012 steveUpdatePEMflow bench must be running all timesThe south end flow bench HEPA filter should
be run all times. You can turn it off for
a measurement or two but remember we are
  
  6846   Thu Jun 21 12:13:35 2012 JenneUpdatePEMflow bench must be running all times

    

       
            
  
  6847   Thu Jun 21 12:56:49 2012 yutaUpdateLockingETMX 1064 trans camera

    

       
            
 Xarm_EndTableLayout_NewTransCamera.png 
  6848   Thu Jun 21 15:00:55 2012 steveUpdateSAFETYSURFs 2012 safety trainingMasha, Eric, Yaakov, Liz and Sasha received
40m specific basic safety training.
 surfs2012.JPG 
  6849   Thu Jun 21 15:36:51 2012 yutaUpdateLockingX arm alignmentI aligned X arm so that the beam spot comes
roughly on the center.
  
  6850   Thu Jun 21 20:07:18 2012 JamieUpdateGreen LockingImproved beatbox returnsI've reinstalled the beatbox in the 1X2
rack.  This improved version has the
X and Y arm channels stuffed, but just one
  
  6851   Fri Jun 22 02:21:57 2012 JenneUpdateGreen Locking2 arm ALS - Success!!!![Yuta, Jenne]
We
 P6210140.AVIspeedy_gonzales-5257.jpg 
  6852   Fri Jun 22 03:37:42 2012 KojiUpdateGreen Locking2 arm ALS - Success!!!!Are
these correct?
1. It is a nice work.
  
  6853   Fri Jun 22 10:52:18 2012 yutaUpdateGreen Locking2 arm ALS - Success!!!!Answers to questions from Koji.
  
  6854   Fri Jun 22 13:37:17 2012 JenneUpdateComputersfb lost connection...Perhaps related to the fact that Jamie
is copying a lot of stuff over the network
to back up Ottavia before converting her
  
  6855   Fri Jun 22 17:51:04 2012 JenneUpdateCamerasGreen Trans camera repositioning attempt[Yuta, Jenne]
We tried to find a different place,
not in the main green transmitted beam path,
  
  6856   Fri Jun 22 19:52:47 2012 JamieUpdateComputersottavia reconfigured as CDS workstationottavia has been reinstalled with Ubuntu
10.04 LTS, and has been configured as a CDS
workstation.
 workstation-setup.sh 
  6858   Fri Jun 22 20:58:15 2012 JenneUpdateGreen LockingCalibrated POX spectra - Xarm stabilized by ALS[Yuta, Jenne, Koji]
We stabilized the Xarm using the
ALS and took a spectrum of POX as our out
 POX11_I_ERR_calib_residualCavityMotion_better.pdf 
  6859   Sat Jun 23 02:29:18 2012 yutaUpdateGreen LockingX arm mode scan resultsX
arm finesse is 416 +/- 6, mode-matching ratio
is 91.2 +/- 0.3%
 XarmScan20120623.pngfine8FSRscanXarm.png 
  6860   Sat Jun 23 18:44:15 2012 steveUpdateGeneralpower surge has no effect on the labI was notified by CIT Utilities that there
was a power surge or short power outage this
after noon.
  
  6862   Sun Jun 24 00:10:45 2012 yutaUpdateGreen Lockingcurrent beat electronicsI moved amplifiers for beat PD at PSL table
to 1X2 rack. Current beat setup from PD to
ADC is shown below. Setup for X beat and
 beatsetup20120623.png 
  6863   Sun Jun 24 23:42:31 2012 yutaUpdateComputer Scripts / ProgramsPMC lockerI made a python script for relocking PMC.
It currently lives in /opt/rtcds/caltech/c1/scripts/PSL/PMC/PMClocker.py.
  
  6864   Mon Jun 25 08:21:40 2012 steveUpdateGeneralAC power disturbance on Sat

    

       
            
 powerdisturbed.png 
  6866   Mon Jun 25 11:23:14 2012 JenneUpdateComputerstdsavg not working

    

       
            
  
  6868   Mon Jun 25 15:07:49 2012 yutaUpdateIOOMC beam spot trendI adjusted MC WFS offsets using /opt/rtcds/caltech/c1/scripts/MC/WFS/WFS_FilterBank_offsets.
Beam spot positions on MC mirrors
 MCdecenter.png 
  6869   Mon Jun 25 15:19:07 2012 YaakovUpdatePEMAdded microphone channels, moved accelorometer channelsJenne and I renamed the mic channels Den
created (elog
6664) to MIC_1, MIC_2, etc from the original
 channels.png 
  6871   Mon Jun 25 17:48:27 2012 yutaUpdateComputer Scripts / Programsscript for finding IR resonance using ALSI made a python script for finding IR resonance
using ALS. It currently lives in /opt/rtcds/caltech/c1/scripts/ALS/findIRresonance.py.
 findIRresonance20120625.png 
  6872   Mon Jun 25 21:54:52 2012 DenUpdateComputer Scripts / ProgramsPMC locker

    

       
            
  
  6873   Tue Jun 26 00:52:18 2012 yutaUpdateComputer Scripts / ProgramsPMC locker

    

       
            
  
  6875   Tue Jun 26 22:37:43 2012 yutaUpdateIOOenergized OMC stages[Koji, Yuta]

We checked that PZTs between SRM and
  
  6878   Wed Jun 27 11:27:49 2012 LizUpdate First Week Update!This week, the
other SURF students and I got          
  
  6879   Wed Jun 27 11:33:28 2012 MashaUpdateGeneralFirst Week UpdateThis week I wrote Matlab code, most of
which can be found in /users/masha
First, I wrote a simulation seismicFilter.m
  
  6883   Wed Jun 27 15:10:34 2012 JamieUpdateComputer Scripts / Programs40m summary webpages moveI have moved the summary pages stuff that
Duncan set up to a new directory that it
accessible to the nodus web server and is
  
  6884   Wed Jun 27 16:23:12 2012 yutaUpdateIOOAS and REFL on AP table alignedI touched steering mirrors for AS and REFL
at AP table.
AS beam and REFL beam now hits cameras
  
  6885   Wed Jun 27 23:54:21 2012 yutaUpdateComputer Scripts / Programsimage capturing scriptMike J. came tonight and he fixed Sensoray
(elog #6645).
He recompiled it and fixed it.
 AS_1024901004.bmp 
  6886   Thu Jun 28 00:50:48 2012 yutaUpdateLockingPRMI work started, commissioning planMy goal for tonight was to lock PRMI,
 grasp the current situation
by my eye,
 POP_1024903948.bmpREFL_1024903929.bmpAS_1024903921.bmp 
  6887   Thu Jun 28 01:44:57 2012 KojiUpdateLockingPRMI work started, commissioning planTo be fair, this is Kiwamu's idea. And
nothing is reasonable before it is confirmed
quantitatively.
  
ELOG V3.1.3-