40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 171 of 344  Not logged in ELOG logo
ID Date Author Type Categoryup Subject Text Attachments
  2884   Thu May 6 01:06:16 2010 KojiUpdateIOOMC spot centering cont'd (Triumph)Zach and Koji,
We
finally aligned the incident beam enough
  
  2899   Sat May 8 02:38:08 2010 KojiSummaryIOOMC incident powerAs per Steve's request I checked the
MC incident power as a function of time.
The output is negative: the lower
 MC_input.png 
  2900   Sat May 8 03:09:15 2010 KojiUpdateIOOSteering around MCAfter the MZ-removal work:
- I found that the input steering
(IM1) was right handed. This was different
  
  2918   Wed May 12 03:56:54 2010 KojiUpdateIOOFaraday alignedZach and Koji
The old small MMT was removed and
wrapped by Al foils.
  
  2928   Thu May 13 23:59:46 2010 ZachSummaryIOOMC table leveled After the recent removal of the old
IMMT and the relocation of the Faraday isolator,
the MC table was tilted a bit (southward
  
  2929   Fri May 14 03:30:45 2010 KojiSummaryIOOMC table leveledThanks Zach.This was a great job.
It was not mentioned but: was the
Faraday clamped down on the table?
  
  2931   Fri May 14 10:33:01 2010 ZachSummaryIOOMC table leveledAh... no, I didn't. That explains why there
were loose dogclamps on the table. I wrapped
them in foil and put them on the clean cart.
  
  2935   Sat May 15 04:13:33 2010 KojiSummaryIOOMC table leveledFixing at the next time is absolutely OK.

  
  2938   Mon May 17 02:10:10 2010 KojiConfigurationIOOHow to lock / align the MCLet
me remind you how to lock and align the IMC
To lock
  
  2941   Mon May 17 19:42:11 2010 JenneUpdateIOOFirst steps toward MC mode measuring[Jenne, Kevin, Steve]
We made some progress toward getting
the MC's beam profile measured.  In
  
  2942   Tue May 18 01:40:56 2010 KojiUpdateIOOFirst steps toward MC mode measuringOK. Don't worry. This is just an initial
confusion which we also had for the suspensions
a while ago.
  
  2945   Tue May 18 12:04:13 2010 robUpdateIOOFirst steps toward MC mode measuring


   
        
            
  
  2949   Tue May 18 16:44:35 2010 KojiUpdateIOOFirst steps toward MC mode measuringHere is the upadted list http://lhocds.ligo-wa.caltech.edu:8000/40m/Upgrade_09/Optics

  
  2950   Tue May 18 23:03:08 2010 JenneUpdateIOONo real progress....[Jenne, Kevin]
No real progress today.  We
opened the chambers and again tried to lock
  
  2952   Wed May 19 16:00:18 2010 JenneUpdateIOOHooray! We locked the MC! (and some other stuff)[Jenne, Kevin]
We opened up the MC chambers again,
and successfully got the MC locked today! 
  
  2954   Wed May 19 22:28:05 2010 KojiUpdateIOOHooray! We locked the MC! (and some other stuff)Good! What was the key?
The MC2 spot looks very high, but
don't believe the TV image. Believe the result
  
  2964   Fri May 21 00:51:06 2010 JenneUpdateIOOFirst MC mode measuring (hopefully) done[Jenne, Kiwamu, Steve]
Round 1 of measuring the MC mode
is pretty much done.  Yay.
  
  2977   Tue May 25 00:10:24 2010 ZachUpdateIOOIMC table leveled againThe IMC table had to be leveled again,
for two reasons: 1) It was un-leveled when
Jenne and Kiwamu removed an extra beam dump
  
  2985   Tue May 25 17:09:22 2010 KojiUpdateIOOBeam Profile After Mode CleanerVery nice as usual. Can you add the curve
to show the ideal mode of the MC on the profile
plot?
  
  2986   Tue May 25 17:22:56 2010 KevinUpdateIOOBeam Profile After Mode Cleaner

    
        
 mcfit.png 
  2987   Wed May 26 00:50:16 2010 JenneUpdateIOOMirrors moved in prep for round 2 of MC mode measuring[Jenne, Kevin, Kiwamu]
We moved some optics in preparation
for measuring the MC mode after the first
  
  2991   Wed May 26 14:28:01 2010 KojiUpdateIOOMirrors moved in prep for round 2 of MC mode measuringThat's true. But I thought that you measured
the mode after those optics and the effect
of them is already included.
  
  2993   Wed May 26 15:34:00 2010 JenneUpdateIOOMirrors moved in prep for round 2 of MC mode measuring


   
        
            
  
  3013   Fri May 28 23:21:52 2010 KojiUpdateIOOMC alignmentHm... You touched the optics between the
MC and the Faraday... This will lead us to
the painful work.
  
  3015   Sun May 30 15:33:21 2010 AlbertoConfigurationIOOmode cleaner and air conditioningThe mode cleaner is locked and the air
conditioning is full on. So the the air conditioning
doesn't seem to be so important for the lock
  
  3019   Mon May 31 00:10:18 2010 kiwamuUpdateIOOMC alignment  [Alberto, Kiwamu]
The MC
  
  3020   Mon May 31 03:38:48 2010 KojiUpdateIOOMC alignmentRemember
that you only can introduce the axis translations
from the PSL table.
 MC_spot_centering.png 
  3021   Mon May 31 17:47:34 2010 kiwamuUpdateIOOtoday's plan : MC alignment[Alberto, Kiwamu]
0. have a coffee and then dress up
the clean coat.
  
  3026   Tue Jun 1 16:29:51 2010 AlbertoUpdateIOOMC transmitted beam aligned to the Faraday; next things to doWe moved the MC-trans pick-off mirror (=
the beam splitter between the input of the
Faraday and the steering mirror located right
  
  3029   Wed Jun 2 01:47:28 2010 Alberto, KiwamuUpdateIOOmode measurement of new input opticsThe mode
profile of the new input optics was measured.
 afterMMT1.pngbeam_profile.pngMMT1_.dat.zipinside_vac_2.png 
  3031   Wed Jun 2 03:50:03 2010 KojiUpdateIOOmode measurement of new input opticsJust note that MMT1 has RoC of -5m (negative!).
This means that it is a lens with f=-2.5
m,
  
  3043   Thu Jun 3 13:14:27 2010 kiwamuUpdateIOOmode measurement of new input opticsI corrected the sketch of the new IOO. 
The sketch in the last entry was
also replaced by the new one. 
 inside_vac_2.png 
  3044   Thu Jun 3 14:01:51 2010 kiwamuUpdateIOOmode measurement of new input opticsI checked
the measured data of the mode profile which
 check_measurement_edit.png 
  3045   Thu Jun 3 14:13:20 2010 JenneUpdateIOOmode measurement of new input optics


   
        
            
  
  3046   Thu Jun 3 14:40:28 2010 Alberto, KiwamuUpdateIOOmode measurement of new input optics


   
        
            
  
  3049   Fri Jun 4 11:32:51 2010 Alberto, kiwamuUpdateIOOMC MMT1 Mirror Tests[Alberto, Kiwamu]
Last Wednesday,
we measured the beam profile after the MC
mode matching telescope n.1 (MMT1). We found
 MCMMT1spareOpticsTestSetup.png 
  3054   Tue Jun 8 00:38:22 2010 Koji, KiwamuUpdateIOOimproved Gaussian beam in new IOOThe shape
of the beam spot in the new input optics
 2010-6-7_2.png 
  3068   Fri Jun 11 14:31:04 2010 kiwamuUpdateIOOmode matching of new IOOWe decided not to care about the mode
after MMT1.
 profile_MMT.pngdist_MMO.png 
  3076   Mon Jun 14 22:16:08 2010 JenneUpdateIOOMode scan after Mode Matching Telescope[Jenne, Kiwamu]
We measured the mode after the Mode
Matching Telescope. 
 after_MMT.png 
  3077   Tue Jun 15 16:28:32 2010 kiwamuUpdateIOOMode Profile after Mode Matching TelescopeWe obtained
a good mode match overlap of 99.0% for the
 newIOO_overlap_edit.png 
  3078   Tue Jun 15 19:24:25 2010 ranaUpdateIOOMode Profile after Mode Matching Telescope


   
        
            
  
  3088   Fri Jun 18 21:45:39 2010 kiwamuUpdateIOOMode Profile after Mode Matching Telescope (Round 2)    
      
 MMT20100618_edit.pngnewIOO_overlap_edit.png 
  3089   Fri Jun 18 22:12:29 2010 AlbertoUpdateIOOMode Profile after Mode Matching Telescope (Round 2)GJ   
  3117   Thu Jun 24 18:47:26 2010 FrankDAQIOOVME crate rebooted we had
to reboot
the IOO VME crate right before lunch
  
  3151   Wed Jun 30 23:03:46 2010 ranaConfigurationIOOPower into MC restored to maxKiwamu, Nancy, and I restored the power
into the MC today:

    Changed the 2" dia.
  
  3173   Wed Jul 7 22:52:38 2010 rana, nancyConfigurationIOObad length control offset for the MCRana found out that a connection was bad
in the shown place, due to which the MEDM
screen was showing bad offset for length
 P7070251.jpgScreenshot.png 
  3174   Wed Jul 7 22:58:08 2010 nancyUpdateIOOMC alignment values.Nancy and Koji:
This is what I and Koji measured
after aligning the MC in the afternoon.
  
  3175   Wed Jul 7 23:11:08 2010 KojiUpdateIOOMC alignment values.Hmm. I expect that you will put more details
of the work tomorrow.
i.e. motivation, method, result (the
  
  3182   Thu Jul 8 19:43:16 2010 nancyUpdateIOOWFS calculationsThe WFS error signals were recorded in
the order 
WFS1_PIT
  
  3183   Thu Jul 8 20:32:22 2010 nancyUpdateIOOMC alignment values.I and Koji were trying to lock the mode
cleaner for measuring the  beam power at
MC2 end. That is when we obtained the trans
  
ELOG V3.1.3-