14995
|
Mon Oct 28 23:20:11 2019 |
gautam | Update | ALS | ALS power budget |
IR ALS power budget
Photodiode |
PSL VDC [V] |
PSL IDC [uA] |
AUX VDC [V] |
AUX IDC [uA] |
IRF [mA pk] |
PRF [dBm] |
PSL+EX |
3 |
300 |
2.5 |
250 |
~600 |
~3 |
PSL+EY |
3 |
300 |
0.6 |
60 |
~270 |
~ -3 |
In calculating the above numbers, I assumed a DC transimpedance of 10 khhms and an RF Transimpedance of ~800 V/A.
[Elog14480]: per these calculations, with the NewFocus 1611 PDs, we cannot achieve shot noise limited sensing for any power below the rated maximum for linear operation (i.e. 1mW). Moreover, the noise figure of the RF amplifier we use to amplify the sensed beat note before driving the delay-line frequency discriminator is unlikely to be the limiting noise source in the current configuration. Rana suggested that we get two Gain Blocks. These can handle input powers up to ~10dBm while still giving us plenty of power to drive the delay line. This way, we can (i) not compromise on the sacred optical gain, (ii) be well below the 1dB compression point (i.e. avoid nonlinear noise effects) and (iii) achieve a better frequency discriminant.
Temporary fix: While the gain blocks arrive, I inserted a 10dB (3dB) attenuator between the PSL+EX (PSL+EY) photodiode RF output and the ZHL-3A amplifiers. This way, we are well below the 1dB compression point of said RF amplifiers, and also below the 1dB compression point of the on-board Teledyne AP1053 amplifiers on the demodulator boards we use.
Nest steps: Rana is getting in touch with Rich Abbott to find out if there is any data available on the noise performance of the post-mixer IF amplifier stage in the 0.1 -30 Hz range, where the voltage and current noise of the AD829 OpAmps could be limiting the DFD performance. But in the meantime, the ALS noise seems good again, and there is no evidence of the sort of CARM/DARM coupling that motivated this investigation in the first place. Managed to execute several IR-->ALS transitions tonight in the PRFPMI locking efforts (next elog).
No new Teledyne AP1053s were harmed in this process - I'll send the 5 units back to Rich tomorrow. |
11378
|
Thu Jun 25 18:20:15 2015 |
ericq | Update | LSC | ALS reconstruction in progress | I've been working on getting a working ALS up and running. Things are in a bit of a transient state right now; I'm off to softball and dinner, and will resume work tonight. There will be a more detailed ELOG then, but here are some quick notes:
- c1als has been gutted, phase trackers are working successfully in c1lsc frontend. All channel names remain the same.
- BEATX is on the ADC channels where AS165 used to live, BEATY at POP55.
- Used a marconi to drive the aLIGO LSC demod board in the LSC rack, was able to lock digital phase tracker on two channels
- Noise looks pretty cruddy. Lots of 60Hz harmonics on both channels, maybe from marconi drive? Pickup in the delay line?
- BEATX whitening filter maybe has something fishy going on; excess noise at 2kHz
- Unclear if BEATY whitening filter is actually doing anything.
- Whitening gain switching works fine for both, though. Haven't revisited the switching code, so its controlled in the old RFPD place for now.
- Whitening triggering is not set up, will require some thought and model work that isn't neccesary yet.
- Agilent analyzer, marconi, and old delay lines are currently stashed behind the LSC rack; I will resume work with them tonight.
The main thing left to do is to install the RF amplifiers at the PSL table and route the green beat signals over to the LSC rack. I fear that some investigation into the whitening filters will be neccesary to make the performance adequate, however. |
11379
|
Fri Jun 26 03:24:18 2015 |
ericq | Update | LSC | ALS reconstruction in progress | Too sleepy to make full ELOG. Stay tuned.
Two 25dB amplifiers (with fins!) are living in the top shelf on the PSL table, inputs currently grounded. I broke out the fused 24V power from the AOM driver to power the two amps and the AOM driver. I used the POP55 and AS165 heliax cables to get their outputs to the LSC rack, through delay lines, into demod board.
Driving with -20dBm at 55MHz, the BEATX signal chain has about 60Hz RMS noise, which is about what I measured for driving the old beatbox with a marconi. High frequency noise is a much nicer shape, though. The BEATY signal didn't seem to be getting through, will double check soon.
Still old delay cables, not nicely shielded or isolated or anything. We'll have to pipe the monitor signal from the LSC rack over to the control room analyzer now.
|
11381
|
Mon Jun 29 12:28:45 2015 |
ericq | Update | LSC | ALS reconstruction in progress | Turns out the reason that the BEATY signal wasn't working is that one of the two RF amplifiers (both of which are model ZHL-32A), isn't amplifying. Voltage at the pins is fine, so maybe its just broken. When the ZHL-3As that Rana ordered arrive, I'll install those.
Switching the working amplifier between the two channels, and using a Marconi driving -20dBm (the Y green beatnote amplitude), the phase tracker output RMSs are 70Hz and 150Hz for X and Y, respectively, which isn't too exciting. There is enough whitening gain and filtering that I don't think ADC noise is an issue (The magnitude of the phase tracker Q is ~10kcounts after +6dB whitening gain).
The RMS in both channels mostly comes from a whole mess of 60Hz harmonics. I'll see what I can do by taking better care of the delay line cables, but it is kind of weird that this would be worse now, given that there was little care given to them before either.
Also, for now, so I don't have to lug the marconi around everywhere, I'm currently driving both channels of the demod board with a spare 55MHz LO output of the LSC LO distribution box, which ends up being a factor of 5 smaller phase tracker error signal, but the noise level is about the same as with the marconi. |
12578
|
Mon Oct 24 11:39:13 2016 |
gautam | Update | General | ALS recovered | I worked on recovering ALS today. Alignments had drifted sufficiently that I had to to the alignment on the PSL table onto the green beat PDs for both arms. As things stand, both green (and IR) beats have been acquired, and the noise performance looks satisfactory (see Attachment #1), except that the X beat noise above 100Hz looks slightly high. I measured the OLTF of the X end green PDH loop (after having maximized the arm transmission, dither alignment etc, measurement done at error point with an excitation amplitude of 25mV), and adjusted the gain such that the UGF is ~10kHz (see Attachment #2). |
13180
|
Wed Aug 9 19:21:18 2017 |
gautam | Update | ALS | ALS recovery | Summary:
Between frequent MC1 excursions, I worked on ALS recovery today. Attachment #1 shows the out-of-loop ALS noise as of today evening (taken with arms locked to IR) - I have yet to check loop shapes of the ALS servos, looks like there is some tuning to be done.
On the PSL table:
- First, I locked the arms to IR, ran the dither alignment servos to maximize transmission.
- I used the IR beat PDs to make sure a beat existed, at approximately.
- Then I used a scope to monitor the green beat, and tweaked steering mirror alignment until the beat amplitude was maximized. I was able to improve the X arm beat amplitude, which Koji and Naomi had tweaked last week, by ~factor of 2, and Y arm by ~factor of 10.
- I used the DC outputs of the BBPDs to center the beam onto the PD.
- Currently, the beat notes have amplitudes of ~-40dBm on the scopes in the control room (there are various couplers/amplifiers in the path so I am not sure what beatnote amplitude this translates to at the BBPD output). I have yet to do a thorough power budget, but I have in my mind that they used to be ~-30dBm. To be investigated.
- Removed the fiber beat PD 1U chassis unit from the PSL table for further work. The fibers have been capped and remain on the PSL table. Cleaned the NW corner of the PSL table up a bit.
To do:
- Optimization of the input pointing of the green beam for X (with PZTs) and Y (manual) arms.
- ALS PDH servo loop measurement. Attachment #1 suggests some loop gain adjustment is required for both arms (although the hump centered around ~70Hz seem to be coming from the IR lock).
- Power budgeting on the PSL table to compare to previous such efforts.
Note: Some of the ALS scripts are suffering from the recent inablilty of cdsutils to pull up testpoints (e.g. the script that is used to set the UGFs of the phase tracker servo). The workaround is to use DTT to open the test points first (just grab 0.1s time series for all channels of interest). Then the cdsutils scripts can read the required channels (but you have to keep the DTT open). |
13519
|
Tue Jan 9 21:38:00 2018 |
gautam | Update | ALS | ALS recovery |
- Aligned IFO to IR.
- Ran dither alignment to maximize arm transmission.
- Centered Oplev reflections onto their respective QPDs for ITMs, ETMs and BS, as DC alignment reference. Also updated all the DC alignment save/restore files with current alignment.
- Undid the first 5 bullets of elog13325. The AUX laser power monitor PD remains to be re-installed and re-integrated with the DAQ.
- I stupidly did not refer to my previous elog of the changes made to the X end table, and so spent ages trying to convince Johannes that the X end green alignment had shifted, and turned out that the green locking wasn't going because of the 50ohm terminator added to the X end NPRO PZT input. I am sorry for the hours wasted

- GTRY and GTRX at levels I am used to seeing (i.e. ~0.25 and ~0.5) now. I tweaked input pointing of green and also movable MM lenses at both ends to try and maximize this.
- Input green power into X arm after re-adjusting previously rotated HWP to ~100 degrees on the dial is ~2.2mW. Seems consistent with what I reported here.
- Adjusted both GTR cameras on the PSL table to have the spots roughly centered on the monitors.
Will update shortly with measured OLTFs for both end PDH loops.
- X end PDH seems to have UGF ~9kHz, Y end has ~4.5kHz. Phase margin ~60 degrees in both cases. Data + plotting code attached. During the measurement, GTRY ~0.22, GTRX~0.45.
Next, I will work on commissioning the BEAT MOUTH for ALS beat generation.
Note: In the ~40mins that I've been typing out these elogs, the IR lock has been stable for both the X and Y arms. But the X green has dropped lock twice, and the Y green has been fluctuating rather more, but has mangaged to stay locked. I think the low frequency Y-arm GTRY fluctuations are correlated with the arm cavity alignment drifting around. But the frequent X arm green lock dropouts - not sure what's up with that. Need to look at IR arm control signals and ALS signals at lock drop times to see if there is some info there. |
9122
|
Wed Sep 11 17:35:38 2013 |
Jenne | Update | LSC | ALS requirement | I have done a quickie look at Optickle to see how the linewidth of an arm cavity changes versus the configuration.
To do this, I make different configurations, and do a sweep of ETMX. For each configuration, I find the max peak value, and then find the points that are at half that value. The distance between them is the full width at half max.
I get:
FWHM_DRFPMI = 3.8750e-11 meters
FWHM_PRFPMI = 3.8000e-11 meters
FWHM_SRFPMI = 2.3200e-09 meters
FWHM_FPMI = 1.1900e-09 meters
So, for the ALS to hold within 1/10th of a linewidth for the full IFO configuration, we want the ALS noise to be on the order of 3 picometers RMS. If I recall correctly, that's about an order of magnitude better than we currently have.

use LOG y-scale
EDIT 8 Nov 2013, JCD: New log-y plot:

|
14846
|
Thu Aug 15 18:54:54 2019 |
gautam | Update | ALS | ALS sensing noise due to IMC | Summary:
I came aross an interesting suggestion by Yutaro that KAGRA's low-frequency ALS noise could be limited by the fact that the IMC comes between the point where the frequencies of the PSL and AUX lasers are sensed (i.e. the ALS beat note), and the point where we want them to be equal (i.e. the input of the arm cavity). I wanted to see if the same effect could be at play in the 40m ALS system. A first estimate suggests to me that the numbers are definitely in the ballpark. If this is true, we may benefit from lower noise ALS by picking off the PSL beam for the ALS beat note after the IMC.
Details:
Even though the KAGRA phase lock scheme is different from the 40m scheme, the algebra holds. I needed an estimate of how much the arm cavity moves, I used data from a POX lock to estimate this. The estimate is probably not very accurate (since the arm cavity length is more stable than the IMC length, and the measured ALS noise, e.g. this elog, is actually better than what this calculation would have me believe), but should be the right order of magnitude. From this crude estimate, it does look like for f<10 Hz, this effect could be significant. I assumed an IMC pole of 3.8 kHz for this calculation.
I've indicated a "target" ALS performance where the ALS noise would be less than the CARM linewidth, which would hopefully make the locking much easier. Seems like realizing this target will be touch-and-go. But if we can implement length feedforward control for the arm cavities using seismometers, the low frequency motion of the optics should go down. It would be interesting to see if the ALS noise gets better at low frequencies with length feedforward engaged.
* Some updates were made to the plot:
- Took data from Kiwamu's paper for the seismic noise
- Overlaid measured ALS noise
|
14847
|
Fri Aug 16 04:24:03 2019 |
rana | Update | ALS | ALS sensing noise due to IMC | What about just use high gain feedback to MC2 below 20 Hz for the IMC lock? That would reduce the excess if this theory is correct. |
8841
|
Fri Jul 12 23:13:32 2013 |
manasa | Update | Green Locking | ALS sensor noise | [Annalisa, Koji, Manasa]
In order to improve the ALS stability we went ahead to check if we are limited by the sensor noise of ALS.
What we did:
RF signals similar to the beatnote were given at the RF inputs of the beatbox.
The frequency of the RF signal was set such that I_OUT was zero (zero-crossing point of the beatbox).
We measured the noise spectrum of the phase tracker output.
Measurements:
Plot 1: X ALS noise spectrum
Plot 2: Y ALS noise spectrum
Discussion:
The X arm ALS noise is not limited by the sensor noise...which means we shoudl come up with clever ideas to hunt for other noise sources.
But this does not seem to be the case for the Y arm ALS. The Y arm part of the beatbox is noisy for frequencies < 100Hz.
After looking into the details and comparing the X and Y arm parts of beatbox, it looks that amplitude of the beat signal seem to affect the Y arm ALS noise significantly and changes the noise spectrum.
To do:
Investigate the effect/limitations of amplitude of the beatnote on the X arm and Y arm beatbox.
|
9171
|
Fri Sep 27 20:28:10 2013 |
manasa | Update | Green Locking | ALS servo | [Masayuki, Manasa]
I. ALS servo loops
After fixing things with the phase tracking loop, we checked if things were good with the ALS servo loops.
We measured the OLTF of the X and Y arm ALS servo loops. In both cases the phase margin was ~20 degrees. There was no room to set enough phase margin. So we looked at the servo filters. We tried to modify the filters so that we could bring enough phase margin, but could not get at it. So we put back the old filters as they were.
attachment1: OLTF of the ALS XARM and YARM control loops
attachment2: Current phase budget. FM4 and FM10 are the boost filters.
II. ALS in-loop noise
Also, I found that the overall noise of the ALS servo has gone up by about two orders of magnitude (in Hz/rtHz) over the whole range of frequencies for both the arms from the last time the measurements were made. I suspect this could be from some change in the calibration factor. Did anybody touch things around that could have caused this? Or can somebody recollect any changes that I made in the past which might have affected the calibration? Anyways, I will do the calibration again.
|
9861
|
Sun Apr 27 21:30:59 2014 |
Koji | Update | LSC | ALS servo characterization | The measured openloop TF of the ALS servo for each was characterized by a ZPK model.
The openloop TF can be modeled by:
1) Filter TF obtained from foton
2) Actuator response with appropriate assumption
3) Phase tracker closed loop TF
4) Delay caused by the digital control
5) anything else
For 1) ZPK models of the servo filter was obtained from foton. It turned out that the TF of FM5 doesn't match with the ZPK model in foton.
Therefore the TF was exported and fitted with LISO. This seems to be related to the pole frequency (3kHz) which is too close to Nyquist frequency (8kHz).
FM(:,1) = zero1(f,5).*pole1(f,0.001)*5000;
FM(:,2) = zero1(f,1).*pole1(f,0.001)*1000;
FM(:,3) = zero2(f,4.5,1.4619).*pole1(f,0.001).*pole1(f,0.001)*20.2501*1e6;
FM(:,4) = zero2(f,35,2).*pole2(f,3,3).*zero1(f,3000).*pole1(f,1).*pole2(f,3000,1/sqrt(2)).*pole1(f,700).*zero1(f,10).*zero1(f,350).*136e1;
FM(:,5) = zero1(f,1).*pole1(f,4.010e3).*pole2(f,17.3211e3,1.242).*zero2(f,18.865e3,100e3);
FM(:,6) = zero2(f,3.2,0.966775).*pole2(f,3.2,30.572);
FM(:,7) = zero2(f,16.5,2.48494).*pole2(f,16.5,78.5807).*zero2(f,24.0,2.22483).*pole2(f,24.0,7.03551);
FM(:,8) = 1;
FM(:,9) = zero2(f,7.50359,1.07194).*pole2(f,1.43429,0.717146)*27.5653;
FM(:,10) = 1;
dc_gain = 14;
FM1/2/3/5/6/7/9 are used for the control.
For 2), a resonant freq of 0.97 with Q of 5 was assumed.
The model for 3) was obtained by the previous entry.
Now the measured TF was divided by the known part of the model 1) ~ 3) and empirically fitted in LISO.
### XARM ###
pole 392.5021429051 698.1992431753m
zero 42.3128869460k 31.0954443799m
pole 589.2716424428 2.8325268375
factor 8.3430140244
delay 34.7536691023p
### YARM ###
pole 416.2463334253 743.2196174175m
zero 97.9161062704M 114.6703921876m
pole 626.0463515310 2.7671041771
factor 9.0045911761
delay 34.0945727358p
These compensation TF have weird TF. Probably the frequency response of the delay and the analog AA/AI filters without the high frequency data
led the LISO make up this. I'm requesting Masayuki to provide the AA/AI data to make the estimation more reasonable.
For the servo modeling, this is sufficient and we'll go a head.
The results of the OLTF modeling are attached. |
8792
|
Wed Jul 3 01:49:46 2013 |
Annalisa | Update | Green Locking | ALS servo configuration | [Koji, Annalisa, Manasa]
Today we worked on the ALS servo stabilization for the Y arm.
First step: find the beat note
The beat note was found following the usual steps:
- Y arm cavity locked on IR to have a good alignment
- Y arm cavity locked on green (eventually unlocked on IR)
- beat note alignment maximized on the PSL table
Beat note amplitude = -27 dBm @ 50 MHz
PSL temperature = 31.54 degC
Laser Offset on the slow servo2 = -11011
In the GREEN HORNET we did the following changes for the Y arm:
Input Signal Conditioning
On the C1ALS-BEATY_FINE screen the same antiwhitening filters of the C1ALS-BEATX_FINE have been reproduced. At moment, only the FM3 [10:1] is enabled.
On the C1ALS-BEATY_FINE_PHASE screen the gain was set at 3600, since the amplitude of the Q signal after the Phase rotator (BEATY_FINE_Q_ERR) was about 30. To set this value we made a proportion with respect to a previous optimized value, where the amplitude was 100 and the gain was set to 1200.
DOF filters
In order to stabilize the beat frequency, we started enabling the FM5 [1000:1] filter in the C1ALS_YARM panel, and then we started increasing the gain first in small steps (0.1), in order to understand which sign the gain should have without kicking the mirror.
We measured the Power Spectrum of the C1:ALS-BEATY_FINE_PHASE_OUT in-loop signal while varying the gain of the C1ALS_YARM servo filter.
Eventually, we enabled the following filters:
FM2 [0:1]
FM3 [1:5]
FM4 [1:50]
FM5 [1000:1]
FM6 [RG3.2]
FM7 [RG16.5]
Gain = -30.
Koji expects the UGF of the loop to be around 100-ish Hz, and he also expected the small bump around 300-400 Hz.
Then we realized that the channel we were measuring was not calibrated in unit of Hz, so we took again the measurement looking at the channel C1:ALS-BEATY_FINE_PHASE_OUT_HZ. In this case, we didn't observe any bump. Maybe the beat frequency was slightly changed from the previous measurement and the all servo shape was also different. The final value of the gain was set at -8.
The Y axis unit is missing (bad me!). It's in deg/sqrt(Hz) for the first plot and Hz/sqrt(Hz) for the second one.
|
8793
|
Wed Jul 3 03:06:29 2013 |
Annalisa | Update | Green Locking | ALS servo configuration |
I realized that I cannot open the attached plots. I'll fix them tomorrow. |
9183
|
Tue Oct 1 17:14:53 2013 |
masayuki | Update | Green Locking | ALS servo filters modified |
[Manasa, Masayuki]
[revised at 10/1 pm 5:00]
As we mentioned in previous entry (elog#9171), the phase margin of ALS control was at most 20 degree. We modified the filter of C1ALS_XARM and C1ALS_YARM. The OLTF is in attachment1. Now the phase margins of both arms are more than 35 degree. I modified the FM5 filters of both servo.
FM5 filter is the filter for the phase compensation. It had the one pole at 1000 Hz and one zero at 1Hz. As you can see in attachment2, it start to lose the phase at 50 Hz. But the UGF of our ALS control loop is higher than 100 Hz, so I changed the pole from 1 kHz to 3 kHz in order to get more phase margin at UGF. The new servo have 10dB larger gain than previous filter at higer than 1kHz, but the control loop do nothing in that region, so it's no problem.
We have phase lag between 2 arms. I used same filters for both arms, so I'm wondering where these phase lag came from.
|
13595
|
Wed Jan 31 22:32:11 2018 |
gautam | Update | ALS | ALS signal chain + power budget | Summary:
I do not have an answer to the question "What is an appropriate gain for the IF amplifier stage in the D0902745 FET demod boards?", because of the following problems.
Deatils:
The plan is to lower the gain of the IF amplifier stage on the FET demodulator board from 100 to 10. As per Attachment #1, this will make the overall gain from RF beatnote from the Beat Mouth to the signal input to the D990694 whitening board +19dB, assuming "typical" values for the conversion loss of the mixer, and the various other passive components on the FET demod board. I've used numbers I measured a couple of weeks ago for the delay line loss and the cabling loss from the PSL table to the LSC rack. This in turn will set a limit on how much RF beat power we can handle, from the Beat Mouth. According to this power budget, if we have -5dBm of beat, we will have an input to the whitening board of ~6Vpp, which is about half its full range. The trouble is, I don't know what the transimpedance gain of the Fiber Beat PDs are. The datasheet suggests a "maximum gain" of 5e4 V/W, which presumably takes into account the InGaAs responsivity and the actual transimpedance gain. However, according to the last power budget I did inside the Beat Mouth, I had -8dBm of beat for a combined 400uW of PSL+EX light, which definitely does not add up. I've emailed the company to ask about the spec, haven't gotten anything useful yet...
The problem is further complicated by the fact that the fiber inside the Beat Mouth is NOT polarization maintaining, and so the actual relative polarizations of the arm IR light and the PSL IR light is unpredictable, and also uncontrolled. I suppose we could simply place a HWP before the fiber collimator at either end, and rotate the polarization until we get a desired amount of beat, but this still does not solve the problem of the polarization being uncontrolled.
I am going to characterize the demod board using E1100114. I am unsure as to the conversion loss of the mixer - the datasheet suggested a number of 8dB, but T1000044 suggests that the conversion loss is actually only 4dB. I figure it's best to just measure it. Would also be good to verify that the overall transfer function and noise of the IF amplifier stage match my expectation from the LISO model.
Option #1: Rana ordered 50ohm and 500ohm SMD resistors of the 0805 package size, I asked Steve to get a few more values just in case we want to twiddle with the gain of this stage further (specifically, I asked for values such that we can set it to x5, x3 and x1). But changing the feedback resistors modifies the overall TF shape - see e.g. Attachment #2. Need to also look at how the noise performance varies.
Another possibility is to turn down the gain of the IF amplifier stage to x10, retire the ZHL-3A, and use a lower gain amplifier in its place. We do have the recently acquired Teledyne amplifiers, but we would have to package it in such a way that it can be integrated into the existing Fiber ALS signal chain. This would allow us to handle significantly larger RF beatnote powers, which I expect we will have if we improve the mode matching into the fibers (provided the aforementioned polarization drift possibility doesn't hurt us too much).
A third possibility is to attenuate the power coupled into the fibers to lower the RF beatnote amplitude. I don't like this option so much because placing an ND filter or a PBS+HWP combo in the beam path is likely to screw up the mode-matching into the fiber collimator, which I have already spent so many hours trying to improve, but if it must be done, it must be done.
The correct option is of course the one that gives us the lowest ALS noise. It is not clear to me which one that is at this point. |
13597
|
Thu Feb 1 15:31:12 2018 |
gautam | Update | ALS | ALS signal chain + power budget | Summary:
A reasonable level of RF beatnote power for operating within the specs of the demod board is 17dBm arriving at the input to the power splitter just before the delay line.
Details:
Stuff is beginning to look clearer now that I've done some initial characterization of the demod boards. I will upload a more detailed report of the characterization on the DCC page, but important findings are:
- The overall conversion factor from RF to IF is ~2.3V IF per volt of RF.
- 50ohm source connected to RF input of demod board, level = 10dBm on Marconi screen, consistent with inferred value from RF mon output.
- LO driven at 14dBm by Fluke function generator.
- The ratio was calculated for IF voltage input into a High-Z load.
- So let's say we want to run at half the ADC full range of 10Vpp into the whitening board - this means we need to keep the RF input to <=11dBm.
- The Teledyne amplifier has a rated maximum input voltage of 17dBm. If we want to stay 3dB below this, we can send in 14dBm into the LO input of the demod board, which is what my characterizations were done with.
The delay line has a loss of ~3dB. The power splitter has a loss of 3dB. So putting everything together, 17dBm at the input of the power splitter gives us just the right amount of RF power to have the LO input driven at 14dBm, and the IF output be ~5Vpp into a High-Z load, which is about half the ADC full range.
|
13613
|
Wed Feb 7 10:16:26 2018 |
gautam | Update | ALS | ALS signal chain + power budget | After emailing the technical team at Menlo, I have uploaded the more detailed information they have given me on our wiki.
Quote: |
The trouble is, I don't know what the transimpedance gain of the Fiber Beat PDs are. The datasheet suggests a "maximum gain" of 5e4 V/W, which presumably takes into account the InGaAs responsivity and the actual transimpedance gain.
|
|
13600
|
Fri Feb 2 13:16:55 2018 |
gautam | Update | ALS | ALS signals whitening switching | While setting up for this measurement, I noticed something odd with the whitening switching for the ALS channels. For the usual LSC channels, the whitening is set up such that switching FM1 on the MEDM screen changes a BIO bit which then enables/disables the analog whitening stage. But this feature doesn't seem to be working for the ALS channels - I terminated all 4 channels at the LSC rack, and measured the spectrum of the IN1 signals with DTT in the two settings, such that I expect to see a difference in the spectra if the whitening is enabled or disabled - FM1 enabled (expected analog whitening to be engaged) and FM1 disabled (expected analog whitening to be bypassed). But I see no difference in the spectra. I confirmed that the BIO bit switching is happening at least on the software level (i.e. the bit indicator MEDM screens indicate state toggling when FM1 is ON/OFF). But I don't know if something is amiss in the signal chain, especially since we are using Hardware channels that were previously used for AS_165 and POP_55 signals.
Is the whitening shape such that we expect the terminated noise level to be below ADC Noise even when the whitening is engaged? I just checked the shape of the de-whitening filter, and it has -40dB gain above 150Hz, so the inverse shape should have +40dB gain.
Quote: |
I will now proceed to the next piece (#3?) of this puzzle, which is to understand how the D990694 which receives the signals from this unit reacts to the expected DC voltage level of ~4Vpp
|
gautam 2.15pm: This was a FALSE ALARM, with the inputs terminated, the electronics noise really is that low such that it is buried under ADC noise even with +40dB gain. I cranked up the flat whitening gain from 0dB to 45dB for the X channels (but left the Y channels at 0dB). Attachment #2 is the comparison. Looks like the switching works just fine. |
10302
|
Thu Jul 31 01:08:54 2014 |
Koji | Update | LSC | ALS stability check | - ALS X/Y arm stability was checked by IR locked arms.
- Basically the stability looks same as before.
Q sez: here are some ALS ASDs (in Hz/rtHz).
The reference plots are with the arms locked on CARM/DARM with ALS. The main traces are with the arms locked on POX/POY. Alignment affects these traces a fair amount.

The X arm ALS seems no worse for the upgrade, and the PZT actuators do look pretty orthogonal when we play around with the alignment. |
14486
|
Mon Mar 18 20:22:28 2019 |
gautam | Update | ALS | ALS stability test | I'm running a test to see how stable the EX green lock is. For this purpose, I've left the slow temperature tuning servo on (there is a 100 count limiter enabled, so nothing crazy should happen). |
9228
|
Wed Oct 9 22:58:34 2013 |
Manasa | Update | Green Locking | ALS stabilization | After Jenne and Masayuki told that they were not able to stabilize the ALS for either arms yesterday, I looked into things with the ALS servo.
I had trouble initially trying to even stabilize the loop for a few minutes. So I measured the OLTF of the phase tracker loop and the ALS X arm servo. I changed phase tracker gain to 125 and that rendered UGF of 2KHz and phase margin of 45 degrees for the phase tracker loop.
The ALS servo gain was set such that UGF was 125Hz and phase margin 38 degrees (attached is the transfer function measurement for the servo).
I could stabilize the arm to ~500 Hz/rtHz (rms), which is twice that of what we had while we did the (PRMI+1arm ALS).
But ALS was still not stable long enough with the higher rms to even allow a cavity scan to find IR resonance. I suspect the problem to now lie with the PDH loop. We should be looking to stabilize the PDH for green if we need a stable ALS. |
12105
|
Thu May 5 03:05:37 2016 |
gautam | Update | endtable upgrade | ALS status update | [ericQ, gautam]
Today we spent some time looking into the PDH situation at the X end. A summary of our findings.
- There is something that I don't understand with regards to the modulation signal being sent to the laser PZT via the sum+HPF pomona box - it used to be that with 2Vpp signal from the function generator, we got ~5mVpp signal at the PZT, which with the old specs resulted in a modulation of ~0.12rad. Now, however, I found that there was a need to place a 20dB attenuator after the splitter from the function generator in order to realize a modulation depth of ~0.25 (which is what we aim for, measured by locking to the TEM00 modes of the carrier and sidebands and comparing the ratio of powers). It could be that the PZT capacitance has changed dramatically after the repair. Nevertheless, I still cant reconcile the numbers. We measured the transfer function from the LO input of the pomona box to the output with the PZT connected, and figure there should be ~70dB of attentuation (with the 20dB additional attenuator in place). But this means 1Vpp*0.0003*70rad/V = 0.02rad which is an order of magnitude away from what the ratio of powers suggest. Maybe the measurement technique was not valid. In any case, this setup appears to work, and I'm also able to send +7dBm to the mixer which is what it wants (function generator output is 3Vpp).
- In addition to the above, I found that the demodulated error signal had a peak-to-peak of a few volts. But the PDH servo is designed to have tens of mV at the input. Hence, it was necessary to turn down the gain of the REFL PD to 10dB and add a 20dB attenuator between mixer output and servo input.
- While Johannes and I were investigating this earlier in the afternoon, we found that the waveform going to the laser PZT was weirdly distorted (still kind of sinusoidal in shape, but more rounded, I will put up a picture shortly). This may not be the biggest problem, but perhaps there is a better way to pipe the LO signal to the PZT and mixer than what is currently done.
- We then looked at loop transfer function and spectrum of the control signal. Plots to follow. They look okay.
- I measured the green power coming onto the PSL table. It is ~400uW. After optimizing alignment, the green transmission is ~0.4 according to whatever old normalization we are using.
- We then recovered the X green beatnote and looked at the ALS noise spectrum. Beatnote amplitude at the beat PD is ~ -27dBm. The coherence in the region of a few hundred Hz suggests that some improvements can be made to the PDH situation (the gain of the PDH servo is maxed out at the X end at the moment...). But the bottom line is this is probably good enough to get back to locking...
|
12108
|
Thu May 5 14:05:01 2016 |
rana | Update | endtable upgrade | ALS status update | All seems very fishy. Its not good to put attenuators and filters in nilly-willy.
- Once the post-PD bandpass has been designed and constructed, you should be able to use whatever PD gain setting gives you the best SNR. There's no need to use more PD gain than necessary; it just reduces the PD bandwidth. What is the input referred current noise of the PD at the different gain settings?
- The open loop mixer output *should* be very large. It should be reduced to mV only when the loop is closed.
- The better way to estimate the modulation depth is to lock the arm on red as usual and then scan the EX laser and look at the green transmission. The FSR is 3.7 MHz, so the SBs should show up well in a narrow scan around the carrier.
- I guess its going to be tough to impedance match the splitter box to the NPRO PZT, since its impedance is all over the place at 200-300 kHz, but you could put a 50 Ohm in-line terminator in there somewhere?
- The Bode plot seems to indicate that we could easily get a 10 kHz UGF and then switch on a Boost. Is the remote Boost switch disabled or always ON? I am suspicious of the plot and think that the coarse trace is probably missing some sharp resonances which will sneakily bite you.
|
11467
|
Thu Jul 30 14:27:18 2015 |
Eve | Update | Summary Pages | ALS, ASC, LSC Summary Pages | I've switches the ALS, ASC, and LSC plots on the summary pages from plotting raw frames, to plotting minute trends, instead. Now, the plots contain information, instead of being completely blank, but data is not recorded on the plots after 12UTC.
Typically, I make changes to the summary pages on my own version of the pages, found at https://ldas-jobs.ligo.caltech.edu/~eve.chase/summary/day/, where I change the summary pages for June 30 and then import such changes into the main summary pages.
|
8679
|
Wed Jun 5 14:43:42 2013 |
Annalisa | Update | LSC | ALS-TRY_OUT DQ channels |
Quote: |
After working some more on the EY table, we are getting some TEM00 flashes for the Y arm green. We have had to raise the height of one of the MM lenses to prevent clipping.
We used a function generator to apply a ~300 mV 10 Hz triangle wave to scan the laser frequency while aligning.
We tried to use the C1:ALS-TRY_OUT channel to help us in our alignment but there are a couple problems:
1) It seems that there is an uncompensated whitening filter before the ADC - Annalisa is making a compensation filter now.
2) The data delay is too much to use this for fast alignment. We might need to get a coax cable down there or mount a wired ethernet computer on the wall.
3) We need to make DQ channels for the TRY and TRX OUT. We need long term data of these, not just test points.
|
[Jenne, Annalisa]
DQ channels have been created in the C1ALS model for TRX and TRY. They are called TRX_OUT and TRY_OUT and the sampling rate is 2048 Hz. |
8667
|
Mon Jun 3 22:36:07 2013 |
rana | Update | LSC | ALS-TRY_OUT needs anti-whitening | After working some more on the EY table, we are getting some TEM00 flashes for the Y arm green. We have had to raise the height of one of the MM lenses to prevent clipping.
We used a function generator to apply a ~300 mV 10 Hz triangle wave to scan the laser frequency while aligning.
We tried to use the C1:ALS-TRY_OUT channel to help us in our alignment but there are a couple problems:
1) It seems that there is an uncompensated whitening filter before the ADC - Annalisa is making a compensation filter now.
2) The data delay is too much to use this for fast alignment. We might need to get a coax cable down there or mount a wired ethernet computer on the wall.
3) We need to make DQ channels for the TRY and TRX OUT. We need long term data of these, not just test points. |
8671
|
Tue Jun 4 16:04:34 2013 |
Annalisa | Update | LSC | ALS-TRY_OUT needs anti-whitening |
Quote: |
After working some more on the EY table, we are getting some TEM00 flashes for the Y arm green. We have had to raise the height of one of the MM lenses to prevent clipping.
We used a function generator to apply a ~300 mV 10 Hz triangle wave to scan the laser frequency while aligning.
We tried to use the C1:ALS-TRY_OUT channel to help us in our alignment but there are a couple problems:
1) It seems that there is an uncompensated whitening filter before the ADC - Annalisa is making a compensation filter now.
2) The data delay is too much to use this for fast alignment. We might need to get a coax cable down there or mount a wired ethernet computer on the wall.
3) We need to make DQ channels for the TRY and TRX OUT. We need long term data of these, not just test points.
|
I made the anti-whitening filter for the C1:ALS-TRY_OUT channel. But then I forgot to make an ELOG because I am bad. |
11334
|
Thu May 28 21:10:46 2015 |
Koji | Update | Green Locking | ALS-X noise hunting | I have been looking at the X-end ALS setup.
I was playing with the control bandwidth to see the effect to the phase tracker output (i.e. ALS err).
For this test the arm was locked with the IR and the green beat note was used as the monitor.
From the shape of the error signal, the UGF of the green PDH was ~10kHz. When I increased the gain
to make the servo peaky, actually the floor level of the ALS err became WORSE. I did not see any improvement
anywhere. So, high residual error RMS cause some broadband noise in the ALS??? This should be checked.
Then when the UGF was lowered to 3kHz, I could see some bump at 3kHz showed up in the ALS error.
I didn't see the change of the PSD below 1kHz. So, more supression of the green PDH does not help
to improve the ALS error?
Then, I started to play with the phase tracker. It seems that someone already added the LF booster
to the phase tracker servo. I checked the phase tracker error and confirmed it is well supressed.
Further integrator does not help to reduce the phase tracker error.
For the next thing I started to change the offset of the phase tracker. This actually changes
the ALS error level! The attached plot shows the dependence of the ALS error PSD on the phase tracker
output. At the time of this measurement, the offset of -10 exhibited the best noise level.
This was, indeed, factor of 3~5 improvement compared to the zero offset case below 100Hz.
I'm afraid that this offset changes the beat frequency as I had the best noise level at the offset of -5
with a different lock streatch. We should look at this more carefully. If the beat freq changes the offset,
this give us another reason to fix the beat frequency (i.e. we need the frequency control loop.
= Today's ALSX error would have not been the usual low noise state.
We should recover the nominal state of the ALS and make the same test = |
11931
|
Thu Jan 14 02:33:37 2016 |
ericq | Update | LSC | ALSX Noise still anomalously high | [ericq, Gautam]
We checked the UGF of the AUX X PDH servo, found a ~6kHz UGF with ~45 degree phase margin, with the gain dial maxed out at 10.0. Laser current is at 1.90, direct IR output is ~300mW.
We recovered ALS readout of IR-locked arms. While the GTRX seemed low, after touching up the beam alignment, the DFD was reporting a healthy amount of signal. ALSY was perfectly nominal.
ALSX was a good deal higher than usual. Furthermore, there's a weird shape around ~1kHz that I can't explain at this point. It's present in both the IR and green beats. I don't suspect the DFD electronics, because the Y beat came through fine. The peak has moderate coherence with the AUX X PDH error signal (0.5 or so), but the shape of the PDH error signal is mostly smooth in the band in which the phase tracker output is wonky, but a hint of the bump is present.
Turning the PDH loop gain down increases the power spectrum of the error signal, obviously, but also smoothens out the phase tracker output. The PDH error signal spectrum in the G=10 case via DTT is drowning in ADC noise a bit, so we grabbed it's spectrum with the SR785 (attachment #2, ASD in V/rtHz), to show the smoothness thereof.
Finally, we took the X PDH box to the Y end to see how ALSY would perform, to see if the box was to blame. Right off the bat, when examining the spectrum of error signal with the X box, we see many large peaks in the tens of kHz, which are not present at the same gain with the Y PDH box. Some opamp oscillation shenanigans may be afoot... BUUUUUT: when swapping the Y PDH box into the X PDH setup, the ~1kHz bump is identical. ugh

|
11937
|
Tue Jan 19 17:54:39 2016 |
gautam | Update | LSC | ALSX Noise still anomalously high | While carrying out my end-table power investigations, I decided to take a quick look at the out-of-loop ALSX noise - see the attached plot. The feature at ~1kHz seems less prominent (factor of 2?) now, though its still present, and the overall noise above a few tens of Hz is still much higher than the reference. The green transmission was maximized to ~0.19 before this spectrum was taken.
EDIT 1130pm:
We managed to access the trends for the green reflected and transmitted powers from a couple of months back when things were in their nominal state - see Attachment #2 for the situation then. For the X arm, the green reflected power has gone down from ~1300 counts (November 2015) to ~600 counts (january 2016) when locked to the arm and alignment is optimized. The corresponding numbers for the green transmitted powers (PSL + End Laser) are 0.47 (November 2015) and ~0.18 (January 2016). This seems to be a pretty dramatic change over just two months. For the Y-arm, the numbers are: ~3500 counts (Green REFL, Nov 2015), ~3500 counts (Green REFL, Jan 2016) ~1.3 (Green Trans, Nov 2015), ~1 (Green Trans, Jan 2016). So it definitely looks like something has changed dramatically with the X-end setup, while the Y-end seems consistent with what we had a couple of months ago... |
11803
|
Mon Nov 23 23:42:56 2015 |
ericq | Update | LSC | ALSY recovered | [ericq, gautam]
Gautam couldn't observe a Y green beatnote earlier, so we checked things out, fixed things up, and performance is back to nominal based on past references.
Things done:
- Marconi carrier output switched back on after Koji's excellent RF maintence
- BBPD power supplies switched on
- Removed a steering mirror from the green beatY path to do near/far field alignment.
- Aligned PSL / Y green beams
- Replaced mirror, centered beam on BBPD, moved GTRY camera to get the new spot.
- POY locked, dither aligned, beatnote found, checked ALS out-of-loop noise, found to be in good shape.
|
11804
|
Tue Nov 24 01:14:23 2015 |
Koji | Update | LSC | ALSY recovered | Sorry, I completely forgot to turn the Marconi on... |
7007
|
Mon Jul 23 18:41:15 2012 |
Jamie | Update | Green Locking | ALS_END.mdl model added for end station green ALS channels | The end sus models (c1scx and c1scy) both contain some ALS stuff. This stuff could maybe be moved to their own models, but whatever.
The stuff at X and Y were identical, but were code copies (BAD!). I made a new library part for the ALS end controls: ${userapps}/isc/c1/model/ALS_END.mdl
It contains just some filter modules for the ALS end laser control, and a monitor of the ALS end REFL PD DC. I also added a DQ block for the recorded channels (see screen shot).
When I added this new part to c1scx and c1scy I made it so the channel names would be more sensible. Instead of "GCX" and "GCY", they are now "ALS-X" and "ALS-Y". They will now all show up under the ALS subsystem.
|
7009
|
Mon Jul 23 19:00:26 2012 |
Koji | Update | Green Locking | ALS_END.mdl model added for end station green ALS channels | This is a good modification. We just need to check how the ALS scripts are affected.
Quote: |
The end sus models (c1scx and c1scy) both contain some ALS stuff. This stuff could maybe be moved to their own models, but whatever.
The stuff at X and Y were identical, but were code copies (BAD!). I made a new library part for the ALS end controls: ${userapps}/isc/c1/model/ALS_END.mdl
It contains just some filter modules for the ALS end laser control, and a monitor of the ALS end REFL PD DC. I also added a DQ block for the recorded channels (see screen shot).
When I added this new part to c1scx and c1scy I made it so the channel names would be more sensible. Instead of "GCX" and "GCY", they are now "ALS-X" and "ALS-Y". They will now all show up under the ALS subsystem.
|
|
5588
|
Fri Sep 30 17:40:03 2011 |
kiwamu | Update | IOO | AM / PM ratio | [Mirko / Kiwamu]
We have reviewed the AM issue and confirmed the ratio of AM vs. PM had been about 6 x103.
The ratio sounds reasonably big, but in reality we still have some amount of offsets in the LSC demod signals.
Next week, Mirko will estimate the effect from a mismatch in the MC absolute length and the modulation frequency.
(Details)
Please correct us if something is wrong in the calculations.
According to the measurement done by Keiko (#5502):
DC = 5.2 V
AM @ 11 and 55 MHz = - 56 dBm = 0.35 mV (in 50 Ohm system)
Therefore the intensity modulation is 0.35 mV / 5.2 V = 6.7 x 10-5
Since the AM index is half of the intensity modulation index, our AM index is now about 3.4 x 10-5
According to Mirko's OSA measurement, the PM index have been about 0.2.
As a result, PM/AM = 6 x 103
Quote from #5502 |
Measured values;
* DC power = 5.2V which is assumed to be 0.74mW according to the PDA255 manual.
*AM_f1 and AM_f2 power = -55.9 dBm = 2.5 * 10^(-9) W.
|
|
5606
|
Mon Oct 3 20:02:59 2011 |
Suresh | Update | PSL | AM / PM ratio | [Koji, Suresh]
In the previous measurement, the PDA 255 had most probably saturated at DC, since the maximum ouput voltage of PDA255 is 5V when it is driving a 50 Ohm load. It has a bandwidth of 0 to 50MHz and so can be reliably used to measure only the 11 MHz AM peak. In this band it has a conversion efficiency of 7000 V per Watt (optical power at 1064nm). [Conversion efficiency: From the data sheet we get 0.7 A/W of photo-current at 1064nm and 10^4 V/A of transimpedance] The transimpedance at 55 MHz is not given in the data sheet. Even if PDA255 is driving a high impedance load, at high incident power levels the bandwidth will be reduced due to finite gain x bandwidth product of the opamps involved, so the conversion efficiency at 11 MHz would not be equal to that at DC.
So Koji repeated the measurement with a lower incident light level:
**********************************
V_DC = 1.07 V with 50 Ohm termination on the multimeter.
Peak height at 11 MHz on the spectrum analyzer (50 Ohm input termination) = -48.54 dBm
***********************************
Calculation:
a) RF_Power at 11 MHz : -48.45 dBm = 1.4 x 10^(-8) W
b) RF_Power = [(V_rms)^2] / 50_ohm ==> V_rms = 8.4 x 10^(-4) V
c) Optical Power at 11 MHz: [V_rms / 7000] = 1.2 x 10^(-7) W
d) Optical Power at DC = [V_DC / 7000] = 1.46 x 10^(-4) W
e) Intensity ratio: I_AM / I_c = 7.9 x 10^(-4) . AM:Carrier amplitude ratio is half of the intensity ratio = 4.0 x 10^(-4)
f) PM amplitude ratio from Mirko's measurement is 0.2
g) The PM to AM amplitude ratio is 506
_________________________________
As the AM peak is highly dependent upon the drifting EOM position in yaw, it is quite likely that a higher PM/AM ratio could occur. But this measurement shows how small it could get if the current situation is allowed to continue.
Quote: |
[Mirko / Kiwamu]
We have reviewed the AM issue and confirmed the ratio of AM vs. PM had been about 6 x103.
The ratio sounds reasonably big, but in reality we still have some amount of offsets in the LSC demod signals.
Next week, Mirko will estimate the effect from a mismatch in the MC absolute length and the modulation frequency.
(Details)
Please correct us if something is wrong in the calculations.
According to the measurement done by Keiko (#5502):
DC = 5.2 V
AM @ 11 and 55 MHz = - 56 dBm = 0.35 mV (in 50 Ohm system)
Therefore the intensity modulation is 0.35 mV / 5.2 V = 6.7 x 10-5
Since the AM index is half of the intensity modulation index, our AM index is now about 3.4 x 10-5
According to Mirko's OSA measurement, the PM index have been about 0.2.
As a result, PM/AM = 6 x 103
Quote from #5502 |
Measured values;
* DC power = 5.2V which is assumed to be 0.74mW according to the PDA255 manual.
*AM_f1 and AM_f2 power = -55.9 dBm = 2.5 * 10^(-9) W.
|
|
|
5616
|
Tue Oct 4 16:58:45 2011 |
Suresh | Update | PSL | AM / PM ratio | Correction: Koji noted that Mirko actually reports a PM modulation index of 0.17 for the 11 MHz sideband (elog: http://nodus.ligo.caltech.edu:8080/40m/5462. This means
f) the amplitude ratio of the PM side-band to carrier is half of that = 0.084
g) the PM to AM amplitude ratio as 0.084 / [4.0 x 10^(-4)] = 209. |
15197
|
Fri Feb 7 09:45:03 2020 |
shruti | Update | General | AM at X end | I took a few AM TF measurements at the X end for which I:
- Misaligned the ITMX (then re-aligned it)
- Opened the X green shutter during the measurements and closed it at the end
- Moved the Agilent from the PSL area to the X end, the delay line and mixer still remains near the PSL area (will move it soon)
- Took a bunch of TFs
I will post the data soon. |
5249
|
Tue Aug 16 16:59:20 2011 |
Anamaria | Update | RF System | AM in the PM | Kiwamu, Keiko, Anamaria
Looking at the I and Q signals coming from REFL11 and REFL55 we saw large offsets, which would mean we have amplitude modulation, especially at 11MHz. We checked the PD themselves with RF spectrum analyzer, and at their frequencies we see stationary peaks (even if we look only at direct reflection from PRM). We changed the attenuation of the PSL EOM, and saw the peak go down. So first check is beam out of PSL EOM, to make sure the input beam is aligned to the crystal axis and is not giving AM modulation in adition to PM. |
15020
|
Thu Nov 7 17:46:10 2019 |
shruti | Update | ALS | AM measurement at X end | Some details:
- There was a SR560+SR785 (not connected for measurement) placed near the X end which I moved; it is now behind the electronics rack by the X arm beam tube (~15m away).
- Also, for the AM measurement I moved the AG5395A from behind the PSL setup to the X end, where it now is.
- By toggling the XGREEN shutter, I noticed that the cavity was not resonant before I disconnected anything from the setup since the spot shape kept changing, but I proceeded anyway.
- Because Rana said that it was important for me to mention: the ~5 USD blue-yellow crocs (that I now use) work fine for me.
The AM Measurement:
1. The cables were calibrated with the DC block in the A port (for a A/R measurement)
2. The cable to the PZT was disconnected from the pomona box and connected to the RF out of the NA, the PD output labelled 'GREEN_REFL' was also disconnected and connected to the B port via a DC block.
3. The ITMX was 'misaligned'. (This allowed the reflected green PD output as seen on the oscilloscope to stabilize.)
4. The PZT is modulated in frequency and the residual amplitude modulation (as observed in the measured reflected green light) is plotted, ref. Attachment 1. The parameters for the plotted data in the attachment were:
# AG4395A Measurement - Timestamp: Nov 07 2019 - 17:04:07
#---------- Measurement Parameters ------------
# Start Frequency (Hz): 10000.0, 10000.0
# Stop Frequency (Hz): 10000000.0, 10000000.0
# Frequency Points: 801, 801
# Measurement Format: LOGM, PHAS
# Measuremed Input: AR, AR
#---------- Analyzer Settings ----------
# Number of Averages: 8
# Auto Bandwidth: On, On
# IF Bandwidth: 300.0, 300.0
# Input Attenuators (R,A,B): 0dB 10dB 20dB
# Excitation amplitude = -10.0dBm
------------------------------------
Update (19:13 7thNov19): When the ITMX was intentionally misaligned, Rana and I checked to see if the Oplevs were turned off and they were. But while I was casually checking the Oplevs again, they were on!
Not sure what to do about this or what caused it.
Quote: |
[Shruti, Rana]
- At the X end, we set up the network analyzer to begin measurement of the AM transfer function by actuation of the laser PZT.
- The lid of the PDH optics setup was removed to make some checks and then replaced.
- From the PDH servo electronics setup the 'GREEN_REFL' and 'TO AUX-X LASER PZT' cables were removed for the measurement and then re-attached after.
- The signal today was too low to make a real measurement of the AM transfer function, but the GPIB scripts and interfacing was tested.
|
|
14979
|
Fri Oct 18 20:21:33 2019 |
shruti | Update | ALS | AM measurement attempt at X end | [Shruti, Rana]
- At the X end, we set up the network analyzer to begin measurement of the AM transfer function by actuation of the laser PZT.
- The lid of the PDH optics setup was removed to make some checks and then replaced.
- From the PDH servo electronics setup the 'GREEN_REFL' and 'TO AUX-X LASER PZT' cables were removed for the measurement and then re-attached after.
- The signal today was too low to make a real measurement of the AM transfer function, but the GPIB scripts and interfacing was tested. |
3603
|
Thu Sep 23 23:24:43 2010 |
rana, johnny, tara | Summary | PSL | AM modulate AOM to measure RefCav Thermo-Optic coefficient | Big Johnny and I hacked a function generator output into the cross-connect of the 80 MHz VCO driver so that we could modulate the
amplitude of the light going into the RefCav. The goal of this is to measure the coefficient between cavity power fluctuations and the
apparent length fluctuations. This is to see if the thermo-optic noise in coatings behaves like we expect.
To do this we disconnected the wire #2 (white wire) at the cross-connect for the 9-pin D-sub which powers the VCO driver. This is
called VCOMODLEVEL (on the schematic and the screen). In the box, this modulates the gain in the homemade high power Amp which
sends the actual VCO signal to the AOM.
This signal is filtered inside the box by 2 poles at 34 Hz. I injected a sine wave of 3 Vpp into this input. The mean value was 4.6 V. The
RCTRANSPD = 0.83 Vdc. We measure a a peak there of 1.5 mVrms. To measure the frequency peak we look in
the FSS_FAST signal from the VME interface card. With a 10 mHz linewidth, there's no peak in the data above the background. This signal
is basically a direct measure of the signal going to the NPRO PZT, so the calibration is 1.1 MHz/V.
We expect a coefficient of ~20 Hz/uW (input power fluctuations). We have ~1 mW into the RC, so we might expect a ~20 Hz frequency shift.
That would be a peak-height of 20 uV. In fact, we get an upper limit of 10 uV.
Later, with more averaging, we get an upper limit of 1e-3 V/V which translates to 1e-3 * 1.1 MHz / 1 mW ~ 1 Hz/uW. This is substantially lower
than the numbers in most of the frequency stabilization papers. Perhaps, this cavity has a very low absorption? |
5763
|
Sat Oct 29 22:57:03 2011 |
Mirko | Update | LSC | AM modulation due to non-optimal SB frequency | [Kiwamu, Mirko]
Non-optimal 11MHz SB frequency causes PM to be transformed into AM.
m_AM / m_PM = 4039 * 1kHz / df , with df beeing the amount the SB freq. is off.
Someone might want to double check ths. |
5774
|
Tue Nov 1 13:41:38 2011 |
Mirko | Update | LSC | AM modulation due to non-optimal SB frequency |
Quote: |
[Kiwamu, Mirko]
Non-optimal 11MHz SB frequency causes PM to be transformed into AM.
m_AM / m_PM = 4039 * 1kHz / df , with df beeing the amount the SB freq. is off.
Someone might want to double check ths.
|
Actually there was an error.
For 11MHz it is:
m_AM / m_PM = 2228 * 1kHz / df
For 55MHz:
m_AM / m_PM = 99.80 * 1kHz / df
see PDF |
5503
|
Wed Sep 21 17:42:35 2011 |
rana | Update | IOO | AM modulation misery | I'd like to see some details about how to determine that the ratio of 1:50 is small enough for AM:PM.
* What have people achieved in past according to the elogs© of the measurements?
* What do we expect the effect of 1:50 to be? How much offset does this make in the MICH/PRC/SRC loops? How much offset is too much?
Recall that we are using frontal modulation with a rather small Schnupp Asymmetry...  |
5504
|
Wed Sep 21 18:53:03 2011 |
Keiko | Update | IOO | AM modulation misery | The signal offset due to the AM modulation is estimated by a simulation for PRCL for now. Please see the result below.
Too see how bad or good the AM modulation with 1/50 modulation depths of PM, I ran a simulation. For example I looked at PRCL sweep signal for each channel. I tried the three AM modulation depths, (1) m_AM=0 & m_PM = 0.17 (2) m_AM = 0.003 & m_PM = 0.17 which is the current modulation situation (3) m_AM = 0.17 & m_PM = 0.17 in which AM is the same modulation depth as PM. For the current status of (2), there are offsets on signals up to 0.002 while the maximum signal amplitude is 0.15. I can't tell how bad it is.... Any suggestions?
(1) m_AM=0 & m_PM = 0.17. There is no offset in the signals.

(2) m_AM = 0.003 & m_PM = 0.17. There are offsets on signals up to 0.002 while the maximum signal amplitude is 0.15.

(3) m_AM = 0.17 & m_PM = 0.17. There are offsets on signals up to 0.1 while the maximum signal amplitude is 0.2.

I will look at MICH and SRCL in the same way.
Quote: |
I'd like to see some details about how to determine that the ratio of 1:50 is small enough for AM:PM.
* What have people achieved in past according to the elogs© of the measurements?
* What do we expect the effect of 1:50 to be? How much offset does this make in the MICH/PRC/SRC loops? How much offset is too much?
Recall that we are using frontal modulation with a rather small Schnupp Asymmetry... 
|
|
5506
|
Wed Sep 21 21:13:35 2011 |
rana | Update | IOO | AM modulation misery | How about changing the x-axis of all these plots into meters or picometers and tell us how wide the PRC resonance is? (something similar to the arm cavity linewidth expression)
Also, there's the question of the relative AM/PM phase. I think you have to try out both I & Q in the sim. I think we expect Q to be the most effected by AM. |
5472
|
Mon Sep 19 23:19:40 2011 |
Keiko | Update | IOO | AM modulation mistery | Keiko, Anamaria
We started to investigate the AM modulation mistery again. Checking just after the EOM, there are AM modulation about -45dBm. Even if we adjust the HWP just before the EOM, AM components grow up in 5 mins. This is the same situation as before. Only the difference from before is that we don't have PBS and HWP between the EOM and the monitor PD. So we have a simpler setup this time.
We will try to align the pockells cell alignment tomorrow daytime, as it may be a problem when the crystal and the beam are not well parallel. This adjustment has been done before and it didn't improve AM level at that time. |
|