40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 16 of 344  Not logged in ELOG logo
ID Date Author Type Category Subjectup Text Attachments
  11679   Fri Oct 9 13:31:21 2015 ericqUpdateLSCALS plant shapeTo get a better look at how to do fast
ALS, I took some "Plant TF"
measurements of the X arm. 
 xarm_plantTFs.pdf 
  11680   Fri Oct 9 14:50:18 2015 KojiUpdateLSCALS plant shapeALS is the comparison of the
PSL laser freq vs the
end laser freq that is locked to the arm
  
  11681   Fri Oct 9 16:23:25 2015 ericqUpdateLSCALS plant shapeAh, I understand it now! Since the additive
offset path keeps the post-cavity frequency
TF flat, the pre-cavity frequency must grow
  
  14995   Mon Oct 28 23:20:11 2019 gautamUpdateALSALS power budget 


IR
  
  11378   Thu Jun 25 18:20:15 2015 ericqUpdateLSCALS reconstruction in progressI've been working on getting a working
ALS up and running. Things are in a bit of
a transient state right now; I'm off
  
  11379   Fri Jun 26 03:24:18 2015 ericqUpdateLSCALS reconstruction in progressToo sleepy to make full ELOG. Stay tuned. 

Two 25dB amplifiers (with fins!)
are living in the top shelf on the PSL table,
  
  11381   Mon Jun 29 12:28:45 2015 ericqUpdateLSCALS reconstruction in progressTurns out the reason that the BEATY signal
wasn't working is that one of the two
RF amplifiers (both of which are model ZHL-32A),
  
  12578   Mon Oct 24 11:39:13 2016 gautamUpdateGeneralALS recoveredI worked on recovering ALS today. Alignments
had drifted sufficiently that I had to to
the alignment on the PSL table onto the green
 ALSOutOfLoop20161024.pdfXendPDHOLTF20161024.pdf 
  13180   Wed Aug 9 19:21:18 2017 gautamUpdateALSALS recoverySummary:

Between frequent MC1 excursions,
I worked on ALS recovery today. Attachment
 ALS_oolSpec.pdf 
  13519   Tue Jan 9 21:38:00 2018 gautamUpdateALSALS recovery
Aligned IFO to IR.

Ran
dither alignment to maximize arm transmission.
Centered
Oplev reflections onto their respective QPDs
 GreenLockStability.pngALS_OLTFs_20180109.pdfALS_OLTF_data_20180109.tar.bz2 
  9122   Wed Sep 11 17:35:38 2013 JenneUpdateLSCALS requirementI have done a quickie look at Optickle
to see how the linewidth of an arm cavity
changes versus the configuration. 
 ArmLinewidthComparison.pngLinewidthComparison.png 
  14846   Thu Aug 15 18:54:54 2019 gautamUpdateALSALS sensing noise due to IMCSummary:

I came aross an interesting
suggestion by Yutaro that KAGRA's
 ALSsensingNoise.pdf 
  14847   Fri Aug 16 04:24:03 2019 ranaUpdateALSALS sensing noise due to IMCWhat about just use high gain feedback
to MC2 below 20 Hz for the IMC lock? That
would reduce the excess if this theory is
  
  8841   Fri Jul 12 23:13:32 2013 manasaUpdateGreen LockingALS sensor noise[Annalisa, Koji, Manasa]

In order to improve the ALS stability
 X_ALS_0712.pdfY_ALS_0712.pdf 
  9171   Fri Sep 27 20:28:10 2013 manasaUpdateGreen LockingALS servo[Masayuki, Manasa]
I. ALS servo loops
After fixing things with the phase
 OLTF.pdfphase_badget_xarm_ALS.pdf 
  9861   Sun Apr 27 21:30:59 2014 KojiUpdateLSCALS servo characterizationThe measured openloop TF of the ALS servo
for each was characterized by a ZPK model.
The openloop TF can be modeled by:
 ALSX_OLTF.pdfALSY_OLTF.pdf 
  8792   Wed Jul 3 01:49:46 2013 AnnalisaUpdateGreen LockingALS servo configuration[Koji, Annalisa, Manasa]
Today we worked on the ALS servo
stabilization for the Y arm.
 ALSALS_calibrated 
  8793   Wed Jul 3 03:06:29 2013 AnnalisaUpdateGreen LockingALS servo configuration 
I realized that I cannot open the
attached plots. I'll fix them tomorrow.
  
  9183   Tue Oct 1 17:14:53 2013 masayukiUpdateGreen LockingALS servo filters modified 
 [Manasa, Masayuki]
 OLTF.pdffilter_change.pdf 
  13595   Wed Jan 31 22:32:11 2018 gautamUpdateALSALS signal chain + power budgetSummary:

 FiberALS_PowerBudget.pdfpreampProposed.pdf 
  13597   Thu Feb 1 15:31:12 2018 gautamUpdateALSALS signal chain + power budgetSummary:

A
  
  13613   Wed Feb 7 10:16:26 2018 gautamUpdateALSALS signal chain + power budgetAfter emailing the technical team at Menlo,
I have uploaded the more detailed information
they have given me on our wiki.
  
  13600   Fri Feb 2 13:16:55 2018 gautamUpdateALSALS signals whitening switchingWhile setting up for this measurement,
I noticed something odd with the whitening
switching for the ALS channels. For the usual
 ALS_whitening_switching.pdfALS_whitening_switching_works.pdf 
  10302   Thu Jul 31 01:08:54 2014 KojiUpdateLSCALS stability check- ALS X/Y arm stability was checked by
IR locked arms.
- Basically the stability looks same
 postXGreenUpgradeCheckup.pdf 
  14486   Mon Mar 18 20:22:28 2019 gautamUpdateALSALS stability testI'm running a test to see how stable
the EX green lock is. For this purpose, I've
left the slow temperature tuning servo on
  
  9228   Wed Oct 9 22:58:34 2013 ManasaUpdateGreen LockingALS stabilizationAfter Jenne and Masayuki told that they
were not able to stabilize the ALS for either
arms yesterday, I looked into things with
 ALS_XARM_OLTF.pdf 
  12105   Thu May 5 03:05:37 2016 gautamUpdateendtable upgradeALS status update[ericQ, gautam]

Today we spent some time looking
into the PDH situation at the X end. A summary
 ALS_noiseSpec_5May2016_2.pdfCoherence_5May2016.pdfimage.jpeg 
  12108   Thu May 5 14:05:01 2016 ranaUpdateendtable upgradeALS status updateAll seems very fishy. Its not good to put
attenuators and filters in nilly-willy.


Once the post-PD bandpass
  
  11467   Thu Jul 30 14:27:18 2015 EveUpdateSummary PagesALS, ASC, LSC Summary PagesI've switches the ALS, ASC, and LSC
plots on the summary pages from plotting
raw frames, to plotting minute trends, instead.
  
  8679   Wed Jun 5 14:43:42 2013 AnnalisaUpdateLSCALS-TRY_OUT DQ channels

    

       
            
  
  8667   Mon Jun 3 22:36:07 2013 ranaUpdateLSCALS-TRY_OUT needs anti-whitening After
working some more on the EY table, we are
 try.pdf 
  8671   Tue Jun 4 16:04:34 2013 AnnalisaUpdateLSCALS-TRY_OUT needs anti-whitening

    

       
            
  
  11334   Thu May 28 21:10:46 2015 KojiUpdateGreen LockingALS-X noise huntingI have been looking at the X-end ALS setup.
I was playing with the control bandwidth
to see the effect to the phase tracker output
 150528_ALS.pdf 
  11931   Thu Jan 14 02:33:37 2016 ericqUpdateLSCALSX Noise still anomalously high [ericq, Gautam]

We checked the UGF of the AUX X
PDH servo, found a ~6kHz UGF with ~45 degree
 2016-01-14_ALSXspectra.pdfPDHsig.pdf 
  11937   Tue Jan 19 17:54:39 2016 gautamUpdateLSCALSX Noise still anomalously high While carrying out my end-table power investigations,
I decided to take a quick look at the out-of-loop
ALSX noise - see the attached plot. The feature
 2016_01_19_ALS_OutOfLoop.pdfGreen_Locking_Trends.png 
  11803   Mon Nov 23 23:42:56 2015 ericqUpdateLSCALSY recovered[ericq, gautam]

Gautam couldn't observe a Y
green beatnote earlier, so we checked
  
  11804   Tue Nov 24 01:14:23 2015 KojiUpdateLSCALSY recoveredSorry, I completely forgot to turn the
Marconi on...
  
  7007   Mon Jul 23 18:41:15 2012 JamieUpdateGreen LockingALS_END.mdl model added for end station green ALS channelsThe end sus models (c1scx and c1scy) both
contain some ALS stuff.  This stuff
could maybe be moved to their own models,
 alsend.png 
  7009   Mon Jul 23 19:00:26 2012 KojiUpdateGreen LockingALS_END.mdl model added for end station green ALS channelsThis is a good modification. We just need
to check how the ALS scripts are affected.

  
  5588   Fri Sep 30 17:40:03 2011 kiwamuUpdateIOOAM / PM ratio[Mirko / Kiwamu]
 We have
  
  5606   Mon Oct 3 20:02:59 2011 SureshUpdatePSLAM / PM ratio[Koji, Suresh]
In the previous measurement, the
PDA 255 had most probably saturated at DC,
  
  5616   Tue Oct 4 16:58:45 2011 SureshUpdatePSLAM / PM ratioCorrection:        Koji noted that Mirko
actually reports a PM modulation index of
0.17 for the 11 MHz sideband (
  
  15197   Fri Feb 7 09:45:03 2020 shrutiUpdateGeneralAM at X endI took a few AM TF measurements at the
X end for which I:


Misaligned the ITMX (then
  
  5249   Tue Aug 16 16:59:20 2011 AnamariaUpdateRF SystemAM in the PMKiwamu, Keiko, Anamaria
Looking at the I and Q signals coming
from REFL11 and REFL55 we saw large offsets,
  
  15020   Thu Nov 7 17:46:10 2019 shrutiUpdateALSAM measurement at X endSome details:

- There
was a SR560+SR785 (not connected for measurement)
placed near the X end which I moved; it is
 AMTF20191107.png 
  14979   Fri Oct 18 20:21:33 2019 shrutiUpdateALSAM measurement attempt at X end[Shruti, Rana]

- At the X end, we set up the network
analyzer to begin measurement of the AM transfer
  
  3603   Thu Sep 23 23:24:43 2010 rana, johnny, taraSummaryPSLAM modulate AOM to measure RefCav Thermo-Optic coefficientBig Johnny and I hacked a function
generator output into the cross-connect of
the 80 MHz VCO driver so that we could modulate
  
  5763   Sat Oct 29 22:57:03 2011 MirkoUpdateLSCAM modulation due to non-optimal SB frequency[Kiwamu, Mirko]
Non-optimal 11MHz SB frequency causes
PM to be transformed into AM.
 IMC.pdf 
  5774   Tue Nov 1 13:41:38 2011 MirkoUpdateLSCAM modulation due to non-optimal SB frequency


   
        
            
 IMC.pdf 
  5503   Wed Sep 21 17:42:35 2011 ranaUpdateIOOAM modulation miseryI'd like to see some    
ELOG V3.1.3-