40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 165 of 344  Not logged in ELOG logo
ID Date Author Typeup Category Subject Text Attachments
  6367   Tue Mar 6 23:14:38 2012 ranaUpdateSUSOptical Lever had bad filters We found that that bounce (16.1 Hz)
and roll (23.5 Hz) modes on the ITMX were
much higher than on the ITMY. After some
 Untitled.png 
  6368   Tue Mar 6 23:37:31 2012 keikoUpdateSUSMICH noise budget - SUS checkHere are the OSEM spectrum of MICH suspensions
(BS, IX, IY). Bounce and Roll modes are shown
on 16 and 23 Hz. The filters for them has
 6x 
  6369   Wed Mar 7 04:08:48 2012 kiwamuUpdateSUSBS SIDE gain was too lowThe
BS SIDE damping gain seemed too low. The
gain had been 5 while the rest of the suspensions
  
  6370   Wed Mar 7 11:20:23 2012 steveUpdateSUSoplev qpd offsets zeroedAll oplev qpd quadrons were zeroed by offset 
in blocked dark condition.
  
  6371   Wed Mar 7 11:44:29 2012 JenneUpdateGreen LockingXgreen beatnote cable made, laidThe Xgreen PD now has a cable going over
to the beatbox. Once beatbox characterization
is done I can re-find the beat, and we can
  
  6372   Wed Mar 7 13:30:17 2012 JimUpdatePEMadded TPs and JIMS channels to PEM front-end model [Jim Ryan]
The PEM model has been modified now
to include a block called 'JIMS' for the
  
  6374   Wed Mar 7 15:56:36 2012 KojiUpdateLSC22/110MHz path for POPThe RF separator installed comprises of
the Minicircuits filters cascaded as in the
figure below. 
 RFseparator.pngimpedance.pdftransmission.pdf 
  6375   Wed Mar 7 16:32:09 2012 keikoUpdateLSCOSA I swap an OSA at PSL and OSA at REFL.
It was because the PSL-OSA had a better resolution,
so we place this better one at REFL. The
  
  6376   Wed Mar 7 17:39:40 2012 keikoUpdateLSCMICH noise budget on 5 Mar This is the calibrated MICH noise
budget on Mar 5. There was a sharp peak at
1Hz and a blob on 3 Hz. The demod phase was
 Mar5-MICHbudget.pngMar5-MICHbudget.png 
  6378   Wed Mar 7 19:10:06 2012 kiwamuUpdateLSCREFL OSA : how the signal look likeJust a quick report on the REFL OSA.

The attached plot below shows the
 OSArefl.png 
  6379   Wed Mar 7 20:06:23 2012 KojiUpdateLSCREFL OSA : how the signal look likeI'm puzzled why the 11MHz peak can be such
high considering 1.7~2 times smaller the
modulation depth.
  
  6380   Wed Mar 7 20:53:13 2012 keikoUpdateLSCMICH noise budget on 5 Mar 
 
 Mar6-MICHbudget.png 
  6381   Wed Mar 7 21:13:30 2012 ranaUpdateDAQNDS2 I noticed that NDS2 was not running
on mafalda as it should be. Instead, there
were a couple of zombie MEDMs using up 99%
  
  6382   Wed Mar 7 22:04:05 2012 kiwamuUpdateLSCREFL OSA : how the signal look likeI was also wondering about the same thing,
comparing with what Mirko obtained before
with the same OSA ( 
  
  6384   Wed Mar 7 23:29:28 2012 keikoUpdateLSCREFL OSA observation kiwamu, keiko
 
 
 REFLOSA.png 
  6385   Thu Mar 8 00:57:48 2012 keikoUpdateLSCMICH noise budget on Mar 5, Mar 6, and oldHere is the recent two noise budgets of
MICH, with the old measurement by Jenne.
The most latest Mar 6 data is quite close
 Mar7MICHbudgettotal.png 
  6386   Thu Mar 8 04:13:12 2012 kiwamuUpdateLSCupdate on the locking activity[Keiko / Kiwamu]
 Some updates on the locking
activity:
  
  6388   Thu Mar 8 23:37:03 2012 kiwamuUpdateIOOdither Y arm dither scriptI
disabled the feedback to the PZT1 PITCH in
the Y arm dithering scripts so that it won't
  
  6390   Fri Mar 9 10:44:57 2012 steveUpdateRF SystemOSAOptical spectrum analyzers like the Attachment
made by Coherent , Meles Griot- CVI and Spectral
Product are all discontinued.
 OSA.pdf 
  6393   Fri Mar 9 13:34:13 2012 keikoUpdateLSCupdate on the locking activityWe tried to measure the sensing matrix
for MICH and PRCL last night. They look too
much mixed as we expect... the matrix may
  
  6395   Fri Mar 9 16:00:46 2012 steveUpdateGreen Lockinglaser emergency shut down switch replaced at the south endOver-sized local laser emergency switch
was held by large C clamp at the south end.
This was replaced by a smaller one and it
  
  6397   Fri Mar 9 20:44:24 2012 Jim LoughUpdateCDSDAQ restart with new ini fileDAQ reload/restart
was performed at about 1315 PST today. The
previous ini file was backed up as c1pem20120309.ini
  
  6398   Sat Mar 10 02:00:03 2012 keikoUpdateLSCupdate on the locking activityITMX and ITMY balance for the MICH excitation
(lockin) is adjusted again. Now it's ITMx
= -0.992, ITMy = 1 for MICH (lockin output
  
  6400   Mon Mar 12 01:04:18 2012 keikoUpdateLSCRAM simulation update, RAM LSC matrix I calculated the DRMI RAM LSC
matrix with RAM and the operation point offsets.

    configuration: C1 DRMI
  
  6401   Mon Mar 12 18:57:58 2012 keikoUpdateLSCRAM simulation update, RAM LSC matrix

    

       
            
  
  6402   Mon Mar 12 22:14:56 2012 SureshUpdateRF SystemCalibration of Demod Board Efficiency. I have completed the calibration of the
demod board efficiencies.  Here is the
schematic of the set-up.
 Calibration_Schematic.pngDemod_calib.pngDemod_calib.txtDemod_calib.xlsx 
  6403   Tue Mar 13 07:04:55 2012 kiwamuUpdateLSCevolution of the sensing matrix in PRMI as a function of timeThe
punch line is -- the sensing matrix still
looks strange in the PRMI configuration.
 PRCL.pngMICH.png 
  6404   Tue Mar 13 13:28:31 2012 Ryan FisherUpdateCDSDAQ restart with new ini fileExtra note:  This was the ini file that was
edited:
/cvs/cds/rtcds/caltech/c1/chans/daq/C1PEM.ini
  
  6405   Tue Mar 13 16:40:06 2012 kiwamuUpdateLSCevolution of the sensing matrix in PRMI as a function of time: detailsHere
I describe the measurement of the sensing
matrix.
 lockins_MICH.png 
  6406   Tue Mar 13 16:56:19 2012 kiwamuUpdateLSCevolution of the sensing matrix in PRMI as a function of timeNext steps:

    Compare the obtained sensing
matrix with an Optickle model. Particularly
  
  6407   Tue Mar 13 19:14:40 2012 kiwamuUpdateLSCNoise estimatino in the REFL33Q as a MICH sensor
A feasibility study of the REFL33Q as a MICH
sensor was coarsely performed from the point
 NB_REFL33.png 
  6409   Wed Mar 14 03:34:44 2012 kiwamuUpdateSUSAdjustment of BS suspension output matrix : coupling from SIDE to POS[Rana / Kiwamu]
 We put some elements in the
 Untitled.png 
  6410   Wed Mar 14 04:03:37 2012 kiwamuUpdateIOOPZT1 and associate extra worksAs the PZT1 has not been functional, I
have been aligning the Y arm to the input
beam instead of aligning the beam to the
  
  6411   Wed Mar 14 04:19:51 2012 kiwamuUpdateLSCREFL33Q for MICH control : not good I tried the REFL33Q for controlling
MICH in the PRMI configuration (#6407)
 Untitled.png 
  6412   Wed Mar 14 05:26:39 2012 interferomter tack forceUpdateGeneraldaytime tasksThe
following tasks need to be done in the daytime
tomorrow.
  
  6413   Wed Mar 14 10:06:26 2012 steveUpdateGreen Lockingdichroic mirror quotesDichroic
mirror quotes are in the wiki.
ATF is pricy.
  
  6414   Wed Mar 14 13:16:50 2012 kiwamuUpdateLSCA correction on Noise estimatino in the REFL33QA
correction on the previous elog about the
REFL33Q noise:
  
  6416   Wed Mar 14 14:09:01 2012 interferomter tack forceUpdateGeneraldaytime tasks

    
        
  
  6417   Wed Mar 14 16:33:20 2012 keikoUpdateLSCRAM simulation / RAM pollution plotIn the last post, I showed that SRCL element
in the MICH sensor (AS55I-mich) is chaned
1% due to RAM.
 Mar14pollution.pngRAMexampleplot.png 
  6418   Wed Mar 14 16:39:02 2012 SureshUpdateGeneralREFL165 signal was not reaching demod board : Fixed

    

       
            
 Test_CDS_Calibration.png 
  6419   Wed Mar 14 21:01:36 2012 keikoUpdateLSCevolution of the sensing matrix in PRMI as a function of timeThis is the simulated signals
to compare with the original post #6403
  
  6420   Wed Mar 14 23:02:09 2012 KojiUpdateLSCLocking activityKiwamu and Koji
The target is to realize DRMI or
PRMI + one arm with ALS.
  
  6423   Fri Mar 16 06:17:56 2012 SureshUpdateElectronicsREFL165 calibration : measurements 
These are the measurements for estimating
the amplitude of the signal recorded in the
 IMG_0552.JPG 
  6424   Fri Mar 16 10:37:52 2012 JenneUpdateElectronicsJenne Laser

    

       
            
  
  6425   Fri Mar 16 16:01:53 2012 ranaUpdateElectronicsREFL165 calibration : measurements To characterize the RF V to counts
we need to know the state of the whitening
filter board. Was the filter on or off ?
  
  6426   Fri Mar 16 16:03:03 2012 kiwamuUpdateIOOMC alignment servo : put some offsets in the TRANS QPD signalThe
MC alignment servo wasn't great in the last
1 hour or so as it kept disturbing the MC
  
  6427   Sun Mar 18 00:29:24 2012 DenUpdatePEMsts-2I've turned off the power of the STS-2
readout box as it provides outputs with ~10
Volts DC offset! AA filter box works in the
  
  6428   Mon Mar 19 21:25:31 2012 SureshUpdateElectronicsREFL165 calibration : measurements


   
        
            
  
  6429   Tue Mar 20 09:59:01 2012 steveUpdateIOOLaser tripped offToday is janitor day. It still does not
explain why the 2W Innolight tripped off
about an hour ago. All back to normal. 
  
  6430   Tue Mar 20 16:53:48 2012 steveUpdatePEMcranes maintenance & certified inspection of 2012Fred Goodbar of Konecrane has completed
the annual certified crane inspection and
maintenance of our cranes as required in
  
ELOG V3.1.3-