40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 163 of 341  Not logged in ELOG logo
IDup Date Author Type Category Subject Text Attachments
  8149   Sat Feb 23 16:54:24 2013 JenneUpdateLSCcan't lock Y armI'm not sure that Yuta had found the real
Yarm flashes last night.  When I came
in today, the Yarm would flash.  However
  
  8150   Sat Feb 23 17:14:59 2013 yutaUpdateLSCcan't lock Y armJenne found that;
  0. If all mirrors are "aligned,"
Yarm flashes.
  
  8151   Sat Feb 23 18:01:38 2013 ZachSummaryElectronicsReplacement for the AD743: OPA140 and OPA827Rana suggested that I measure the OPA827
and OPA140 noise with high source impedance
so as to see if we could find the low-frequency
 OPA140_OPA827_noise_vs_Rs.pngScreen_Shot_2013-02-24_at_12.12.23_PM.pngScreen_Shot_2013-02-24_at_12.12.43_PM.png 
  8152   Sun Feb 24 00:14:28 2013 ManasaUpdateSUSSUS SummaryI tried to fix the alarms for sensors on
the SUS summary screen. I checked earlier
elogs and found the setSensors.py script.
  
  8153   Sun Feb 24 16:49:00 2013 ranaSummaryElectronicsReplacement for the AD743: OPA140 and OPA827  This looks pretty good already.
Not sure if we can even measure anything
reasonable below 0.1 Hz without a lot of
  
  8154   Sun Feb 24 17:54:34 2013 ranaUpdateSUSSUS Summary 
 I asked John Z to talk with
Jamie and then install a new NDS2 server
  
  8155   Mon Feb 25 08:22:03 2013 SteveUpdateVACpumpdown at day 4 All normal, IFO pressure 1.5e-5 Torr
RGA is pumped by TP-3 in back ground
mode.
 4d.png66d@atm.png 
  8156   Mon Feb 25 13:01:39 2013 KojiSummaryGeneralQuick, compact, and independent tasks- IMC PDH demodulation phase adjustment
- Permanent setup for green transmission
DC PDs  on the PSL table
  
  8157   Mon Feb 25 15:30:29 2013 yutaUpdateAlignmentY arm locked, both colors[Koji, Yuta]

We aligned Y arm to Y green and tweaked
  
  8158   Mon Feb 25 17:58:28 2013 ranaUpdateAlignmentY arm locked, both colors 
 That's good news. I was ready
to give up and say we should vent and remove
  
  8159   Mon Feb 25 20:04:22 2013 JamieUpdateSUSsuspension controller model modifications in prep for global damping initiative[Jamie, Brett, Jenne]
We made some small modifications
to the 
 sus_update.pngodd-mc2-stuff.png 
  8160   Mon Feb 25 20:25:33 2013 BrettUpdateSUSNew Global Damping MEDM ScreensGlobal damping screens are in progress
for the new global damping infrastructure
Jamie discussed in log #8159. The main overview
  
  8161   Mon Feb 25 20:49:07 2013 BrettUpdateSUSMinor Mod made to SUS_GLOBAL block I made a minor modification to install
some output filters in the new global damping
GLOBAL box in c1sus.mdl. These will be needed
  
  8162   Mon Feb 25 21:25:14 2013 yutaUpdateAlignmentboth arms locked in IR[Jenne, Evan, Yuta]

After Y alignment, X arm is aligned
 QUAD1_1045890588.png 
  8163   Mon Feb 25 22:30:40 2013 JenneBureaucracyGeneralaction items for PRFPMI 
 CDS:
    - Check out ASS
  
  8164   Mon Feb 25 22:42:32 2013 yutaSummaryAlignmentcurrent IFO situation[Jenne,Yuta]

Both arms are aligned starting from
 IPANGdrift.png 
  8165   Tue Feb 26 01:49:27 2013 JenneUpdateLockingPRMI locked[Jenne, Yuta]
We began the evening, after alignment
of all optics was good (arms flashing, PRC
  
  8166   Tue Feb 26 02:04:51 2013 KojiUpdateLockingPRMI lockedOne of the biggest issues we had was that
any Q signals (i.e. the quadrature where
PRCL is absent.) of REFL11/33/55/(165) haven't
  
  8167   Tue Feb 26 09:55:46 2013 SteveUpdateSAFETYEvan receives safety trainingEvan got 40m specific safety training today.   
  8168   Tue Feb 26 10:17:44 2013 JamieUpdateSUSremoved global/local switch from sus_single_control[jamie, brett]
Yesterday
we added some new control logic to the sus_single_control
  
  8169   Tue Feb 26 10:20:31 2013 JamieUpdateSUSMC2 suspension controller reverted to library partI made good on my threat from yesterday
to convert the MC2 suspension controller
to the library part.  Whatever changes
  
  8170   Tue Feb 26 11:55:11 2013 ManasaUpdateLockingFPMI locked [Yuta, Manasa]

FPMI locked.
  
  8171   Tue Feb 26 15:32:47 2013 JenneUpdateLockingFPMI locked

    

       
            
  
  8172   Tue Feb 26 16:13:18 2013 BrettUpdateSUSITMY and ETMY mysterious loop gain difference of 2.5While doing initial measurements for the
new global damping infrastructure I discovered
that the ETMY loop between the OSEM actuation
 Screenshot.png 
  8173   Tue Feb 26 17:36:28 2013 ChloeUpdate QPD CircuitI corrected the circuit diagram I constructed
last time - it would read 0 output most of
the time because I made a mistake with the
  
  8174   Tue Feb 26 17:56:15 2013 BrettUpdateSUSGlobal Damping UpdateThe global damping input and output matrices
were installed to run for the Y-arm. Since
we are using just one arm for now, only the
  
  8175   Wed Feb 27 00:08:43 2013 JenneUpdateIOOMeditations on converting TT channels to be more SUS-likeJamie and I have had a few back-and-forths
on this, but I wanted to write down my thoughts
on the parts of the SUS infrastructure that
  
  8176   Wed Feb 27 00:56:01 2013 JenneUpdateASSMotivation for reactivating the ASSI am putting a little bit of brain power
into reviving the ASS, and I want to write
down what the motivation is, and what the
  
  8177   Wed Feb 27 01:09:53 2013 yutaUpdateLockingPRMI sideband/carrier locked[Jenne,Yuta]

We succeeded in locking PRMI in sideband
 6x 
  8178   Wed Feb 27 02:21:55 2013 JenneUpdateASSMotivation for reactivating the ASSI have modified the MeasureSpotPositions.py
script to accept the arms as valid cavities
(it used to give an error "Sorry, this
  
  8179   Wed Feb 27 02:44:39 2013 JenneUpdateLockingDRFPMI flashesBefore Yuta left, I asked him to restore
all optics to last saved values, to avoid
hysteresis.
  
  8180   Wed Feb 27 02:52:40 2013 JenneOmnistructureSAFETYBack door unlockedDid someone unlock the back door by the
(unofficial) bike storage lately?  Out
of habit, I checked the door behind me while
  
  8181   Wed Feb 27 11:22:54 2013 yutaUpdateComputersbackup crontabI made a simple script to backup crontab
(/opt/rtcds/caltech/c1/scripts/crontab/backupCrontab).
  
  8182   Wed Feb 27 11:59:43 2013 yutaUpdateSUSPRM/BS coil re-balancedI re-adjusted coil gains and f2a filters
for PRM and BS.
I'm not sure what happened to PRM
 PRM_f2a20130227.pngBS_f2a20130227.png 
  8183   Wed Feb 27 14:39:59 2013 AnnalisaUpdateLSCFibre laid for RFPD audio [Annalisa, Jenne, Rana, Steve]
We installed the fibres on cable
trays the 1Y2 and the Control Room.
  
  8184   Wed Feb 27 14:53:02 2013 SteveUpdateLSCwhat is the Fibox ?Fibox
FBAI-M 20bit units were connected with
multimode
  
  8185   Wed Feb 27 14:59:01 2013 EvanUpdate Altered MC demodulation phase I took out a short (~12 cm) SMA cable
from the "LO input" path into the
MC demod board in an attempt to maximize
 Q_and_I_before.epsQ_and_I_after.eps 
  8186   Wed Feb 27 17:43:54 2013 RijuUpdate Photodiode transimpedanceHere is the transimpedance for the other
PD used for MC REFL
 TFnewreflpd.pdfNewREFL_z.pdf 
  8187   Wed Feb 27 18:01:46 2013 KojiUpdate Photodiode transimpedanceHow
much is the exact resonant frequency?
And 
  
  8188   Wed Feb 27 18:17:05 2013 RijuUpdate Photodiode transimpedance

    

       
            
  
  8189   Wed Feb 27 18:38:51 2013 RijuUpdate Photodiode transimpedance

    

       
            
  
  8190   Wed Feb 27 19:27:29 2013 AnnalisaHowToCOMSOL TipsMirror support Eigenfrequency I studied the eigenfrequencies of
a mirror support using COMSOL.
 
 IronSupport.pngIronSupportEigenfreq.png 
  8191   Wed Feb 27 20:10:43 2013 ranaUpdateLockingDRFPMI flashes 
 If its true that there have
been large flashes, then there indeed might
  
  8192   Wed Feb 27 20:50:41 2013 ManasaUpdateLSC22/110MHz path for POP[Yuta, Manasa]

Modified POP path.
 POP.png 
  8193   Wed Feb 27 22:28:53 2013 BrettUpdateSUSGlobal Damping Update New excitation points were added
after the global damping loops for more testing
options. The updated c1sus.mdl model was
 DampNoise_to_YARM_fig_27Feb2013.png 
  8194   Wed Feb 27 22:46:53 2013 Max HortonUpdateSummary PagesMultiprocessing ImplementationOverview: In order to make the code
more maintainable, I need to factor it into
different well-documented classes. 
  
  8195   Wed Feb 27 23:19:54 2013 ranaUpdateSummary PagesMultiprocessing Implementation  At first I thought that this
was goofy, but then I logged in and saw that
Megatron only has 8GB of RAM. I guess that
  
  8196   Thu Feb 28 02:43:49 2013 yutaUpdateLSCsome qualitative evidence of PRMI sideband lock[Manasa, Yuta]

Since we have setup POP22 PD now(
 PRMIsideband.png 
  8197   Thu Feb 28 03:25:27 2013 yutaUpdateLSCPR gain ~ 25 from PRMI carrier lock[Manasa, Yuta]

We locked PRMI in carrier. 
 PRMIcarrier.png 
  8198   Thu Feb 28 03:41:31 2013 KojiUpdateLSCPR gain ~ 25 from PRMI carrier lockVERY
GOOD! 
This is how the carrier lock PRMI
  
ELOG V3.1.3-