40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 163 of 344  Not logged in ELOG logo
ID Date Authorup Type Category Subject Text Attachments
  12788   Thu Feb 2 12:17:48 2017 SteveUpdateGeneral USB microscopeThis
AmScope microscope would have 3.5x-180x
magnification, calibratable measurement function,
  
  12802   Mon Feb 6 10:05:28 2017 SteveUpdateSUSclamped cablesThe bottom 5 cable connections from Sat-Amp
to Whittering Filter at 1X5 were clamped
today.
 clamped.jpg 
  12808   Tue Feb 7 16:23:49 2017 SteveUpdateGeneralpower interruption tomorrow                                                                                                                                  
received this note: at 4:11pm Tuesday, Feb
7, 2017
  
  12813   Thu Feb 9 08:03:08 2017 SteveUpdateGeneral USB microscope orderedhttp://www.amscope.com/3-5x-180x-boom-stand-trinocular-zoom-stereo-microscope-with-144-led-ring-light-and-10mp-camera.html
will be ordered today.
  
  12843   Tue Feb 21 17:05:14 2017 SteveUpdateGeneralProjector lamp replacedThis bulb was
blown out on Feb 4, 2017 after 2 months
of operation.
 blownup.jpg 
  12848   Thu Feb 23 14:50:26 2017 SteveUpdateGeneral USB microscope returnedThe microscope shipped back to the vendor
for credit yesterday.

  
  12853   Mon Feb 27 15:33:10 2017 SteveUpdateVACRGA scan at day 130Valve configuration: vacuum normal

Vacuum envelope: 23.5 C

RGA head: 46.6 C
 rgascan@130d.png 
  12858   Wed Mar 1 08:28:04 2017 SteveUpdateOptical Leversoplev laser RINGautam and Steve,

New JDSU 1103P HeNe oplev laser
RIN was measured on the SP table with cover
 RIN_1103P.pngRIN_HeNe.png 
  12860   Wed Mar 1 17:25:28 2017 SteveUpdateLSCMCREFL condition picturesGautam and Steve,

 

Our MCREFL rfpd
 IMG_3646.JPGmcRefl_1.jpgmcRefl_3.jpgmcRefl_5.jpg 
  12863   Thu Mar 2 13:59:04 2017 SteveUpdateOptical Leversoplev laser RINThe laser got much better at low frequency
as it warmed up. This laser is almost as
good as the electronics?
 1103P@2d.png 
  12866   Fri Mar 3 17:24:21 2017 SteveUpdateOptical Leversoplev laser RINCorrected oplev laser RIN plot at
day 3

RXA:
 3march17.pdf 
  12868   Mon Mar 6 09:12:59 2017 SteveUpdatesafety crane inspection 2017All 3 cranes inspected by professional
Fred Goodbar of Konecranes and load tested
with 450 lbs at max reach on Friday, March
 inspection_2017.jpg 
  12871   Mon Mar 6 16:32:36 2017 SteveUpdateGeneralold NPRO 16 years old Lightwave NPRO M126-1064-700,
sn 415 power output is tripping continously
to zero.
  
  12872   Tue Mar 7 15:17:19 2017 SteveBureaucracyGeneralproperty tagProperty tag found.  property_tag.jpg 
  12873   Wed Mar 8 15:28:37 2017 SteveUpdateOptical Leversoplev laser RINGautam and Steve,




 RIN.jpgRIN_1103P_rotated.pdf 
  12876   Thu Mar 9 17:26:43 2017 SteveUpdateGeneralattempted ETMY picture takingI removed the video monitoring can and
replaced it with Olympus SP-570UZ camera.
It has no IR blocker. The OSEM light are
  
  12881   Fri Mar 10 18:00:22 2017 SteveUpdateGeneralattempted ETMY picture takingYour technique works Koji  P3100044.JPGP3090024.JPG 
  12884   Mon Mar 13 16:47:41 2017 SteveUpdatePEMY-arm air conditon belts replacedThe east end AC unit is arching over and
running rough at CES. Called for mechanic.......

Both belts were replaced and the
  
  12885   Tue Mar 14 09:08:11 2017 SteveUpdateOptical LeversETMX HeNe is deadETMX oplev laser is dead. It will be replaced
this after noon. Sus damping recovered.
 this_morning.png 
  12886   Tue Mar 14 10:40:30 2017 SteveUpdateSUSOSEM filters are inWe have 50 pieces in the clean cabinet.  filters.jpg 
  12888   Tue Mar 14 15:05:18 2017 SteveUpdateOptical Levershistory of ETMX oplev laser 




 ETMX_1103P_3y.png 
  12889   Thu Mar 16 08:22:16 2017 SteveUpdateSUSETMX damping Finally I see what kicks the sus damping
off

 laser_power_glitch.png 
  12890   Fri Mar 17 10:47:16 2017 SteveUpdateOptical Levers ETMX oplev laser replacedJDSU 1103P. sn T8070866, made March 2007,
output power 2.7 mW,  on pd 17,750 counts,

GV
  
  12892   Fri Mar 17 15:30:39 2017 SteveSummarySUSoplev laser summary updated   
     March  17, 
2017        
 oplev_sums.png 
  12908   Mon Mar 27 15:36:27 2017 SteveUpdatePEMparticle counter inside of PSL enclousure 




 HEPA_flow_effects.png 
  12909   Mon Mar 27 16:01:55 2017 SteveUpdatePEMX arm AC set to 68F 

The X arm air conditioner was not
regulating properly. The arm temp was warmer
  
  12913   Tue Mar 28 16:47:40 2017 SteveUpdatesafetyProjector bulb is out againThree replacement
bulbs ordered

Rana can discribe
  
  12915   Wed Mar 29 09:24:28 2017 SteveUpdateloresummery pagesThe summery pages are working at a slow
motion speed. It's response time 12 minutes.
  
  12917   Wed Mar 29 16:38:00 2017 SteveOmnistructureTreasuresus fiber illluminated   fiber.jpg 
  12921   Fri Mar 31 10:16:07 2017 SteveUpdatesafetylaser safety glasses annual inspectionLaser safety glasses cleaned in "
Dawn Ultra " mild soap - water solution
and measured for 1064 nm transmission at
 march2017.jpg2017march.jpg 
  12922   Fri Mar 31 16:10:33 2017 SteveUpdateTreasureLes Guthman Les Guthman interviews  gradstudent
Graig.

Main laser emergency shut off was
  
  12927   Tue Apr 4 11:24:21 2017 SteveUpdatesafetyProjector bulb is out againShipped out for repair.




  
  12930   Thu Apr 6 15:35:44 2017 SteveUpdatePEM envioirmental noiseBuilding:        
Central Engineering Services

     
  
  12931   Fri Apr 7 13:46:23 2017 SteveUpdateSUSETMX enclosure feedthoughETMX enclosure feedtrouh cabeling corrected.  bad.jpggood.jpg 
  12932   Mon Apr 10 09:49:32 2017 SteveUpdateOptical Leversoplev laser RIN test planningWe are planning to test 3 identical 1103Ps
RIN with  continous temp monitoring
and control later.
  
  12933   Mon Apr 10 09:58:35 2017 SteveSummarySUSoplev laser summary updated 




  
  12941   Thu Apr 13 09:48:37 2017 SteveUpdateSUSITMY-UL and ETMX sensorsWhy ITMY UL can not see this earth quake?
SRM and PRM are misaligned. ETMX is still
not well.
 ITMY.pngITMY-UL.pngETMX?.png 
  12953   Thu Apr 27 17:55:33 2017 SteveUpdateCameraswhich camera to use for IR scatterring picturesYesterday I failed to take good pictures
of ETMY  resonant arm of 1064 nm with
Cannon Rebel T3i in RAW 22-27Mp & JPG
 P4270081RAWolym.jpgImg0344.jpg 
  12961   Mon May 1 17:14:58 2017 SteveUpdateCamerasETMY & MC2 ccd cameras removedMC2 ccd camera is replaced by Olympus 570
zoom temporarly.

So as the ETMY ccd camera is replaced
  
  12964   Wed May 3 16:02:36 2017 SteveUpdateGeneralPI pzt inventory checkOne is broken, two are ready to steer green
and 3 available in un known condition

 
 IMG_3678.JPGPIpztETMYgreen.jpg 
  12970   Thu May 4 08:00:54 2017 SteveUpdatesafetysafety trainingFreshmen Rebecca Zhang as " work study
undergrad "  received 40m specific
basic safety training yesterday.
  
  12973   Fri May 5 08:41:42 2017 SteveUpdateCamerasMC2 resonant picturesOlympus SP570 UZ - without  IR blocker,
set up as Atm.3  Camera distance to
MC  face ~85 cm,  IOO-MC_TRANS_SUM
 P5040028MC2c.jpgIMG_3682.JPGIMG_3688.JPG 
  12978   Tue May 9 15:23:12 2017 SteveConfigurationComputerscatastrophic multiple monitor failuresGautam and Steve,

Surge
protective power strip was install on
 Trip-Lite.jpg 
  12994   Tue May 16 16:16:16 2017 SteveUpdatesafetysafety training Early surfs of India Jigyasa and
Kaustubh received basic 40m specific safety
traning.
 surfs2017.jpg 
  12995   Wed May 17 08:19:59 2017 SteveUpdateSUS4.1M earthquake Sus dampings recovered. ETMY oplev needs
to be recentered.

 eq_4.1_SantaBarbara.png4.1m_Isla_Vista_CA.png 
  12996   Wed May 17 11:10:31 2017 SteveUpdateCamerasMC2 CCD video camera back in placeOlympus camera is removed and our old CCD
camera is back to monitor the face of MC2

  
  13008   Tue May 23 16:33:00 2017 SteveUpdateOptical LeversBeam Profiling Results You may compare your results with this.

RXA: please no, that's not
the right way
  
  13018   Tue May 30 13:36:58 2017 SteveUpdateOptical LeversETMY Oplev HeNe is replacedFinally I reallized what is killing the
ETMY oplev laser. Wrong 
power supply, it  was driving the
 oplevETMY120d.png 
  13030   Thu Jun 1 16:21:55 2017 SteveUpdateSUS wire standoffs updateRuby
wire standoff received from China. I
looked one of them with our small USB camera. 
  
  13039   Mon Jun 5 10:30:45 2017 SteveUpdateSUSruby wire standoff picturesAtm 1 & 5, showing the ruby R ~10 mm
as it is seated on Al SOS test mass

Atm. 2, 3 & 4  chipped
 A087_R.png.bmpA097_chipped_edges.png.bmpA099_cal_wire.png.bmpA101_cal_wire_43_micron.png.bmpAl_SOS_R39mm.jpg 
ELOG V3.1.3-