  9194   Thu Oct 3 08:57:00 2013 jamieUpdateComputer Scripts / Programspianosa can't find Jamie PPA

    

       
            
  
  9193   Thu Oct 3 02:51:26 2013 JenneUpdateLSCPRMI locked "forever", some ALS fiddlingFirst up for me this evening was getting
the PRMI locked.
I used the IFO configure screen to
 PRMI_lock_ASSatBeginningAndEnd.png 
  9192   Thu Oct 3 02:46:58 2013 ranaMetaphysicsPEMUSGS Furlough   ObamaCare_GOP.png 
  9191   Thu Oct 3 02:43:34 2013 rana, jenneSummaryLSCPRMI: comparison of 1f and 3f signals w/ calibrationThe attached plot shows the spectra of
all the REFL signals with the PRMI SB lock.
We excited the ITMY_LSC with 3000
 REFL_signals_CalLinesLinedUp.pdf 
  9190   Thu Oct 3 01:24:31 2013 Jenne, RanaUpdateIOOPMC The PMC transmission was around 0.78 all
day, rather than the usual 0.83ish. 
Rana went out to the PSL table and fixed
 PMCR_1064822387.bmppmc80.png 
  9189   Thu Oct 3 01:18:57 2013 KojiHowToLSCsteps to full IFOI vote on PRMI+1arm -> PRFPMI   
  9188   Thu Oct 3 01:06:48 2013 rana, jenneUpdateSUSoplev XY-plots reflect new calibrationAs another proof that sometime is ill with
ETMX Optical Lever:
We scanned the ETMX bias in PIT using
 etmx_ol.png 
  9187   Thu Oct 3 00:01:59 2013 rana, jenneHowToLSCsteps to full IFOIn moving now to full  front_matrix.jpg 
  9186   Wed Oct 2 23:21:54 2013 ranaUpdateComputer Scripts / Programspianosa can't find Jamie PPAMessage on 'pianosa':
Failed to fetch http://ppa.launchpad.net/drgraefy/nds2-client/ubuntu/dists/lucid/main/binary-amd64/Packages.gz 
404  Not Found
  
  9185   Wed Oct 2 14:25:39 2013 SteveUpdateVACvertex crane is still out of order 
The smoke alarms were turned off
and surrounding areas were covered with plastic.
 grindingIbeam.jpgcableMoved.jpg500lbs@end.jpg 
  9184   Tue Oct 1 19:42:19 2013 ranaSummaryCDSmegatron upgradeMax and
I started upgrading megatron to Ubuntu 12.NN
today. We were having some troubles
  
  9183   Tue Oct 1 17:14:53 2013 masayukiUpdateGreen LockingALS servo filters modified 
 [Manasa, Masayuki]
 OLTF.pdffilter_change.pdf 
  9182   Tue Oct 1 14:12:22 2013 ranaSummaryCDSsvndumpfilter on linux1 makes NFS slow Yesterday and this morning's slow
NFS disk access was caused by 'svndumpfilter'
being run at linux1 to carve out the Noise
  
  9181   Tue Oct 1 11:24:02 2013 ranaUpdatePEMparticle counts Probably more important is to establish
quantitatively how particle counts affects
the lock acquisition or noise in the interferometer.
 pepelepew.jpg 
  9180   Tue Oct 1 10:06:27 2013 SteveUpdatePEMparticle countsHow can we improve the  3xJuly4Cal.pngwhichOne.jpg 
  9179   Tue Oct 1 09:51:10 2013 ranaUpdateGreen LockingALS autolocker flowchart  I think we can use the IMC
autolocker to start with getting this started.
Once Jamie fixes the NDSSERVER environment
  
  9178   Mon Sep 30 23:56:19 2013 manasaUpdateGreen LockingALS autolocker flowchart[Masayuki, Manasa] 
Flowchart for ALS autolocker. The
error signal thresholds will be decided by
 ALSautolocker.png 
  9176   Mon Sep 30 17:55:45 2013 manasaUpdateGreen LockingX and Y arm transmission needs to be decoupled[Masayuki, Manasa]
Problem
We wanted to lock both the arms using
 scan2.png 
  9175   Mon Sep 30 13:02:51 2013 Masayuki,ManasaUpdateIOOPMC and MC alignment[Manasa, Masayuki]
The MC lost lock around 8+hrs ago.
The transmission from PMC was 0.77 this morning,
  
  9174   Mon Sep 30 11:33:15 2013 ranaUpdateLSCLSC calibration screen

    

       
            
  
  9173   Mon Sep 30 08:53:22 2013 SteveUpdateVACvertex crane repair schedule has changed

    

       
            
  
  9172   Fri Sep 27 21:01:50 2013 MasayukiUpdateLSCLSC calibration screen 
 I fixed the XARM and YARM real
time calibration servo.
  
  9171   Fri Sep 27 20:28:10 2013 manasaUpdateGreen LockingALS servo[Masayuki, Manasa]
I. ALS servo loops
After fixing things with the phase
 OLTF.pdfphase_badget_xarm_ALS.pdf 
  9170   Fri Sep 27 16:02:23 2013 manasaUpdateGreen LockingY arm ALS phase tracking loop gain changed[Masayuki, Manasa]
While trying to lock the arms using
ALS we found that the locks were not very
 outofloop.pdfPTX_OLTF.pdfYPT_OLTF_after1.pdfYPT_OLTF_before.pdf 
  9169   Fri Sep 27 13:55:11 2013 MasayukiUpdateLSCLSC calibration screen  I added the DAQ channel to
all output of calibration servo. The name
of channels are C1CAL_(plant name)_W_OUT_DQ.
  
  9168   Fri Sep 27 00:48:53 2013 MasayukiUpdateLSCFPMI noise caused by ARM locking

    

       
            
 phase_badget.pngFPMI_noises.png 
  9167   Thu Sep 26 23:02:40 2013 ranaUpdateLSCFPMI noise caused by ARM lockingHidden in Nakano-kun's previous entries
was that the phase margin of the X-Arm was
only 9 degrees!! This extremely close to
 Xarm_sweep_130926.pdflsc.pdferr.png 
  9166   Thu Sep 26 21:55:08 2013 ranaUpdateSUSProblems with ETMY Optical LeverNot so fast! We need to plan ahead of time
so that we don't have to repeat this ETMY
layout another dozen times. Please don't
  
  9165   Thu Sep 26 11:00:51 2013 SteveUpdateSUSProblems with ETMY Optical LeverWe are out of JDSU-Uniphase 1103P heads.
I'm ordering some right now. I'm planning
to make some corrections on Rana's list tomorrow
  
  9164   Thu Sep 26 10:55:29 2013 SteveUpdateGeneralY-arm floor space for testLiyuon will set up a  ~5 mW He/Ne
laser for  waist measurement
  
  9163   Thu Sep 26 01:49:28 2013 MasayukiSummaryGreen LockingFPMI noise caused by ARM locking 
 Measurement
 MICH_OLTF.pdfBS-RS55Q.pngETMX-RS55.pngETMY-RS55.pngplot.pdf 
  9162   Wed Sep 25 23:59:29 2013 MasayukiSummaryGreen LockingFPMI noise caused by ARM locking 
Measurement
 XARM_OLTF.pdfYARM_OLTF.pdfXARM_ITMXresponse.pngYARM_ITMYresponse.pngfree_running.pdf 
  9161   Wed Sep 25 23:15:11 2013 MasayukiSummaryGreen LockingFPMI noise caused by ARM lockingI measured some error signal, OLTFs and
responses for FPMI noise estimation. Especially
we are interested in the noise from in-loop
 fpmibd.pdf 
  9160   Wed Sep 25 19:34:51 2013 ranaUpdateSUSProblems with ETMY Optical LeverI went down to investigate the issue with
the extra noise that I found in the ETMY
optical lever yesterday. There were several
 ETMY-BadHeNe.pdf 
  9159   Wed Sep 25 17:07:08 2013 ranaFrogsTreasureFree Green Mango Juice in fridge   aam_pana_recipe.jpg 
  9158   Wed Sep 25 08:11:01 2013 MasayukiSummaryLSCLSC calibration screen 
  
 plot.pdfScreenshot.pngScreenshot-1.pngfringe.pdf 
  9157   Tue Sep 24 22:19:57 2013 ManasaUpdateGeneralFPMI locked [Masayuki, Manasa]
We locked FPMI and measured the FPMI
noise (power spectrum of error signal - MICH_IN1)
  
  9156   Tue Sep 24 20:43:45 2013 masayukiSummarySUSoptical levers centeringI centered optical levers of ITMX,BS,ETMY.
I also change the position of optical levers
of ITMX, ETMY, ITMY, BS on Friday night(9/21),
 Screenshot-Untitled_Window.pngScreenshot-Untitled_Window-1.png 
  9155   Tue Sep 24 10:55:45 2013 ranaUpdatePSLPMC re-alignedAfter relocking the PMC at a good voltage,
Steve and I re-aligned the beam into the
PMC by walking the last two steering mirrors.
 psl-trend.png 
  9154   Sun Sep 22 23:04:52 2013 ranaUpdatePEMGuralp needs recentering After seeing all of these spikes
in the BLRMS at high frequency for awhile,
I power cycled the Guralp interface box (@
 seis.pdf 
  9153   Sun Sep 22 22:54:28 2013 ranaUpdateIOOmode cleaner not lockingHaving trouble again, starting around 1
hour ago. No one in the VEA. Adjusted the
offset -seems to be OK again.
  
  9152   Sun Sep 22 22:05:10 2013 ranaUpdateSUSoplev XY-plots reflect new calibrationThe ETMX oplev signal looks kind of dead
compared to the ETMY. It has no features
in the spectra and the SUM is pretty low.
 noise.png 
  9151   Sun Sep 22 21:28:53 2013 ranaUpdateSUSset OL T RAMP values (they are not visible on the OL screens)controls@rosalba:/opt/rtcds/caltech/c1/scripts/SUS
0$ ./setOLtramps 
Old : C1:SUS-ETMX_OLPIT_TRAMP       
  
  9150   Sun Sep 22 21:03:15 2013 ranaConfigurationSUSTuned bounce and roll mode of ETMY suspension Today I noticed that there was a
lot of noise at the Bounce and Roll eigenfrequencies
for ETMY. I found that the bandstop filter
 etmy-error.pngnotches.pdf 
  9149   Fri Sep 20 22:49:10 2013 MasayukiUpdateLSCLSC calibration screen

    

       
            
 plot.pdf 
  9148   Fri Sep 20 20:27:18 2013 ranaUpdateIOOmode cleaner not locking I used our procedure from this
entry to set the IMC board offset as
well as the FSS board offset.
  
  9147   Fri Sep 20 20:14:52 2013 ranaSummaryGeneral/home/cds nearly full

    

       
            
  
  9146   Fri Sep 20 16:37:30 2013 SteveUpdateVACvertex crane folding arm is back on

    

       
            
 bushingBottom.jpgfoldingI.jpgnoLoadGap.jpgtrollyway.jpgtrollySee.jpg 
  9145   Fri Sep 20 09:49:06 2013 SteveUpdateSUSOptical Lever Trend for 180 days: bad ETMY & PRMI'm working on it.  ETMYoplevPRM.png 
  9144   Fri Sep 20 08:15:30 2013 SteveUpdateComputer Scripts / ProgramsOttavia, Rossa and PianosaOttavia, Rossa  and Pianosa are running
out of storage  space.
 Ottavia.pngRossa.pngPianosa.png 
ELOG V3.1.3-