40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 161 of 341  Not logged in ELOG logo
ID Date Authorup Type Category Subject Text Attachments
  12913   Tue Mar 28 16:47:40 2017 SteveUpdatesafetyProjector bulb is out againThree replacement
bulbs ordered

Rana can discribe
  
  12915   Wed Mar 29 09:24:28 2017 SteveUpdateloresummery pagesThe summery pages are working at a slow
motion speed. It's response time 12 minutes.
  
  12917   Wed Mar 29 16:38:00 2017 SteveOmnistructureTreasuresus fiber illluminated   fiber.jpg 
  12921   Fri Mar 31 10:16:07 2017 SteveUpdatesafetylaser safety glasses annual inspectionLaser safety glasses cleaned in "
Dawn Ultra " mild soap - water solution
and measured for 1064 nm transmission at
 march2017.jpg2017march.jpg 
  12922   Fri Mar 31 16:10:33 2017 SteveUpdateTreasureLes Guthman Les Guthman interviews  gradstudent
Graig.

Main laser emergency shut off was
  
  12927   Tue Apr 4 11:24:21 2017 SteveUpdatesafetyProjector bulb is out againShipped out for repair.




  
  12930   Thu Apr 6 15:35:44 2017 SteveUpdatePEM envioirmental noiseBuilding:        
Central Engineering Services

     
  
  12931   Fri Apr 7 13:46:23 2017 SteveUpdateSUSETMX enclosure feedthoughETMX enclosure feedtrouh cabeling corrected.  bad.jpggood.jpg 
  12932   Mon Apr 10 09:49:32 2017 SteveUpdateOptical Leversoplev laser RIN test planningWe are planning to test 3 identical 1103Ps
RIN with  continous temp monitoring
and control later.
  
  12933   Mon Apr 10 09:58:35 2017 SteveSummarySUSoplev laser summary updated 




  
  12941   Thu Apr 13 09:48:37 2017 SteveUpdateSUSITMY-UL and ETMX sensorsWhy ITMY UL can not see this earth quake?
SRM and PRM are misaligned. ETMX is still
not well.
 ITMY.pngITMY-UL.pngETMX?.png 
  12953   Thu Apr 27 17:55:33 2017 SteveUpdateCameraswhich camera to use for IR scatterring picturesYesterday I failed to take good pictures
of ETMY  resonant arm of 1064 nm with
Cannon Rebel T3i in RAW 22-27Mp & JPG
 P4270081RAWolym.jpgImg0344.jpg 
  12961   Mon May 1 17:14:58 2017 SteveUpdateCamerasETMY & MC2 ccd cameras removedMC2 ccd camera is replaced by Olympus 570
zoom temporarly.

So as the ETMY ccd camera is replaced
  
  12964   Wed May 3 16:02:36 2017 SteveUpdateGeneralPI pzt inventory checkOne is broken, two are ready to steer green
and 3 available in un known condition

 
 IMG_3678.JPGPIpztETMYgreen.jpg 
  12970   Thu May 4 08:00:54 2017 SteveUpdatesafetysafety trainingFreshmen Rebecca Zhang as " work study
undergrad "  received 40m specific
basic safety training yesterday.
  
  12973   Fri May 5 08:41:42 2017 SteveUpdateCamerasMC2 resonant picturesOlympus SP570 UZ - without  IR blocker,
set up as Atm.3  Camera distance to
MC  face ~85 cm,  IOO-MC_TRANS_SUM
 P5040028MC2c.jpgIMG_3682.JPGIMG_3688.JPG 
  12978   Tue May 9 15:23:12 2017 SteveConfigurationComputerscatastrophic multiple monitor failuresGautam and Steve,

Surge
protective power strip was install on
 Trip-Lite.jpg 
  12994   Tue May 16 16:16:16 2017 SteveUpdatesafetysafety training Early surfs of India Jigyasa and
Kaustubh received basic 40m specific safety
traning.
 surfs2017.jpg 
  12995   Wed May 17 08:19:59 2017 SteveUpdateSUS4.1M earthquake Sus dampings recovered. ETMY oplev needs
to be recentered.

 eq_4.1_SantaBarbara.png4.1m_Isla_Vista_CA.png 
  12996   Wed May 17 11:10:31 2017 SteveUpdateCamerasMC2 CCD video camera back in placeOlympus camera is removed and our old CCD
camera is back to monitor the face of MC2

  
  13008   Tue May 23 16:33:00 2017 SteveUpdateOptical LeversBeam Profiling Results You may compare your results with this.

RXA: please no, that's not
the right way
  
  13018   Tue May 30 13:36:58 2017 SteveUpdateOptical LeversETMY Oplev HeNe is replacedFinally I reallized what is killing the
ETMY oplev laser. Wrong 
power supply, it  was driving the
 oplevETMY120d.png 
  13030   Thu Jun 1 16:21:55 2017 SteveUpdateSUS wire standoffs updateRuby
wire standoff received from China. I
looked one of them with our small USB camera. 
  
  13039   Mon Jun 5 10:30:45 2017 SteveUpdateSUSruby wire standoff picturesAtm 1 & 5, showing the ruby R ~10 mm
as it is seated on Al SOS test mass

Atm. 2, 3 & 4  chipped
 A087_R.png.bmpA097_chipped_edges.png.bmpA099_cal_wire.png.bmpA101_cal_wire_43_micron.png.bmpAl_SOS_R39mm.jpg 
  13045   Tue Jun 6 09:14:26 2017 SteveUpdateCamerasGigE installation at MC250mm
1.8 lens with
Basler camera at MC2 face with micro
 MC2.jpg 
  13046   Wed Jun 7 10:07:00 2017 SteveUpdatePEMair condition thermostateThe Y arm ac thermostate was calibrated
after cooling water relay replacement by
Mike.... yesterday. The set temp is remaind
  
  13047   Wed Jun 7 11:32:56 2017 SteveUpdateVACsmooth vac rebootGautam and Steve,

 

The medm monitor & vac control
 vac_reboot.png 
  13049   Wed Jun 7 14:27:23 2017 SteveUpdateSummary Pagessummery pages not workingLast good page May 18, 2017

Not found, error message May 19
- June 4,2017
  
  13050   Wed Jun 7 15:41:51 2017 SteveUpdateComputerswindow laptop scannedRandy Trudeau scanned our Window laptop
Dell 13" Vostro and Steve's memory
stick for virus. Nothing was found. The search
  
  13054   Fri Jun 9 09:13:26 2017 SteveUpdateCamerasGigE camera lens with AR We should move on with getting this
lens from Edmonds #67-717  at 1064
R<3% 
 coating_curve.pdf 
  13062   Tue Jun 13 08:40:32 2017 SteveUpdateIMCIMC wonkinessHappy MC after last glitch at 10:28 so
the credit goes to Rana

 happy_MC.pnglast_glitch.png 
  13074   Tue Jun 20 14:58:08 2017 SteveUpdateCamerasGigE camera at ETMXGigE can be connected to ethernet. AR coated
1064 f50 can arrive any day now.

 ETMXgige.jpg 
  13075   Tue Jun 20 16:28:23 2017 SteveUpdateVACRGA scan   RGAscan243d.pngRGAscan.png 
  13095   Wed Jul 5 10:23:18 2017 SteveUpdatesafetyliquid nitrogen boil offThe liquid nitrogen container has a pressure
releif valve set to 35 PSI  This valve
will open periodically when contains LN2
 liqued_nitrogen_boil_off.jpg 
  13099   Fri Jul 7 09:03:40 2017 SteveSummaryHistoryas it was in 1994
 
 1994.PDF 
  13123   Mon Jul 17 16:22:01 2017 SteveUpdateSUSruby wire standoff picturesBluebean Optical Tech Limited of Shanghai
delivered 50 pieces red ruby
prisms
 contacting_ridge.bmpcontacting_ridge.png 
  13126   Wed Jul 19 12:47:43 2017 SteveSummarySUSoplev laser summary updated1103P, sn P893518 of  2013 vintage
is dead at the sus  fiber demo

  
  13129   Fri Jul 21 08:05:07 2017 SteveSummarySUSred, blue, green laser diodes orderedAlso ordered 1 ea.

Blue
20mW
  
  13134   Mon Jul 24 09:55:29 2017 SteveOmnistructureVACcontroller failerIfo pressure was 5.5 mTorr this Monday
morning. The PSL shutter was still open.
TP2 controller failed. Interlock closed V1,
 TP2controllerFails.png 
  13142   Tue Jul 25 08:48:57 2017 SteveUpdateVACRGA scan at d278The RGA did not shut down at the turbo
pump controller failing.

 RGA278d.png 
  13143   Tue Jul 25 14:04:06 2017 SteveUpdateVACturbo controller installed and we are running at vac normalGautam and Steve,

Spare Varian turbo-V 70 controller,
Model 969-9505, sn 21612 was swapped in.
 TP2@75Krpm.png 
  13144   Tue Jul 25 14:27:19 2017 SteveUpdatesafetysafety trainingKira Dubrovina and Naomi Wharton received
40m specific basic safety training.
 safety.jpg 
  13158   Wed Aug 2 09:40:55 2017 SteveUpdateElectronicsspare ILIGO electronicsSpare ILIGO electronics temporarly stored
in the east arm. We need cabinet space.
 iLIGOspares.jpgspareIligo.jpg 
  13171   Tue Aug 8 17:04:26 2017 SteveUpdateVACunintended pump downIFO pressure 2 Torr,    PSL 
shutter closed.  I'm pumping down
with 2 roughing pumps with ion pump gate
 pumping_down.png 
  13172   Tue Aug 8 17:44:11 2017 SteveUpdateVACunintended pump downPumpdown stopped for over night  at
~  1 Torr

The roughing line disconnected. 
 stopped_pumping.png 
  13175   Wed Aug 9 11:59:51 2017 SteveUpdateVACunintended pump down at vacuum normalpd80b has reached Vac Normal. IFO pressure
0.5 mTorr

We need our vauum channels back
 pdc.pngpd80b@vacnormal.png 
  13182   Thu Aug 10 09:31:57 2017 SteveUpdateSUSITMX sensor voltageThere must be some bad connection




 9daysITMX.pngvacGlitchITMX.png 
  13186   Thu Aug 10 15:45:34 2017 SteveUpdateVACaccidental vent to 17 TorrFinally we got the cold cathode gauge working.
IFO pressure 7e-6 Torr-it, vacuum normal
valve configuration with all 4 ion pump gate
 Mag_UPS.jpgUPSbatteryPack.jpgclosing_V1.jpg 
  13208   Tue Aug 15 08:22:16 2017 SteveUpdateGeneralprojector light bulb replacedBL-FS300C-PH-LE was
replaced after 2,904 hrs  It did
not explode this time.  The 4 monts
  
  13213   Wed Aug 16 14:57:01 2017 SteveUpdatePSLref Cavity heating blanket power supplyThe last entry I found relating to ref
cavity was
2011 Aug 19
 refCavPSheat.jpgrefCavTempSens.jpgrefTempSen_1X1.jpg 
ELOG V3.1.3-