40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 160 of 341  Not logged in ELOG logo
ID Date Author Type Category Subject Text Attachments
  9119   Tue Sep 10 09:18:22 2013 SteveUpdateVACdry pump is getting loud 
 TP3 foreline's dry pump is
getting noisier and noisier.  Turbo
  
  9118   Mon Sep 9 20:46:28 2013 MasayukiUpdateLSCMICH calbration[Manasa, Masayuki]
We took a bunch of measurements.
Transfer function and power spectrum using
  
  9117   Mon Sep 9 15:33:06 2013 SteveUpdateVACvertex crane repair is scheduled

    

       
            
  
  9116   Fri Sep 6 23:01:08 2013 KojiUpdateLSCStable DRMI lock was recovered from the impact on the RF system modificationSummary
 DRMI.pngSensMat_PRMI_1000cts_580Hz_2013-08-26_235635.pngSensMat_PRMI_1000cts_580Hz_2013-09-06_201137.png 
  9115   Fri Sep 6 09:27:10 2013 SteveUpdateVAC31 days after pumpdown

    

       
            
 day31vac.png 
  9114   Thu Sep 5 21:07:09 2013 JenneUpdateLSCStarted work on logic for triggeringI want something like an "AND"
for the degree of freedom triggers. 
Koji and I talked through an idea, and I
  
  9113   Thu Sep 5 15:18:41 2013 JenneUpdateLSCFree swinging DRMI power buildupsI have the DRMI free swinging right now,
since it's not really locking.  Looking
at these time series in the attached pdf,
 DRMI_free_swing_power_buildups.pdf 
  9112   Thu Sep 5 11:19:33 2013 JenneUpdateSUSPRM side

    

       
            
  
  9111   Thu Sep 5 10:47:58 2013 SteveUpdateVACvertex crane folding issue 
 [Fred Goldbar, Mike Gerfen,
Dennis Coyne and Steve]
 5mmLess.jpg 
  9110   Thu Sep 5 10:28:17 2013 SteveUpdateSUSPRM side I think the crane repair guy accidentally 
stepped on the  BSC support beam.
PRM side is not coming down.
 craneguywashere.png 
  9109   Thu Sep 5 01:55:29 2013 JenneUpdateLSCLSC model upated to have AS110 channels, violin filter triggeringI have
modified the c1lsc model so that I have access
to the AS110 channels in the triggering and
  
  9108   Thu Sep 5 00:40:33 2013 ranaUpdateSUSMC2 tickler turned OFF 
 You're right - down turns it
on. Still, the fact that the same tickle
  
  9107   Wed Sep 4 22:14:35 2013 JenneUpdateSUSMC2 tickler turned OFF

    

       
            
  
  9106   Wed Sep 4 21:44:54 2013 Not JenneUpdateElectronicsRF distribution box: ReinstalledTemporary fix for the switch: give a bit
of oil to the button
Permanent fix: buy better switches.
  
  9105   Wed Sep 4 20:47:15 2013 manasaUpdateLSCCalibrated in-loop MICH noiseTo estimate in-loop MICH noise:
(a) Calibrate MICH_ERR:
1. Lock the arms for IR using POX11
 MICH_noise.pdf 
  9104   Wed Sep 4 20:39:23 2013 ranaUpdateSUSMC2 tickler turned OFF

    

       
            
  
  9103   Wed Sep 4 17:22:09 2013 JenneUpdateLSCDemod phases for RFPDsI checked the demod phases for AS55, POP110,
and all the REFL PDs. 
AS55:  I locked MICH, and shook
  
  9102   Wed Sep 4 16:08:22 2013 manasaUpdateSUSMC2 tickler turned OFF [Jenne, Manasa]
While we were trying to relock the
MC after Jenne put back the RF box, we found
  
  9101   Wed Sep 4 16:06:40 2013 JenneUpdateElectronicsRF distribution box: ReinstalledI have reinstalled the RF distribution
box, as well put in the AS110 demod board. 
I plugged everything back in, and turned
  
  9100   Tue Sep 3 21:10:36 2013 JenneConfigurationElectronicsputting together a 110 MHz LSC demod board for AS

    

       
            
  
  9099   Tue Sep 3 21:08:13 2013 JenneUpdateElectronicsRF distribution box: 110 MHz LO optionsThe RF distribution box is still on the
bench, so again, don't
  
  9098   Tue Sep 3 14:23:21 2013 SteveUpdatePEM earthquakes ~Vancuver, Canada earthquakes: magnitude
6,  5  and more shaking
 
 EQm6&5.png 
  9097   Tue Sep 3 10:54:33 2013 SteveHowToGeneralHow To Coil Cables

    

       
            
  
  9096   Mon Sep 2 18:06:21 2013 JenneUpdateElectronicsRF distribution box: 110 MHz LO optionsAfter scrounging for parts, and opening
up the box, I have modified my proposal to
the following:
 RF_distribution_box_proposed_modifications.pdf0902131751.jpg0902131751a.jpg 
  9095   Mon Sep 2 16:46:32 2013 JenneUpdateElectronicsRF distribution box is on the benchI have pulled the RF distribution box out
of the rack, so I can look at it, and modify
it to have 2 110 MHz spigots. I'm going to
  
  9094   Mon Sep 2 15:22:57 2013 JenneUpdatePSLPMC relocked The PMC was locked on an LG 10 mode
(or something like it), for at least the
last 8 hours.  I relocked it on the
  
  9093   Mon Sep 2 03:51:14 2013 ranaHowToGeneralHow To Coil Cables http://youtu.be/pEd7ru24Vx0   
  9092   Fri Aug 30 14:31:57 2013 SteveUpdateGeneralcleaning upI cleaned up around MC2 and 1Y1 area this
morning.
ETMY NPRO moved from the side to
 MC2areaCP.jpg1Y1areaCleanedUp.jpgETMY_NPROmoved.jpg 
  9091   Fri Aug 30 11:00:46 2013 ManasaUpdateGeneralSeries of earthquakesThere has been a series of earthquakes  Screenshot-Earthquakes_-_Mozilla_Firefox.pngSUSnSEIS.png 
  9090   Fri Aug 30 08:08:29 2013 steveUpdatesafetyfire horns-flashers tested OK 
 We had fire alarm tests
 and evacuation drills at 1:30pm yesterday.
  
  9089   Fri Aug 30 01:01:28 2013 rana, nicSummaryComputer Scripts / ProgramsaLIGO Noise Budget code installed and runningChris Wipf has been developing a new Noise
Budget code that allows us to use our existing
Simulink models to handle all of the noise
 NBplots.pngScreen_Shot_2013-08-30_at_1.00.02_AM.png 
  9088   Thu Aug 29 17:25:50 2013 JamieUpdateSUSSUS medm screen upgradeRana asked me to look at the SUS MEDM screen
upgrade situation, and provide an upgrade
prescription.  Unfortunately there not
  
  9087   Wed Aug 28 23:09:55 2013 jamieConfigurationCDScode to generate host IPC graph   hosts.png40m-ipcs-graph.py 
  9086   Wed Aug 28 19:47:28 2013 jamieConfigurationCDSfront end IPC configuration

    

       
            
  
  9085   Wed Aug 28 15:41:42 2013 SteveUpdateVACRGA scan at day 23 Valve configuration: Vacuum Normal
pd76-m-d23
 
 pd75md23.png 
  9084   Wed Aug 28 11:23:41 2013 SteveUpdateVACcrane repair sheduled

    

       
            
  
  9083   Wed Aug 28 11:15:02 2013 SteveUpdateGreen LockingXend green layout corrections

    

       
            
  
  9082   Wed Aug 28 07:33:51 2013 manasaUpdateLSCMICH lockingI wanted to measure the OLTF of MICH.
What I did:
1. Ran LSC offsets script to zero
 MICH.pdf 
  9081   Wed Aug 28 06:26:28 2013 manasaUpdateComputer Scripts / ProgramsASS req and snap files edited[From yesterday] ASS for X arm was behaving
slightly funny over the last couple of days.
ASS could not correct the BS misalignment.
  
  9080   Wed Aug 28 06:17:15 2013 manasaUpdateComputer Scripts / Programsalias for MATLAB2010Although Matlab 2013 has not been causing
any visible trouble so far, it takes a while
to startup.
  
  9079   Wed Aug 28 05:21:58 2013 manasaUpdateCDSCDS svn commits not happeningI am responsible for missed
svn commits with als and asx. I have committed them.
  
  9078   Wed Aug 28 03:28:00 2013 JenneUpdateLSCPlaying with DRMI, some ASS automation prep[Rana, Jenne]
We did lots of poking around with
the DRMI tonight.  I should elog more
  
  9077   Wed Aug 28 00:41:23 2013 JenneUpdateCDSCDS svn commits not happeningsvn status update. asx, als and ioo
were found not committed. Not sure about who modified
  
  9076   Tue Aug 27 20:43:34 2013 KojiConfigurationCDSfront end IPC configurationThe reason we had the PCIe/RFM system was
to test this mixed configuration in prior
to the actual implementation at the sites.
  
  9075   Tue Aug 27 19:50:06 2013 JamieConfigurationComputer Scripts / Programscdsutils checked out into /opt/rtcdsI have checked out the new cdsutils
repository at:

/opt/rtcds/cdsutils/release

This
  
  9074   Tue Aug 27 19:34:36 2013 JamieConfigurationCDSfront end IPC configurationSo the IPC situation on the front end network
is not so great right now.  For various
no-longer-valid reasons, c1lsc had no RFM
 hosts.png 
  9073   Tue Aug 27 18:58:52 2013 KojiConfigurationElectronics110 MHz LO options- Do we have an appropriate amplifier?
- True challenge could be to find
a feedthrough for the new port. (or to find
  
  9072   Tue Aug 27 18:21:35 2013 JenneConfigurationElectronics110 MHz LO optionsAs I see it, we have a few options for
getting the 110 MHz LO to both the POP110
and AS110 demod boards.  
  
  9071   Tue Aug 27 17:32:52 2013 JenneConfigurationElectronicsputting together a 110 MHz LSC demod board for ASI measured the phase split between the
I and Q signals of my AS110 board. 
To do so, I plugged the board into an empty
  
  9070   Tue Aug 27 15:44:08 2013 manasaUpdateCDSIssues with ALS fixedI figured out the problem with ALS from
yesterday. While the model was just fine,
the medm screens were not checked if they
  
ELOG V3.1.3-