Entry  Sat Jul 26 15:09:57 2008, Aidan, Update, Computers, Reboot of op440m 

I was reviewing the PSL Overview screen this afternoon and op440m completely froze when I center-clicked on the REF CAVITY TRANSMISSION indicator. It was
unresponsive to any keyboard or mouse control. The moon button had no effect to shut the machine down.
Entry  Fri Jul 25 19:57:18 2008, Jenne, Update, PSL, Ref Cav & PMC 
"PMC is in, but is still being worked on.  Leave it alone." ---Rana

Ref. Cavity is locked again.  Still a work in progress.  I think we're ready to mode match on Monday.  ---Jenne
Entry  Fri Jul 25 17:32:46 2008, Sharon, Update, , ASS computer 
So, it seems a bit too complicated getting the coefficients the way I wanted it to happen (simulink-.ini...). 
I returned everything to the way it was and it's all working. The new plan is to choose the specific channel I want to find its instantanous coefficients,
let the adaptive code run for a while, setting mu and tau to zero (freezing the coefficients), and exciting the noise signal channel taking the transfer
Entry  Fri Jul 25 13:30:53 2008, Sharon, Update, , Changes in ASS computer 
I editted the simulink diagram of the ASS computer so it now has 2 more channels reading 2 sets of the FIR coefficients to match Alex's changes in the C
code.
The new simulink has already been compiled and can be found in /cvs/cds/caltech/users/alex/cds/advLigo/src/epics/simLink/ass.mdl
Entry  Thu Jul 24 21:53:00 2008, rana, Summary, Treasure, High School Tour group and the PMC 
There was a tour today of 40 high school kids. [COLOR=red]I warned them that the lasers could burn out their
eyes[/COLOR], that the vacuum could suck them through the viewports like tubes of spaghetti and that the
high voltage amps would fry their hair off.
Entry  Thu Jul 24 21:04:58 2008, rana, Update, PSL, FSS 
Since Jenne and Yoichi are going to finish up their refcav/FSS work in the morning I decided to
look at the trends. I set the RF modulation level from 10.0 back down to 7.5 so that we would
have the same RF modulation depth as before. I also set the FSS common gain and its nominal to
Entry  Thu Jul 24 19:29:26 2008, Yoichi, Configuration, PSL, C1:PSL-STAT_FSS_NOM_C_GAIN is changed from 30 to -0.7 
Koji, Yoichi

Since the light power going to the ref. cavity is now significantly increased (see Janne's elog later), [CODE]C1:PSL-STAT_FSS_NOM_C_GAIN[/CODE]is changed
Entry  Thu Jul 24 11:49:07 2008, Masha, Summary, Auxiliary locking, belated weekly summary filter_tr_function.pdffiltered_spectr0724.pdf
I designed a high pass filter to whiten the spectrum from the Mach Zehnder to optimize the 
input into the ADC. The swept sine response measurement and the effect of the filter on the
spectrum are attached. If I start using the digital system (it is currently down in Bridge),
Entry  Wed Jul 23 22:34:07 2008, Yoichi, Update, LSC, Arm cavity g-factor measurement 
I tried the same thing as the X-arm to the Y-arm.
I'm puzzled. I found exactly the same behavior as the X-arm in the AS166 demodulated signals, whereas I expected different resonance frequency because
of the arm length difference.
    Reply  Thu Jul 24 01:27:00 2008, Koji, Update, LSC, Arm cavity g-factor measurement 
[quote]I locked the Y-arm and mis-aligned the end mirror in Yaw until the transmission power gets half.
Then I injected a 30Hz sinusoid into the error point of the Y-arm servo to shake the ETMY.
I observed AS166_I and AS166_Q as I changed the 166MHz frequency.
       Reply  Thu Jul 24 02:57:26 2008, rob, Update, LSC, Arm cavity g-factor measurement 
[quote]
So, now I feel that the method for the TEM01 quest should be reconsidered.
          Reply  Thu Jul 24 08:09:26 2008, Yoichi, Update, LSC, Arm cavity g-factor measurement 
[quote]
A-ha! Do you always expect the 30Hz signal, don't you?
Because this is the PDH technique.
Entry  Thu Jul 24 03:08:20 2008, rob, Update, Locking, +f2 DRMI+2ARMS 

rob, john, yoichi
Entry  Thu Mar 13 02:52:06 2008, Lisa, Configuration, LSC, Locking with 3f 
Today we have tried to use the reflected signal demodulated at 3*f1 ~ 99 MHz ([COLOR=chocolate][B]REFL31[/B][/COLOR]) for length control.
This signal is cool because it is generated by the beating of sidebands, so it is not very sensitive to what the carrier does inside the IFO. 
In particular, its gain and the demodulation phase shouldn't change much while changing the CARM offset during the locking sequence.
    Reply  Thu Jul 24 01:04:01 2008, rob, Configuration, LSC, IFR2023A (aka MARCONI) settings 
[quote]

P.S.: We made a test by changing the frequency of the local oscillator by a little bit and then coming back to the original value. We observed that the
Entry  Wed Jul 23 21:48:30 2008, rob, Configuration, General, restore IFO when you're done with it 

[SIZE=3][B]when you are done with the IFO, please click "Restore last auto-alignment"[/B][/SIZE] on the [COLOR=orange]yellow IFO[/COLOR] portion of the
C1IFO_CONFIGURE.adl screen.  Failure to comply will be interpreted as antagonism toward the lock acquisition effort and will be met with excoriation.
Entry  Wed Jul 23 18:42:18 2008, Jenne, Update, PSL, Alignment of AOM 
[Rana, Yoichi, Jenne]

Short Version:  We are selecting the wrong diffracted beam on the 2nd pass through the AOM (we use the 2nd order rather than the first).  This will be
Entry  Wed Jul 23 16:31:02 2008, Alberto, Configuration, Computers, Megatron connected 
Joe, Rana, Alberto,

we found out the password for Megatron so we could log in and set a new one so that now it's the same as that for controls.
    Reply  Wed Jul 23 17:19:48 2008, Alberto, Configuration, Computers, Megatron connected 
We changed the IP address. Ther new one is 131.215.113.95.

Joe, Alberto
Entry  Wed Jul 23 13:52:26 2008, Sharon, Update, , MEDM changes matrix
There is a new MEDM screen now when you go from c1ass>top>pem.
Instead of having 12 "mini filters" screens go to 8 outputs (with the wrong correlation impression from the table), we have a 24X8 matrix.
This matrix is there so you could choose which noise signals you want to send to the adaptive code. When you indicate the number of noise channels you
Entry  Wed Jul 23 12:42:23 2008, Eric, Summary, Cameras, Weekly Summary PMCScanSinglePeak.tifPMCScanWide.tifPMCSlowSinglePeak.tif
I finally got the ezcaPut command working.  The camera code can now talk directly to the EPICS channels.  However, after repeated calls of the ezcaPut function,
the function begins claim to time out, even though it continues to write values to the channel successfully (EPICS is successfully getting the new value
for the channel, but failing to reply back to the program in time, I think).  It has seg-faulted once as well, so the stability cannot yet be trusted for
Entry  Wed Jul 23 10:49:37 2008, Max, Update, Computer Scripts / Programs, Weekly Progress Report 
This week I installed the magnetometer. The channels seem to be reading correctly. I'm back to working on noise budget and have added the MICH and will
soon add the PRC source. The various source-specific scripts still need to be adjusted and the transfer functions remeasured since they do not match in
any reasonable manner the SRD Rana put out in the e-log yesterday. 
Entry  Wed Jul 23 10:47:05 2008, Sharon, Update, , Weekly update 
This week I spent some time with Alex who updated the adaptive code to save the filter's coeffs all the time, stop when I open the loop, and reload the
latest coeffs. when I start it again.
The point was to minimize the adaptation rate. Unfortunately, seems it is making some filters go wild, so it is not in use yet.
Entry  Wed Jul 23 01:42:26 2008, rana, Configuration, PSL, FSS RFPD: Examined, "repaired", and re-installed Untitled.pdf
[U]Rob said that there might be something wrong with the FSS RFPD since the loop gain is so low.[/U]
Next time we should just use the Jenne laser on it in-situ and compare with our reference.
Entry  Tue Jul 22 22:25:31 2008, rana, Update, LSC, Looptickle for existing 40m nb.png
John and I have adapted the Stefan-Looptickle model of the 40m upgrade to have the parameters of the old one.
(old one = what we have had for the last 4 years).
Entry  Tue Jul 22 22:11:58 2008, Yoichi, Update, LSC, X-arm g factor measurement 
Alberto, Yoichi

We measured the g factor of the X-arm by slightly shifting the 166MHz sideband frequency:
Entry  Tue Jul 22 16:50:09 2008, steve, Metaphysics, Environment, professorial clean up of work bench ranaclup.pngcleanup2.png
Atm1: is showing the spiritual satisfaction after work bench clean up by the professor himself.

Atm2: some items are still waiting to be placed back to their location 
Entry  Tue Jul 22 03:03:22 2008, John, Rob, Update, PSL, FSS open loop transfer function 
With the common gain slider maxed out the unity gain frequency is 58kHz.

The reference cavity refl diode appears to be okay. RF OUT/ TEST IN transfer function was normal.
    Reply  Tue Jul 22 13:16:09 2008, John, Rob, Update, PSL, FSS open loop transfer function 
[quote]With the common gain slider maxed out the unity gain frequency is 58kHz.

The reference cavity refl diode appears to be okay. RF OUT/ TEST IN transfer function was normal.
Entry  Tue Jul 22 11:55:22 2008, rana, Update, PSL, Note from R. Abbott re: the PMC 
an email from Rich:
[CODE]Your PZT is broken.
    Reply  Tue Jul 22 13:15:14 2008, rob, Update, PSL, Note from R. Abbott re: the PMC 
[quote]an email from Rich:
[CODE]Your PZT is broken.
Entry  Tue Jul 22 09:24:17 2008, steve, Update, PSL, laser power power120d.jpg
Laser power reality of 120 days
Entry  Mon Jul 21 19:55:16 2008, rana,jenne, Configuration, IOO, Noise in MC_F SCRN0024.GIF
[COLOR=darkgreen]Jenne put the MC board on extender today - its still that way but everything is probably connected (check AO).[/COLOR]

We measured the TFs of the DAQ section for MC_F because of how everything looked wrong in the plots Jenne
Entry  Mon Jul 21 19:48:57 2008, Sharon, Update, , how tp restart C1ASS 
How to restart C1ASS:

1. reboot
Entry  Mon Jul 21 15:52:22 2008, steve, Bureaucracy, SAFETY, fire alarms test 
The fire alarm test and evacuation drill was successfully completed at 13:45 Wednesday, July 16, 2008

Everybody was on time for the 40m meeting.
Entry  Mon Jul 21 14:26:11 2008, Max, Summary, PEM, Added Channels 
The following channels have been added.

Channel Name                DAQ port
Entry  Mon Jul 21 11:54:00 2008, Jenne, Update, General, MC Servo Board 
I pulled the MC Servo Board again, to check the components that are on the board, and compare them with the schematics.  The filters that I'm interested
in on the Fast Path haven't been changed.  The high pass filters on the Fast Path have been changed.
Entry  Mon Jul 21 10:00:42 2008, steve, Update, PEM, ifo room temp temp5y.jpg
Five years of temp trend with 5 C fluctuation. The campus chilled water supply was upgraded ~ 1 year ago.

I requested our thermostats to be calibrated.
Entry  Mon Jul 21 09:52:05 2008, Sharon, Update, , Adaptive code changes 
Thanks to Alex, we now save the coefficients of the adaptive filter every cycle. When we choose ENABLE: OFF on the MEDM screen, suppressing the signal to
the MC1, we stop and save the last coefficients. When enabling it again, it starts from the last coefficients saved. I will take some measurements today
to check how this contributes to the adaptation rate. If you change the number of taps or the number of AUX channels, the coefficients are again set to
Entry  Sat Jul 19 19:41:56 2008, Yoichi, AoG, PSL, The author of the entry 702 is Yoichi not Rob 
I made a mistake.
Entry  Fri Jul 18 19:41:09 2008, Yoichi, Update, PSL, PMC PZT investigation Hysteresis.pngStepResponse.png
I measured the HV coming to the PMC PZT by plugging it off from the PZT and hooking it up to a DVM.
The reading of DVM is pretty much consistent with the reading on EPICS. I got 287V on the DVM when the EPICS says 290V.
    Reply  Fri Jul 18 23:24:24 2008, rob, Update, PSL, PMC PZT investigation 
[quote]I measured the HV coming to the PMC PZT by plugging it off from the PZT and hooking it up to a DVM.
The reading of DVM is pretty much consistent with the reading on EPICS. I got 287V on the DVM when the EPICS says 290V.
       Reply  Sat Jul 19 19:39:44 2008, rob, Update, PSL, PMC PZT investigation 
[quote][quote] The 64k is the series resistor after the PA85, not the modeled resistance of the PZT itself.[/quote]
 Yes. What I meant was that because the measured voltage across the PZT was a half of the open voltage of the HV amp, the DC impedance of the PZT is expected
to be similar to the output impedance of the HV amp. Of course, I don't think the DC impedance of a normal PZT should be such low.
Entry  Fri Jul 18 19:43:55 2008, Yoichi, DAQ, Computers, PSL fast channels cannot be read by dataviewer 
At this moment only the PSL fast channels have trouble.
Rob restarted fb40m, c1IOVME, but no effect.
Entry  Fri Jul 18 19:30:20 2008, Masha, Update, Auxiliary locking, moving from 40m 
I will be working in the basement of Bridge probably starting next week; I moved the NPRO laser and some of the optics from my mach zehnder setup on the
SP table to Bridge. Thanks for your help!
Entry  Fri Jul 18 17:12:35 2008, Jenne, Update, IOO, Checking out the MC Servo Board 
[Jenne, Max]

One of the things that Rana thinks that might be causing my MC_F calibration to be off is that the MC Servo Board's filters don't match those on the schematics.
    Reply  Fri Jul 18 19:15:15 2008, Jenne, Update, IOO, Checking out the MC Servo Board 
[quote][Jenne, Max]

I haven't checked to ensure that the MC still locks, because Yoichi is doing stuff on the PSL table, but I didn't change anything on the board, and hooked
Entry  Fri Jul 18 17:06:20 2008, Jenne, Update, Computers, Computers down for most of the day, but back up now 
[Sharon, Alex, Rob, Alberto, Jenne]

Sharon and I have been having trouble with the C1ASS computer the past couple of days.  She has been corresponding with Alex, who has been rebooting the
Entry  Fri Jul 18 16:57:37 2008, Jenne, Update, IOO, Calibrated MC_F MC_Fcalib.png20080717MC_F-MC_I.pdf
I have calibrated MC_F.  The conversion factor is 137.49 MHz/count.

The calibration data taken is attached, along with a calibrated power spectrum.
Entry  Fri Jul 18 12:24:15 2008, josephb, Eric, Configuration, Cameras, Changed Lenses on GC750 at ETMX 
We removed the giant TV zoom lens and replaced it with a much smaller fixed zoom lens.  Currently it views the entire optic.  We have another (also small)
zoom lens which focuses much better on the spot itself.  With how far back the camera is currently placed, neither of these fixed zoom lenses can touch
or hit the view port or the chamber while still attached to camera and mount, even using all of the mount's motion range.  So this should be less of a
Entry  Thu Jul 17 20:13:34 2008, Yoichi, Update, PSL, PMC alignment/mode matching effort 
I'm working to improve the mode matching of PMC.
Because I noticed that the beam was hitting the aperture of the EOM for PMC, I moved the EOM a little bit to maximize the transmission.
This did not change the alignment to the reference cavity but changed the alignment of the PMC a lot.
Entry  Thu Jul 17 16:39:58 2008, Max Jones, Update, DAQ, Magnetometer Installed 
Today I installed the magnetometer near the beam splitter chamber. It is located on the BSC chamber at head height on the inner part of the interferometer
(meaning I had to crawl under the arms to install it). I don't think I disturbed anything during installation but I think that's it's probably prudent
to tell everyone that I was back there just in case. I plan to run 3 BNC cables (one for each axis) from the magnetometer to the DAQ input either tonight
Entry  Thu Jul 17 13:08:37 2008, John, Summary, LSC, HOM resonances in the arms HOMresonances.png
On Tuesday night we attempted to lock the full DRFPMI in the optical spring configuration with the +f2 sideband resonant in the SRC.
Despite having no problems locking on the +f2 in a DRM we couldn't lock the full IFO.
Entry  Thu Jul 17 12:15:21 2008, Eric, Update, PSL, Swept PMC PZT voltage range 
I unlocked the PMC and swept over C1:PSL-PMC_RAMP's full range a couple of times this morning.  The PMC should now be relocked and returned 
to normal.
Entry  Thu Jul 17 08:30:15 2008, steve, Update, PSL, PMC relocked manually pmc4d.jpg
The PMC pzt HV and the servo gain adj. are railing at max this morning

Why is it on the decreasing side of FSS_RTTEMP slope?
Entry  Thu Jul 17 00:59:18 2008, Jenne, Summary, General, Funny signal coming out of VCO VCOout_time.PNGVCOout_freq.PNG
While working on calibrating the MC_F signal, Rana and I noticed a funny signal coming out of the VCO.  We expect the output to be a nice sine wave at about
80MHz.  What we see is the 80MHz signal plus higher harmonics.  The reason behind the craziness is to be determined.  For now, here's what the signal looks
like, in both time and frequency domains.
Entry  Wed Jul 16 17:51:58 2008, Masha, Update, Auxiliary locking, long measurement 
I'm taking a measurement on the SR785 spectrum analyzer at low frequencies, so I'm going to leave it by the symmetric port table for a while. Please don't
move it!
    Reply  Wed Jul 16 22:29:05 2008, Masha, Update, Auxiliary locking, long measurement 
[quote]I'm taking a measurement on the SR785 spectrum analyzer at low frequencies, so I'm going to leave it by the symmetric port table for a while. Please
don't move it![/quote]
Entry  Wed Jul 16 17:36:51 2008, John, DAQ, PSL, FSS input offset 
I changed the nominal FSS input offset to 0 from 0.3. Tolerance remains unchanged at +/-0.05.
Entry  Wed Jul 16 16:59:07 2008, Alberto, Update, General, Aligment 
I think the two beams are aligned again - they both pass the Faraday, they match at the irises and all along the optical path on the AP table. Although
the NPRO beam does not show up at the AS port.
Entry  Wed Jul 16 16:28:14 2008, josephb, Configuration, Computers, Fixed IP address on Switch 
Realized today that the change I made back on June 30th to the switch was to the wrong switch.  I had disabled the DHCP setting and mislabeled the switch
in the control room (which seems to not have affected anything).
ELOG V3.1.3-