  9169   Fri Sep 27 13:55:11 2013 MasayukiUpdateLSCLSC calibration screen  I added the DAQ channel to
all output of calibration servo. The name
of channels are C1CAL_(plant name)_W_OUT_DQ.
  
  9168   Fri Sep 27 00:48:53 2013 MasayukiUpdateLSCFPMI noise caused by ARM locking

    

       
            
 phase_badget.pngFPMI_noises.png 
  9167   Thu Sep 26 23:02:40 2013 ranaUpdateLSCFPMI noise caused by ARM lockingHidden in Nakano-kun's previous entries
was that the phase margin of the X-Arm was
only 9 degrees!! This extremely close to
 Xarm_sweep_130926.pdflsc.pdferr.png 
  9166   Thu Sep 26 21:55:08 2013 ranaUpdateSUSProblems with ETMY Optical LeverNot so fast! We need to plan ahead of time
so that we don't have to repeat this ETMY
layout another dozen times. Please don't
  
  9165   Thu Sep 26 11:00:51 2013 SteveUpdateSUSProblems with ETMY Optical LeverWe are out of JDSU-Uniphase 1103P heads.
I'm ordering some right now. I'm planning
to make some corrections on Rana's list tomorrow
  
  9164   Thu Sep 26 10:55:29 2013 SteveUpdateGeneralY-arm floor space for testLiyuon will set up a  ~5 mW He/Ne
laser for  waist measurement
  
  9163   Thu Sep 26 01:49:28 2013 MasayukiSummaryGreen LockingFPMI noise caused by ARM locking 
 Measurement
 MICH_OLTF.pdfBS-RS55Q.pngETMX-RS55.pngETMY-RS55.pngplot.pdf 
  9162   Wed Sep 25 23:59:29 2013 MasayukiSummaryGreen LockingFPMI noise caused by ARM locking 
Measurement
 XARM_OLTF.pdfYARM_OLTF.pdfXARM_ITMXresponse.pngYARM_ITMYresponse.pngfree_running.pdf 
  9161   Wed Sep 25 23:15:11 2013 MasayukiSummaryGreen LockingFPMI noise caused by ARM lockingI measured some error signal, OLTFs and
responses for FPMI noise estimation. Especially
we are interested in the noise from in-loop
 fpmibd.pdf 
  9160   Wed Sep 25 19:34:51 2013 ranaUpdateSUSProblems with ETMY Optical LeverI went down to investigate the issue with
the extra noise that I found in the ETMY
optical lever yesterday. There were several
 ETMY-BadHeNe.pdf 
  9159   Wed Sep 25 17:07:08 2013 ranaFrogsTreasureFree Green Mango Juice in fridge   aam_pana_recipe.jpg 
  9158   Wed Sep 25 08:11:01 2013 MasayukiSummaryLSCLSC calibration screen 
  
 plot.pdfScreenshot.pngScreenshot-1.pngfringe.pdf 
  9157   Tue Sep 24 22:19:57 2013 ManasaUpdateGeneralFPMI locked [Masayuki, Manasa]
We locked FPMI and measured the FPMI
noise (power spectrum of error signal - MICH_IN1)
  
  9156   Tue Sep 24 20:43:45 2013 masayukiSummarySUSoptical levers centeringI centered optical levers of ITMX,BS,ETMY.
I also change the position of optical levers
of ITMX, ETMY, ITMY, BS on Friday night(9/21),
 Screenshot-Untitled_Window.pngScreenshot-Untitled_Window-1.png 
  9155   Tue Sep 24 10:55:45 2013 ranaUpdatePSLPMC re-alignedAfter relocking the PMC at a good voltage,
Steve and I re-aligned the beam into the
PMC by walking the last two steering mirrors.
 psl-trend.png 
  9154   Sun Sep 22 23:04:52 2013 ranaUpdatePEMGuralp needs recentering After seeing all of these spikes
in the BLRMS at high frequency for awhile,
I power cycled the Guralp interface box (@
 seis.pdf 
  9153   Sun Sep 22 22:54:28 2013 ranaUpdateIOOmode cleaner not lockingHaving trouble again, starting around 1
hour ago. No one in the VEA. Adjusted the
offset -seems to be OK again.
  
  9152   Sun Sep 22 22:05:10 2013 ranaUpdateSUSoplev XY-plots reflect new calibrationThe ETMX oplev signal looks kind of dead
compared to the ETMY. It has no features
in the spectra and the SUM is pretty low.
 noise.png 
  9151   Sun Sep 22 21:28:53 2013 ranaUpdateSUSset OL T RAMP values (they are not visible on the OL screens)controls@rosalba:/opt/rtcds/caltech/c1/scripts/SUS
0$ ./setOLtramps 
Old : C1:SUS-ETMX_OLPIT_TRAMP       
  
  9150   Sun Sep 22 21:03:15 2013 ranaConfigurationSUSTuned bounce and roll mode of ETMY suspension Today I noticed that there was a
lot of noise at the Bounce and Roll eigenfrequencies
for ETMY. I found that the bandstop filter
 etmy-error.pngnotches.pdf 
  9149   Fri Sep 20 22:49:10 2013 MasayukiUpdateLSCLSC calibration screen

    

       
            
 plot.pdf 
  9148   Fri Sep 20 20:27:18 2013 ranaUpdateIOOmode cleaner not locking I used our procedure from this
entry to set the IMC board offset as
well as the FSS board offset.
  
  9147   Fri Sep 20 20:14:52 2013 ranaSummaryGeneral/home/cds nearly full

    

       
            
  
  9146   Fri Sep 20 16:37:30 2013 SteveUpdateVACvertex crane folding arm is back on

    

       
            
 bushingBottom.jpgfoldingI.jpgnoLoadGap.jpgtrollyway.jpgtrollySee.jpg 
  9145   Fri Sep 20 09:49:06 2013 SteveUpdateSUSOptical Lever Trend for 180 days: bad ETMY & PRMI'm working on it.  ETMYoplevPRM.png 
  9144   Fri Sep 20 08:15:30 2013 SteveUpdateComputer Scripts / ProgramsOttavia, Rossa and PianosaOttavia, Rossa  and Pianosa are running
out of storage  space.
 Ottavia.pngRossa.pngPianosa.png 
  9143   Thu Sep 19 21:42:18 2013 ranaUpdateSUSOptical Lever Trend for 90 days: ETMX and PRM are the bad ones   OLtrend_2013.png 
  9142   Thu Sep 19 21:15:44 2013 ranaUpdateComputer Scripts / ProgramsPMC lockerI used a script (~PSL/PMC/testAutoLocker.sh)
to unlock the PMC and run autlocker ~100
times to see how robust the new autlocker
 Untitled.pdf 
  9141   Thu Sep 19 18:48:24 2013 ranaUpdateComputer Scripts / ProgramsPMC locker In May of 2013 Den wrote a PMC Autolocker
because he ignored / didn't want to read
anyone else's code. Later that year Yuta
 pmc.png 
  9140   Thu Sep 19 10:24:58 2013 SteveUpdatePEMPRM damping restored after earth quakeLocal m3.8
eq shakes PRM lose.
 eq3.8mLaVerne.png 
  9139   Wed Sep 18 14:57:12 2013 SteveUpdateVACvertex crane folding arm removed The folding beam removed as shown.
Two man supporting it while I hammering it
out. Pin was dry and it gulled into supporting
 manPower.jpgrotatingHinge.jpgsupportingHinge.jpggullingPin.jpg 
  9138   Wed Sep 18 11:52:53 2013 JamieUpdateCDSDataviewer cannot connect to fb

    

       
            
  
  9137   Wed Sep 18 11:29:43 2013 manasaUpdateCDSDataviewer cannot connect to fbMasayuki pointed out that dataviewer wasn't
connecting to the fb this morning.
When I started dataviewer from the
 CDS_FE.png 
  9136   Tue Sep 17 18:44:29 2013 MasayukiUpdateLSCLSC calibration screenI update the LSC calibration screen. This
screen is for real time calibration of each
DOF with using error signal and control signal.
 calibration_screen.png 
  9135   Tue Sep 17 17:55:42 2013 Jamie.ConfigurationComputer Scripts / Programspyepics configured

    

       
            
  
  9134   Tue Sep 17 00:50:42 2013 MasayukiUpdateLSCMICH calbrationI found the bug in my calibration
code, and I fixed it.
 noise.PNG 
  9133   Mon Sep 16 19:41:01 2013 ranaConfigurationComputer Scripts / Programscdsutils checked out into /opt/rtcds controls@rosalba:~
0$ cdsutils
  
  9132   Mon Sep 16 15:29:50 2013 JamieConfigurationComputer Scripts / Programscdsutils checked out into /opt/rtcdsWe now have a proper install of cdsutils:

 controls@rossa:~ 0$ cdsutils
 usage:
cdsutils <cmd> <args>

 Advanced
  
  9131   Mon Sep 16 14:11:47 2013 ranaUpdateLSCMICH calbration  There doesn't seem to be any
coherence among the different directions
of ground motion (as expected from seismic
 Screen_Shot_2013-09-16_at_2.10.31_PM.pngScreen_Shot_2013-09-16_at_2.18.47_PM.png 
  9130   Mon Sep 16 13:11:15 2013 EvanUpdateComputer Scripts / ProgramsComsol 4.3b upgradeComsol 4.3b is now installed under /cvs/cds/caltech/apps/linux64/COMSOL43b.
I've left the existing Comsol 4.2 installation
  
  9129   Mon Sep 16 10:57:11 2013 SteveUpdateVACRGA scan at day 41

    

       
            
 pd76m41dRGA.pngpd76m41d.png 
  9128   Fri Sep 13 19:22:01 2013 MasayukiUpdateLSCMICH calbration 
 I made sure the yesterday's
result was collect. I measured not only the
 noise.PNG 
  9127   Thu Sep 12 23:36:25 2013 MasayukiUpdateLSCMICH calbrationFor Modelling of the OLTF, I measured the
response of the BS suspension. I used the
OSEM sensor for measurement. The attatchment1
 BSsus.PNGITMXsus.PNGITMY.PNGfree_running.PNG 
  9126   Thu Sep 12 01:06:09 2013 JenneUpdateASCSRCL ASS implementedI have modified the ASS model to also have
an ASS for SRCL.  The input options
are POPDC, POP110, AS110.  I suppose
  
  9125   Thu Sep 12 00:07:26 2013 MasayukiSummaryGreen LockingALS locking in both arms

    

       
            
  
  9124   Wed Sep 11 23:43:10 2013 KojiSummaryGreen LockingALS locking in both armsWhat was the beat freq for each arm?
The HF noise level depends on the
frequency of the beat note.
  
  9123   Wed Sep 11 23:34:37 2013 MasayukiSummaryGreen LockingALS locking in both arms[manasa, masayuki]
We locked the XARM and YARM with
using ALS control loop and
 noise.pdf 
  9122   Wed Sep 11 17:35:38 2013 JenneUpdateLSCALS requirementI have done a quickie look at Optickle
to see how the linewidth of an arm cavity
changes versus the configuration. 
 ArmLinewidthComparison.pngLinewidthComparison.png 
  9121   Tue Sep 10 17:35:50 2013 Masayuki, ManasaUpdateLSCMICH calbration

    

       
            
 MICH_calib_loops.pngOLTF_MICHDC.pngMICH_DC_resp.pngMICH_RF_resp.pngMICH_free_noise.png 
  9120   Tue Sep 10 15:43:01 2013 SteveUpdateVACTP3' dry pump is replaced

    

       
            
  