  9334   Mon Nov 4 11:37:12 2013 SteveUpdateIOOPSL output shutter installed 
 The PSL shutter is reinstalled.The
base plate is delrin for isolation and the
 Shutterisback.jpg 
  9333   Mon Nov 4 09:03:21 2013 SteveUpdatePSLPMC auto locker

    

       
            
 3dTREND.png 
  9332   Sun Nov 3 00:05:52 2013 CharlesSummaryISSISS Update - Bout' timeRight near the end of summer, I had an
ISS board that was nominally working, but
had a few problems I couldn't really sort
 full-op-loop.pngfull-cl-loop.pngreq-vs-meas.png 
  9331   Sat Nov 2 22:49:44 2013 CharlesUpdateISSCTN ISS Noise Suppression Requirement - Updated 10/27 Previously in elog
8959, I gave a very simple method for
determining the noise suppression behavior
 7x 
  9330   Sat Nov 2 19:36:15 2013 CharlesUpdateGeneralPossible misalignment? I was working on the electronics
bench and what sounded like a huge truck
rolled by outside. I didn't notice anything
  
  9329   Fri Nov 1 19:09:01 2013 rana, evanConfigurationPSLPMC reflected beam nonsense While looking at the PMC REFL beam
for the AOM diffracted beam, we noticed that
although only one beam exists between the
  
  9328   Fri Nov 1 18:59:41 2013 EvanConfigurationISSAOM cabling[Rana, Nic, Evan]
We did some work today on getting
the AOM back up and running so that we can
 aom.jpgaom_driver.jpgaom_driver_power.jpg20131101_170120.jpg 
  9327   Fri Nov 1 17:44:06 2013 KojiSummaryLSCSimulation of REFL_3f signal when the arms come inYes, the resonance of the 2nd-order sidebands
to the IFO screws up the 3f scheme.
2f (~22MHz) and 10f (~110MHz) are
  
  9326   Fri Nov 1 17:01:46 2013 GabrieleSummaryLSCSimulation of REFL_3f signal when the arms come in I simulated how the 3f signal is
affected by the resonance condition of the
arms.
 refl_3f_I_vs_cavity_tuning_noresf2.pngrefl_3f_I_vs_cavity_tuning.png 
  9325   Fri Nov 1 09:45:32 2013 SteveUpdateIOObeam dumps to be find

    

       
            
 razor_beam_dumps.jpg 
  9324   Thu Oct 31 21:22:00 2013 rana, kojiSummaryIOOmodulation beat note in MC servoI hooked up the 4395 to the MC servo board
test out (TP2A) and looked at the spectrum
using our new SPAG4395.py script. We noticed
 13031.png13031_200.png13031_200b.png 
  9323   Thu Oct 31 20:05:48 2013 RANAUpdateIOOMode Cleaner Tune-UP

    

       
            
 drifty.png 
  9322   Thu Oct 31 15:34:28 2013 manasaUpdateIOOMC not happy since yesterday

    

       
            
 MC_drift.png 
  9321   Thu Oct 31 00:06:45 2013 masayukiUpdateComputer Scripts / Programscds fft,tf,offsetsI
wrote the scripts for cdsutils.
1.
  
  9320   Wed Oct 30 16:46:17 2013 manasaUpdateIOOMC alignedMC has not been very happy since last night. 
What I did to fix this:
1. Disabled autolocker and WFS and
  
  9319   Wed Oct 30 14:58:44 2013 SteveHowToGeneralshutting down a computer 
 We have tried to ssh into c1iscey
yesterday morning. It just did not work.
  
  9318   Wed Oct 30 08:32:55 2013 EvanHowToComputer Scripts / ProgramsmatplotlibrcFYI, you can trick out matplotlib by creating
a matplotlibrc config
  
  9317   Wed Oct 30 03:36:51 2013 JenneUpdateLSCMICH and PRCL UGFs change with ALS enabledMasayuki was able to hold both arms off-resonance
with ALS long enough for me to lock the PRMI
(arms still held off resonance), and take
  
  9316   Wed Oct 30 03:33:17 2013 RanaUpdateLSCLSC demod boards need some thought 
 
 0309.png 
  9315   Wed Oct 30 01:53:52 2013 JenneUpdateIOOMode Cleaner relockedThe MC (mostly MC2) decided a few minutes
ago to move, so I put the SUSPIT and SUSYAW
numbers back where they were, and the tweaked
  
  9314   Wed Oct 30 01:44:13 2013 JenneUpdateLSCMICH and PRCL gains adjusted (Config file saved)

    

       
            
  
  9313   Wed Oct 30 01:22:56 2013 JenneUpdateLSCREFL 165 demod phase adjusted

    

       
            
  
  9312   Wed Oct 30 00:02:25 2013 JenneUpdateLSCLSC demod boards need some thoughtAs we are meditating on things to look
at for PRMI + 2 arms, Rana brought up the
question of the demod board situation. 
  
  9311   Tue Oct 29 22:33:57 2013 ranaUpdateSUSETMY sensors compared to ETMX

    

       
            
 Scratch-n-SniffStinkyDooBabyShowerGame1.jpg 
  9310   Tue Oct 29 18:54:36 2013 JamieConfigurationComputer Scripts / Programsfixing python-matplotlib from LSCSOFT

    

       
            
  
  9309   Tue Oct 29 18:14:52 2013 JamieConfigurationComputer Scripts / Programsfixing python-matplotlib from LSCSOFTJenne just discovered an issue with the
python-matplotlib package that I knew was
coming but forgot about.
  
  9308   Tue Oct 29 16:51:31 2013 JenneUpdateCDSLSC test points were used upMasayuki was concerned that some LSC channels
were giving him all zeros.  After seeing
the error in the terminal window running
  
  9307   Tue Oct 29 10:51:16 2013 MasayukiUpdateSUSETMY sensors compared to ETMX[Steve, Masayuki]
We lowered the
  
  9306   Mon Oct 28 21:33:55 2013 RANAUpdateIOOMode Cleaner Tune-UP 
8 day minute trend of some of the
IMC alignment signals.
 Untitled.png 
  9305   Mon Oct 28 18:57:27 2013 MasayukiHowToLSCread 'scope and spectrum analyser datas 
The
command to get the data from spectrum analyzer
  
  9304   Mon Oct 28 14:24:01 2013 MasayukiUpdateLSC'scope and spectrum analyser for REFL165 
 I connected the 'scope between
REFL165 output and demod board input. I split
  
  9303   Mon Oct 28 14:12:48 2013 manasaUpdateIOOMode Cleaner relocked

    

       
            
 Screenshot-Untitled_Window-3.png 
  9302   Mon Oct 28 12:53:23 2013 JenneUpdateCDSFarfalla and Asia added to Host Table in Wiki

    

       
            
  
  9301   Sun Oct 27 23:26:44 2013 ranaUpdatePEMSeismometer status It would be nice if we could use
the existing seismometer cable and place
a 2-terminal temperature sensor within the
  
  9300   Sun Oct 27 19:19:42 2013 DenUpdatePEMSeismometer status

    

       
            
 TrilliumPlate.PDFGuralpPlate-1_final.pdf 
  9299   Sun Oct 27 03:41:06 2013 ranaUpdateSUSETMX violin mode  I thought it would be enough
to notch the fundamental and the first harmonic,
but sometime tonight the 2nd harmonic at
 ETMX-Vio3-Ring.png 
  9298   Sun Oct 27 00:15:35 2013 RANAUpdateSUSc1auxex At some point tonight we lost our
CA connection to c1auxex (which is actually
the computer at the X End and controls the
 arms.pdfarm-mc2-dewhite.pdf 
  9297   Sat Oct 26 22:48:55 2013 ranaUpdateCDSNew/old CDS laptop for X-End    
  9296   Sat Oct 26 21:46:33 2013 RANAUpdateIOOMode Cleaner Tune-UP The
MC had been unlocked for the last 4 hours
and was crying out to me so I gave it some
 MCtrend.pdfMC40days.png 
  9295   Fri Oct 25 21:36:51 2013 MasayukiUpdateLSC'scope and spectrum analyser for REFL165

    

       
            
  
  9294   Fri Oct 25 21:28:49 2013 MasayukiUpdateLSCREFL PDs spectrum I measured the spectrum of the REFL165
output using AG4395A. As this entry
we put the directional coupler between REFL165
 REFL.pngREFLspe.zip 
  9293   Fri Oct 25 20:11:08 2013 JenneUpdateLSCMICH gain in PRMI lowered by factor of 2We were locking the PRMI, but it is very
rumbly today.  I reduced the MICH servo
gain from -0.8 to -0.4 , and things seem
  
  9292   Fri Oct 25 19:56:58 2013 ranaUpdatePSLlaser drift monitor set up 
 I went to re-align the beam
into the PMC just now. I also tapped all
 PMC-IRSISSS.pngPA250052.JPGPA280044.JPG 
  9291   Fri Oct 25 10:45:16 2013 SteveUpdatePSLlaser drift monitor set up


   
        
            
 laserDriftMon.jpgPMCT_120d.pngPMCT_1000d.png 
  9290   Fri Oct 25 04:54:21 2013 MasayukiUpdateSUSETM violin modeSummary
When PRMI + 2arms are locked yesterday,
we heard the noise from suspension violin
 violin1.pdfviolin2.pdf 
  9289   Fri Oct 25 04:03:40 2013 MasayukiUpdateLSC'scope and spectrum analyser for REFL165As Jenne's Elog we want to see Spectrum
and time series of REFL 165 (our PRMI LSC
locking PD) to see if the signal is saturated
  
  9288   Fri Oct 25 01:46:33 2013 ranaUpdateCDSfb acquisition of slow channels Rather than limp along with a broken
SLOW channel system, I fixed it so that the
EDCU files made during the RCG build actually
  
  9287   Thu Oct 24 23:30:57 2013 jamieUpdateCDSnew dataviewer installed; no longer works on Ubuntu 10 workstations

    

       
            
  
  9286   Thu Oct 24 23:25:37 2013 JenneUpdateLSCEnd transmission triggering

    

       
            
  
  9285   Thu Oct 24 23:12:21 2013 jamieUpdateCDSnew dataviewer installed; no longer works on Ubuntu 10 workstations

    

       
            
  