ID |
Date |
Author |
Type |
Category |
Subject |
9423
|
Fri Nov 22 14:21:43 2013 |
Jamie | Update | Computer Scripts / Programs | DAQ? |
Quote: |
Jamie, I think the computers know that you are away. c1lsc keeps going down.
The short time plots are correct.
|
Is there some indication from the attached image that there is a problem with c1lsc? I see some drop outs in the channels you're plotting, but those are not c1lsc channels.
The channels with the drop outs are I think derived channels, as opposed to ones that are generated on the front end. Therefore they could have been affected by the c1auxey outages from earlier in the week. |
9422
|
Fri Nov 22 09:54:22 2013 |
Steve | Update | CDS | DAQ? | Jamie, I think the computers know that you are away. c1lsc keeps going down.
The short time plots are correct. |
Attachment 1: comp8d.png
|
|
9421
|
Thu Nov 21 16:32:20 2013 |
Steve | Update | IOO | PMC needs a touch of love |
The PMC power degrading on this 3 days plot. MC2 -T = 14,200 counts. C1:IOO-MC_TRANS_SUM can not be ploted in dataviewer. The MEDM screen has a valid number.
Initial pointing is not so bad (what does "not so bad" mean ???)
C1iscey comes and goes again.
|
Attachment 1: PMCplus.png
|
|
9420
|
Thu Nov 21 10:24:50 2013 |
Koji | Update | SUS | beam dumps | You don't need the fourth glass piece on the diamond beam dump. |
9419
|
Thu Nov 21 09:56:15 2013 |
Steve | Update | SUS | green glass beam dumps | Green welding glass is used in these Koji designed dumps (D1102375)
We have 10 pieces of hexagonal dumps for 5.5" high beam They require 1 5/8" space. Atm1
Atm2, Large V traps are 3" tall only, 5 pieces
Atm3, Diamond shapes come with 2" and 1" square green glass ( after Koji's correction I removed the not needed glass ) D1102445 and D1102442

Baked green glass pieces in stock: 30 pieces of 2" x 2" ,--- 30 pieces of 1" x 1",David 4-17-2014
Baked diamond holders in stock: 10 pieces of 2" and 10 pieces of 1"David 4-17-2014
PEEK shims 2" and 1"
Baked green glass pieces blank: 4 pieces of 7" x 9"
Baked green glass pieces with 40 mm hole on 7" x 9" for SUS tower: 7 pieces.
NOTE: in December 2012 we talked about 50 mm aperture need. What diameter is the right one today? 51 mm aperture plates are cut 4-10-2014
|
Attachment 1: HEXdump.jpg
|
|
Attachment 2: Vdump.jpg
|
|
Attachment 3: Diamond1_2inchTraps.jpg
|
|
9418
|
Wed Nov 20 17:05:15 2013 |
Jenne | Update | LSC | Xend QPD and Whitening board replaced | [EricQ, Jenne]
We have put the Xend QPD back in place, and centered it. The whitening board was replaced by me a few days ago.
We also went down to the Yend and centered the Yend QPD.
I used the offset.py script that Masayuki wrote to zero the offsets of the individual quadrants when the PSL shutter was closed, and then I averaged the output of the SUM filter banks, and made the gains 1/AvgSum, so that both the Thorlabs PD and the QPD are normalized to 1 at single-arm resonance, for each arm.
I don't know what the gain is of the QPD head off the top of my head, relative to the Thorlabs PD, but eventually we want them to be the same, so that 1=1 and 700=700 on each PD. |
9417
|
Wed Nov 20 16:05:52 2013 |
Jenne | Update | LSC | PRMI carrier locking, OpLev Check | [Jenne, EricQ]
We locked the PRMI on carrier again today, after lunch. Following a suggestion from the 40m meeting, we wanted to compare the PRMI carrier fluctuations with the new vs. old OpLev servo for the PRM.
To do change between the servo shapes, I put in an elliptic lowpass at 35Hz, since I overwrote that with the 55Hz lowpass the other day. The only other change between shapes is turning on and off my boost / emphasis filter.
So, the scenarios were:
(1) New OpLev servo
(2) Old OpLev servo (no boost, but 3.2Hz res gain and bounce roll notches on), with 55Hz lowpass
(3) Old OpLev servo with 35Hz lowpass
For scenario (1), like last night, there were small power fluctuations. For scenario (2), most of the time there were small power fluctuations, but occasionally there would be a kick somewhere, and the power would dip down by ~50%, and the fluctuations would continue like a ringdown for a few seconds, and then we'd be back to small fluctuations until the next kick. For scenario (3), even with trying different LSC servo gains, we could not get the PRMI to lock on carrier for more than a few tenths of a second. During that time, the power fluctuations were very large.
So, the old oplev servo was kind of okay, but the lowpass at 35 Hz was bad, bad, bad. It seems that the new OpLev servo is doing good things for us. |
9416
|
Wed Nov 20 01:10:38 2013 |
Jenne | Update | LSC | PRMI carrier locking | I have increased the gain of the MICH loop to -100, and set FMs 2,3,7 to be triggered. I have also increased the PRCL gain to 2. The PRCL ASC pitch and yaw gains used to be -0.004, but I have increased them both to -0.01.
Now, I'm seeing power fluctuations in POPDC of ~200 pk-pk, at an average value of 2650. That's a RIN of 7.5% . If I turn off all OSEM damping for the PRM (after the cavities are already locked), I get POP DC fluctuations of 100 pk-pk at the same average value, so a RIN of 4%.
Back on October 30th (elog 9338), we had an average POPDC of 400, with fluctuations of 200 pk-pk, so a RIN of 50%.
So, I am pleased that, with the carrier locking, I have lower power fluctuations. And, since there is more overall power in the PRC right now than we had 3 weeks ago, I'm hopeful that a PRMI+arms test will have lower power fluctuation.
Also, a note, when my MICH gain was still low, I had lots of power fluctuation at the AS port, which was coherent with my POPDC power fluctuations (which makes sense). At that time, my overall RIN was higher than it is now (although I neglected to write down the numbers), but more significantly, I saw occasional 'kicks', where the ASDC and POPDC powers would ring for 1 or 2 seconds, with power fluctuations of order 40%. I have not seen any of those kicks since increasing the MICH gain. |
9415
|
Tue Nov 19 21:59:35 2013 |
manasa | Update | LSC | PRMI carrier locking |
Quote: |
Since we have never tried to lock PRMI on carrier after the folding mirrors were flipped, I tried to lock PRCL on carrier.
I thought this might give us some idea about the PRC stability for resonance or some clue as to what happens to the PRM suspensions and PRMI stability when we have carrier resonating in the cavity.
I changed the sign of the PRCL gain and also tried increasing the gain. But this did not work and I was not able to carrier lock PRMI. May be I am missing to change some parameter that is very trivial?
|
PRMI could not be locked on carrier using 3f. The configuration from the last time when PRMI was carrier locked (elog) were used and PRMI locked on carrier with these settings.
== PRMI carrier ==
MICH: AS55_Q_ERR, AS55_PHASE_R = -12 deg, MICH_GAIN = -0.2, feedback to ITMX(-1),ITMY(+1)
PRCL: REFL55_I_ERR, REFL55_PHASE_R = 70 deg, PRCL_GAIN = 1.0, feedback to PRM
Below is the video capture showing the PRM front and back face when carrier flashes with few second locks.
EDIT by JCD:
The demod phase numbers that Manasa is quoting above were correct back in March, when the elog she's quoting from was written. They are not true now, since we've adjusted things in the last 8 months. Also, I'm using a gain of -1.5 for MICH, and +1.5 for PRCL. MICH has no FMs triggered, PRCL has FM 2,3,6 triggered. Since we won't be using this configuration for full locking, but just for some tests, I'm currently using AS55 Q for MICH, and REFL 55I for PRCL, and using the ITMs to actuate on MICH for today. |
9414
|
Tue Nov 19 21:28:05 2013 |
manasa | Update | LSC | PRMI carrier locking | Since we have never tried to lock PRMI on carrier after the folding mirrors were flipped, I tried to lock PRCL on carrier.
I thought this might give us some idea about the PRC stability for resonance or some clue as to what happens to the PRM suspensions and PRMI stability when we have carrier resonating in the cavity.
I changed the sign of the PRCL gain and also tried increasing the gain. But this did not work and I was not able to carrier lock PRMI. May be I am missing to change some parameter that is very trivial? |
9413
|
Tue Nov 19 17:47:17 2013 |
Jenne | Update | LSC | PRMI+2arms attempt | So far this afternoon, I have redone the IFO alignment, locked both arms with ALS, moved both arms off resonance, locked PRMI, and started bringing one arm back to resonance.
The alignment was really not good, which I knew yesterday, but the ASS wasn't working yesterday. I hand-did the alignment, and tried locking, which was easier with the slightly better alignment.
I locked both arms with ALS, found the resonances, and then moved them off resonance using Masayuki's scripts.
I then restored the PRM alignment, and locked the PRMI.
I started bringing the Yarm back, but I kept losing lock when I got to about 0.1 transmission.
After losing lock several times, I switched over to looking at the ASS. I have figured out the problem, and fixed it. The ASS for the arms now works again.
Looking at the StripTool plots of the lockin outputs for each arm, it was clear that the "L" traces were their usual size, but the "T" traces, which are demodulated versions of the transmission DC PDs, were tiny. I investigated in the model, and the answer is obvious: both the LSC and the ASS get the transmission information directly from the end sus computers. Since we recently moved the normalization gain for the transmission diodes into the SUS models from the LSC model, this means that the ASS was seeing a differently sized signal than it had in the past.
To fix this, I put a gain into the T_DEMOD_SIG filter banks for all 8 lockins that use info from the transmission DC PDs. I used 1/g , where g is the gain that is in the C1:SUS-ETM#_TR#_GAIN channels. For TRX, that number is -0.003, and for TRY that number is 0.002 . So, in the .snap file that is used when turning on the ASS, I have given the Xarm lockins a gain of -333, and the Yarm lockins a gain of 500. I chose this place, because the only thing that has happened to the signal until this point is a bandpass, so the rest of the servo gains can remain the same.
I tested the ASS, and it works just like it used to. I let it run, and align all of the optics, then I misaligned by a small amount each of the ETMs, saw that the lockin output values changed, and then were servoed back to zero. So, it seems all good. |
9412
|
Tue Nov 19 15:04:14 2013 |
Jenne | Update | CDS | Can talk to AUXEY again | The ETMY sliders on IFO_ALIGN were white again this morning, so I went down to the Yend and pushed the RESET button on auxey. I then did a burt restore to 00:07am this morning for both auxey and auxex (since the stickers on the machines are still the old naming convention, I wonder if the autoburt is also backwards, so I did both). Now the 'save' and 'restore' scripts for ETMY are working again.
Hopefully it's all better now, but I'll keep an eye on it. |
9411
|
Tue Nov 19 14:47:59 2013 |
manasa | Update | LSC | Green status |
Quote: |
After I aligned the IR interferometer (no ASS - we still need to figure out what's going on with that), I am trying to find the green beatnotes for each arm.
First, I locked the green lasers to each arm.
I then went out to the PSL table and aligned the Green Yarm path by overlapping the near-field and far-field of the yarm transmission and the PSL green pickoff. I then turned on the power for the Beat PDs, since it was off (I confirmed that the outputs were plugged into the beatbox, so they are seeing 50 ohms). I assume that the beat PDs were off since Manasa pulled the Beatbox last week, but there is no elog reference!! Anyhow, after seeing a real signal, I maximized the DC power on the beat PD for the Yarm. I then maximized the light on the DC transmission PD for the Yarm.
I looked at the Xarm, and the near-field alignment looks okay, but I haven't checked the far-field.
I started looking for the beatnotes from the control room:
I am changing the SLOW_SERVO2_OFFSETs by 30 counts, and then unlocking and relocking the arms, and checking to see if I see a peak on the RF spectrum analyser.
The Y offset started at -10320, and I found a beatnote at -11230 (beatnote is about 26MHz). The X offset started at 4500. Going larger seemed to get me to a less bright TEM00 mode, so I switched and have been searching by going down in offset, but haven't yet found the beatnote. I suspect that I actually need to align the X path on the PSL table. The Y beatnote is very small, about -30dBm, so I also need to tweak the alignment by maximizing the peak value.
|
I found the beatnotes for both the X and Y arm ALS this morning. The beat amplitudes measured -5dBm and -18dBm respectively and occurred at SLOW SERVO2 OFFSET 4550 and -10340. I had to only tweak the Y green PSL alignment to increase the beat amplitude.
I locked both the arms using ALS and they were stably locked until MC unlocked for a moment (nearly 16 minutes).
The only thing missing in the list of things you looked into is the status of the PSL slow actuator adjust. Check if this is near zero. |
9410
|
Tue Nov 19 14:47:44 2013 |
Jenne | Update | LSC | PRM oplev measured and modeled TF |
Quote: |
I forgot how we could turn on the PRM oplev servo and the PRM ASC servo at the same time without conflict.
It seems that this new oplev servo covers 0.04 to 8Hz. It's pretty broadband. Do we inject the ASC signal to the oplev error?
|
Right now all 3 servos that control PRM angle (OSEM damping, Oplev, and ASC) run in parallel, and they're all AC coupled. |
9409
|
Tue Nov 19 11:56:10 2013 |
manasa, jenne, ericQ | Update | LSC | PRM- OSEM side ccd camera is in place |
Quote: |
Quote: |
Can't we somehow hook up this camera to the MUX with the movie mode?
I think both the MUX and the sensoray are compatible with the color video signal.
Only the old CRT is B/W.
|
Watek ccd with Tamron lens is hooked up to MUX
This set up close to the viewport glass! Please be careful!
|
Video captures when power recycling cavity is locked (videos 1 & 2) and flashing (video 3). Arms stayed misaligned.
1. CH1 and CH2 are loooking at PRM front and back faces. CH3 and CH4 are looking at POP and REFL
2. CH1 and CH2 are loooking at PRM front and back faces. CH3 and CH4 are looking at the ITMs
3. CH1 and CH2 are loooking at PRM front and back faces. CH3 and CH4 are looking at POP and REFL
|
9408
|
Tue Nov 19 11:33:39 2013 |
Steve | Update | SUS | PRM- OSEM side ccd camera is in place |
Quote: |
Can't we somehow hook up this camera to the MUX with the movie mode?
I think both the MUX and the sensoray are compatible with the color video signal.
Only the old CRT is B/W.
|
Watek 902H ccd with Tamron M118FM50 lens is hooked up to MUX Please be careful! In this set up the lens is close to the view port glass window! |
Attachment 1: closetoWindowGlass.jpg
|
|
Attachment 2: DangerUnprotectedViewport.jpg
|
|
9407
|
Tue Nov 19 01:11:19 2013 |
Jenne | Update | LSC | Green status | I am able to lock the Yarm ALS, but not at the full gain that I should be. I attribute this to my mediocre alignment of the path on the PSL table. EDIT: Manasa pointed out that I forgot to set the PSL FSS slow adjust to ~zero, so the PSL temperature was off, so there wasn't really any hope for me last night.
However, I decided that I should write down the ALS locking procedure, as shown to me by Masayuki on 29Oct2013, that is written in one of the Control Room notebooks. So, here it is. I will write channel names and DTT template names for the Y arm, but the procedure is the same for both arms.
- Lock and align arms using IR.
- Lock green beams to arms.
- Align green beams to arms.
- Check beatnote alignment on PSL table.
- Find beatnote by changing end laser temperature (C1:ALS-Y_SLOW_SERVO2_OFFSET) in steps of ~30, watch spectrum analyser for peak. Easier if arms are locked in IR, but disable LSC system before moving to step 6. Beatnote should be less than ~50 MHz, and should have a peak height of about -20dBm or more. When doing 2 arms, be careful that beatnotes of the different arms do not overlap in frequency. Manasa reminds me that you must also remember to set the PSL FSS SLOW actuator adjust to near zero, to get the PSL back near its nominal temperature.
- Check UGF of phase tracker loop. (DTT template in /users/Templates/ALS/YALS_PT_OLTF.xml) Want UGF to be ~2kHz. Change C1:ALS0BEATY_FINE_PHASE_GAIN as necessary.
- Start the watch script from the ALS screen to watch for lockloss.
- Look at the PHASE_OUT spectrum (DTT template in /users/Templates/ALS/ALS.xml).
- Clear history of Phase Tracker Loop (clear hist button on C1:ALS-BEATY-FINE_PHASE screen). Very important to do this before step 10, every time you get to step 10 (i.e. if you lose lock and are starting over)!
- Check sign of loop gain by using + or - 0.1 for the gain (C1:ALS-YARM_GAIN). Beatnote should immediately stop moving if you have the sign right. Otherwise, it'll zip around (if it does, repeat step 9, step 10).
- Turn gain of ALS up to ~15. Watch the PHASE_OUT spectrum, look for the servo bump. When you see it, back off the gain a little. Gain of ~15 is usually about the right ballpark.
- Turn on FM 2, 3, 6, 7, 8 of C1:ALS-YARM. (FM5 should already have been on).
- Wait for PHASE_OUT spectrum to come down. Turn on FM10 of C1:ALS-YARM.
- Check UGF of ALS loop (DTT template in /users/Templates/ALS/YALS_OLTF.xml). Want UGF to be about 150 or 170 Hz (at the peak of the phase bubble). Adjust C1:ALS-YARM_GAIN as necessary.
- ALS is locked! Use something like the "Scan Arm" script from the ALS screen to find IR resonance, or do whatever measurement you want. Dataviewer template /users/Templates/Dataviewer_Templates/ALSdtv.xml may be useful.
|
9406
|
Tue Nov 19 00:18:30 2013 |
Jenne | Update | LSC | Green ALS wishlist | EricQ said that he's going to start hanging out at the 40m a bit, and I was thinking about what I can have him help me with. This lead to me writing up a wishlist for things that have to do with the ALS system and green lasers. Some of these are very small tasks, while others are pretty big. They are certainly not all high priority. But, they're on my wishlist.
Calibrations
- How many counts of SLOW_SERVO2_OFFSET is one green FSR (for each arm)?
- Calibrate ALS OFFSETTER#_OFFSET counts to nm or Hz offset between the end lasers and the PSL.
Automation / script writing
- Automate finding the beatnotes (requires freq counters)
- Automate locking the ALS
Digital Acquisition
- All 3 laser temperatures
- Frequency counting of beatnotes
Hardware
- Install flipper mirrors on the PSL table to switch between trans DCPDs and far-field views of beam overlap for each arm.
- IR beatnote project - send pickoff of end lasers to PSL via fiber, set up beat detection for each arm, create PLLs.
- Yarm PZT installation and autoalignment.
|
9405
|
Tue Nov 19 00:07:16 2013 |
Jenne | Update | LSC | Green status | After I aligned the IR interferometer (no ASS - we still need to figure out what's going on with that), I am trying to find the green beatnotes for each arm.
First, I locked the green lasers to each arm.
I then went out to the PSL table and aligned the Green Yarm path by overlapping the near-field and far-field of the yarm transmission and the PSL green pickoff. I then turned on the power for the Beat PDs, since it was off (I confirmed that the outputs were plugged into the beatbox, so they are seeing 50 ohms). I assume that the beat PDs were off since Manasa pulled the Beatbox last week, but there is no elog reference!! Anyhow, after seeing a real signal, I maximized the DC power on the beat PD for the Yarm. I then maximized the light on the DC transmission PD for the Yarm.
I looked at the Xarm, and the near-field alignment looks okay, but I haven't checked the far-field.
I started looking for the beatnotes from the control room:
I am changing the SLOW_SERVO2_OFFSETs by 30 counts, and then unlocking and relocking the arms, and checking to see if I see a peak on the RF spectrum analyser.
The Y offset started at -10320, and I found a beatnote at -11230 (beatnote is about 26MHz). The X offset started at 4500. Going larger seemed to get me to a less bright TEM00 mode, so I switched and have been searching by going down in offset, but haven't yet found the beatnote. I suspect that I actually need to align the X path on the PSL table. The Y beatnote is very small, about -30dBm, so I also need to tweak the alignment by maximizing the peak value. |
9404
|
Mon Nov 18 21:40:24 2013 |
Koji | Update | LSC | PRM oplev measured and modeled TF | I forgot how we could turn on the PRM oplev servo and the PRM ASC servo at the same time without conflict.
It seems that this new oplev servo covers 0.04 to 8Hz. It's pretty broadband. Do we inject the ASC signal to the oplev error? |
9403
|
Mon Nov 18 21:26:13 2013 |
Koji | Update | SUS | PRM pictures | Can't we somehow hook up this camera to the MUX with the movie mode?
I think both the MUX and the sensoray are compatible with the color video signal.
Only the old CRT is B/W. |
9402
|
Mon Nov 18 21:20:54 2013 |
Jenne | Update | CDS | Can't talk to AUXEY? |
Quote: |
The restore scripts from the IFO config screen half-failed, with this error:
retrying (1/5)...
retrying (2/5)...
CA.Client.Exception...............................................
Warning: "Virtual circuit disconnect"
Context: "c1auxey.martian:5064"
Source File: ../cac.cpp line 1214
Current Time: Wed Nov 13 2013 17:24:00.389261330
..................................................................
Jamie, do you know what this might be? When requested, ETMY was not misaligned or restored, but we got these errors. So, somehow we're not talking properly to EY, but other things seem fine (the models are running okay, the suspension is damped, etc, etc.)
|
The auxey machine is back, in that I can interact with the IFO_ALIGN sliders, and they actually make the optic move, but I still can't read and write to and from the EPICs channels:
controls@rossa:/opt/rtcds/caltech/c1/medm/MISC/ifoalign/burt 0$ cdsutils read C1:SUS-ETMY_PIT_COMM
CA.Client.Exception...............................................
Warning: "Virtual circuit disconnect"
Context: "c1auxey.martian:5064"
Source File: ../cac.cpp line 1214
Current Time: Mon Nov 18 2013 21:13:52.044973819
..................................................................
Could not connect to channel (timeout=2s): C1:SUS-ETMY_PIT_COMM
controls@rossa:/opt/rtcds/caltech/c1/medm/MISC/ifoalign/burt 1$ cdsutils read C1:SUS-ETMY_YAW_COMM
CA.Client.Exception...............................................
Warning: "Virtual circuit disconnect"
Context: "c1auxey.martian:5064"
Source File: ../cac.cpp line 1214
Current Time: Mon Nov 18 2013 21:14:07.040168660
..................................................................
Could not connect to channel (timeout=2s): C1:SUS-ETMY_YAW_COMM
controls@rossa:/opt/rtcds/caltech/c1/medm/MISC/ifoalign/burt 1$
This is also causing trouble for the BURT save and BURT restore scripts, that are called from the IFO_ALIGN screen. If I look at the log that is written from an attempted 'save' of the slider values, I see:
**** READ BURT LOGFILE
--- Start processing files
file >/opt/rtcds/caltech/c1/medm/MISC/ifoalign/burt/ETMY.req<
preprocessing ... done
pv >C1:SUS-ETMY_PIT_COMM< nreq=-1
pv >C1:SUS-ETMY_YAW_COMM< nreq=-1
--- End processing files
--- Start searches
C1:SUS-ETMY_PIT_COMM ... ca_search_and_connect() ... OK
C1:SUS-ETMY_YAW_COMM ... ca_search_and_connect() ... OK
--- End searches
Waiting for 2 outstanding search(es) ...
Waiting for 2 outstanding search(es) ...
did not find 2
--- Start reads
C1:SUS-ETMY_PIT_COMM ... not connected so no ca_array_get_callback()
C1:SUS-ETMY_YAW_COMM ... not connected so no ca_array_get_callback()
--- End reads
--- Start wait for pending reads
-- End wait for pending reads 0 outstanding read(s)
**** END BURT LOGFILE
The burt save file has no values in it. Even if I copy over the ETMX save file and put in the correct channel names and values, a burt restore is unsuccessful.
So, I can do locking tonight by restoring and misaligning by hand, but this sucks, and needs to be fixed. Other optics (at least PRM, SRM, ETMX) seem to be working just fine. It's just ETMY that has a problem.
|
9401
|
Mon Nov 18 21:02:54 2013 |
Jenne | Update | LSC | PRM oplev measured and modeled TF | I have created a new filter for the PRM oplev damping loops. The biggest change is an increase in the gain between 0.4 - 7 Hz.
Here is a plot of the old, and my new modelled open loop gain:

When I look at my step and impulse response time series, the notches for the bounce and roll were causing some ringing, so for now they are turned off, both in the model and in the real time system. Also, the "OLG orig" trace has a 4th order elliptic lowpass at 75 Hz, but the real system had a 4th order elliptic low pass at 35 Hz. When we use 35 Hz in the model, we get lots of ringing. So, we have moved both model and real system to 55 Hz 4th order elliptic low passes. Also, also, we haven't been using the 3.3 Hz resonant gain, so I removed that from the modelled loop.
I have put the "boost" for the .4-7 Hz emphasis into FM 7 of the PRM oplev filters. I also removed several old filters that are never used. So, for now, the PRM oplevs should have engaged: FM 1, 7, 9. Pitch gain is +5, yaw gain is -9. We can consider re-implementing the bounce-roll notches, and the stack resgain if it looks like those are getting rung up, and causing trouble.
Here is a set of spectra, showing the improvement. It's unclear why yaw is worse than pitch below 4Hz, and why pitch is so much worse than yaw between 4-15 Hz, however for each of pitch and yaw, the before (reference pink and cyan traces) is higher than the improved (dark red, dark blue traces) between a few tenths of a Hz up to 3ish Hz. And, we're not causing more noise elsewhere. We do want to monitor to make sure we're not ringing up the bounce and roll modes, but for now they seem fine.

|
9400
|
Mon Nov 18 19:45:42 2013 |
RANA | Update | SUS | PRM pictures | Nice camera work Steve! I will use these for publicity photos.

Now we need to get one of the video cameras hooked into the MUX so that we can see the flashing and do some image subtraction. |
9399
|
Mon Nov 18 17:00:20 2013 |
Jenne | Update | SUS | PRM pictures | It crossed my mind that, from these pictures, it could be glow from the oplev scattered light that is causing the problem. However, that seems not possible, since the power fluctuations that we see depend on the presence of the IR light - if it were the oplev light, then when I close the PSL shutter, I should see the same amount of kick, which I don't. Also, the amount of fluctuation increases with increased stored power in the cavities. Also, also, Steve reminds me that some of the MC mirrors see similar kicks in their OSEM signals, but they don't have oplevs.
So, I don't believe that the oplev light is causing the problem, but I wanted to write down why I don't think that's it.
Investigations into OSEM and oplev loops to get rid of the kicks are continuing. |
9398
|
Mon Nov 18 16:39:38 2013 |
Steve | Update | SUS | PRM pictures | PRM is aligned. IFO is not locked. It is just flashing, including arms. Olympus SP570UZ camera used without IR blocker. Note: PRM side OSEM does not show IR effect.
I will take more pictures with IOO IR blocked and HeNe oplev blocked tomorrow morning. |
Attachment 1: PRM1.JPG
|
|
Attachment 2: PRMsurface.JPG
|
|
Attachment 3: PRM2.JPG
|
|
9397
|
Fri Nov 15 14:08:13 2013 |
manasa | Update | PSL | PSL Innolight shuts down again |
Quote: |
I have just turned on the PSL Innolight laser. The laser shut down with unknown reason a day ago.
|
PSL NPRO shut down again today for reasons unknown. I was working near the IOO rack and noticed there was no light at both the refl and trans PMC cameras. Jenne and I checked the PSL and found the 'OFF' red switch on the laser driver lit up. Switching ON the green button brought the laser back. PMC and MC autolocked after this. |
9396
|
Fri Nov 15 13:26:00 2013 |
Jenne | Update | CDS | AUXEY is back |
Quote: |
Quote: |
Please just try rebooting the vxworks machine. I think there is a key on the card or create that will reset the device. These machines are "embeded" so they're designed to be hard reset, so don't worry, just restart the damn thing and see if that fixes the problem.
|
This is what I remember doing all the time when Rob was around, but with all the new computers, I forgot whether or not this was allowed for the slow computers.
Anyhow, I went down there and keyed the crate, but auxey isn't coming back. I'll give it a few more minutes and check again, but then I might go and power cycle it again. If that doesn't work, we may have a much bigger problem.
|
I went and keyed the crate again, and this time the computer came back. I burt restored to Nov 10th. ETMY is damping again. |
9395
|
Fri Nov 15 12:38:50 2013 |
Jenne | Update | CDS | Can't talk to AUXEY? |
Quote: |
Please just try rebooting the vxworks machine. I think there is a key on the card or create that will reset the device. These machines are "embeded" so they're designed to be hard reset, so don't worry, just restart the damn thing and see if that fixes the problem.
|
This is what I remember doing all the time when Rob was around, but with all the new computers, I forgot whether or not this was allowed for the slow computers.
Anyhow, I went down there and keyed the crate, but auxey isn't coming back. I'll give it a few more minutes and check again, but then I might go and power cycle it again. If that doesn't work, we may have a much bigger problem. |
9394
|
Fri Nov 15 12:00:28 2013 |
Koji | Update | CDS | Can't talk to AUXEY? |
Quote: |
Please just try rebooting the vxworks machine. I think there is a key on the card or create that will reset the device. These machines are "embeded" so they're designed to be hard reset, so don't worry, just restart the damn thing and see if that fixes the problem.
|
Don't forget to run burtrestore for the target. |
9393
|
Fri Nov 15 10:49:55 2013 |
jamie | Update | CDS | Can't talk to AUXEY? | Please just try rebooting the vxworks machine. I think there is a key on the card or create that will reset the device. These machines are "embeded" so they're designed to be hard reset, so don't worry, just restart the damn thing and see if that fixes the problem. |
9392
|
Fri Nov 15 10:31:45 2013 |
Steve | Update | ISS | SR560 ISS loop connection |
Quote: |
Quote: |
We have implemented an SR560-based ISS loop using the AOM on the PSL table. This is a continuation of the work in 40m:9328.
We dumped the diffracted beam from the AOM onto a stack of razor blades. This beam is not terribly well separated from the main beam, so the razor blades are at a very severe angle. Any alternatives would have involved either moving the AOM or attempting to dump the diffracted beam somewhere on the PMC refl path. We trimmed the RF power potentiometer on the driver so that with 0.5 V dc applied to the AM input, about 10% of the power is diverted from the main beam.
We ran the PMC trans PD into an AC-coupled SR560. To shape the loop, we set SR560 to have a single-pole low- pass at 300 Hz and an overall gain of 5×104. We take the 600 Ω output and send it into a 50 Ω feed-through terminator; this attenuates the voltage by a factor of 10 or so and thereby ensures that the AOM driver is not overdriven.
The AOM driver's AM input accepts 0 to 1 V, so we add an offset to bias the control signal. The output of the 50 Ω feedthrough is sent into the 'A' input of a second SR560 (DC coupled, A − B setting, gain 1, no filtering). Using a DS345 function generator, a 500 mV offset is put into the 'B' input (the function generator reads −0.250 V because it expects 50 Ω input). The 50 Ω output of this SR560 is sent into the AOM driver's AM input.
A measurement of suppressed and unsuppressed RIN is attached. We have achieved a loop with a bandwidth of a few kilohertz and with an in-loop noise suppression factor of 50 from 100 Hz to 1 kHz. This measurement was done using the PMC trans PD, so this spectrum may underestimate the true RIN.
|
A small followup measurement. Here are spectra of the MC trans diode with and without the ISS on. The DC value of the diode (in counts) changed from 17264.2 (no ISS) to 17504.3 (with ISS), but I didn't account for this change in the plot.
There is a small inkling of benefit between 100Hz and 1kHz. Above about 100Hz, the RIN is suppressed to about the noise level of this measurement. Below 100Hz there is no change, which probably means that power fluctuations are introduced downstream of the AOM, which argues for an outer-loop ISS down the road.
Atm #2 is in units of RIN.
|
I have disconnected the cable from the SR560 to LSC -ch8 for 15minutes this morning. It is moved from the floor to the top of the chambers as preparation for 40m tour. The SR560 seems to be overloading.
The ISS servo is off according to the MEDM screen. Why MC-T plot showing zero? The MC was happy yesterday.
|
Attachment 1: ISS.png
|
|
9391
|
Fri Nov 15 10:19:26 2013 |
manasa | Update | CDS | Can't talk to AUXEY? |
Quote: |
This problem is now worse - the sliders on IFO_ALIGN for ETMY are white. I can't telnet to the machine either, although auxex works okay. Rather, it looks like maybe I'm getting to auxey, but then I'm immediately booted. I can ping both c1auxex and c1auxey with no problem.
Heeeeelllp please. Is this just a "shut off, then turn back on" problem? I'm wary of hard rebooting things, with all the warnings and threats in the elog lately. I've sent an email to Jamie to ping him.
There are some vague instructions in the wiki, but they begin at doing the burt restores, not actually restarting the computers: wiki Back in July, elog 8858 was written, from which the wiki instructions seem to be based. But in the elog it says "...went to the /cvs/cds/caltech/target/ area and started to (one by one) inspect all of the targets to see if they were alive.", but I don't know what "inspected" means in this case. I probably should, since I've been here for something like a millennia, but I don't.
|
This is what was done (as I recollect) when we said "inspected":Tenet into the computer, ping them and look at the status. Since c1auxey is not responding, here is how c1auxex responds.
controls@rossa:/cvs/cds/caltech/target 0$ telnet c1auxex
Trying 192.168.113.59...
Connected to c1auxex.martian.
Escape character is '^]'.
c1auxex > h
1 i
2 -help
3 --help
4 h
5 2
6 h
7 -help
8 i
9 h
value = 0 = 0x0
c1auxex > i
NAME ENTRY TID PRI STATUS PC SP ERRNO DELAY
---------- ------------ -------- --- ---------- -------- -------- ------- -----
tExcTask _excTask fde244 0 PEND 87094 fde1ac 3006b 0
tLogTask _logTask fdb944 0 PEND 87094 fdb8a8 0 0
tShell _shell ddad00 1 READY 6d974 dda9c8 3d0001 0
tRlogind _rlogind fbc11c 2 PEND 2b604 fbbdf4 0 0
tTelnetd _telnetd fba278 2 PEND 2b604 fba1a8 0 0
tTelnetOutT_telnetOutTa db7578 2 READY 2b604 db72e0 0 0
tTelnetInTa_telnetInTas db6060 2 READY 2b5dc db5d68 0 0
callback _callbackTas f7941c 40 PEND 2b604 f793d4 0 0
scanEvent ee7ca8 ecacb4 41 PEND 2b604 ecac6c 0 0
tNetTask _netTask fd75b8 50 READY 6be6c fd7550 0 0
scanPeriod ee78f8 ecd554 53 READY 6d192 ecd508 0 0
scanPeriod ee78f8 f23e48 54 DELAY 6d192 f23dfc 0 6
tFtpdTask _ftpdTask fb7848 55 PEND 2b604 fb778c 0 0
scanPeriod ee78f8 f266e8 55 READY 6d192 f2669c 0 0
scanPeriod ee78f8 f38678 56 READY 6d192 f3862c 0 0
callback _callbackTas f7bcbc 57 PEND 2b604 f7bc74 0 0
scanPeriod ee78f8 f906d8 57 DELAY 6d192 f9068c 0 59
scanPeriod ee78f8 f995ac 58 DELAY 6d192 f99560 0 238
scanPeriod ee78f8 f9c908 59 DELAY 6d192 f9c8bc 0 538
callback _callbackTas fa4c1c 65 PEND 2b604 fa4bd4 0 0
scanOnce ee7764 f9f96c 65 PEND 2b604 f9f92c 0 0
epicsPrint f0501c e88fa0 70 PEND 2b604 e88f64 c0002 0
ts_Casync ee5bae f76b7c 70 DELAY 6d192 f76880 3d0004 178
tPortmapd _portmapd fb8d60 100 PEND 2b604 fb8c2c 16 0
EgRam ea00e4 fa14ac 100 PEND 2b604 fa1458 0 0
CA client _camsgtask d85878 180 PEND 2b604 d85774 3d0004 0
CA client _camsgtask df91e8 180 PEND 2b604 df90e4 0 0
CA client _camsgtask d98bf4 180 PEND 2b604 d98af0 0 0
CA client _camsgtask e03cd0 180 PEND 2b604 e03bcc 0 0
CA client _camsgtask ddf2b8 180 PEND 2b604 ddf1b4 0 0
CA client _camsgtask faaec8 180 PEND 2b604 faadc4 0 0
CA client _camsgtask d79f3c 180 PEND 2b604 d79e38 0 0
CA TCP _req_server f305dc 181 PEND 2b604 f30540 0 0
CA repeaterf109e2 f215a8 181 PEND 2b604 f21474 0 0
CA event _event_task d7fe58 181 PEND 2b604 d7fe10 0 0
CA event _event_task d6ce5c 181 PEND 2b604 d6ce14 0 0
CA event _event_task dab7e0 181 PEND 2b604 dab798 0 0
CA event _event_task d76efc 181 PEND 2b604 d76eb4 0 0
CA event _event_task d9bddc 181 PEND 2b604 d9bd94 0 0
CA event _event_task d9a864 181 PEND 2b604 d9a81c 0 0
CA event _event_task da8d8c 181 PEND 2b604 da8d44 0 0
CA UDP _cast_server f2f064 182 READY efcabe f2efe4 0 0
CA online _rsrv_online f2d84c 183 DELAY 6d192 f2d7bc 0 265
EV save_res_event_task de88dc 189 PEND 2b604 de8894 3006b 0
save_restor_save_restor df61cc 190 PEND 2b604 df5c44 3d0002 0
RD save_res_cac_recv_ta fb47d8 191 READY 2b604 fb46a4 3d0004 0
logRestart f05d42 e861c0 200 PEND+T 2b604 e86174 33 1714
taskwd ef4d46 e85030 200 DELAY 6d192 e84f7c 0 224
value = 0 = 0x0
c1auxex >
telnet> quit
Connection closed.
controls@rossa:/cvs/cds/caltech/target 0$ |
9390
|
Fri Nov 15 09:27:58 2013 |
Koji | Update | IOO | WFS with beam dumps | Unfortunately this does not work. These WFSs are not the detectors which we can move freely.
In order to move the WFS detectors, we need the precise design of the Gouy phase for each WFS heads.
Without the design, we can't move the detectors. |
9389
|
Fri Nov 15 09:24:41 2013 |
Steve | Update | IOO | WFS with beam dumps | This is a proposal to move WFSs such way that their reflected beam can be trapped.
Later ps: Nic will take care of the Gouy phase telescopes. |
Attachment 1: MCwfsRefTraped.jpg
|
|
9388
|
Fri Nov 15 08:01:20 2013 |
Steve | Update | SUS | ETMY damping restored | ETMY sus damping restored |
Attachment 1: ETMYsus.png
|
|
9387
|
Thu Nov 14 22:23:22 2013 |
Jenne | Update | CDS | Can't talk to AUXEY? |
Quote: |
The restore scripts from the IFO config screen half-failed, with this error:
retrying (1/5)...
retrying (2/5)...
CA.Client.Exception...............................................
Warning: "Virtual circuit disconnect"
Context: "c1auxey.martian:5064"
Source File: ../cac.cpp line 1214
Current Time: Wed Nov 13 2013 17:24:00.389261330
..................................................................
Jamie, do you know what this might be? When requested, ETMY was not misaligned or restored, but we got these errors. So, somehow we're not talking properly to EY, but other things seem fine (the models are running okay, the suspension is damped, etc, etc.)
|
This problem is now worse - the sliders on IFO_ALIGN for ETMY are white. I can't telnet to the machine either, although auxex works okay. Rather, it looks like maybe I'm getting to auxey, but then I'm immediately booted. I can ping both c1auxex and c1auxey with no problem.
Heeeeelllp please. Is this just a "shut off, then turn back on" problem? I'm wary of hard rebooting things, with all the warnings and threats in the elog lately. I've sent an email to Jamie to ping him.
There are some vague instructions in the wiki, but they begin at doing the burt restores, not actually restarting the computers: wiki Back in July, elog 8858 was written, from which the wiki instructions seem to be based. But in the elog it says "...went to the /cvs/cds/caltech/target/ area and started to (one by one) inspect all of the targets to see if they were alive.", but I don't know what "inspected" means in this case. I probably should, since I've been here for something like a millennia, but I don't.
controls@rossa:~ 0$ telnet c1auxey
Trying 192.168.113.60...
Connected to c1auxey.martian.
Escape character is '^]'.
Connection closed by foreign host.
controls@rossa:~ 1$ telnet c1auxex
Trying 192.168.113.59...
Connected to c1auxex.martian.
Escape character is '^]'.
c1auxex >
telnet> ^]
?Invalid command
telnet> exit
?Invalid command
telnet> quit
Connection closed.
controls@rossa:~ 0$ telnet c1auxey
Trying 192.168.113.60...
Connected to c1auxey.martian.
Escape character is '^]'.
Connection closed by foreign host.
|
9386
|
Thu Nov 14 14:35:12 2013 |
Steve | Update | SUS | IR effect on MC and PRM sensors | Sorry to say but MC1, MC2, MC3 and PRM face OSEMS are having the same problem of leaking IR into the sensors
The PMC was not locked for 11 minutes on this plot.
|
Attachment 1: MC_PRM_IReffect.png
|
|
9385
|
Thu Nov 14 14:27:51 2013 |
nicolas | Omnistructure | General | SR785 Analyzer CRT replaced | The 785 analyzer in the 40 had a wonky hard to read screen. I was hoping that a new white CRT would fix all the problems.
I installed a white CRT, which didn't fix the wonkyness, but I adjusted the CRT position, brightness, focus settings to make the screen somewhat more readable.
BEFORE:

AFTER:

If we want to send the thing in for service to fix the wonkyness, we should probably hold on to the old CRT because they will probably replace the whole screen assembly and we'll lose our white screen. |
9384
|
Thu Nov 14 11:41:19 2013 |
Steve | Update | SUS | PRM sensors effected by IR | IR off for 11 minutes. The PRM face sensors are effected. The PRM side and the rest of the SUS OSEMS are not effected.
|
Attachment 1: IRon_off.png
|
|
9383
|
Thu Nov 14 02:55:26 2013 |
rana | Update | SUS | PRM motion correlated to intracavity power |
Some more words about the ISS -> OSEM measurement:
The calibration of the OSEMs have been done so that these channels are each in units of microns. The SIDE channel has the lower noise floor because Valera increased the analog gain by 5x some time ago and compensated with lower digital gain.
The peak heights in the plot are:
UL 0.85
LL 0.78
UR 0.61
LR 0.45
S 0.27
So that tells us that the coupling is not uniform, but mostly coming in from the left side (which side is the the SIDE OSEM on?).
Jenne and I discussed what to do to mitigate this in the loops. Before we vent to fix the scattering (by putting some covers around the OSEMs perhaps), we want to try to tailor the OSEM damping loops to reduce their strength and increase the strength of the OL loops at the frequencies where we saw the bulk of the instability last time.
Jenne is optimizing OL loops now, and I'm working on OSEM tweaking. My aim is to lower the overall loop gains by ~3-5x and compensate that by putting in some low Q, resonant gain at the pendulum modes as we did for eLIGO. We did it here at the 40m several years ago, but had some troubles due to some resulting instability in the MC WFS loops.
In parallel, Steve is brainstorming some OSEM shields and I am asking around LIGO for some AC OSEM Satellite modules. |
9382
|
Thu Nov 14 02:50:43 2013 |
Jenne | Update | LSC | PRM oplev measured and modeled TF | In the process of figuring out what we can do to fix our PRM motion problem, I am looking at the PRM oplev.
Eventually (as in, tomorrow), I'd like to be able to simulate some optic motion as a result of an impulse, and see what the oplev loops do to that motion. (For starters, I'll take the impulse response of the OSEM loop as my time series that the oplev loop sees).
One thing that I have done is look at the oplev model that Rana put together, which is now in the noisebudget svn: /ligo/svncommon/NbSVN/aligonoisebudget/trunk/OpLev/C1
This script plots the open loop gain of the modeled oplev:

This should be compared to the pitch and yaw measured transfer functions:


In the YAW plot, there are 2 transfer functions. The first time around, the UGF was ~2.5Hz, which is too low, so I increased the gain in the C1:SUS-PRM_OLYAW filter bank from -3 to -9.
The shapes of the measured and modeled transfer functions look reasonably similar, but I haven't done a plot overlay. I suspect that the reason I don't see the same height peak as in the model is just that I'm not taking a huge number of points. However, if the other parts of the TF line up, I'll assume that that's okay.
I want to make sure that the modeled transfer function matches the measured ones, so that I know I can trust the model. Then, I'll figure out how to use the time series data with the simulated loop. Ideally, I'd like to see that the oplev loop can fully squish the motion from the OSEM kicks. Once I get something that looks good (by hand-tweaking the filter shape), I'll give it a try in the actual system. We should, as soon as I get the optimal stuff working, redo this in a more optimal way. Both now, and after I get an optimal design, I'll look at the actual step and impulse responses of the loop, to make sure there aren't any hidden instabilities.
Other thoughts for the night:
Rana suggests increasing the gain in some of the oplev QPD heads (including PRM), so that we're getting more than a few hundred counts of power on each quadrant. Since our ADCs go to 32,000 counts, a few hundred is very small, and keeping us close to our noise limits.
Also, just an observation, but when I watch the REFL camera along with POP and AS, it's clear that the PRM is getting kicked, and I don't have the ETMs aligned right now, so this is just PRMI flashes. There is also a lot of glow in the BS chamber during flashes (as seen on the PRM face video camera). |
9381
|
Thu Nov 14 00:33:37 2013 |
rana | Configuration | PSL | PMC LO is dying... | Back in 2009, Jenne replaced the PMC board mixer with a Level 13 one. Today I noticed that the LO level on the PMC screen was showing a LO level of ~5-10 dBm and fluctuating a lot. I think that it is related to the well known failure of the Mini-Circuits ERA-5SM amplifier which is on the D000419-A schematic (PMC Frequency Reference Card). The Hanford one was dying for 12 years and we found it in late 2008. If we don't have any in the blue bin, we should ask Steve to order 10 of them.
The attached trend shows 2000 days of hour trend of the PMC LODET channel. The big break in 2009 is when Jenne changed the mixer and then attenuated the input by 3 dB. The slow decay since then is the dying amplifier I guess.
Since the LOCALC channel was not in the trend, I added it to the C0EDCU file tonight and restarted the FB DAQD process. Its now in the dataviewer list.
I went out and took out the 3 dB attenuator between the LO card and the PMC Mixer. The LO monitor now reads 14.9 dBm (??!!). The SRA-3MH mixer data sheet claims that the mixer works fine with an LO between 10 and 16 dBm, so I'll leave it as is. After we get the ERA-5, lets fix the LODET monitor by upping its gain and recalibrating the channel. |
Attachment 1: Untitled.png
|
|
9380
|
Wed Nov 13 20:02:12 2013 |
Nic, Evan | Update | ISS | SR560 ISS loop |
Quote: |
We have implemented an SR560-based ISS loop using the AOM on the PSL table. This is a continuation of the work in 40m:9328.
We dumped the diffracted beam from the AOM onto a stack of razor blades. This beam is not terribly well separated from the main beam, so the razor blades are at a very severe angle. Any alternatives would have involved either moving the AOM or attempting to dump the diffracted beam somewhere on the PMC refl path. We trimmed the RF power potentiometer on the driver so that with 0.5 V dc applied to the AM input, about 10% of the power is diverted from the main beam.
We ran the PMC trans PD into an AC-coupled SR560. To shape the loop, we set SR560 to have a single-pole low- pass at 300 Hz and an overall gain of 5×104. We take the 600 Ω output and send it into a 50 Ω feed-through terminator; this attenuates the voltage by a factor of 10 or so and thereby ensures that the AOM driver is not overdriven.
The AOM driver's AM input accepts 0 to 1 V, so we add an offset to bias the control signal. The output of the 50 Ω feedthrough is sent into the 'A' input of a second SR560 (DC coupled, A − B setting, gain 1, no filtering). Using a DS345 function generator, a 500 mV offset is put into the 'B' input (the function generator reads −0.250 V because it expects 50 Ω input). The 50 Ω output of this SR560 is sent into the AOM driver's AM input.
A measurement of suppressed and unsuppressed RIN is attached. We have achieved a loop with a bandwidth of a few kilohertz and with an in-loop noise suppression factor of 50 from 100 Hz to 1 kHz. This measurement was done using the PMC trans PD, so this spectrum may underestimate the true RIN.
|
A small followup measurement. Here are spectra of the MC trans diode with and without the ISS on. The DC value of the diode (in counts) changed from 17264.2 (no ISS) to 17504.3 (with ISS), but I didn't account for this change in the plot.
There is a small inkling of benefit between 100Hz and 1kHz. Above about 100Hz, the RIN is suppressed to about the noise level of this measurement. Below 100Hz there is no change, which probably means that power fluctuations are introduced downstream of the AOM, which argues for an outer-loop ISS down the road.
Atm #2 is in units of RIN. |
Attachment 1: ISS_560_rot.pdf
|
|
Attachment 2: ISS_560cal.pdf
|
|
9379
|
Wed Nov 13 19:41:55 2013 |
Jenne | Update | ISS | ISS AOM | AOM driving from DAC:
I found that the DAC channels for TT3 and TT4 are connected up in the simulink model, but we aren't using them, since we don't actually have those tip tilts installed. So, we hooked up the TT4 LR DAC output, which is channel 8 on the 2nd set of SMA outputs. We put our AOM excitations into TT4_LR_EXC.
|
9378
|
Wed Nov 13 19:22:58 2013 |
Jenne | Update | LSC | PRM motion correlated to intracavity power | [Gabriele, Jenne]
Nic and Evan put the ISS together (elog 9376), and we used an injection into the error point (?) to modulate the laser power before the PMC (The AOM had a bias offset, but there is no loop). This gives us some RIN, that we can try to correlate with the PRM OSEM sensors.
We injected several lines, around 100, 200, 500 and 800 Hz. For 100, 200 and 800 Hz lines, we see a ratio between POPDC and the OSEM sensors of 1e-4, but at 500 Hz, the ratio was more like 1e-3. We're not sure why this ratio difference exists, but it does. These ratios were true for the 4 face OSEMs. The side OSEM saw a slightly smaller signal.
For these measurements, the PRMI was sideband locked, and we were driving the AOM with an amplitude of 10,000 counts (I don't know what the calibration is between counts and actual drive, which is why we're looking at the POPDC to sensor *ratio*).
To get a more precise number, we may want to consider locking the PRMI on carrier, so we have more power in the cavity, and so more signal in the OSEMs.
These ratios look, by eye, similar to the ratios we see from the time back on 30 Oct when we were doing the PRMI+2arms test, and the arms were resonating about 50 units. So, that is nice to see some consistency.

This time series is from 1067163395 + 27 seconds, from 30 Oct 2013 when we did the PRMI+2arms.

Ideas to go forward:
We should think about chopping the OSEM LEDs, and demodulating the PD sensors.
We should also take a look in the chamber with a camera from the viewport on the north side of the BS chamber, to see if we see any flashes in the chamber that could be going into the OSEMs, to see where we should maybe put aluminum foil shields. |
9377
|
Wed Nov 13 18:37:19 2013 |
rana | Configuration | Electronics | DAC available in c1lsc IO chassis for DAFI |
The first picture shows that there is indeed a DAC next to the ADC in the LSC IO chassis. The second picture shows how there are two cables, each one carrying 8 channels of DAC. The third one shows how these come out of the coil drivers to handle the Tip/Tilt mirrors which point the beam from the IMC into the PRC. It should be the case that the second Dewhitening filter board can give us access to the next 8 channels for use in driving an audio signal into the control room or an ISS excitation. |
9376
|
Wed Nov 13 18:32:04 2013 |
Nic, Evan | Update | ISS | SR560 ISS loop | We have implemented an SR560-based ISS loop using the AOM on the PSL table. This is a continuation of the work in 40m:9328.
We dumped the diffracted beam from the AOM onto a stack of razor blades. This beam is not terribly well separated from the main beam, so the razor blades are at a very severe angle. Any alternatives would have involved either moving the AOM or attempting to dump the diffracted beam somewhere on the PMC refl path. We trimmed the RF power potentiometer on the driver so that with 0.5 V dc applied to the AM input, about 10% of the power is diverted from the main beam.
We ran the PMC trans PD into an AC-coupled SR560. To shape the loop, we set SR560 to have a single-pole low- pass at 300 Hz and an overall gain of 5×104. We take the 600 Ω output and send it into a 50 Ω feed-through terminator; this attenuates the voltage by a factor of 10 or so and thereby ensures that the AOM driver is not overdriven.
The AOM driver's AM input accepts 0 to 1 V, so we add an offset to bias the control signal. The output of the 50 Ω feedthrough is sent into the 'A' input of a second SR560 (DC coupled, A − B setting, gain 1, no filtering). Using a DS345 function generator, a 500 mV offset is put into the 'B' input (the function generator reads −0.250 V because it expects 50 Ω input). The 50 Ω output of this SR560 is sent into the AOM driver's AM input.
A measurement of suppressed and unsuppressed RIN is attached. We have achieved a loop with a bandwidth of a few kilohertz and with an in-loop noise suppression factor of 50 from 100 Hz to 1 kHz. This measurement was done using the PMC trans PD, so this spectrum may underestimate the true RIN. |
Attachment 1: psl_aom_overhead.jpg
|
|
Attachment 2: aom_driver.jpg
|
|
Attachment 3: loop_on_settings.jpg
|
|
Attachment 4: fxn_gen.jpg
|
|
Attachment 5: 40m_iss.pdf
|
|
9375
|
Wed Nov 13 18:02:08 2013 |
Jenne | Update | CDS | Can't talk to AUXEY? | The restore scripts from the IFO config screen half-failed, with this error:
retrying (1/5)...
retrying (2/5)...
CA.Client.Exception...............................................
Warning: "Virtual circuit disconnect"
Context: "c1auxey.martian:5064"
Source File: ../cac.cpp line 1214
Current Time: Wed Nov 13 2013 17:24:00.389261330
..................................................................
Jamie, do you know what this might be? When requested, ETMY was not misaligned or restored, but we got these errors. So, somehow we're not talking properly to EY, but other things seem fine (the models are running okay, the suspension is damped, etc, etc.) |
9374
|
Wed Nov 13 11:30:07 2013 |
Steve | Update | PEM | particle counter MOVED | Particle counter moved from the top of IOOC to the east wall |
Attachment 1: Met1Moved.JPG
|
|
|