Entry  Mon Mar 21 16:49:11 2011, kiwamu, Summary, Green Locking, plan for this week 
Entry  Mon Mar 21 18:34:10 2011, kiwamu, Update, Green Locking, added a new ADC channel on 1X9 aa_board_1X9.jpg
    Reply  Tue Mar 22 00:01:25 2011, kiwamu, Summary, Green Locking, plan for daytime tasks 
Entry  Tue Mar 22 00:03:29 2011, Bryan, Configuration, Green Locking, PSL vs Y arm laser temperature pairing PSL_vs_Y_arm_Temperatures.png
    Reply  Tue Mar 22 00:23:20 2011, Jenne, Configuration, Green Locking, PSL vs Y arm laser temperature pairing 
Entry  Tue Mar 22 16:39:51 2011, kiwamu, Update, Green Locking, comaprator installed : 80 pm residual displacement noise_curve20110322.png
    Reply  Tue Mar 22 19:03:45 2011, Bryan, Configuration, Green Locking, PSL vs Y arm laser temperature pairing 
Entry  Wed Mar 23 00:51:47 2011, kiwamu, Update, Green Locking, plan for tomorrow 
Entry  Wed Mar 23 05:11:08 2011, kiwamu, Update, Green Locking, servo handig off stripTransit_edit.pngnoise_curve20110322_hUGF.png
    Reply  Wed Mar 23 08:50:36 2011, Aidan, Update, Green Locking, servo handig off green-to-red.jpg
Entry  Wed Mar 23 19:16:17 2011, Aidan, Summary, Green Locking, Y-END green equipment is all available three-quarter_inch_pedestal.jpg
    Reply  Thu Mar 24 01:16:19 2011, Suresh, Summary, Green Locking, Y-END green equipment is all available 
Entry  Thu Mar 24 13:50:30 2011, Bryan, Configuration, Green Locking, Y arm laser IMG_0188.JPGIMG_0190.JPG
    Reply  Thu Mar 24 15:30:59 2011, Bryan, Configuration, Green Locking, PSL vs Y arm laser temperature pairing Temp_Beating_Day02_html_m2d719182.jpg
    Reply  Thu Mar 24 16:33:32 2011, Bryan, Configuration, Green Locking, PSL vs Y arm laser temperature pairing PSL_vs_X-end_T_data_fine.jpg
Entry  Thu Mar 24 19:48:13 2011, Aidan, Kiwamu, Update, Green Locking, Designs for permanent electronics for ALS GreenLockingElectronics.pdfGreenEndPDHsupportboxandLO.pdfVertexBeatnoteAmplifierandComparator.pdfMixerFrequencyDiscriminator.pdf
Entry  Fri Mar 25 01:27:29 2011, mevans, Frogs, Green Locking, digital frequency counting 
    Reply  Fri Mar 25 11:16:19 2011, josephb, Frogs, Green Locking, digital frequency counting C1GFD.png
Entry  Mon Mar 28 16:24:35 2011, kiwamu, Update, Green Locking, power budget on PSL table RFPD.png
Entry  Mon Mar 28 17:06:15 2011, kiwamu, Update, Green Locking, a mixer school mixers.png
    Reply  Mon Mar 28 18:13:32 2011, rana, Update, Green Locking, a mixer school 
    Reply  Mon Mar 28 18:22:43 2011, kiwamu, Update, Green Locking, a mixer school 
Entry  Wed Mar 30 19:43:33 2011, Bryan, Configuration, Green Locking, The wonderful world of mode-matching 
    Reply  Wed Mar 30 19:54:19 2011, Bryan, Configuration, Green Locking, The wonderful world of mode-matching laser_output_non_circular.png
    Reply  Wed Mar 30 20:08:34 2011, Bryan, Configuration, Green Locking, The wonderful world of mode-matching Beam_Matching_02c_Vertical.pngBeam_Matching_02c_Horizontal.png
    Reply  Wed Mar 30 20:14:17 2011, Bryan, Configuration, Green Locking, The wonderful world of mode-matching 
    Reply  Wed Mar 30 20:31:30 2011, Bryan, Configuration, Green Locking, The wonderful world of mode-matching 
    Reply  Wed Mar 30 20:50:43 2011, Bryan, Configuration, Green Locking, The wonderful world of mode-matching After_Faraday.pngAfter_Faraday_and_Rotated_Lens.png
    Reply  Wed Mar 30 21:21:15 2011, Bryan, Configuration, Green Locking, The wonderful world of mode-matching Oven_Lens_Solution_66mm.pngMatching_Into_Green_Oven_zoomed_out.pngMatching_Into_Green_Oven_zoomed_in.png
Entry  Wed Mar 30 21:43:31 2011, Aidan, Kiwamu, Summary, Green Locking, Calculation of the green contrast on the RF PD 
Entry  Wed Mar 30 21:46:10 2011, Aidan, Kiwamu, Update, Green Locking, States of the Green beat note 
    Reply  Thu Mar 31 02:59:49 2011, Koji, Configuration, Green Locking, The wonderful world of mode-matching 
    Reply  Thu Mar 31 14:10:00 2011, Bryan, Configuration, Green Locking, The wonderful world of mode-matching P3310028.JPGP3310029.JPG
    Reply  Thu Mar 31 15:23:14 2011, Bryan, Configuration, Green Locking, The wonderful world of mode-matching Zoomed_out_fitting01.pngZoomed_in_fitting01.png
Entry  Thu Mar 31 20:37:10 2011, Aidan, Summary, Green Locking, RF amplitude source P1000543.jpgP1000544.jpgP1000545.jpg
Entry  Thu Mar 31 20:46:11 2011, Aidan, Summary, Green Locking, Green beat note PD DC response 
Entry  Fri Apr 1 18:54:41 2011, Bryan, Configuration, Green Locking, Y end doubling oven P4010036.JPGP4010041.JPG
Entry  Fri Apr 1 23:05:58 2011, kiwamu, Update, Green Locking, noise budget noise_budget.png
    Reply  Fri Apr 1 23:49:24 2011, kiwamu, Summary, Green Locking, two states in green beat-note 
    Reply  Mon Apr 4 14:20:32 2011, Bryan, Configuration, Green Locking, The wonderful world of mode-matching Waist_Fits_from_laser.pngWaist_Fits_Bench_Position.png
Entry  Mon Apr 4 18:58:44 2011, Bryan, Configuration, Green Locking, A beam of purest green P4040042.JPG
Entry  Tue Apr 5 19:54:39 2011, Koji, Summary, Green Locking, Hamamatsu S3399 test S3399_test_110405.pngS3399_test_110405.pdf
Entry  Tue Apr 5 21:20:11 2011, Koji, Summary, Green Locking, X-arm cavity locked with LB1005 servo box servo.pngOLTF.pdf
    Reply  Wed Apr 6 02:41:01 2011, kiwamu, Update, Green Locking, noise budget : some more noise  noise_budget.png
Entry  Wed Apr 6 19:36:32 2011, Aidan, Summary, Green Locking, (In)sanity check of Green PD - some inconsistencies PD_measurement.pngplot_PD_RF_ratios.pdf
Entry  Wed Apr 6 22:13:24 2011, Bryan, Configuration, Green Locking, Resonating green light! 
    Reply  Thu Apr 7 16:09:17 2011, Aidan, Summary, Green Locking, (In)sanity check of Green PD - some inconsistencies 
    Reply  Thu Apr 7 19:28:02 2011, Koji, Summary, Green Locking, (In)sanity check of Green PD - some inconsistencies SGD-444A.png
Entry  Thu Apr 7 21:58:57 2011, Aidan, Summary, Green Locking, Beat note amplitude 
Entry  Sun Apr 10 19:14:08 2011, Koji, Update, Green Locking, New Green PD test1 SGD444A_240.pngSGD444A_240_test.png