40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 156 of 341  Not logged in ELOG logo
ID Date Authorup Type Category Subject Text Attachments
  11608   Thu Sep 17 02:22:53 2015 SteveUpdateendtable upgradeETMY optical table feedthroughI doubt we'll see any effect until
we carefully seal the holes. If there's
1 hole in your boat it still sinks.
  
  11610   Thu Sep 17 08:36:14 2015 SteveUpdatePEMearth quakeNo damage. The BS sensor UR 0.220 V has
been low for some times.

Dataviewer does not work for long
 Chilian_eq_8.3M.pngBS_UR_0.220V.pngLowSensingV_BS-UR.png 
  11612   Thu Sep 17 16:04:09 2015 SteveUpdatePEMGurs ETMY - Guralp (B-MIT) was covered with
copper lined can yesterday afternoon. It's
long cable is connected to ADC interface
  
  11625   Mon Sep 21 11:12:14 2015 SteveUpdateVACcold cathode is flakyCC4 cold cathode gauge jump triggered interlock
to close VM1 valve to protect the RGA.

The IFO pressure is 1e-5 Torr
 cc4jumps.png 
  11633   Tue Sep 22 08:58:38 2015 SteveUpdateVACcold cathode is flakyThe cold cathode gauge is back to normal.
cc4 is the last gauge is "functioning"

MKS is not responding. The spare
 4and80days.png 
  11642   Fri Sep 25 11:08:33 2015 SteveUpdateSUSwire standoffsOur last effort to change the existing
Al-6061 wire standoffs was at April 2012

We requested sapphire and/or ruby
 wireStandOff_SOS.PDF 
  11643   Fri Sep 25 14:52:08 2015 SteveUpdateSUSETMX is not driftingWe have talked about the drift of ETMX
sus on the Wednesday meeting.

It has stopped moving on Jan 8,
 ETMXstoppedDrifting.png25daysArmsT.png 
  11644   Fri Sep 25 17:00:38 2015 SteveUpdateVACcold cathode is flakyThe IFO pressure is estimated ~1E-6 Torr
with modified Vac normal valve configuration.

CC4 is in a jumping mode between
 flakyCC4.png 
  11654   Wed Sep 30 15:44:06 2015 SteveUpdateGeneralSun Fire X4600Gautam and
Steve,

The decommissioned server
  
  11659   Fri Oct 2 15:11:08 2015 SteveUpdatePEMcable squashedCable numbered #53 from Accelerometer 4
to 1X7 / DAQ input c26 was squased while
removing network card from Sun Fire x4600
  
  11660   Fri Oct 2 15:33:09 2015 SteveUpdatesafetysafety trainingGautom
has received 40m specific basic safety training
today.
  
  11666   Mon Oct 5 10:11:35 2015 SteveUpdateVACRGA scan pd78 day 386RGA background scan.

The IFO is closed off from RGA
with VM1
 RGA_background.png 
  11668   Mon Oct 5 16:41:22 2015 SteveUpdateSUSETMY OL laser replacedThis JDSU 1103P laser, sn P892324 lived
for 2 years. It's power output is 0.05
mW now
  
  11695   Fri Oct 16 18:27:52 2015 SteveUpdateVAC vacuum normal conditionVacuum normal configuration with VM1-closed,
VM2-open valve positions. Power load normal
24V 0.2A
 oct16Fpm2015.png 
  11705   Wed Oct 21 10:03:15 2015 SteveUpdateVACafter running out of N2 




 1d_after_reboot.png 
  11706   Wed Oct 21 15:42:56 2015 SteveUpdateVACvacuum gauge checkConvectron gauge check:

Brand new 10 years old convectron
gauge at atm was swapped into the place of
 Gauges.png 
  11707   Thu Oct 22 08:52:04 2015 SteveUpdateVACclean RGA scan after sweaty MaglevClean comparable scan at vacuum normal.
There was no backstreaming.
 clean_scan.png 
  11708   Fri Oct 23 09:55:50 2015 SteveUpdateLSCstable days   stable4days.png 
  11719   Tue Oct 27 10:08:12 2015 SteveUpdateVAC CC vacuum gaugesCC1 and CC2 are working again. Why did
they start working  again ?

 
 gauges_5y_vs_8d.png13.9yCC1&4.png 
  11724   Fri Oct 30 17:49:27 2015 SteveUpdateSUSETMX kicked upThe oplev and  the LSC are off.  ETMXkicking.pngETMXkickedbyOpPerror.pngETMXstillKicking.pngETMXkickingCond.png7hrsETMX-Y.png 
  11728   Wed Nov 4 08:04:53 2015 SteveUpdatesafetysafety trainingYutaro Enamoto, visiting graduate student
of Seiji received 40m specific basic safety
training.
 Yutaro.jpg 
  11730   Wed Nov 4 15:48:58 2015 SteveUpdatePEMETMX wirestadoff vs EQETMX was not much effected by this 8.3
M Chilian earthquake. It was kicked up and
it was kicking for hours after it. This is
 8.3mChili.png 
  11739   Mon Nov 9 09:27:44 2015 SteveUpdatePSLMC is not happyI just turned off the PSL enclousure lights.
 
 ioo8d.png 
  11755   Thu Nov 12 09:15:56 2015 SteveUpdateSUSITMX osemsThe ITMX OSEMS are oscillating.  ITMX.png 
  11756   Thu Nov 12 09:41:02 2015 SteveUpdatePSLPMCThe PMC is not happy and the ITMX UL OSEM
is moving too much

 
 PMC_ITMX.png 
  11757   Thu Nov 12 10:22:33 2015 SteveUpdatePEMpossible vibration for 4days Building:        
San Pasqual walkway East to West

                 
  
  11760   Fri Nov 13 15:20:24 2015 SteveUpdateSUSOSEMsAre they oscillating or not ?




 OSEMs.pngPOSbiasOFF.png 
  11771   Tue Nov 17 10:06:53 2015 SteveUpdateGeneralwater leak in east arm


 eastArmLeakyPipeInsideWall.jpgwd18ft.jpg 
  11830   Tue Dec 1 10:52:52 2015 SteveUpdateGeneralDataviewerDataviewer x axis end is not there.

On ( 2600 days) longer plots it
is missing 8 moths and on (100 days) shorther
 xAxisEndMissing.png 
  11832   Tue Dec 1 16:55:04 2015 SteveUpdateVACDataviewer fixedQ adjusted the Dataviewer so it is not
chopping of data any more. Thanks.

 
 10yrsCC1&4M.png 
  11858   Mon Dec 7 11:17:51 2015 SteveUpdateVACnoisy RGA scan at day 433 




 433dRGAscan.png 
  11863   Tue Dec 8 15:40:48 2015 SteveUpdateVACglitchy RGA scan at day 434The noise floor of the Rga scan is glitching
less today

 
 lessGlichingToday.png 
  11866   Wed Dec 9 11:25:55 2015 SteveUpdateVACnormal RGA scan at day 435-436Glitches are gone. Rga scan is good

 
 glichesGone.pngd436.png 
  11878   Mon Dec 14 14:08:49 2015 SteveUpdateSUSRuby wire standoffs updateTwo companies are willing to  make
the ruby grooves and the third one is still
working on their quote.
  
  11885   Wed Dec 16 10:22:14 2015 SteveUpdateIOOthis morningc1sus and c1ioo were restarted. PMC locked.
 
 PMClocked.png 
  11895   Mon Dec 21 14:31:41 2015 SteveUpdatePEMRat traps setTwo mechanical and two sticdky traps were
set to catch univited visitor.

Absolutely
 ratsNC.jpg 
  11897   Tue Dec 22 16:39:42 2015 SteveUpdateendtable upgradeETMY optical table enclosureI think there should be a scientifically
based aveluation of the ETMY enclosure so
we can make the ETMX better.
 IMG_0028.JPGIMG_0027.JPGETMY-ISCT_EISOL.jpg 
  11902   Sat Dec 26 10:34:43 2015 SteveUpdateGeneraltodayPMC locked manually and PRM sus damping
restored.
 1d.png 
  11903   Mon Dec 28 14:12:23 2015 SteveUpdateSUS4.2M EQSuspensions are recovered after 4.2 Mag
earth quake. No obvoius sign of damage.

 
 4.2Meq.pngrecovered4.2M.png 
  11904   Wed Dec 30 11:09:52 2015 SteveUpdateSUS4.4M EQSuspensions recovered after 4.4 Mag EQ

 
 4.4MeqDevore.pngfree.png 
  11909   Tue Jan 5 09:48:52 2016 SteveUpdatePEMRat trap moved Our janitor confirmed that Q was not hallucinating
about this animal. The dropping size indicating
a good size one in the IFO room.
  
  11911   Tue Jan 5 15:48:16 2016 SteveUpdatesafetyRat trap locations Please look around when working close to
these five locations. Use flashlights or
leave lights on.
 Control_Room.jpgEarmCESdoor.jpg1Y1.jpgMC2.jpgXarmMaglev.jpg 
  11914   Wed Jan 6 08:09:04 2016 SteveUpdatePEM4.5 Mag Banning EQIFO restored after 4.5 Mag Banning, Ca
earthquake.
 4.5Mag__Banning.png 
  11915   Wed Jan 6 10:58:03 2016 SteveUpdateGeneral projector light bulb is outProjector light bulb ordered




  
  11927   Tue Jan 12 07:54:23 2016 SteveUpdateSUSETMX damping restoredPMC locked and ETMX suspension damping
restored.
  
  11928   Tue Jan 12 08:40:06 2016 SteveUpdatePEMAir cond maintenanceAir condition maintenance is happening.
It should be done by 10am
  
  11932   Thu Jan 14 13:44:05 2016 SteveUpdateSUS earthquake 3.6M No obvious sign of damage.

 
 3.6M_JohannesburgCA.pngETMX_3.6_M.png 
  11935   Tue Jan 19 10:25:53 2016 SteveUpdateSUSEQ 3.6M LudlowJust an other local earthquake 3.6 Mag
Ludlow, Ca

No obvious sign of damage
 EQ_3.6M_Ludlow.png 
  11939   Wed Jan 20 09:36:11 2016 SteveUpdateSUSETMX damping restoredETMX suspension damping restored.

 
 EQ.png 
  11948   Mon Jan 25 08:36:46 2016 SteveUpdateSUSPRM damping restoredPRM suspension damping restored after 4.1
Mag Ludlow earthquake.

 
 EQ4.1mLudlow.pngEQ7.1mAlaska_4.1mLudlow.png7.1_4.1.png 
ELOG V3.1.3-