Entry  Tue Sep 23 15:28:06 2008, pete, Configuration, PSL, new 21.5 MHz FSS reference installed fss_ref_001.jpgfss_ref_013.jpg
The new 21.5 MHz FSS reference is now installed in the rack with the 7 Sorensen PS.  Both outputs give 18.7 dBm.  The MC seems happy.

Bob did the +24 V and +15 V hookups for the amp and the Wenzel oscillator respectively, off of the din strips on the right of the rack. 
Entry  Tue Sep 23 13:25:07 2008, rob, Update, Locking, a bit better 
I've been spending time working on the short DOF loops (PRC,MICH,SRC) in an attempt to make the 
initial stage of lock acquisition (the DRMI+2ARMs, no spring) better.  This seems to have been 
largely successful, as last night there were several locks of the DRMI+2ARMs with pretty short 
Entry  Tue Sep 23 11:17:59 2008, steve, Update, PSL, PMC scattering spot rainbow.pngpmcclip.png
The PMC output side has a new madly scattering spot at chamfer 2 o'clock position
Entry  Mon Sep 22 16:51:27 2008, Yoichi, HowTo, Computers, Network GPIB 
I was able to make the wireless connected GPIB interface work with SR785.
Now you can download data from SR785 through network, wherever it is located. 
Say good bye to floppy disks.
    Reply  Tue Sep 23 00:47:24 2008, Yoichi, HowTo, Computers, Network GPIB 
[quote]
I wrote a new script called "netgpibdata.py" which works similarly as "getgpibdata.py".
It is in the 40m svn. Instructions on how to use it is on the above mentioned wiki page.
Entry  Mon Sep 22 21:30:06 2008, rana, Configuration, PSL, bad FSS DAQ.png
The MC refl power was going up and the FSS PC drive was so large that I had to turn up the FSS
common gain from 1.5 dB to 10.5 dB to get it to be better. Attached are the before (REF) and
after plots of frequency noise. Is the FSS gain really supposed to be 1.5 dB?? How did we gain
    Reply  Mon Sep 22 22:24:19 2008, rana, Configuration, PSL, bad FSS 
[quote]The MC refl power was going up and the FSS PC drive was so large that I had to turn up the FSS...[/quote]

Looks like I bumped the PS for the 21.5 MHz test setup and changed the supply voltage of the amplifier
Entry  Mon Sep 22 21:54:05 2008, rana, Update, ASS, New Wiener result with x10 gain in ACC f.pdf
The 2 attached PDF files show the performance of the Wiener filter code on 2 hours of data
with a 4000 tap filter on 64 Hz data. All 6 accelerometers around the MC and the Ranger seismometer
were used.
Entry  Mon Sep 22 20:00:35 2008, Alberto, Update, General, ABSL: running measurement 
I'm leaving the X arm locked on the TEm01 mode while a measurement is running. Just please wait for 40 minute if you need the interferometer tonight.
Entry  Mon Sep 22 18:54:54 2008, Jenne, Update, PSL, PMC transfer functions with various brick-on-top configurations PMC_OLG_100Hz_to_100kHz.pngPMC_OLG_5kHz_to_30kHz.png
Attached below is a graphical summary of different things that I have tried putting on the PMC to reduce the noise in the loop.  The motivation behind these
measurements is the current inability here at the 40m to increase the UGF of the PMC.  This is part of a broader ISS loop/gain/noise problem that we are
having, which is causing Rob's locking efforts to have trouble.  (The ISS is next on the to-do list, after we find the best configuration for the PMC,
Entry  Mon Sep 22 15:02:45 2008, rana, Frogs, Treasure, Mantis found outside the 40m door at night mantis.JPG
 
Entry  Mon Sep 22 12:06:58 2008, rob, Update, SUS, ITMY UL OSEM 


Last week I found the ITMY UL OSEM dead.  I went around and checked the connections on the various flat ribbon cables 
Entry  Fri Sep 19 11:48:14 2008, steve, Update, Computers, old hubs can make one happy P1020934.jpg
Joseph finds a XIX century bottle neck hub: CentreCOM 3624TR 10Base-T 
and happily replaces it with Netgear GS724T 1000Base-T 
Entry  Fri Sep 19 11:21:45 2008, josephb, Configuration, Computers, Nameserver and Rosalba 
I tried modifying the nsswitch.conf file to include going to dns in addition to local files for everything (services, network, etc) and then moving the
/etc/hosts file to /etc/hosts.bak.  Unfortunately, this still didn't allow front-ends to reboot properly.  So I'm not sure what is using the hosts file,
but whatever it is, is apparently important.  After the test I placed the hosts file back and reverted the nsswitch.conf file.
Entry  Fri Sep 19 00:18:14 2008, rana, Update, Computers, svn is old 
[CODE]linux2:mDV>ssh nodus
Password:
Last login: Fri Sep 19 00:11:44 2008 from gwave-69.ligo.c
    Reply  Fri Sep 19 09:49:42 2008, Yoichi, Update, Computers, svn is old 
The problem below is fixed now.
The cause was .svn/entries and .svn/format had wrong version number "9" where it had to be "8".
I changed those files in all the sub-directories. Now svn up runs fine.
Entry  Fri Sep 19 08:09:55 2008, steve, Update, PSL, psl HEPAs turned on 
I have just turned on the PSL HEPA filters at 60% operational speed.
Entry  Fri Sep 19 01:55:41 2008, rana, Summary, SUS, SUS Drift Screen Updated infection-3.pngsetsvals.msetHILO.m
I wrote 2 matlab scripts to update the SUS DRIFT screen:

[CODE]- setsval.m   uses mDV to get the minute trend from some specified start time
Entry  Fri Sep 19 00:06:54 2008, rana, Update, IOO, MC_F: Too much frequency noise around 100 Hz mcf.png
WE noticed this excess again in MC_F. We tried recentering the WFS, but no effect.

Also no effect from changing the FSS gain, [COLOR=orange]PMC gain[/COLOR], or ISS gain.
Entry  Thu Sep 18 23:31:26 2008, rana, Update, PSL, ISS: Saturating too often at nominal gain FIRE_BLOWER.jpg
The ISS has been saturating whenever the MC relocks and puts the gain up to +8dB. I have
lowered the gain to +1 dB for now to stop this, but we need to revisit the ISS loop and
performance. Stefan can fix it up for us as penance when he returns from the hedonism of Amsterdam.
Entry  Thu Sep 18 18:38:14 2008, Yoichi, HowTo, Computers, How to compile an SNL code for VxWorks  
Dave Barker guided me through how to compile an SNL code into a Motorola 162 CPU object.

Here is the procedure:
Entry  Thu Sep 18 14:36:54 2008, josephb, Configuration, Computers, Name server and Epics 
The problems Rob was experiencing last night was due to part of the setup (or rather testing of the setup) of the new nameserver running on linux1.

The name server was setup on linux1 by doing the following:
Entry  Thu Sep 18 01:14:23 2008, rob, Summary, Computers, EPICS BAD 

Somehow the EPICS system got hosed tonight.  We're pretty much dead in the water till we can get it sorted.  
    Reply  Thu Sep 18 12:16:01 2008, Yoichi, Update, Computers, EPICS BACK 
[quote]
Somehow the EPICS system got hosed tonight.  We're pretty much dead in the water till we can get it sorted.  
[/quote]
       Reply  Thu Sep 18 13:05:05 2008, Yoichi, Update, Computers, EPICS BACK 
[quote]
The Y-arm doesn't, because one of the digital filters for the Y-arm lock fails to be loaded to the frontend.
I'm working on it now.[/quote]
Entry  Thu Sep 18 09:30:12 2008, steve, Update, General, low noise metal film resistors are in mfr&cap.pngstorcab.png
Low noise metal film resistor and capacitor kits from www.garrettelec.com are in.

manufacturer: Dale, 289 values, 25ea, surface mount,1206, 0.1% from 100 to 100K, 1/8 or 1/4W
Entry  Wed Sep 17 19:13:47 2008, Alberto, Update, General, ABSL: status 
I installed the setup for measuring TEM01/10 on the X end table. 
I'm leaving. I shut the laser, flipped down the flipper mirror, disconnected the pzt drive signal from the laser.
[B]For Jenne. The power cable for the Guralps' board is now connected to the PDH box on my instruments cart but you can take it.[/B]
Entry  Wed Sep 17 13:43:54 2008, Yoichi, Configuration, PSL, RC sweep going on 
I'm doing a cavity sweep of the RC. Please leave the IFO untouched until the meeting is over.
    Reply  Wed Sep 17 15:22:31 2008, Yoichi, Configuration, PSL, RC sweep going on 
[quote]I'm doing a cavity sweep of the RC. Please leave the IFO untouched until the meeting is over.[/quote]

The measurement is still going on.
       Reply  Wed Sep 17 17:58:35 2008, Yoichi, Configuration, PSL, RC sweep going on 
The cavity sweep is done. The IFO is free now.
Entry  Wed Sep 17 17:31:24 2008, Yoichi, Update, PSL, FSS calibration PZTresp.pngCalibration.pngFreqNoiseSpectrum.png
I calibrated the reference cavity error signal with the following procedure.

(1) I disconnected the PC path BNC cable and locked the RC only using the PZT. To do so, I had to insert a 20dB attenuator
Entry  Wed Sep 17 13:58:36 2008, Alberto, Update, General, ABSL: results from the X arm Sept17_XarmFSRmeasurement_report.ps
Today I repeated the measurement of the FSR on the X arm cavity. The noise in the transmitted power that made the measures fluctuate was much reduced after
last night Rob worked on the interferometer. The X arm cavity length is now: (38.4580+/-0.0003)m. I'm attaching a summary of the data I've taken.
Entry  Wed Sep 17 12:58:12 2008, rob, Update, Locking, bad 

Locking was pretty unsuccessful last night.  All the subparts were locked (ARMs, PRM, DRM) and 
aligned, but no DRMI+2ARMs locks.  The alignment may have drifted significantly by the time I 
Entry  Wed Sep 17 12:55:28 2008, rob, Configuration, IOO, MC length 
I measured the mode cleaner length last night:

[code]
Entry  Tue Sep 16 16:47:01 2008, pete, Configuration, PSL, Prototype FSS reference installed 
After verifying output, I installed the new prototype 21.5 MHz FSS reference (Wenzel crystal oscillator and ZHL-2 amp).  Yoichi and I successfully locked
the MC, and have left the new reference in place.  It's temporarily sitting on the corner of the big black optics table (AP table?).
Entry  Tue Sep 16 13:04:22 2008, Yoichi, Configuration, PEM, C1:PSL-FSS_RMTEMP alarm level changed 
At the request of Steve, I modified the HIGH value of C1:PSL-FSS_RMTEMP from 21.27 to 23.0.
The HIHI is set to 23.50.
Entry  Tue Sep 16 10:57:45 2008, Yoichi, Configuration, PEM, Particle counter gain 
Summary:
Since we reduced the integration time of the particle counter by a factor of 10, we had to add a gain of 10
to the EPICS channels C1:PEM-count_full and C1:PEM-count_half.
Entry  Mon Sep 15 14:00:52 2008, josephb, Configuration, Computers, 1Y9 Hub and C1asc 
The 1Y9 switch is now using a labeled Cat6 cable in cable trays to connect to the main switch in the offices.  In addition, the c1asc cable which had been
coming out the door was fixed last Friday, and is now labeled, going out the top and connects to the hub in 1Y2.
Entry  Sun Sep 14 18:30:32 2008, Alberto, Update, General, ABSL: measured X arm 
Today I measured the X arm FSR.
Hi moved the fast PD (Thor Labs PDA255) from the Y end table to the X end table. I had to use a beam splitter to pick out the transmitted beam from the
cavity beam and send it to the PD. I did not want to interpose the BS before the TRANS X PD, so I had to move the ETMXT camera to an other place in the
    Reply  Sun Sep 14 19:29:07 2008, Alberto, Update, General, ABSL: measured X arm 
[quote]Today I measured the X arm FSR.
Hi moved the fast PD (Thor Labs PDA255) from the Y end table to the X end table. I had to use a beam splitter to pick out the transmitted beam from the
cavity beam and send it to the PD. I did not want to interpose the BS before the TRANS X PD, so I had to move the ETMXT camera to an other place in the
Entry  Sat Sep 13 23:13:01 2008, Alberto, Update, General, abs cavity length experiment 
The Y arm was locked all time today but, suddenly, this afternoon it lost lock and since then I've been unable to restore it. I tried unsuccessfully the
Restore and the Align scripts several times, although the position of PZT steering mirrors were good (as in the snapshot). I tried things like unlocking/locking
the MC, the FSS reference cavity, the PMC but it didn't work. Then I decided to switch to the X arm. Locking it was a piece of cake compare to Y. I'm going
Entry  Fri Sep 12 11:09:20 2008, Alberto, Update, General, abs cavity length experiment 
I'm leaving the lab for a couple of hours. I shut the NPRO. The interferometer is available to anyone.
Entry  Thu Sep 11 23:28:35 2008, alberto, Update, General, abs cavity length experiment 
The MC lost lock for some reason not related to either the FSS or the PMC I'm done with my measurement for tonight. I've shut the NPRO beam before leaving.
Entry  Thu Sep 11 14:27:53 2008, steve, Bureaucracy, SAFETY, safety training 
Peter Kalmus received 40m specific safety training last week.
Entry  Thu Sep 11 11:29:14 2008, josephb, Configuration, Computers, Final netgear switch in place in 1Y2 
I've placed the final (of 4) Netgear prosafe 24 port switch at the very top of 1Y2.  At that location, there are no holes left to screw into, so it has
4 rubber feet and is sitting on the top most signal generator.  It has been plugged in and connected to the control room hub with a labeled cat6 ethernet
cable.
Entry  Wed Sep 10 19:53:53 2008, Alberto, Update, General, abs length experiment 
Update of the last days work on the experiment to measure the absolute length of the cavities.

I'm trying to repeat the same measurement that Koji did on the Y arm, before switching to the X arm.
Entry  Wed Sep 10 13:28:25 2008, Yoichi, Summary, Electronics, IOO rack lost -24V (recovered) 
Alberto, Yoichi

This morning, the MC suddenly started to be unwilling to lock.
Entry  Wed Sep 10 08:57:03 2008, steve, Update, General, etmy illuminator turned off 
The ETMY illuminator was left on yesterday.
I just turned it off.
Entry  Mon Sep 8 15:38:57 2008, Yoichi, Configuration, PSL, POY RF amp is back to its original task 
I temporarily fixed the busted ZHL-32A RF amplifier's power connector by simply soldering a cable to the internal circuit and pulling the cable out of the
box through a hole for the power connector.
So I released the POY RF amplifier from the temporary duty of serving the FSS RF distribution and put it back to the original task, 
Entry  Fri Sep 5 10:36:34 2008, steve, Update, PEM, thermostate setting changed 
Some one changed the thermostat (old control room ) setting behind 1Y6 from 73 to 79F
It should be in the elog.
The temp changed from freezing 20 to sunny 25 C 
    Reply  Fri Sep 5 15:09:50 2008, rana, Update, PEM, thermostate setting changed 
[quote]Some one changed the thermostat (old control room ) setting behind 1Y6 from 73 to 79F
It should be in the elog.[/quote]
In fact, it is.[FONT=Comic Sans MS] I demand satisfaction for the injury to my elogging reputation![/FONT]
       Reply  Mon Sep 8 13:47:35 2008, steve, Update, PEM, thermostate setting changed 
[quote][quote]Some one changed the thermostat (old control room ) setting behind 1Y6 from 73 to 79F
It should be in the elog.[/quote]
In fact, it is.[FONT=Comic Sans MS] I demand satisfaction for the injury to my elogging reputation![/FONT][/quote]
Entry  Mon Sep 8 10:57:49 2008, steve, Update, IOO, the psl and mc are back to normal fss.pngpmcbrick.pngbrick.jpg
The alarm handler is silent this morning.
This is almost unbelievably pleasant after two mount of harassment.
The MC did not lose lock for three days.
Entry  Fri Sep 5 09:56:14 2008, josephb, Eric, Configuration, Computers, Funny channels, reboots, and ethernet connections 
1) Apparently the I00-ICS type channels had gotten into a funny state last night, where they were showing just noise, exactly when Rana changed the accelerometer
gains and did major reboots.  A power cycle of the c1ioo crate and appropriate restarts fixed this.
Entry  Fri Sep 5 08:34:03 2008, steve, Update, PSL, MZ locked mzhv.jpg
The MC is happy.
The MZ can be locked if you move the slider by hand.
Entry  Thu Sep 4 18:02:34 2008, rana, josephb, Configuration, PEM, Accelerometer gains increased by 10 acc.png
[COLOR=chocolate][SIZE=3]We increased the Accelerometer gains by 10 by modifying the C1ADCU_PEM.ini file.[/SIZE][/COLOR]
[CODE]
[C1:PEM-ACC_MC1_X]
Entry  Thu Sep 4 17:44:27 2008, Yoichi, Update, PSL, FSS error signal spectrum FSS-Error-Spe.png
Attached is a spectrum of the FSS error signal.
There are a lot of sharp peaks above 100kHz (the UGF of the servo is about 200kHz).
These are mostly harmonics of 77kHz. They are the current suspects of the FSS slew rate saturation.
Entry  Thu Sep 4 17:17:03 2008, Yoichi, Update, IOO, MC open loop TF MC-OPLTF.png
I measured open loop transfer functions of the MC servo.
The UGF was about 30kHz. Since there was some gain margin at higher frequencies, I increased
the input gain of the MC servo board from 19dB to 22dB. Now the UGF is 40kHz and we have more 
Entry  Thu Sep 4 17:12:57 2008, Yoichi, Update, PSL, FSS open loop TF FSS-OPLTFs.png
I changed the gain settings of the FSS servo.
Now the Common Gain is 5dB (the last night it was 2dB) and the Fast Gain is 12dB (formerly 16dB).
I measured the open loop TF with this setting (the attachment).
Entry  Thu Sep 4 17:03:25 2008, Yoichi, Update, PSL, RF oscillator noise comparison RFSpectra.png
I measured current spectra of the RF signal going to the FSS EOM.
The attachment compares the spectra between a Stanford signal generator and a Marconi.
I borrowed the Marconi from the abs. length measurement experiment temporarily. 