Entry  Tue Feb 8 15:22:13 2011, kiwamu, Update, Green Locking, new electronics rack at X end DSC_2861_ss.png
 Yesterday I moved the whole green electronics stuff, which had been sitting on the floor at the X end, 
into a new electronics rack.
The rack now is placed under the cable rail close to the ETMX chamber.
    Reply  Thu Feb 10 00:23:25 2011, Jenne, Update, Green Locking, Green TRX DC PD installed on PSL 
Using a stray beam that is generated as the transmitted green beam from the Xarm goes through the viewport to the PSL table, I installed a fast lens
(because I was constrained for space) and a Thorlabs PDA36 photodiode on the PSL table.
The BNC cable runs along the edge of the PSL table, up the corner hole with the huge bundle of cables, and over to IOO_ADC_0.  It's channel 3 on
Entry  Thu Feb 10 05:06:35 2011, kiwamu, Update, Green Locking, beat noise : a little bit better, and 1Hz peak from amplitude noise coupling Screen_shot_2011-02-10_at_4.01.43.pngScreen_shot_2011-02-10_at_4.52.13.png
 I repeated the same measurement as that Koji did before (see here) with the
mixer-based frequency discriminator.
Entry  Sun Feb 13 15:02:23 2011, kiwamu, Update, Green Locking, X arm beam offcentering has been measured misposition.png
The amounts of the X arm's beam off-centering have been measured by the
A2L technique.
So now we are able to start aligning the IR beam axis in a quantitative
Entry  Fri Feb 18 15:05:49 2011, kiwamu, Update, Green Locking, transfer function of angle to beat note (length)  a2l_TF.png
[Koji and Kiwamu]
 We took transfer functions (TF) from the angle excitations at
ETMX and ITMX to the green beat note signal (i.e. angle to length TF).
Entry  Wed Feb 23 04:56:59 2011, kiwamu, Update, Green Locking, noise curve update noise_suprresion.png
New noise spectra of the green locking have been updated.
The plot below shows the in-loop noise
spectra when the beat signal was fedback to ETMX.
Entry  Thu Feb 24 17:42:00 2011, Aidan, Update, Green Locking, 15% of end laser sideband power transmitted through cavity 
I did a quick calculation to determine the amount of sideband transmission through the FP cavity.
The modulation frequency of the end PDH is 216kHz. The FSR of the cavity is about 3.9MHz. So the sidebands pick up about 0.17 radians extra phase
on one round trip in the cavity compared to the carrier.
Entry  Thu Feb 24 18:21:24 2011, kiwamu, Update, Green Locking, in-loop and out-of-loop measurements green_lock_setup.pngmeasurement1.pngTRX_REFL11.pngmeasurement2.png
Two different measurement have been performed for a test of the green locking last night.
Everything is getting better. yes. yes.
    Reply  Thu Feb 24 19:59:25 2011, kiwamu, Update, Green Locking, whitening filter for ALS ACDC.png
I forgot to mention about the whitening filter for the ALS digital control system.
As usual I used a whitening filter to have a good SNR against ADC noise, but this time our whitening scheme is little bit different from the
usual our systems.
Entry  Thu Feb 24 21:46:30 2011, kiwamu, Update, Green Locking, installed a summing box summing_box.pngtransfer_func.png
In this past weekend I replaced a summing amplifier for the end green PDH locking by a home-made summing circuit
box in order to increase the control range.
It's been working well so far.
    Reply  Sat Feb 26 02:33:16 2011, kiwamu, Update, Green Locking, sidebands on beatnote beat_note.png
 The power ratio of
the beatnote signal vs. the 216kHz sideband has been measured.
The measured ratio was -55 dB, which is smaller by about 20 dB than Aidan's
    Reply  Sun Feb 27 09:43:59 2011, Aidan, Update, Green Locking, sidebands on beatnote 
Can we set up a fiber-PD on the end table to look at the beat between the "end laser IR beam" and the "PSL IR beam fiber-transmitted end
beam"? 
We should see the same thing on that PD that we see on the green PD (plus any fiber noise and I'm not really sure how much that'll be off the top
    Reply  Sun Feb 27 13:09:56 2011, rana, Update, Green Locking, sidebands on beatnote 
When Koji and I were massaging the MC, we noticed that the oscillations were at 48.5 kHz. They were pretty huge and are probably what you're seeing on
the beat. My guess is that they are the PZT resonances of the PSL 2W NPRO; we need to put a notch in the FSS box - it still has the notch from the old
NPRO.
Entry  Wed Mar 2 16:51:53 2011, steve, Configuration, Green Locking, mech shutter in place at the south end 
I moved old POX shutter from ITMY optical table to the south end. MEDM POX mechanical shutter screen is now closing the green beam  injection into
the Y arm.
I kluged in a 40m long bnc cable that Alberto left on the floor for control. It is labelled POX-sht  This is a temporary set up.
Entry  Wed Mar 2 17:19:58 2011, Aidan, Configuration, Green Locking, Moved PDH PD on end table P1000223-a.jpgP1000218.jpgP1000224.jpg
As previously noted, there are multiple beams coming back from the ETM surface onto the PDH PD on the end table. They are spread out in a vertical pattern.
All the spots swing together (as the ETM moves?).
I moved the PDH Green PD on the end table so that it was further away from the Faraday and I added an iris in between the Faraday and the PD. Now
Entry  Wed Mar 2 18:08:43 2011, Aidan, Update, Green Locking, Ghost beams on green Ghost_Beam_at_ETM_DCBS.pdf
Kiwamu and I noticed that there is a ghost beam on the green beam going into the ETM. What we see is some interference fringes on the edge of the transmission
of the green beam through the dichroic beam splitter (DCBS). If we look at the reflection from the dichroic beam splitter these are much more pronounced.
The spacing of the fringes (about 2 per 10mm) indicates an angle between the fields of around 0.1 mrad.
Entry  Thu Mar 3 00:12:52 2011, kiwamu, Update, Green Locking, plan 
Tomorrow's tasks
  - Auto noise budget
(Jamie)
  - Demodulation phase adjustment (Kate)
 
- Auto alignment for green (Joe/Kiwamu)
  - ADC connection for the X end green REFL_DC
Entry  Thu Mar 3 07:25:24 2011, kiwamu, Update, Green Locking, screwed up the end PDH box 
 I somehow screwed up the PDH
box at the X end station. 
Right now it's not working,
Entry  Fri Mar 4 03:31:35 2011, kiwamu, Update, Green Locking, A first noise budget noise_budget.png
I made a noise budget for the ALS noise measurement that I did a week ago (see #4352).
I am going to post some details about this plot later because I am now
too sleepy.
    Reply  Fri Mar 4 18:06:34 2011, kiwamu, Update, Green Locking, noise budget : differential noise open_loop_TF.pngservos.png
Here I explain how I estimate the contribution from the differential noise shown in the plot on my last entry (#4376)
.
 
Entry  Mon Mar 7 18:20:01 2011, kiwamu, Summary, Green Locking, plans 

This week's goal is to investigate the source of the differential noise and to lower it.


 
Plans for tonight
 - realign GREEN_TRANS PD at the PSL table
 -
update the noise budget
 - take spectrum of the differential noise
 - investigate a noise coupling to the differential
Entry  Tue Mar 8 06:29:06 2011, kiwamu, Update, Green Locking, Intensity noise setup 
[Jenne, Chris, Kiwamu]
 A photo diode and an AOM driver have been newly setup on the PSL table to measure the intensity noise
coupling to the beat note signal.
Entry  Tue Mar 8 15:20:31 2011, kiwamu, Update, Green Locking, differential noise on Mar.8th differential_noise20110308.png

Noise below 10 Hz became larger again compared with the data before
    Reply  Tue Mar 8 15:33:09 2011, kiwamu, Summary, Green Locking, plan on Mar.8th 

 Today's goal is to measure the contribution from the intensity noise to the beatnote.
 
Plans for today

 
    Reply  Wed Mar 9 04:46:13 2011, kiwamu, Update, Green Locking, more intensity noise measurement intensity_setup.pngIntensityNoise.png
 
Here is a diagram for our intensity noise coupling measurement.
    Reply  Wed Mar 9 18:17:11 2011, kiwamu, Update, Green Locking, Intensity noise coupling diff_noise.pngIN_TF.png
Here is a new plot for the differential noise measurement. I plot a noise contribution from the intensity noise
(brown curve).
If we believe this data, the differential noise is NOT
    Reply  Thu Mar 10 14:06:54 2011, kiwamu, Update, Green Locking, Intensity noise limits the beatnote sensitivity diff_noise_Mar8.pngIN_TF_complete.png
We are limited by the intensity noise of the X arm transmitted green light.
Since the intensity noise from the PSL wasn't big enough to explain the differential noise (#4392),
so this time I measured the noise contribution from the X arm transmitted light.
    Reply  Thu Mar 10 14:22:58 2011, kiwamu, Update, Green Locking, Intensity noise limits the beatnote sensitivity 
The next steps we should do are :
    - to investigate a cause of the intensity fluctuation
          *
end green laser
          * suspensions' angular motions
         
    Reply  Thu Mar 10 14:29:05 2011, Koji, Update, Green Locking, Intensity noise limits the beatnote sensitivity 
We can modify the freq divider circuit to make it a comparator.


    
        
            Quote:
        
        
            
    Reply  Thu Mar 10 14:30:53 2011, rana, Update, Green Locking, Intensity noise limits the beatnote sensitivity 
There are 3 standard techniques to reduce this effect:
1) Stabilize the end laser by sensing the green light coming into the PSL before recombination and feeding back with SR560 (this is the only one
that you should try at first).
    Reply  Thu Mar 10 16:00:53 2011, Aidan, Joe, Update, Green Locking, Intensity stabilization loop using beatnote DC. P1000313.jpgP1000314.jpgP1000315.jpgGREEN_ISS_LOOP.pdfScreenshot-C1ALS_OVERVIEW.adl.png
Aidan: Joe and I have added a channel that takes the DC output from the vertex beatnote PD and sends it, via RFM, to a DAC at the ETMX end. Immediately
before the output is a filter C1GCX_AMP_CTRL. The output of the DAC is connected to the CURRENT LASER DIODE modulation input on the back of the Innolight
driver. This will modulate the current by 0.1A/V input.
    Reply  Thu Mar 10 21:45:34 2011, rana, Update, Green Locking, Intensity stabilization loop using beatnote DC. 
Ridiculous and hacky. Digital stabilization removed as well as the old "leave a pile of equipment
on a stool" strategy.
We used a a BNC cable to send a pickoff of the beam before the recombination to the end via an SR560.
Entry  Fri Mar 18 12:22:04 2011, kiwamu, Update, Green Locking, Y arm plan for today 
 Prior to the works on the Y end setup I propose to perform the temperature scan business like Koji and
Suresh did before (see this entry).
    Reply  Fri Mar 18 16:06:30 2011, kiwamu, Update, Green Locking, Re: Y arm plan for today 
We use Alberto's laser for the Y end Green Locking.  


    
        
            Quote:
        
        
            
    Reply  Fri Mar 18 16:31:11 2011, Suresh , Update, Green Locking, Re: Y arm plan for today 
The reason for using Alberto's laser is that some amount of work has already gone into characterising its phase noise. 
Ref elog entry
2788
Entry  Fri Mar 18 17:55:58 2011, Suresh, Configuration, Green Locking, Work Plan for Y-end Aux laser installation 
A rough time-table and the various tasks are given below: 
Note:  700mW NPRO sitting on AP table (Model No: 126-1064-700, Sl No. 415) 
= Alberto's laser 
Entry  Mon Mar 21 16:49:11 2011, kiwamu, Summary, Green Locking, plan for this week 
- Plan for this week
  * Intensity stabilization for the end green laser (Matt / Kiwamu)
  * Hand off the servo from Green to Red (Matt / Kiwamu)
Entry  Mon Mar 21 18:34:10 2011, kiwamu, Update, Green Locking, added a new ADC channel on 1X9 aa_board_1X9.jpg
I added a new ADC channel for a DC signal from the X end green PD.
It is called C1:GCX-REFL_DC and connected to adc_0_1, which is the second channel of ADC_0.
 
    Reply  Tue Mar 22 00:01:25 2011, kiwamu, Summary, Green Locking, plan for daytime tasks 
Some tasks for the daytime tomorrow.
  * Beam profile measurements of the Y end laser  (Suresh / Bryan)
  * Taking care of CDS and the simulated plant (Jamie / Joe) 
Entry  Tue Mar 22 00:03:29 2011, Bryan, Configuration, Green Locking, PSL vs Y arm laser temperature pairing PSL_vs_Y_arm_Temperatures.png
 OK. Today we did the same type of measurement for the Y arm laser as was done for the X arm laser here: http://nodus.ligo.caltech.edu:8080/40m/3759 
And attached here is a preliminary plot of the outcome - oddities with adding on the fitted equations, but they go as follows
    Reply  Tue Mar 22 00:23:20 2011, Jenne, Configuration, Green Locking, PSL vs Y arm laser temperature pairing 


    
        
            Quote:
        
        
            
             OK. Today we did the same type of measurement for the Y arm laser as was done for the X arm laser here: 
Entry  Tue Mar 22 16:39:51 2011, kiwamu, Update, Green Locking, comaprator installed : 80 pm residual displacement noise_curve20110322.png
 A comparator has been installed before the MFDs (mixer-based frequency discriminator) to eliminate
the effect from the amplitude fluctuation (i.e. intensity noise).

As a result we reached
    Reply  Tue Mar 22 19:03:45 2011, Bryan, Configuration, Green Locking, PSL vs Y arm laser temperature pairing 


    
        
            Quote:
        
        
            

            I'm going to take the easy question - What are the pink data points??
Entry  Wed Mar 23 00:51:47 2011, kiwamu, Update, Green Locking, plan for tomorrow 
  - Plan for tomorrow
    * Video cable session (I need ETMY_TRNAS) (team)
    * Characterization of the Y end laser  (Bryan / Suresh)
Entry  Wed Mar 23 05:11:08 2011, kiwamu, Update, Green Locking, servo handig off stripTransit_edit.pngnoise_curve20110322_hUGF.png
Succeeded in handing off the servo from the green to the red.
    Reply  Wed Mar 23 08:50:36 2011, Aidan, Update, Green Locking, servo handig off green-to-red.jpg
Nicely done!
 


    
        
            
Entry  Wed Mar 23 19:16:17 2011, Aidan, Summary, Green Locking, Y-END green equipment is all available three-quarter_inch_pedestal.jpg
With the exception of a 2" mirror mount, I've confirmed that we have everything for the Y-end green production and mode-matching.
We need to calculate a mode-matching solution for the Lightwave laser so that it gives the correct beam size in the doubling crystal.
Additionally, Rana has suggested that we change the pedestals from the normal 1"
    Reply  Thu Mar 24 01:16:19 2011, Suresh, Summary, Green Locking, Y-END green equipment is all available 
There was a 2" mirror mount among the spares on the PSL table.  It has a window LW-3-2050 UV mounted in it.  I
have moved it to the Y-end table.  We seem to have run out of 2" mirror mounts ...
Entry  Thu Mar 24 13:50:30 2011, Bryan, Configuration, Green Locking, Y arm laser IMG_0188.JPGIMG_0190.JPG
 Just a quick update... the Lightwave laser has now been moved up to the end of the Y arm. It's also been mounted on the new mounting block and
heatsinks attached with indium as the heat transfer medium.
A couple of nice piccies...
    Reply  Thu Mar 24 15:30:59 2011, Bryan, Configuration, Green Locking, PSL vs Y arm laser temperature pairing Temp_Beating_Day02_html_m2d719182.jpg
Fine-grained
temperature vs temperature data around the current operating point of the PSL laser.
 
 
The last set of data was taken in 1 degreeC steps,