40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 155 of 341  Not logged in ELOG logo
ID Date Author Type Categorydown Subject Text Attachments
  1408   Tue Mar 17 08:44:37 2009 YoichiConfigurationIOOMC1 driftI'm done with the MC1 drift measurement.
The result is attached. It is clear that
MC1 is in trouble. The small drifts in the
 MC1_Drift3.pdf 
  1409   Thu Mar 19 02:45:36 2009 YoichiConfigurationIOOA loose wire found for MC1 I found a loose connection of a wire in the
cross-connect between an ADC and the MC1
coil driver's UL bias input.
  
  1410   Thu Mar 19 10:45:43 2009 YoichiConfigurationIOOA loose wire found for MC1 I attached a 6-hour trend of the MC mirror
OSEM signals with the MC unlocked.
The drift of the MC1 is within 20 counts
 AfterWireFix-1.pdf 
  1425   Wed Mar 25 01:37:35 2009 rana, yoichiSummaryIOONo Reference Cavity RequiredWe were wondering if we need to have a reference
cavity. One possible reason to have one is
to reduce the free running
  
  1427   Wed Mar 25 09:55:45 2009 steveUpdateIOOglitching sensors of MCSUS-MC1_SENSOR_SIDE and SUS-MC2_SENSOR_UL
are glitching
Yesterday's 4.8mag earthquake at
 glitchesofMC.jpg 
  1428   Wed Mar 25 17:22:58 2009 YoichiUpdateIOOMC lock without FSSI made 40k:4k passive filter in a POMONA box
and connected it to IN1 (not TEST IN1) of
the FSS box.
 MC-loop-gain.png 
  1429   Wed Mar 25 20:41:43 2009 JenneUpdateIOOMode Cleaner Servo Board Transfer Functions (to be updated)When all things fail (netgpibdata.py is
giving me weird data.  When I plot the
data it has saved from the 4395A, it's some
 MCwithBoxsmall.JPGMCnoBoxsmall.JPGPomonaBoxforMCsmall.JPG 
  1430   Thu Mar 26 00:45:24 2009 JenneUpdateIOOMode Cleaner Servo Board Transfer Functions (to be updated)


   
        
            
 MCwithandwithoutfilter25Mar2009.pngPomonaBoxMCfilter25Mar2009.pngMCServoData25Mar2009.tar.gz 
  1432   Thu Mar 26 04:09:38 2009 YoichiUpdateIOOSingle X arm lock spectra with different MC lock schemesThe attached plots show MC_F, FSS_FAST_F and
XARM IN/OUT spectra with different MC locking
modes.
 XarmSpectra.pdfXarmSpectraZoom.pdf 
  1435   Fri Mar 27 02:40:06 2009 peteSummaryIOOMC glitch investigationYoichi, Pete
The MC loses lock due to glitches
in the MC1 coils. 
We do
 MC1_Drift.png 
  1437   Fri Mar 27 15:05:42 2009 YoichiUpdateIOOMC glitch investigationAttached plots are the result of the
MC1 trend measurement.
See the
attachment #1. The first two plots show the
 MC1_Drift.pdfMC2_Drift.pdf 
  1438   Fri Mar 27 17:52:16 2009 YoichiUpdateIOOMC glitch investigationPer Rob's suggestion, I put the probes
across the output resistors of the bias current
buffers instead of measuring the output voltage
  
  1443   Mon Mar 30 12:46:36 2009 YoichiConfigurationIOOIOO QPDs were missing the beamWhen I re-locked the MC, I wanted to check
the trend of the IOO QPDs to see if the input
beam pointing has changed.
 IOO-QPDs.pdf 
  1451   Wed Apr 1 23:18:07 2009 rana, kojiSummaryIOONo Reference Cavity RequiredKoji sent us a note about our "No Reference
Cavity Required" entry. I thought that it
nicely summarizes the
  
  1503   Mon Apr 20 20:00:44 2009 ranaConfigurationIOOMcWFS gains re-allocatedSince it looks like the night time people
have been running with a WFS gain of 0.05
and I like the slider
  
  1607   Tue May 19 15:57:07 2009 steveUpdateIOOMC2 damping restored after EQ  Earthquake mag 4.0 at Lennox, Ca
    trips MC2 watchdogs
      http://quake.usgs.gov/recenteqs/Quakes/ci10411545.html
 acc.jpg 
  1768   Tue Jul 21 15:32:47 2009 JenneUpdateIOOMC_L flatlined[Clara, Jenne]
While Clara was working on her Wiener
filtering and optimizing the locations of
  
  1770   Tue Jul 21 17:52:12 2009 JenneUpdateIOOMC_L flatlined


   
        
            
  
  1795   Mon Jul 27 09:34:07 2009 steveSummaryIOOAligning the mode cleaner


   
        
            
 20dtrend.jpg 
  1799   Mon Jul 27 19:55:19 2009 KojiHowToIOOLens selection: plano-convex? or bi-convex?Q. When should we use plano-convex lenses,
and when should we use bi-convex?
As I had the same question from Jenne
  
  1812   Thu Jul 30 03:10:18 2009 robUpdateIOOMC tweaked furtherI tilted the periscope beam and aligned
the MC.  Now the spot at the Faraday
entrance is near the center of the aperture
  
  1814   Thu Jul 30 21:26:16 2009 ranaUpdateIOOMC Drumhead modeI used COMSOL 3.5a to do a FEA of one of the
MC flat mirrors. Should be close to the same
for all the mirrors.
 mc2drum.png 
  1820   Mon Aug 3 14:15:50 2009 JenneUpdateIOOWFS recenteredI am (was) able to get the mode cleaner
mostly locked, but because WFS2 wasn't centered,
the MC would drift, then lose lock. 
  
  1821   Mon Aug 3 14:47:53 2009 JenneUpdateIOOMC locks againThe mode cleaner seems to be locking again. 
I've manually unlocked it a few times in
the past 20min, and most of the time it catches
  
  1823   Mon Aug 3 22:54:53 2009 Jenne, Koji, ranaUpdateIOOMC_trans is now better, but not bestJenne, Koji,
Rana
 P8030099_copy.JPGP8030102_copy.JPG 
  1825   Tue Aug 4 11:54:20 2009 JenneUpdateIOOMC_trans readout on LOCK_MC screen now normalizedThe MC_trans QPD Pitch and Yaw readout
on the Lock_MC screen are now normalized
by the trans_sum. I used the method described
  
  1895   Thu Aug 13 00:11:43 2009 JenneUpdateIOOMode Cleaner UnlockSo that I can collect a bit of free-swinging
Mode Cleaner data, I started a script to
wait 14400 seconds (4 hours), then unlock
  
  1896   Thu Aug 13 02:17:56 2009 JenneUpdateIOOMode Cleaner AlignmentWhen Rob and I were getting started on
locking for the evening, Mode Cleaner lost
lock a few times, but every time it lost
  
  1924   Tue Aug 18 15:16:15 2009 robUpdateIOOMC WFS working againRob, Yoichi
 
The MC WFS have apparently been bad
  
  1928   Wed Aug 19 17:11:33 2009 JenneUpdateIOOQPDs aligned


   
        
            
  
  1997   Thu Sep 24 15:45:27 2009 robUpdateIOOMC OLGI measured the mode cleaner open loop gain
with the HP3563A. 
  
  2043   Fri Oct 2 15:24:29 2009 sanjit, ranaSummaryIOOmcwfs centeredwe set the offsets for the MCWFS DC and
for the MCWFS demod outputs and then turned
off the lights put the MZ at half fringe
 Untitled.png 
  2062   Wed Oct 7 06:26:09 2009 ranaHowToIOOMC_L calibration + some DTT loreI drove MC2 in POS and used the
resulting response in MC_F to calibrate the
IOO-MC_L channel.
 mcl-cal.pnga.png 
  2076   Fri Oct 9 16:36:13 2009 rob UpdateIOOfrequency noise problemI used the XARM as a reference to measure
the frequency noise after the MC.  It's
huge around 4kHz--hundreds of times larger
 freqnoiseaftermc.png 
  2077   Fri Oct 9 17:37:21 2009 JenneUpdateIOOMC2 trans beam is dumpedLast night while noise hunting, Rana found
that the MC2 trans beam has been left for
an unknown length of time just hitting the
  
  2102   Fri Oct 16 10:15:02 2009 steveUpdateIOOIP ang & pos recenteredPointing stability of 4 days. Initial pointing
does not go through suspended optics. It
is launched  right after the Piezo Jena
 ip4d.jpg 
  2123   Tue Oct 20 02:14:29 2009 robUpdateIOOMC2 alignment bias changedthe mode cleaner was having trouble locking
in a 00 mode, needing several tries. 
I changed the MC2 coil biases, and it seems
  
  2124   Tue Oct 20 10:46:18 2009 steveUpdateIOOclipping IP-ANG beam at ETMX chamberInitial pointing beam is clearly clipping
on 2" pick off mirror in  ETMX
vacuum chamber.
 PA200175.JPGPA200177.JPG 
  2132   Thu Oct 22 08:45:58 2009 steveUpdateIOOIP ang & pos recentered

    
        
 pointing1000.jpg 
  2144   Mon Oct 26 18:15:57 2009 robUpdateIOOMC OLGI measured the mode cleaner open loop gain. 
It's around 60kHz with 29 degs of phase margin.
  
  2168   Mon Nov 2 13:00:55 2009 KojiUpdateIOOPMC aligned, MC WFS alignedThe beam to PMC aligned. The beam to MC
WFS cameras aligned.
PMC Trans increased from 2.73 to 2.75
  
  2172   Tue Nov 3 03:45:04 2009 rob UpdateIOOfrequency noise problem

    
        
 noise.pngspectra.pdf 
  2227   Tue Nov 10 17:01:33 2009 AlbertoConfigurationIOOc1ioovme and c1iool0 rebooted This afternoon, while I was trying to add
the StochMon channels to the frames, I rebooted
the c1ioovme and c1iool0.
  
  2234   Wed Nov 11 09:48:04 2009 steveUpdateIOOwhere is IOO-RFAMPD_DCMON ?RFAMPD_DCMON disappered on Nov 5, 2009  rfampddc.jpg 
  2318   Mon Nov 23 21:36:38 2009 KojiUpdateIOOAligned PMC/RCI aligned the beam goes to PMC. It increased
the MC Trans from 8.25 to 8.30.
I also aligned the beam goes to RC.
 091123_PSL.png 
  2357   Sat Dec 5 17:34:30 2009 robUpdateIOOfrequency noise problemThere's a large broadband increase in the
MC_F spectrum.  I'm not totally sure
it's real--it could be some weird bit-swapping
 mcf.png 
  2359   Sat Dec 5 22:31:52 2009 robUpdateIOOfrequency noise problem

    
        
  
  2406   Sun Dec 13 20:50:45 2009 ranaSummaryIOOMach Zender CalibrationI ramped the MZ PZT (with the loop disabled
on the input switch) to calibrate it. Since
the transmission has been blocked, I used
 Untitled.png 
  2407   Sun Dec 13 23:18:09 2009 ranaSummaryIOODisplacement noise on the PSL tableFor the Laser Gyro, I wondered how much
mechanical noise we might get with a non-suspended
cavity. My guess is that the PMC is better
 mz.pdf 
  2431   Fri Dec 18 15:40:33 2009 KojiUpdateIOOMC2 spot centered / MCT QPD issueThis afternoon I felt like saying hello
to the input mode cleaner. So I decided to
center the spot on MC2.
  
ELOG V3.1.3-