40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
40m Log, Page 153 of 172
Not logged in
List
|
Find
|
Login
|
Help
Full
|
Summary
| Threaded |
Collapse
|
Expand
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- Type --
Configuration
Update
Summary
HowTo
Bureaucracy
Omnistructure
Metaphysics
Frogs
8554 Entries
Goto page
Previous
1
,
2
,
3
...
152
, 153,
154
...
170
,
171
,
172
Next
Fri Nov 14 19:20:42 2008, Yoichi, Update, PSL, Reference cavity ring down
Fri Nov 14 20:35:47 2008, rana, Update, PSL, Reference cavity ring down
Fri Nov 14 22:40:51 2008, Yoichi, Update, PSL, Reference cavity ring down
Mon Nov 17 15:07:06 2008, Yoichi, Update, PSL, Reference cavity ring down
Mon Nov 17 11:01:15 2008, Alberto, HowTo, Electronics, Calibrating the Frequency Standard of the Marconi
Fri Nov 14 17:41:50 2008, Jenne, Omnistructure, Electronics, Sweet New Soldering Iron
Fri Nov 14 11:33:19 2008, steve, Update, VAC, SRS-RGA installed
Thu Nov 13 15:50:44 2008, Alberto, Configuration, General, GPS 10MHz clock
Thu Nov 13 11:33:25 2008, Alberto, HowTo, Treasure, Making (good) Matlab figures
Wed Nov 12 11:36:13 2008, Jenne, Update, PEM, Guralp Breakout Box is ~50% hooked up
Wed Nov 12 11:14:59 2008, Caryn, DAQ, PSL, MC temp sensor hooked up incorrectly
Mon Nov 10 16:44:14 2008, steve, Update, PEM, particle counter at MC2
Mon Nov 10 11:32:49 2008, rob, Update, Computers, c1iscex rebooted
Mon Nov 10 11:06:09 2008, rob, HowTo, IOO, mode cleaner locked
Fri Nov 7 18:38:19 2008, Alberto, DAQ, PSL, MC temperature sensor hooked up
Fri Nov 7 16:05:55 2008, steve, Bureaucracy, SAFETY, insect killer sprayed at kitchen area !
Fri Nov 7 08:08:00 2008, steve, Update, PEM, AC turned off in IFO room
Thu Nov 6 10:06:41 2008, steve, Update, Locking, arms lock degradation
Thu Nov 6 09:45:27 2008, steve, Update, MOPA, head temp hick-up vs power
Wed Nov 5 12:41:36 2008, Alberto, Update, LSC, Absolute Length and g-factor measurements conclusions
Tue Nov 4 01:03:01 2008, rana, Summary, PEM, periodic thump noise in MC1_ACC
Sun Nov 2 20:44:58 2008, rana, Update, ASS, Wiener Filter performance over 5 hours
Mon Nov 3 22:35:40 2008, rana, Update, ASS, Wiener Filter performance over 5 hours
Tue Nov 4 00:47:53 2008, rana, Update, ASS, Wiener Filter performance over 5 hours
Mon Nov 3 19:18:47 2008, Alberto, Configuration, General, new elog
Mon Nov 3 21:38:32 2008, Yoichi, Configuration, General, new elog
Mon Nov 3 19:12:27 2008, alberto, Update, General, Transverse mode spacing measurement for the X arm
Mon Nov 3 09:59:47 2008, steve, Update, PSL, PSL HEPAs turned on
Sun Nov 2 21:37:22 2008, rana, Update, PEM, Ranger recovery
Fri Oct 31 08:52:19 2008, steve, Update, SUS, ETMY damping restored
Thu Oct 30 20:39:47 2008, caryn, Configuration, PEM, temperature sensor
Thu Oct 30 11:07:25 2008, Yoichi, Update, Computers, Wireless bridges arrived
Wed Oct 29 12:54:28 2008, Jenne, Update, PEM, Calibrated Guralp Noise compared to average ground motion
Wed Oct 29 12:23:04 2008, Yoichi, Configuration, PSL, MZ alignment touched and the alarm level changed
Fri Oct 24 20:54:41 2008, rana, Configuration, Computers, linux2
Tue Oct 28 12:01:01 2008, josephb, Configuration, Computers, linux2
Tue Aug 12 21:38:19 2008, John, Update, LSC, Accidental higher order mode resonances in the arms
Tue Oct 28 11:10:18 2008, Alberto, Update, LSC, Higher Order Mode resonances in the X arms
Mon Oct 27 14:48:27 2008, Yoichi, Configuration, PSL, EO shutter installed to the reference cavity
Mon Oct 27 11:23:10 2008, steve, Update, Photos, new Olympus camera with IR vision
Mon Oct 27 11:16:23 2008, Alberto, Configuration, IOO, StochMon Calibration
Sun Oct 26 21:02:18 2008, rana, Update, Computer Scripts / Programs, SVN medm problem
Mon Oct 27 10:02:16 2008, Yoichi, Update, Computer Scripts / Programs, SVN medm problem
Fri Oct 24 22:30:38 2008, Jenne,rana, Update, PEM, Noise from Guralp Seismometer
Fri Oct 24 21:49:15 2008, Jenne, Configuration, PEM, Short Seismometer Cable
Fri Oct 24 18:05:01 2008, Alberto, Update, General, Abs length: transverse mode spacing measured for the X arm
Fri Oct 24 17:21:13 2008, Alberto, Update, General, Abs length: the right amount of beam clipping
Fri Oct 24 15:05:13 2008, steve, Update, VAC, rga is out of order
Fri Oct 24 11:42:48 2008, Alberto, Update, General, Abs length: locking the X arm cavity in TEM01/10
Fri Oct 24 11:21:26 2008, pete, Configuration, PSL, FSS LO input calibrated in dBm
Fri Oct 24 11:09:08 2008, steve, Update, SAFETY, more lexan plates under cameras
Fri Oct 24 10:06:16 2008, Yoichi, Configuration, IOO, MC gain and FSS gain changed
Thu Oct 23 23:09:18 2008, Yoichi, Update, PSL, MC UGF is now 75kHz
Thu Oct 23 21:52:27 2008, Yoichi, Update, PSL, FSS UGF now 450kHz
Thu Oct 23 20:47:28 2008, pete, Configuration, PSL, FSS LO calibration for MEDM
Thu Oct 23 18:51:19 2008, Alberto, Metaphysics, Computers, eLog
Thu Oct 23 18:45:18 2008, Alberto, Omnistructure, Computer Scripts / Programs, Python code for GPIB devices developed for the Absl length experiment
Thu Oct 23 15:27:19 2008, Alberto, Update, General, Abs length
Thu Oct 23 18:23:47 2008, Alberto, Update, General, Abs length
Thu Oct 23 18:27:04 2008, Alberto, Update, General, Abs length
Thu Oct 23 11:26:25 2008, steve, Bureaucracy, VAC, optosigma forks for vacuum
Goto page
Previous
1
,
2
,
3
...
152
, 153,
154
...
170
,
171
,
172
Next
ELOG V3.1.3-