40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 152 of 344  Not logged in ELOG logo
Entry  Thu Nov 17 09:06:35 2022, JC, Summary, General, Light Replace 
Entry  Mon Nov 21 14:55:58 2022, JC, Configuration, General, LED Instead of Incandescent Lights  
Entry  Fri Feb 12 18:58:46 2010, kiwamu, Update, Green Locking, take some optics away from the ETM end table DSC_1164.JPGDSC_1172.JPG
    Reply  Tue Feb 16 09:51:22 2010, Alberto, Update, Green Locking, take some optics away from the ETM end table 
    Reply  Tue Feb 16 11:12:51 2010, kiwamu, Update, Green Locking, Re:take some optics away from the ETM end table 
    Reply  Tue Feb 16 16:24:30 2010, kiwamu, Update, Green Locking, Re:Re:take some optics away from the ETM end table 
Entry  Fri Feb 19 16:40:43 2010, kiwamu, Update, Green Locking, rearrange the optics on the end table DSC_1202.JPGDSC_1207.JPG
    Reply  Wed Mar 24 03:58:18 2010, kiwamu, matt, koji, Update, Green Locking, leave PLL locked DSC_1402.JPG
    Reply  Wed Mar 24 04:22:51 2010, kiwamu, matt, Update, Green Locking, two NPRO PLL  
Entry  Wed Mar 24 12:38:17 2010, Hartmut, Configuration, Green Locking, Broadband PD for green PLL SiAmpl.pngSiPhase.png
    Reply  Wed Mar 24 14:52:02 2010, Alberto, Update, Green Locking, two NPRO PLL  
    Reply  Wed Mar 24 15:59:59 2010, kiwamu, matt, Update, Green Locking, leave PLL locked 
    Reply  Thu Mar 25 17:29:48 2010, kiwamu, mott, Update, Green Locking, PLL two NPROs 
Entry  Sun Mar 28 17:28:26 2010, matt, kiwamu, Update, Green Locking, frequency discriminator for green PLL 6x
    Reply  Mon Mar 29 15:19:33 2010, mevans, Update, Green Locking, frequency discriminator for green PLL 
Entry  Tue Mar 30 21:11:42 2010, kiwamu, Summary, Green Locking, conversion efficiency of PPKTP efficiency_waist_edit.png
    Reply  Tue Mar 30 22:13:49 2010, Koji, Summary, Green Locking, conversion efficiency of PPKTP 
    Reply  Wed Mar 31 02:57:48 2010, kiwamu, Update, Green Locking, frequency counter for green PLL FCnoise.png
    Reply  Wed Mar 31 11:52:32 2010, kiwamu, Summary, Green Locking, Re:conversion efficiency of PPKTP 
    Reply  Wed Mar 31 12:30:31 2010, rana, Update, Green Locking, frequency counter for green PLL 
    Reply  Thu Apr 1 15:21:12 2010, rana, Update, Green Locking, frequency counter for green PLL 
Entry  Thu Apr 1 16:34:29 2010, Hartmut, Update, Green Locking, Silicon PDs 
Entry  Thu Apr 1 20:29:02 2010, Hartmut, Update, Green Locking, simple PD test circuit pdtest.png
    Reply  Mon Apr 12 14:20:10 2010, kiwamu, Update, Green Locking, PZT response for the innolight 
Entry  Mon Apr 12 19:50:30 2010, Aidan, Summary, Green Locking, Temperature sweep of the Lightwave: df/dT = 2.8GHz/K LightWave_temp_sweep.pdfLightWave_Temp.m
    Reply  Mon Apr 12 20:48:51 2010, Aidan, Mott, Summary, Green Locking, Temperature sweep of the Innolight: df/dT ~ 3.3GHz/K Innolight_temp_sweep.pdfInnolight_Temp.m
    Reply  Tue Apr 13 12:39:51 2010, Aidan, Mott, Summary, Green Locking, Temperature sweep of the Innolight: df/dT ~ 3.3GHz/K 
    Reply  Tue Apr 13 19:53:06 2010, Mott, Update, Green Locking, PZT response for the innolight and lightwave 6x
Entry  Sat Apr 17 18:30:12 2010, Zach, Update, Green Locking, 1W NPRO output profile profile_fit_4_17_10.png
    Reply  Mon Apr 19 11:31:04 2010, Aidan, Update, Green Locking, 1W NPRO output profile 
Entry  Mon Apr 19 16:27:13 2010, Aidan, Update, Green Locking, Raicol crystals arrived and we investigated them 
    Reply  Tue Apr 20 11:14:31 2010, Aidan, Update, Green Locking, Raicol crystals arrived and we investigated them 
Entry  Tue Apr 20 13:02:14 2010, Zach, Update, Green Locking, 1W NPRO output profile profile_fit_4_19_10.png
    Reply  Tue Apr 20 13:37:36 2010, Jenne, Update, Green Locking, 1W NPRO output profile 
    Reply  Tue Apr 20 19:37:02 2010, Koji, Update, Green Locking, 1W NPRO output profile 
Entry  Wed Apr 21 10:09:23 2010, kiwamu, Update, Green Locking, waist positon of Gaussian beam in PPKTP crystals focal_positin_edit.png
Entry  Fri Apr 23 18:30:49 2010, Aidan, Jenne, Koji, Summary, Green Locking, Green means GO! IMG_2405.jpgIMG_2417.jpg
Entry  Mon Apr 26 11:14:04 2010, Koji, Update, Green Locking, Temperature scan for PPKTP SHG_pow.png
    Reply  Tue Apr 27 14:18:53 2010, kiwamu, Update, Green Locking, waist positon of Gaussian beam in PPKTP crystals mode_in_PPKTP.png
Entry  Mon May 10 20:03:22 2010, Kevin, Update, Green Locking, Green Laser Beam Profile vbp.jpgvbp_residuals.jpghbp.jpghbp_residuals.jpg
    Reply  Mon May 10 22:25:03 2010, Koji, Update, Green Locking, Green Laser Beam Profile 
    Reply  Tue May 11 14:39:17 2010, Aidan, Update, Green Locking, Green Laser Beam Profile P5110057_beams.jpg
    Reply  Tue May 11 17:02:43 2010, Kevin, Update, Green Locking, Green Laser Beam Profile vbp.jpgvbp_residuals.jpghbp.jpghbp_residuals.jpg
Entry  Wed May 12 02:35:13 2010, Koji, Rana, Kiwamu, Update, Green Locking, Reflection from ETM and ITM ! 
    Reply  Wed May 12 03:42:38 2010, Koji, Update, Green Locking, Green Laser Beam Profile 
    Reply  Wed May 12 03:52:54 2010, Koji, Update, Green Locking, Reflection from ETM and ITM ! 
    Reply  Wed May 12 09:16:29 2010, steve, Update, Green Locking, Reflection from ETM and ITM ! 
    Reply  Wed May 12 10:33:32 2010, kiwamu, Update, Green Locking, Re: Reflection from ETM and ITM ! 
    Reply  Wed May 12 12:25:11 2010, Koji, Update, Green Locking, Re: Reflection from ETM and ITM ! 
    Reply  Fri May 14 08:18:46 2010, steve, Update, Green Locking, Reflection from ETM and ITM ! itmx1hzos.jpg
ELOG V3.1.3-