  15364   Wed Jun 3 01:34:53 2020 gautamUpdateLSCLock acquisition update portalHighlights:


With better ASC servos
implemented, I think the lock stability has
  
  15366   Wed Jun 3 01:46:14 2020 gautamUpdateLSCCARM loop Summary:

The CARM loop now has a UGF of
~12 kHz with a phase
 CM_loop_topology.pdfCARM_TFs.pdfCARM_OLTF.pdfCARM_xover.pdfCARM_OLG_evolution.pdf 
  15367   Wed Jun 3 02:08:00 2020 gautamUpdateLSCPower buildup diagnosticsAttachments
#1 and 
 PRFPMIcorner_DC_1275190251_1275190551.pdfPRFPMIcorner_SB_1275190251_1275190551.pdf 
  15369   Wed Jun 3 03:29:26 2020 KojiUpdateLSCLock acquisition update portalWoo
hoo!

Which 1f signals are
you going to use? PRCL has sign flipping
  
  15371   Wed Jun 3 11:40:56 2020 gautamUpdateLSCLock acquisition update portalFor these initial attempts, I was just
trying to transition MICH to REFL55Q. I agree,
the PRCL situation may be more complicated.
  
  15372   Wed Jun 3 18:49:47 2020 gautamUpdateLSCPRG and CARM signal signSummary:

I am inclined to believe that the
arm cavity losses are such that the 
 armCavReflectivities.pdfIFOreflectivities.pdfPDHerrSigs.pdfPRGvsLoss_finesse.pdf 
  15419   Fri Jun 19 17:06:50 2020 gautamUpdateLSCWhat should the short-term commissioning goals be?Summary:

 CARM_superBoost.pdf 
  15427   Wed Jun 24 17:20:16 2020 gautamUpdateLSCWhat should the short-term commissioning goals be?Per the discussion at the meeting today,
the plan of action is:


Lock the PRMI on carrier
  
  15442   Tue Jun 30 10:59:16 2020 gautamUpdateLSCThree sensing matricesSummary:

I injected some sensing lines and
measured their responses in the various photodiodes,
 PRMI_1f_20200625sensMat.pdfPRFPMI_20200629sensMat.pdfPRFPMI_20200629sensMat_wOffset.pdf 
  15457   Mon Jul 6 17:41:19 2020 gautamUpdateLSCAn LSC puzzlerLast Tuesday evening, while attempting
the PRFPMI locking, I noticed a strange feature
in the LSC signals, which is shown in 
 LSCsignals.jpg 
  15466   Fri Jul 10 01:25:28 2020 gautamUpdateLSCLocking notesMore tomorrow, but I tried the following
tonight:


Dither alignment for PRC
  
  15468   Fri Jul 10 15:26:28 2020 gautamUpdateLSCMC2 coils need DC balancing?I was looking at some signals from last
night, see Attachment
 MC2_balancing.pngASDC.png 
  15470   Sat Jul 11 18:24:30 2020 KojiUpdateLSCMC2 coils need DC balancing?> Can't
we offload this DC signal to the laser crystal
  
  15471   Sun Jul 12 02:42:01 2020 gautamUpdateLSCLocking (on rossa)Main goals tonight were:


Check if I can lock the
interferometer by working on rossa - indeed,
 ASCsteps.png 
  15474   Mon Jul 13 11:36:08 2020 ranaUpdateLSCMC2 coils need DC balancing?
if IMC REFL is not increasing,
I don't think its a mis-alignment. Usually,
REFL is a more sensitive indicator of alignment
  
  15476   Tue Jul 14 00:06:09 2020 gautamUpdateLSCLocking with POX for CARMI tried using the POX_I error signal for
the DC CARM_B path today a couple of times.
Got to a point where the AO path could be
  
  15477   Tue Jul 14 01:55:03 2020 KojiUpdateLSCLocking with POX for CARMThe usual technique is that keeping the
IFO locked with the old set of the signals
and the relative gain/TF between the conventional
  
  15481   Tue Jul 14 17:28:29 2020 gautamUpdateLSCLocking with POX for CARMFrom Attachment
#1, looks like the
 PRFPMI_2020712sensMat.pdfLSCerrSigs.pdf 
  15714   Mon Dec 7 14:32:02 2020 gautamUpdateLSCNew demod phases for POX/POY lockingIn favor of keeping the same servo gains,
I tuned the digital demod
phases for the POX and POY photodiode signals
 POX_POY_OLTF.pdfPOX_POY_spectra.pdf 
  15715   Mon Dec 7 22:54:30 2020 gautamUpdateLSCModulation depth measurementSummary:

I measured the modulation depth
at 11 MHz andf 55 MHz using an optical beat
 modDepth.pdf 
  15718   Wed Dec 9 12:02:04 2020 gautamUpdateLSCPOX locking still unsatisfactoryContinuting the IFO recovery - I am unable
to recover similar levels of TRX RIN as I
had before. 
 armRIN.pdfPOX_OLTF.pdf 
  15750   Wed Jan 6 19:00:04 2021 gautamUpdateLSCPhase loss in POX/POY loopsI've noticed that there is some phase
loss in the POX/POY locking loops - see 
 POXloop.pdfloopFit.pdf 
  15768   Fri Jan 15 17:04:45 2021 gautamUpdateLSCMessed up LSC sensingI want to lock the PRFPMI again (to commission
AS WFS). Have had some
success - but in doing characterization,
 PRFPMI_Jan12sensMat.pdfPRMI3f_ALS_Jan11_largeOffsetsensMat.pdf 
  15769   Sat Jan 16 18:59:44 2021 gautamUpdateLSCModulation depth measurementI decided to analyze the data I took in
December more carefully to see if there are
any clues about the weird LSC sensing.
 PLL.pdfmodDepth.pdfmodProfile.pdfEOMpath_postMod.pdf 
  15822   Fri Feb 19 13:38:26 2021 gautamUpdateLSCPRFPMII forgot that I had already done some investigation
into recovering the PRFPMI lock after my
work on the RF source. I don't really
  
  15827   Fri Feb 19 18:22:42 2021 ranaUpdateLSCPRFPMI sensiing matrix woesI would:


look at the free swingin
michelson. Should be able tu null that siggnal
  
  15849   Sun Feb 28 16:59:39 2021 rana, gautamUpdateLSCmore PRMI checks here: what it is ain't exactly clearOn Friday evening we checked out
a few more things, somewhat overlapping with
previous tests. All tests done with PRMI
 RAMestimate.png 
  15850   Sun Feb 28 22:53:22 2021 gautamUpdateLSCmore PRMI checks here: what it is ain't exactly clearI looked into this a bit more and crossed
off some of the points Rana listed. In order
to use REFL 55 as a sensor, I had to fix
 PRMI_SBres_REFL55.pngPRMI1f_noArmssensMat.pdfPRMI1f_noArmssensMat.pdfPRMI_locked.pngactTFs.pdf 
  15853   Mon Mar 1 16:27:17 2021 gautamUpdateLSCPRM violin filter excessive?The PRM violin filter seems very suboptimal
- the gain peaking shows up in the MICH OLTF,
presumably due to the MICH-->PRM LSC output
 violins.pdfPRviolin.pdf 
  15854   Tue Mar 2 13:39:31 2021 ranaUpdateLSCPRM violin filter excessive?agreed, seems excessive. I always prefer
bandstop over notch in case the eigenfrequency
wanders, but the bandstop could be made to
  
  15855   Tue Mar 2 19:52:46 2021 gautamUpdateLSCREFL55 demod board reworkThere were multiple problems with the REFL55
demod board. I fixed them and re-installed
the board. The TFs and noise measured on
  
  15859   Wed Mar 3 22:13:05 2021 gautamUpdateLSCREFL55 demod board reworkAfter this work, I measured that the orthogonality
was poor. I confirmed on the bench that the
PQW-2-90
  
  15861   Thu Mar 4 10:54:12 2021 Paco, AnchalSummaryLSCPOY11 measurement, tried to lock Green Yend laser[Paco, Anchal]

- First ran burtgooey as last time.

- Installed pyepics on base environment
 20210304_POY11_Spectrum_YARMLocked.pdf20210304_POY11_Spectrum_YARMLocked.tar.gz 
  15862   Thu Mar 4 11:59:25 2021 Paco, AnchalSummaryLSCWatchdog tripped, Optics damped backGautam came in and noted that the optics
damping watchdogs had been tripped by a >5
magnitude earthquake somewhere off the coast
  
  15864   Thu Mar 4 23:16:08 2021 KojiUpdateLSCREFL55 demod board reworkA new hybrid splitter (DQS-10-100) was
installed. As the amplification of the final
stage is sufficient for the input level of
 D990511-00_REFL55.pdfP_20210304_215602.jpgP_20210304_222400.jpgP_20210304_222412.jpg20210304234400_IMG_0526.jpg 
  15867   Fri Mar 5 13:53:57 2021 gautamUpdateLSCREFL55 demod board rework0 dBm ~ 0.63 Vpp. I guess there is ~4dB
total loss (3dB from splitter
and 1dB from total excess loss above theoretical
  
  15869   Fri Mar 5 15:31:23 2021 KojiUpdateLSCREFL55 demod board reworkMissed to note: The IF test was done at
TP7 and TP6 using pomona clips i.e. brefore
the preamp.
  
  15871   Fri Mar 5 16:24:24 2021 gautamUpdateLSCREFL55 demod board re-installed in 1Y2I don't have a good explanation why,
but I too measured similar numbers to what
Koji measured. The overall conversion gain
 REFL55.pdfdemodNoise.pdf 
  15873   Fri Mar 5 22:25:13 2021 gautamUpdateLSCPRMI 1f SB locking recoveredNow that the REFL55 signal chain is capable
of providing balanced, orthogonal readout
of the two quadratures, I was able to recover
 PRMI1f_noArmssensMat.pdf 
  15874   Sat Mar 6 12:34:18 2021 gautamUpdateLSCSensing matrix settings messed withTo my dismay, I found today that somebody
had changed the oscillator frequencies for
the sensing matrix infrastructure we have.
 sensMat.png 
  15875   Sun Mar 7 15:26:10 2021 gautamUpdateLSCHousekeeping + more PRMI
Beam pointing into PMC was tweaked
to improve transmission.
AS110
photodiode was re-installed on the AS table
 PRMI_SBres.pngMICH_act_calib.pdf 
  15876   Sun Mar 7 19:56:27 2021 AnchalUpdateLSCSensing matrix settings messed withI understand this mst be frustrating for
you. But we did not change these settings,
knowingly atleast. We have documented all
  
  15883   Mon Mar 8 22:01:26 2021 gautamUpdateLSCMore PRMIThere are still many mysteries remaining
- e.g. the MICH-->PRCL contribution still
can't be nulled. But for now, I have
 PRMI1f_noArmssensMat.pdfPRMI3f_noArmssensMat.pdf 
  15892   Wed Mar 10 00:32:03 2021 gautamUpdateLSCPRFPMiThe interferometer can nearly be locked
again. I was unable to fully hand off control
from ALS-->RF, I suspect I may be using
 PRMI3f_ALSsensMat.pdf 
  15899   Wed Mar 10 19:58:27 2021 gautamUpdateLSCSR785 hooked up to CM boardIn preparation for later today evening.
The TT alignment wasn't visibly disturbed.
  
  15900   Thu Mar 11 01:45:42 2021 gautamUpdateLSCPRFPMi
PRM satellite box indeed seems
to have been the culprit - shortly after
I swapped it to the SRM, its shadow sensors
  
  15903   Thu Mar 11 14:03:02 2021 gautamUpdateLSCAO pathThere is some evidence of weird saturation
but the gain balancing (0.8dB) and orthogonality
(~89 deg) for the daughter board on the REFL11
 IMG_9127.HEIC 
  15906   Thu Mar 11 20:18:00 2021 gautamUpdateLSCHigh bandwidth POYI repeated the high bandwidth POY locking
experiment.


The "Q" demod
 OLGevolution.pdfinLoopSpec.pdf 
  15917   Fri Mar 12 19:44:31 2021 gautamUpdateLSCDelay lineI may want to use the delay line phase
shifter in 1Y2 to allow remote actuation
of the REFL11 demod phase (for the AO path,
  
  15918   Fri Mar 12 21:15:19 2021 gautamUpdateLSCcoronaversary PRFPMiAttachment
#1 - proof that the
 PRFPMI.pngCARM_OLTF.pdf 