  15786   Mon Feb 1 12:30:21 2021 gautamUpdateElectronicsMore careful characterizationSummary:


Swapping out the KEPCO
HV supplies (linear) I was using for a pair
 HVPS.pdfHV_testckt.pdftotalNoise.pdf 
  11432   Tue Jul 21 05:17:09 2015 IgnacioUpdateGeneralMore clear accelerometer huddle tests resultsI generated the following plots from the
two sets of huddle test data we have for
the accelerometers. 
 new_data.pngnew_data.pngold_data_1.pngold_data_1.pngold_data_2.png 
  15365   Wed Jun 3 01:40:13 2020 gautamUpdateElectronicsMore electronics woesThere were many locklosses from the point
where the arm powers were somewhat stabilized.
 glitchySeis2.pngglitchySeis3.png 
  899   Fri Aug 29 12:41:26 2008 josephb, EricConfigurationComputersMore front ends moved to new networkUsed Cat6 cables to finish moving all the
front ends in 1Y4 and 1Y5 over to the new
GigE network switches, specifically to the
  
  15199   Fri Feb 7 15:00:16 2020 gautamUpdateLSCMore high BW POY experimentsTo study the evilution of the AO path TFs
a bit more, I've hooked up POY11_Q Mon
to IN1 of the CM board. I will revert the
 AO_TFs.pdf 
  15200   Fri Feb 7 19:39:10 2020 KojiUpdateLSCMore high BW POY experimentsThis measurement tells you how the gain
balance between the SLOW_CM and AO paths
should be. Basically, what you need is to
  
  75   Wed Nov 7 02:14:08 2007 AndreyBureaucracyIOOMore information about MC2 ringdownAs Tobin wrote two hours ago, we (Andrey,
Tobin, Robert) made a series of ringdown
measurements for MC2
 9x 
  15628   Thu Oct 15 10:42:39 2020 gautamUpdateBHDMore investigation into RF44 sensingSummary of discussion between
Koji and gautam on 14 Oct:


Koji questioned the accuracy
 analogZetaLock.pngrelPhaseNoise.pdfsigMagPhase.pdf 
  9561   Fri Jan 17 11:44:25 2014 GabrieleSummaryLSCMore length measurements, more confusion I analyzed the data taken yesterday. 
The AS11 data in PRMI configuration
is very bad, while the AS55 seems good enough:
 results_as11.pdfresults_as55.pdf 
  14938   Fri Oct 4 00:32:24 2019 gautamUpdateALSMore locking updatesSummary:

I managed to achieve a few transitions
of control of the XARM length using the ALS
 ALS_singleArm.pngALS_OOL_20191003.pdf 
  14996   Tue Oct 29 01:24:45 2019 gautamUpdateLSCMore locking updatesSummary:


The two arm lengths can
be controlled reliably in the CARM/DARM basis
 POP22_feature.pngPRMI3f_ALS_Oct21sensMat.pdf 
  14997   Tue Oct 29 15:13:19 2019 gautamUpdateLSCMore locking updatesI looked at some signals for a 10 second
period when the PRMI was locked with at some
CARM offset, just before the PRMI lost lock,
 PRMI_lockloss.png 
  14998   Tue Oct 29 17:40:48 2019 gautamUpdateLSCMore locking updatesI set up a photodiode (PDA10CF) in the
IFO REFL beampath and the Agilent NA is sitting
on the east side of the PSL enclosure. This
 broadSweep.pdfzoomSweep.pdf 
  14999   Wed Oct 30 01:27:00 2019 gautamUpdateLSCMore locking updatesTried a bunch of things tonight.


Modified the "ELP300"
filter module in the MICH filter bank - this
 POP_ASS.png 
  15281   Thu Mar 19 03:33:28 2020 gautamUpdateLSCMore locking updatesSome short notes, more details tomorrow.


I was able to make it to
CARM on RF only ~10 times tonight.
Highest
 PRFPMI_lock.pngCARMTF.pdfDARM_AvB.pdflockLoss.png 
  7109   Tue Aug 7 21:34:50 2012 YaakovUpdateSTACISMore noise dataYesterday I plugged the geophone and
accelerometer output into the ADC, rather
than the SR785, so I could collect for longer
 budget.bmpbudget.fig 
  7112   Tue Aug 7 23:33:44 2012 ranaUpdateSTACISMore noise dataLooks like you're just measuring the ADC
noise. You should add ADC noise to your plot.
To compare the geophones with the accelerometers,
  
  4941   Tue Jul 5 18:57:10 2011 JamieUpdateSUSMore normalization of all sus controllersBased on Rana's
comment I have gone through and moved
all of the corner frequencies for the high
  
  4942   Tue Jul 5 21:26:51 2011 ranaUpdateSUSMore normalization of all sus controllersThis is getting closer, but with the whitening
left OFF and the cts2um filter also OFF,
none
 Screenshot-1.png 
  4945   Wed Jul 6 11:45:20 2011 JamieUpdateSUSMore normalization of all sus controllers


   
        
            
  
  15565   Wed Sep 9 00:05:18 2020 gautamUpdateBHDMore notes on the RF44 schemeSummary:


With the Michelson locked
on a dark fringe, the f2-f1 signal at ~44
 IMG_3397.JPGphaseNoisePSD.pdfmagnitudeHist.pdfLOpowerDrift.png 
  15575   Tue Sep 15 22:11:52 2020 gautamUpdateBHDMore notes on the RF44 schemeSummary:

After more trials, I
 RF44.pdf 
  1174   Thu Dec 4 13:49:39 2008 JenneUpdatePEMMore of: Comparing Wiener subtraction using different sensorsHere is another version of the same type plot
I put in the elog yesterday.  This plot is
looking at the 7200 seconds after 04Dec2008
 Dec042008_c1wino_seisCombos.png 
  396   Sun Mar 23 00:56:42 2008 JohnUpdateLSCMore on 3f We ended our last attempt at 3f locking concerned
about the beam size on PD6. I investigated
tonight. The beam was not obviously overfilling
  
  3326   Thu Jul 29 22:08:32 2010 AlbertoUpdateSUSMore optics installed on the BS table[Koji, Steve, Kiwamu, Alberto]
- This afternoon we installed
a few new optics on the BS table: GR_PBS,
  
  3329   Fri Jul 30 02:54:04 2010 KojiUpdate40m UpgradingMore optics installed on the BS tableJuly 29 Thu [Steve, Alberto, Kiwamu,
Koji]
We
  
  630   Thu Jul 3 13:12:32 2008 Rob, Yoichi, JohnUpdateLockingMore oscillationsBounce/ roll filters were added to the short
degrees of freedom to reduce the effect of
the 24Hz line seen on Tuesday night.
 LOL.pngNoisyX080702.pngPOXforCARM080702.png 
  7393   Sat Sep 15 18:29:25 2012 JenneUpdateGeneralMore photos taken{EricQ, Jenne]
More photos were taken.  Will
post Monday, because too hungry now.
  
  7397   Mon Sep 17 13:39:32 2012 JenneUpdateGeneralMore photos taken

    

       
            
 AllPhotos_Sept2012.pdf 
  2057   Tue Oct 6 10:09:55 2009 ZachUpdatePSLMore picturesI'm back to terrorize the PSL table again.
The pictures I took yesterday were rubbish--today
I'm using a clamp that Steve was nice enough
  
  13831   Thu May 10 14:13:22 2018 gautamUpdateGeneralMore refinement of DARM control signal projectionSummary:


It
seems that after a x10 increase in the coil
 darmProj.pdfdarmOLTF.pdfDWcomparison.pdf 
  13833   Fri May 11 13:58:42 2018 ranaUpdateGeneralMore refinement of DARM control signal projectionI think "OLG" trace is not labeled
right; it would be good to see the actual
OLG in addition to whatever that trace actually
  
  13835   Fri May 11 19:02:52 2018 gautamUpdateGeneralMore refinement of DARM control signal projectionI was a bit hasty in posting the earlier
plots. In the earlier plot, the "OLG"
trace was OLG * anti dewhitening as Rana
 darmProj.pdfdarmOLTF.pdfDWcomparison.pdfDARMsuppression.pdfControlLoop.pdf 
  13836   Sat May 12 10:02:03 2018 ranaUpdateGeneralMore refinement of DARM control signal projectionGood question! I've never calculated
what the resonance frequency would be if
had an inductive resistor with our cable
  
  324   Tue Feb 19 18:28:41 2008 JohnUpdatePEMMore seismic in Baja CaliforniaSteve spotted more activity from the same
quake. 
  
  12567   Tue Oct 18 17:11:42 2016 YinziUpdateGreen LockingMore serial port troubleshootingI connected to the serial port using   
  15730   Thu Dec 10 22:45:42 2020 gautamUpdateSUSMore spare OSEMsI acquired several spare OSEMs (in unknown
condition) from Paco. They are stored alongside
the shipment from UF.
  
  11143   Sat Mar 14 01:14:09 2015 JenneUpdateLSCMore stable DARM transitions[Jenne, Koji, Rana]

Thanks to turning off the AS55
analog whitening as well as the 1k:6k lead
 DARM_RF-only_13Mar2015.pdf 
  11144   Sun Mar 15 18:49:57 2015 JenneUpdateLSCMore stable DARM transitionsI have modified the DARM model from elog
11133, to include the fact that these
 DARM_modelVsmeas_15March2015.pngDARMresiduals.png 
  8517   Wed May 1 00:05:03 2013 KojiUpdateLSCMore stable lock of PRMI (REF33I and AS55Q)[Jenne Koji]
- Today the spots were moving more
than the usual. The OPLEV screens showed
 Screenshot.png 
  6596   Thu May 3 13:19:17 2012 JenneUpdateLockingMore success last nightI locked each arm, and the Michelson last
night, no problems after I increased the
Yarm gain from 0.1 to 0.2 .  I checked
  
  15675   Thu Nov 12 14:55:35 2020 gautamUpdateElectronicsMore systematic noise characterizationSummary:

I now think the excess noise in
this circuit could be coming from the KEPCO
 powerSupplyNoise.pdfcoherence.pdf 
  15676   Thu Nov 12 15:40:42 2020 KojiUpdateElectronicsMore systematic noise characterizationYes. The datasheet has a recommendation
circuit with 10uF caps. Companies are careful
to show reproducible, reliably functional
  
  15677   Mon Nov 16 00:02:34 2020 ranaUpdateElectronicsMore systematic noise characterizationtrue. also try to choose a cap with a goow
high frequency response. In the Electronics
Noise book by Ott there's some graph
  
  6908   Tue Jul 3 18:58:14 2012 YaakovUpdateSTACISMore transfer functions and netGPIB statusI'm still having issues with the STACIS
oscillating uncontrollably with the slightest
extra vibration, but with some more added
 geo_open_y.pnggeo_open_x.pngaccel_open_x.png 
  14490   Thu Mar 21 12:46:22 2019 JonUpdateVACMore vac controls upgradesThe vac controls system is going down for
migration from Python 2.7 to 3.4. Will advise
when it is back up.
  
  14491   Thu Mar 21 17:22:52 2019 JonUpdateVACMore vac controls upgradesI've converted all the vac control
system code to run on Python 3.4, the latest
version available through the Debian
  
  15686   Mon Nov 23 16:33:10 2020 gautamUpdateVACMore vacuum deliveries Five Agilent pressure gauges were delivered
to the 40m. It is stored with the controller
and cables in the office area. This completes
  
  7097   Mon Aug 6 20:27:59 2012 JamieUpdateSimulationsMore work on getting simplant models running: c1lsp and c1supI'm trying to get more of the simplant
models running so that we (me and Sasha Surf)
can get a full real-time cavity simplant
  
  2159   Thu Oct 29 18:04:02 2009 JenneUpdateAdaptive FilteringMore work on saving coeffs on the OAF screen[Sanjit,Jenne]
Sanjit has been working today on
trying to get the OAF coefficients to save
  