  7398   Mon Sep 17 18:04:01 2012 SteveUpdateCOC2 Layout Changes

    

       
            
 IMG_1635.JPG 
  7399   Mon Sep 17 20:23:31 2012 JenneUpdateGeneralLast of In-vac mirror photos taken[Manasa, Jenne]
We took the last of the in-vac photos
of mirrors today.  I'll post in the
  
  7400   Mon Sep 17 23:58:01 2012 ranaUpdateGeneralLast of In-vac mirror photos taken My hope is that the DRMI flashes
will be bright enough to see on the PO beams.
IF we get 10 mW through the Faraday, you
  
  7401   Tue Sep 18 11:53:12 2012 JenneUpdateGeneralLast of In-vac mirror photos taken

    

       
            
 AllPhotos_Sept2012.pdf 
  7402   Tue Sep 18 18:24:50 2012 JenneUpdateGeneralScattering in BS chamber or ITMX chamberI have touched PZT2 such that the beam
goes through the 45 degree non-iris target
on the beam splitter.  This puts the
  
  7403   Tue Sep 18 20:32:42 2012 ManasaConfigurationPSLAOM installation {Jan, Manasa}
We tried towards calibrating the
RF driver of the AOM. We decided to use the
  
  7404   Tue Sep 18 22:06:21 2012 Mike J.UpdateElectronicsAS beam scan plots and chi-squaredResults of the Razor Blade Beam Scan
The horizontal blade test measured
the beam intensity as a razor blade passed
 beam_width.pyH_raz.pngV_raz.png 
  7405   Wed Sep 19 01:08:48 2012 JenneUpdateGeneralDRMI aligned againThe DRMI was aligned once again tonight. 
Here's a video: http://youtu.be/Cy8nHL9yMeM 
(Can someone please tell me / remind me how
 DRMI_aligned_19Sept2012_ETMYwasHighNeedToFix.png 
  7406   Wed Sep 19 01:15:15 2012 JenneUpdateGeneralLast of In-vac mirror photos taken - NOT!I'm making a separate entry to go along
with this thread of photos...
Putting the camera and 'bathroom'
  
  7407   Wed Sep 19 09:24:01 2012 SteveOmnistructureIOOaccess connector at athmoshere

    

       
            
 IMG_1641.JPGIMG_1642.JPGacetateAC.png 
  7408   Wed Sep 19 09:32:24 2012 SteveUpdateSUSalignment centering jigSOS alignment tool with ID 9.5 and 6.3
mm
 IMG_1639.JPGIMG_1651.JPG 
  7409   Wed Sep 19 11:39:37 2012 ManasaConfigurationPSLAOM installation

    

       
            
 ALC_25.png 
  7410   Wed Sep 19 13:12:48 2012 JenneUpdateIOOPower into vacuum increased to 75mWThe power buildup in the MC is ~400, so
100mW of incident power would give about
40W circulating in the mode cleaner.
  
  7411   Wed Sep 19 15:41:27 2012 ManasaConfigurationPSLAOM installation 
 AOM driver has been removed
from the PSL table for testing. However the
  
  7412   Wed Sep 19 17:48:47 2012 DenUpdateModern ControlETMXTime domain control using LQR technique
is now applied to ETMX sus position. The
plan was to do it for oplevs, I'll do it
 etmx_suspos.png 
  7413   Wed Sep 19 19:38:37 2012 JenneUpdateGeneralSpot centered on BS, ETMY, ETMX[Unni, Manasa, Jenne]
It turned out that the beam was a
teeny bit high in the corner, so we touched
  
  7414   Wed Sep 19 23:17:25 2012 ranaConfigurationPSLAOM installationMannasa and Unni and I looked at the
RF driver for the AOM. It was fine.
With the ALC input left unconnected,
  
  7415   Thu Sep 20 01:28:14 2012 JenneUpdateGeneralDRMI aligned again, but with good arms[Jenne, Manasa]
Using the alignment of the PZTs and
BS from pre-dinner, where the beam was hitting
  
  7416   Thu Sep 20 01:29:04 2012 ManasaConfigurationPSLAOM installation

    

       
            
 TEK00000.PNG 
  7417   Thu Sep 20 08:34:46 2012 ManasaUpdateGeneralDRMI aligned again, but with good arms

    

       
            
  
  7418   Thu Sep 20 08:50:14 2012 MashaUpdateMachineLearningMachine Learning Update Hi everyone,
I've been working a bit on neural
network code for a controller, and thus far
  
  7419   Thu Sep 20 11:39:40 2012 ManasaUpdateGeneralDRMI aligned again, but with good arms 
 QPD at IPPOS has been centered
by removing the filter at the QPD.
  
  7420   Thu Sep 20 14:55:06 2012 JenneUpdateGeneralPickoffs are hard to see

    

       
            
  
  7421   Thu Sep 20 17:05:26 2012 JenneUpdateGeneralREFL, IPANG are coming out of the vac[Jenne, Unni, Manasa]
I touched some in-vac steering mirrors,
so we have REFL and IPANG coming out of the
  
  7422   Thu Sep 20 19:56:05 2012 JenneUpdateGeneralPickoffs are hard to see

    

       
            
  
  7423   Thu Sep 20 20:07:38 2012 JenneUpdateGeneralREFL, IPANG are coming out of the vac

    

       
            
  
  7424   Thu Sep 20 22:52:38 2012 DenUpdateMachineLearningFeedback controller

    

       
            
  
  7425   Fri Sep 21 12:12:56 2012 ManasaConfigurationPSLAOM installation    {Jan, Manasa}
We installed the AOM driver back
on the PSL table this morning. To calibrate
 PSL.png 
  7426   Fri Sep 21 20:48:24 2012 JenneUpdateGeneralPOP in-vac optics aligned, POY beam coming out of vacGetting POP:
We put a green laser pointer at ~4
inches on the POX table, and steered it using
  
  7427   Fri Sep 21 22:25:44 2012 Mike J.UpdateGeneralPOX, POY, PR2 picsUnaltered PR2 images, with IR card, without
card, and steering mirror:
 10x 
  7428   Fri Sep 21 22:43:51 2012 DenUpdateSUSTT alignmentI did TT alignment using red laser and
QPD.
 6x 
  7429   Sat Sep 22 01:03:30 2012 DenUpdatePEMETMY tableI've installed Guralp readout box back
and it turned out that it does not work with
voltage provided from the rack (+13.76 0
 X.pdfY.pdfZ.pdf 
  7430   Sun Sep 23 22:40:48 2012 DenUpdateModern ControlMC_L lockingI've applied LQR approach to MC_L locking.
Results show that LQR does not make MC_F
signal smaller below 0.3 Hz in contrast with
 LQR_MCL.pdf 
  7431   Mon Sep 24 10:27:50 2012 SteveOmnistructureGeneraldo not leave stuff on optical table topsThe SP table was found open this morning.
 Please, do not make optics dirty!
  
  7432   Mon Sep 24 16:59:31 2012 JenneUpdateVACDoors on, ready to pump[The 40m Family]
The access connector and all heavy
doors are back on. 
  
  7433   Mon Sep 24 17:03:39 2012 JenneUpdatePEM1X1 rack power

    

       
            
  
  7434   Mon Sep 24 17:47:05 2012 SteveUpdateVAC ready to pump  The IFO will be at atmosphere 
overnight. The annuloses are pumped
down. The access connector jam nuts are tightened
  
  7435   Mon Sep 24 20:28:13 2012 ranaSummaryelogrestarted elog: was unresponsive    
  7436   Mon Sep 24 23:45:39 2012 ranaUpdateGeneralPOP in-vac optics aligned, POY beam coming out of vac  What was the reasoning / resolution
of the POP forward/backward beam? Are we
going to have the right beam for DRMI locking?
  
  7437   Tue Sep 25 14:29:07 2012 JenneUpdateGeneralPOP in-vac optics aligned, POY beam coming out of vac

    

       
            
  
  7438   Tue Sep 25 17:21:01 2012 SteveUpdateVACpumpdown completed IFO P1= 1mTorr,   CC1 =
5e-4 Torr.  The IFO is ready for work.
Be free to open the shutter and turn on HV
 pd73.pngpd73b.png 
  7439   Tue Sep 25 22:40:55 2012 JenneUpdateIOOIPANG ND filter installed[Jenne, Evan Hall]
Both IPPOS and IPANG beams are (after
turning on the input and output PZTs) hitting
  
  7440   Wed Sep 26 01:10:34 2012 JenneUpdateIOOPZT2 not working?!?! MC back to normal[Jenne, Evan, Den]
MC REFL beam is back on the PD,
and the mode cleaner locks.  It
  
  7441   Wed Sep 26 11:03:04 2012 SteveUpdateVACpumpdown completed The new cold cathode gauge CC1 is
in place. We were at atmosphere for 28 days
......more later
 40mpd73md1.png28datm.png 
  7442   Wed Sep 26 16:59:30 2012 jamieUpdateIOOIPANG ND filter installed

    

       
            
  
  7443   Wed Sep 26 17:09:15 2012 DenUpdateSUSTT  [Koji, Steve, Den]
TT alignment is fine, yaw damping
is satisfactory, pitch damping is slow. We
  
  7444   Wed Sep 26 23:55:14 2012 JenneUpdateIOOWFS centeredSince the MC spots are good, I put the
beam back on WFS 1 and WFS 2.
Also, I changed the indicators on
  
  7445   Thu Sep 27 13:05:55 2012 Eric GustafsonUpdateLSC40 meter photodiode frequency response measurement system installationJenne, Mike and   
  7446   Thu Sep 27 15:21:04 2012 SteveUpdateSUSTT height adaptor & PTICH damping

    

       
            
 09271201.PDFIMG_1656.JPGIMG_1654.JPG 
  7447   Thu Sep 27 16:26:11 2012 SteveUpdateLSCRF fibre protection in cable trays

    

       
            
  