  12395   Wed Aug 10 18:10:26 2016 PrafulUpdateElectronicsMic AmplifierI set up 3 of my circuits in the interferometer
near MC2 to do a huddle test. I have the
signals from my microphones going into C1:PEM-MIC_1_IN1,
 huddle_setup.jpgmore_setup.jpgmic_setup.jpg 
  12400   Thu Aug 11 11:51:38 2016 PrafulUpdateComputer Scripts / ProgramsSummary PagesThe summary pages have been updated with
the new naming seismometer channel naming
conventions. Here's a link to them working
  
  12402   Thu Aug 11 17:30:05 2016 PrafulUpdateElectronicsMic AmplifierThe results of my first huddle test were
not so good- one of the signals did not match
the other two very well- so I changed the
 new_setup.jpgnew_setup2.jpg 
  12405   Fri Aug 12 19:13:25 2016 PrafulUpdateElectronicsMic Self NoiseI used the Wiener filtering method described
by Ignacio and Jessica (https://dcc.ligo.org/DocDB/0119/T1500195/002/SURF_Final.pdf
and https://dcc.ligo.org/public/0119/T1500194/001/Final_Report.pdf)
 8x 
  12408   Mon Aug 15 12:23:56 2016 PrafulUpdatePEMMic Self NoiseI didn't have a separate training set
and data set, so I think that's why the
graphs came out looking too good. The units
 9x 
  12427   Sun Aug 21 17:21:22 2016 PrafulUpdateElectronicsProblems with PCB CircuitFor the past week, I've been trying
to make a soldered amplifier circuit to use
in a prototype box, However, I've been
 18x 
  12431   Mon Aug 22 18:35:16 2016 PrafulUpdatePEMthe lab temp is upThe temperature is decreasing slowly but
is still above 24 C.

 temp_plot.pngtemp_plot.pngtemp_plot.png 
  12433   Tue Aug 23 17:05:20 2016 PrafulUpdateElectronicsSoldered Circuit WorkingI remade another soldered circuit, adding
extra 100uF electrolytic bypass capacitors
at the input and output of the voltage regulator
 10x 
  12436   Wed Aug 24 14:11:09 2016 PrafulUpdateElectronicsMicrophone TestingI added an EM172 to my soldered circuit
and it seems to be working so far. I have
taken a spectra using the EM172 in ambient
 white_v_ambient.pngwhite_v_ambient.pdfwhite_v_ambient.pdf 
  12437   Wed Aug 24 14:44:33 2016 PrafulUpdateElectronicsDecoupling capacitor 101Do these look good for the ceramic capacitors?
We're running low.

http://www.mouser.com/ProductDetail/Vishay-BC-Components/K104K15X7RF53L2/?qs=sGAEpiMZZMuMW9TJLBQkXmrXPxxCV7CRo6C15yUYAos%3d
  
  12439   Wed Aug 24 23:47:30 2016 PrafulUpdateElectronicsFinished Prototype BoxGautam helped me drill holes in a metal
box and I set up my circuit inside. Everything
seems to be working so far. Tomorrow I'll
 out1.pdfout2.pdfout3.pdfin1.pdfin2.pdf 
  12442   Thu Aug 25 19:03:56 2016 PrafulUpdateElectronicsAcoustic Tab and Amp SuspensionMy box has been suspended in the PSL using
surgical tubing, and it has been connected
to C1:PEM-MIC_1 (C17) with a BNC. I made
  
  12463   Thu Sep 1 17:25:02 2016 PrafulUpdateElectronicsAcoustic Tab and Amp SuspensionI'll add a picture of the installation
when I get back to campus and finish hooking
up the power cable. I haven't added this
  
  12968   Wed May 3 17:16:30 2017 PrafulUpdateElectronicsNew Altium Schematic Design for Microphone AmpI made an Altium schematic for the microphone
amplifier circuit for fabrication.

mic_schematicv2.pdf
 mic_schematicv2.pdf 
  11138   Thu Mar 12 19:54:31 2015 Q UpdateLSCHow to: PRYQ doesn't like elogging, but he sent
me this nice detailed email, so I'm copying
it into the log:
  
  9296   Sat Oct 26 21:46:33 2013 RANAUpdateIOOMode Cleaner Tune-UP The
MC had been unlocked for the last 4 hours
and was crying out to me so I gave it some
 MCtrend.pdfMC40days.png 
  9298   Sun Oct 27 00:15:35 2013 RANAUpdateSUSc1auxex At some point tonight we lost our
CA connection to c1auxex (which is actually
the computer at the X End and controls the
 arms.pdfarm-mc2-dewhite.pdf 
  9306   Mon Oct 28 21:33:55 2013 RANAUpdateIOOMode Cleaner Tune-UP 
8 day minute trend of some of the
IMC alignment signals.
 Untitled.png 
  9323   Thu Oct 31 20:05:48 2013 RANAUpdateIOOMode Cleaner Tune-UP

    

       
            
 drifty.png 
  9365   Mon Nov 11 22:35:45 2013 RANAUpdateIOOPSL pointing monitoringSince the pointing has gone bad again,
I went to the PSL to investigate. Found some
bad things and removed them:
 qpd.pdf 
  9370   Tue Nov 12 23:48:23 2013 RANAUpdateIOOPSL pointing monitoring    
  9400   Mon Nov 18 19:45:42 2013 RANAUpdateSUSPRM picturesNice camera work Steve! I will use these
for publicity photos.
  
  9521   Mon Jan 6 18:32:17 2014 RANAUpdateIOOMC1/3 kicked this morning at 8:30 The trend shows a big jolt to the
MC1/3 pointing this morning at 8:30.
Was anyone working
 kicked.png 
  9666   Mon Feb 24 17:59:31 2014 RANAUpdateElectronicsMeasured REFL165 demod board  
 Demod boards should be at 90
deg, not 82.7 or 12 or 
  
  17155   Fri Sep 23 14:10:19 2022 RadhikaUpdateBHDBH55 RFPD installed - part I[Radhika, Paco, Anchal]

I placed a lens in the B-beam
path to focus the beam spot onto the RFPD
 IMG_3766.jpegIMG_3770.jpegIMG_3773.jpeg 
  7624   Thu Oct 25 15:38:06 2012 RajiUpdateAlignmentTransmitance Measurements on LaserOptik mirrorI measured the transmitted power @1064nm
on one of the LaserOptik mirrors labled SN6
Here is the data
  
  7644   Wed Oct 31 12:58:17 2012 RajiUpdateAlignmentTransmitance Measurements on LaserOptik mirror

    

       
            
 Transmission-plot@1064nm.pdfTransmission-data@1064nm.pdf 
  3241   Fri Jul 16 23:53:27 2010 RanaUpdatePSLReference Cavity InsulationFrom the trend, it seems that the Reference
Cavity's temperature servo is working fine
with the new copper foil. I was unable to
  
  3280   Fri Jul 23 16:02:16 2010 RanaUpdatePSLReference Cavity InsulationThis is the trend so far with the copper
foil wrapping. According to Megan's calculation,
we need ~1 mm of foil and the thickness of
 Untitled.png 
  3282   Fri Jul 23 21:14:29 2010 RanaUpdatePSLReference Cavity InsulationI wrapped another ~3 layers onto there.
It occurs to me now that we could just get
some 2mm thick copper plates made to fit
  
  7869   Fri Dec 21 16:50:30 2012 RanaUpdateSUSTT in vac DB25 pin swapping[Koji, Rana, Nic, Steve] 
  
  8395   Tue Apr 2 21:11:42 2013 RanaUpdateoptical tablesOptical Table Toolboxes Update

    

       
            
  
  9316   Wed Oct 30 03:33:17 2013 RanaUpdateLSCLSC demod boards need some thought 
 
 0309.png 
  16061   Wed Apr 21 11:01:37 2021 RanaUpdateCDS40m LSC simPlant modelThe controller would be in the c1sus model,
and connects to the c1sup plant model. So
the controller doesn't go in the plant
  
  1954   Wed Aug 26 19:58:14 2009 Rana, AlbertoUpdatePSLReference Cavity Temperature Control: MINCO PID removedSummary: This afternoon we managed
to get the temperature control of the reference
cavity working again.
 rc.png 
  8776   Thu Jun 27 22:52:38 2013 Rana, Gabriele, FrancescoSummaryComputer Scripts / ProgramsLIGO-DV installedI installed ligoDV in the /ligo/apps/ligoDV/
Now, by pointing the tool at the
local NDS2 server (megatron:31200) you can
 ldv.png 
  8387   Tue Apr 2 10:22:37 2013 Rana, Gabriele, JenneUpdateLSCPRMI lockWe locked the PRMI, this time really on
the sidebands, using the two REFL55 signals.
Here are the parameters: triggering
 lock_prmi_sb.pdf 
  2465   Tue Dec 29 13:57:20 2009 Rana, Kiwamu, and HaixingUpdatePhotosPhotos of video switch boxBefore we installed the video switch box,
we also took some photos of it. We uploaded
them onto the 40m Picasa. 
  
  3102   Wed Jun 23 12:28:34 2010 RazibSummaryPhase CameraWeeekly SummaryThis past week I have completed the following
tasks:
 
 trigger-box_circuit.pngtest1.png 
  3146   Wed Jun 30 12:20:49 2010 RazibUpdatePhase CameraWeekly updateThis week I have completed following tasks:
1. Worked out the analytical expressions
for the amount of power of the DC and oscillatory
  
  3167   Wed Jul 7 12:17:36 2010 RazibUpdatePhase CameraWeekly updateI have completed the following tasks:
1. Find a simplified calibration
of the exposure time for the current He-Ne
 DC_1Hz_beat_sig.jpgDC_1Hz_beat_sig.jpgDC_5Hz_beat_sig.jpg 
  3187   Fri Jul 9 12:07:26 2010 RazibUpdatePhase CameraWeekly updateHere are some more details about the current
phasecam setup. We are using a He-Ne laser
setup
 phase_cam_setup_09_08_10.jpgmod_setup_(copy)_annotated.jpg 
  3215   Wed Jul 14 11:51:48 2010 RazibUpdatePhase CameraWork near 1Y2 yesterday


   
        
            
  
  3217   Wed Jul 14 12:12:03 2010 RazibSummaryPhase CameraWeekly updateThis week I was mainly interested in investigating
the noise source at the phase camera. So
having this issue in mind, my activities
  
  3258   Wed Jul 21 12:20:58 2010 RazibUpdatePhase CameraWeekly updateThis past week I have worked on the following:
1. Setting up the infrastructure
to do noise analysis: We added a temporary
 phase_cam_setup_21_07_2010.jpg 
  3309   Wed Jul 28 13:06:47 2010 RazibUpdatePhase Camera Attached are some calculation that I did
previously for the phasecamera setup. This
shows the nature of the beat signal that
 mean_100_snaps.pngstd_100_snaps.pngphase_cam_calc.pdf 
  3411   Thu Aug 12 16:52:02 2010 RazibUpdatePhase CameraSideband power measurement (updated)I made some measurement of the SCR (signal
to contrast ratio) from the signal from the
EOM and the AOM.
 SCR.jpgDC_sig_sideband_profile.jpgsideband_profile.jpgsine_trig.jpgsine_trig.jpg 
  3413   Thu Aug 12 17:28:28 2010 RazibUpdatePhase CameraSideband power measurement (updated)


   
        
            
  
  3360   Wed Aug 4 16:52:59 2010 Razib, AidanUpdatePhase CameraSideband power measurement (updated)Aidan and I made some attempt to measure
the power of the sidebands so that we can
calculate our expected signal strength.
 Setup_08_04_2010.jpgpower_40MHz.pngpower_25MHz.png 
  10221   Wed Jul 16 21:24:41 2014 ReetikaUpdateElectronicsVCO Driver inside 40m  
I
found the VCO driver, that Rana asked me
  