  5422   Thu Sep 15 18:24:54 2011 PaulUpdateSUSITMY and SRM Oplev current status - comparison with ITMYJust to find out where we are currently,
I plotted the ITMY and SRM oplev spectra
along with the ETMY oplev spectra. ETMY seems
 oplev_spectra_comparison.pdf 
  5423   Thu Sep 15 18:31:27 2011 PaulUpdateSUSITMY and SRM Oplev current status - comparison with ITMY

    

       
            
  
  5427   Thu Sep 15 22:26:32 2011 PaulUpdateSUSITMY Oplev QPD dark noise PSD I took a dark noise measurement for
the ITMY QPD, for comparison with measurements
of the oplev noise later on. Initially I
 ITM_dark_QPD_PSD.pdf 
  5429   Fri Sep 16 00:08:30 2011 PaulUpdateSUSITMY Oplev QPD dark and bright noise spectra I tried again at plotting the ITMY_QPD
noise spectra in for dark and bright operation.
Before we had the strange situation where
 ITMY_oplev_dark_noise_vs_bright_noise.pdf 
  5432   Fri Sep 16 14:03:53 2011 PaulUpdateSUSSRM oplev QPD noise measurement I checked the dark and bright noise
of the SRM oplev QPD. The SRM QPD has a rather
high dark level for SUM of 478 counts. The
 SRM_oplev_dark_noise_vs_bright_noise.pdfSRM_ITMY_QPD_dark_noise_comparison.pdf 
  5436   Fri Sep 16 16:34:54 2011 PaulUpdateSUSITMY SRM oplev telescope planI've calculated a suitable collimating
telescope for the ITMY/SRM oplev laser, based
on the specs for the soon-to-arrive 2mW laser
 ITMY_SRM_telescope.png 
  5437   Fri Sep 16 17:09:07 2011 PaulUpdateSUSITMX oplev plan I just drew a basic picture of how
the ITMX oplev path could be reworked to
minimise the number of optics in the path.
 ITMX_oplev_plan.png 
  5442   Fri Sep 16 22:11:21 2011 PaulUpdateSUSITMY transfer functionFirst of all I moved the lenses on the
ITMY/SRM oplev path to get a smaller spot
size on the QPDs. I couldn't get the beam
 ITMY_osem_to_oplev_TF.pdf 
  5443   Fri Sep 16 22:51:52 2011 PaulUpdateSUSCalibration plan for the oplevs In order to estimate the amount of
noise that the oplevs are injecting into
the GW channel, we first need to calibrate
  
  5457   Mon Sep 19 12:23:30 2011 PaulUpdateSUSITMY and SRM oplev beam size reduced + next stepsI replaced the lenses that were there with
a -150mm lens followed by a +250mm lens.
This gave a significantly reduced beam size
  
  5458   Mon Sep 19 13:13:10 2011 PaulUpdateSUSITMY oplev available for use: SRM not for the moment I've got the bench set up for the
measurement of the beam spot change with
DC SRM alignment offsets. The ITMY oplev
  
  5460   Mon Sep 19 15:30:22 2011 PaulUpdateSUSSRM oplev OSEM yaw calibration curve I made the first measurements towards
oplev calibration measurements: calibrating
the oplevs in SRM YAW. The measurements seemed
 SRM_YAW_calib_curve.png 
  5465   Mon Sep 19 16:56:29 2011 PaulUpdateSUSSRM oplev pitch calibration Same measurements for SRM pitch (as
previously done for yaw in entry 5460) are
complete. The QPD is back in the path and
  
  5468   Mon Sep 19 20:56:36 2011 PaulSummarySUSRemaining SRM and ITMY OSEMs calibrations 
I've now taken data for the pitch
and yaw calibrations for the OSEMs of SRM
 SRM_PITCH_calib_curve.pngSRM_YAW_calib_curve.pngITMY_PITCH_calib_curve.pngITMY_YAW_calib_curve.png 
  5487   Tue Sep 20 18:03:45 2011 PaulUpdateSUSITMY and SRM oplev calibrations - measured and estimatedThe measured calibration factors for the
oplevs are as follows:
 
SRM pitch: 666urad
  
  5488   Tue Sep 20 19:00:49 2011 PaulUpdateSUSITMY and SRM oplev calibrations - measured and estimated 
Kiwamu noticed that the 1/L in the
counts per radian should have just been L,
  
  5496   Wed Sep 21 09:10:15 2011 PaulUpdateSUSITMY and SRM oplev calibrations - measured and estimated

    

       
            
  
  5499   Wed Sep 21 14:44:25 2011 PaulUpdateSUSITMY and SRM open loop transfer functions 
 Here are the open loop transfer
functions for ITMY and SRM. The various settings
 ITMY_SRM_oplev_OLTFs.png 
  5501   Wed Sep 21 16:31:28 2011 PaulUpdateSUSITMY and SRM actuator response functions I divided the open loop transfer
functions by the filter response and the
sensor responses (previously measured calibration
 ITMY_PITCH_actuator_response.pngITMY_YAW_actuator_response.pngSRM_PITCH_actuator_response.pngSRM_YAW_actuator_response.png 
  5507   Wed Sep 21 23:05:16 2011 PaulUpdateSUSITMY and SRM actuator response functions - fitting results I used an fminsearch function to
fit the SRM and ITMY actuator response magnitudes.
The testfunction was just that for a single
 ITMY_PITCH_actuator_response_FIT.pngITMY_YAW_actuator_response_FIT.pngSRM_PITCH_actuator_response_FIT.pngSRM_YAW_actuator_response_FIT.png 
  5509   Wed Sep 21 23:44:45 2011 PaulUpdateSUSRe:ITMY and SRM actuator response functions - fitting results

    

       
            
  
  5510   Thu Sep 22 00:00:10 2011 PaulUpdateSUSITMY and SRM actuator response functions - complex fitting resultsHere are the results of the complex fitting.
The residuals are bigger this time, but still
probably small enough to be ok(?), with the
 ITMY_PITCH_actuator_response_complex_FIT.pngITMY_YAW_actuator_response_complex_FIT.pngSRM_PITCH_actuator_response_complex_FIT.pngSRM_YAW_actuator_response_complex_FIT.png 
  5514   Thu Sep 22 10:43:50 2011 PaulUpdateSUSPower spectrum with different filter gains I thought it might be informative
before trying to optimise the filter design
to see how the current one performs with
 ITMY_YAW_closed_vs_open_noise.pdf 
  5517   Thu Sep 22 13:45:17 2011 PaulUpdateSUSETMX actuator response fitsFitting results: 
 Pitch
-- Fit completed after 305 iterations--
 Started
 ETMX_PITCH_actuator_response_complex_fit.pngETMX_YAW_actuator_response_complex_fit.png 
  5532   Fri Sep 23 17:57:34 2011 PaulUpdateSUSOplev filter optimization for 2 poles and 2 zerosI have made a function to optimise
the overall gain, pole frequencies and zero
frequencies for the oplev filter. The script
 optimised2p2z_v1.pngoptimised2p2z_v1_TFs.png 
  5540   Sat Sep 24 17:45:56 2011 PaulUpdateSUSRe:Oplev filter optimization for 2 poles and 2 zeros

    

       
            
  
  5554   Tue Sep 27 08:51:29 2011 PaulUpdateSUSOplev filter optimization for 2 poles and 2 zeros

    

       
            
  
  5419   Thu Sep 15 17:00:10 2011 Paul and SteveUpdateSUSNew ITMY and SRM oplev plan We have made a new plan for the ITMY
and SRM oplev optical path which uses as
few optics as possible. This should help
 oplev_plan1.png 
  1950   Wed Aug 26 16:10:28 2009 Peter KingConfigurationPSLPSL reference cavity temperature box modificationsThe 40m Lab reference cavity temperature
box S/N BDL3002 was modified as per DCN D010238-00-C.
These were:
 DSC_0731.jpg 
  9028   Mon Aug 19 10:16:15 2013 PicassoMetaphysicsTreasureoutsider art   ranasglory.png 
  227   Tue Jan 8 15:20:17 2008 PkpUpdateCamerasGigE update[Tobin , Pinkesh]

Finally we got the camera doing something
  
  234   Thu Jan 10 13:45:52 2008 PkpUpdateCamerasGLIBC ErrorSo, I have tried to compile the camera files
which are in /cvs/cds/caltech/target/Prosilica/examples
for the past 2 days now and have been unable
  
  13862   Fri May 18 09:13:41 2018 PoojaUpdateSUSColored GigE imageTo obtain a colored version with good contrast
of the grayscale image of scattering of light
by dust particles on the surface of test
 Image__2017-11-14__08-25-13_100k100g1V_colored.pngImage__2017-11-14__08-25-13_100k100g1V.tiff 
  13868   Fri May 18 20:03:14 2018 PoojaUpdateCamerasTelescopic lens solution for GigEAim: To find telescopic lens solution to
image test mass onto the sensor of GigE camera.

I wrote a python code to find an
 8x 
  12220   Tue Jun 28 16:09:41 2016 PrafulUpdateGeneral40m Summary PagesSet up gwsumm on optimus and generated
summary pages from both L1 and C1 data. Still
a few manual steps need to be taken during
  
  12221   Tue Jun 28 16:10:49 2016 PrafulUpdateGeneralBluebird MicrophonesFound 1 out of 2 bluebird microphones in
the 40m.
  
  12222   Tue Jun 28 17:11:27 2016 PrafulUpdateGeneralEM172 MicrophonesFound 60 EM172 microphones. Previous elog
with details: 7777.
  
  12239   Fri Jul 1 17:51:28 2016 PrafulSummaryElectronicsReplacing DIMM on OptimusThere has been an ongoing memory error
in optimus with the following messages:

controls@optimus|~
  
  12244   Tue Jul 5 18:44:39 2016 PrafulUpdateComputer Scripts / ProgramsWorking 40m Summary PagesAfter hardware errors prevented me from
using optimus, I switched my generation of
summary pages back to the clusters. A day's
  
  12252   Wed Jul 6 11:02:41 2016 PrafulUpdateComputer Scripts / ProgramsVMon Tab on Summary PagesI've added a new tab for VMon under
the SUS parent tab. I'm still working
out the scale and units, but let me know
  
  12254   Wed Jul 6 17:17:22 2016 PrafulUpdateComputer Scripts / ProgramsNew Tabs and Working Summary PagesThe main C1 summary pages are back online
now thanks to Max and Duncan, with a gap
in pages from June 8th to July 4th. Also,
  
  12275   Fri Jul 8 15:44:07 2016 PrafulUpdateElectronicsReplacing DIMM on OptimusOptimus' memory errors are back so
I found the exact DIMM model needed to replace:
http://www.ebay.com/itm/Lot-of-10-Samsung-4GB-2Rx4-PC2-5300P-555-12-L0-M393T5160QZA-CE6-ECC-Memory-/201604698112?hash=item2ef0939000:g:EgEAAOSwqBJXWFZh
  
  12277   Fri Jul 8 19:33:16 2016 PrafulUpdateComputer Scripts / ProgramsMEDM Tab on Summary PagesA new MEDM tab has been added to the summary
pages (https://nodus.ligo.caltech.edu:30889/detcharsummary/day/20160708/medm/),
although some of the screens are not updated
  
  12280   Fri Jul 8 21:15:03 2016 PrafulUpdateComputer Scripts / ProgramsMEDM Tab on Summary PagesThanks! Yes, only the screens that are
not updated when the script is executed show
this error. I'll try to keep debugging
  
  12329   Mon Jul 25 10:54:55 2016 PrafulUpdateComputer Scripts / ProgramsFinished MEDM Tab on Summary PagesThe MEDM screen capture tab is now working
and up on the summary pages: https://nodus.ligo.caltech.edu:30889/detcharsummary/day/20160725/medm/

Please let me know if you have
  
  12344   Wed Jul 27 22:42:00 2016 PrafulUpdateElectronicsEM172 AmplifierI recreated Den's microphone amplifier
circuit on a solderless breadboard to test
it and make sure it does what it's supposed
 schematic.png 
  12356   Fri Jul 29 19:37:43 2016 PrafulUpdateElectronicsMic AmplifierI set up a test inverting amplifier circuit
using the LT1677 opamp:

 7x 
  12369   Wed Aug 3 18:53:46 2016 PrafulUpdateElectronicsMic AmplifierI could not get Den's circuit to work
for some reason with microphone input, so
I decided to try to use another circuit I
 simple_amp.pngampTest_03-08-2016_180448.pdfampTest_03-08-2016_180448.txtsimple_amp.png 
  12374   Thu Aug 4 17:29:17 2016 PrafulUpdateGeneralGuralp CableThe Guralp cable has been pulled and put
in the corner to the left of the water cooler:

 
 13932028_1768980090054533_2094690556_o.jpg 
  12380   Fri Aug 5 16:25:08 2016 PrafulUpdateElectronicsMic AmplifierI took the spectrum of an EM172 connected
to my amplifier inside and outside a large
box filled with foam layers:
 mic_box.pngspectra.png 
ELOG V3.1.3-