Entry  Wed Aug 5 16:33:50 2009, steve, Configuration, PSL, new PSL output iris psliris.png
I installed an improvised version of PSL output beam iris at the output periscope last week.
Entry  Wed Aug 5 15:57:05 2009, Alberto, Configuration, Computers, PMC MEDM screen changed 
I added a clock to the PMC medm screen.
I made a backup of the original file in the same directory and named it *.bk20090805
Entry  Wed Aug 5 11:49:49 2009, Stephanie, Update, General, Multiply Resonant EOM Update OSASetup.pngSMAPic.pngWithSMA.png
I have spent the past couple of days gathering optics and mounts so that I can observe the modulation of the EOM attached to the circuit I built using
the optical spectrum analyzer (OSA). A rough diagram of the planned layout is attached. 
I also built a short SMA cable so that the EOM did not have to be connected directly to the circuit box. The cable is shown attached to the EOM
    Reply  Wed Aug 5 15:18:12 2009, Stephanie, Update, General, Multiply Resonant EOM Update SMA.png


    
        
            Quote:
        
        
            
            I have spent the past couple of days gathering optics and mounts so that I can observe the modulation of the EOM
Entry  Wed Aug 5 07:33:04 2009, steve, DAQ, Computers, fb40m is down 
 
    Reply  Wed Aug 5 09:25:57 2009, Alberto, DAQ, Computers, fb40m is up 
FB40m up and running again after restarting the DAQ.
Entry  Tue Aug 4 17:51:25 2009, pete, Update, Computers, RCG work 
Koji, Peter
 
We put a simple pendulum into the MDP model, and everything communicates.  We're still having some kind of TP or daq problem, so we're still
Entry  Tue Aug 4 15:48:25 2009, Jenne, Update, Computers, mini boot fest 
Last night Rana noticed that the overflows on the ITM and ETM coils were a crazy huge number.  Today I rebooted c1dcuepics, c1iovme, c1sosvme, c1susvme1
and c1susvme2 (in that order).  Rob helped me burt restore losepics and iscepics, which needs to be done whenever you reboot the epics computer.
Unfortunately this didn't help the overflow problem at all.  I don't know what to do about that.
    Reply  Tue Aug 4 16:12:27 2009, rob, Update, Computers, mini boot fest 


    
        
            Quote:
        
        
            
            Last night Rana noticed that the overflows on the ITM and ETM coils were a crazy huge number.  Today I rebooted
Entry  Tue Aug 4 13:40:17 2009, pete, Update, Computers, RCG work - rate 
Koji, Pete
 
Yesterday we found that the channel C1:MDP-POS_EXC looked distorted and had what appeared to be doubled frequency componenets, in the dataviewer. 
Entry  Tue Aug 4 11:54:20 2009, Jenne, Update, IOO, MC_trans readout on LOCK_MC screen now normalized 
The MC_trans QPD Pitch and Yaw readout on the Lock_MC screen are now normalized by the trans_sum. I used the method described in my entry elog
1488.  
/caltech/target/c1iool0/ioo.db now includes:
Entry  Tue Aug 4 11:45:29 2009, Zach, Update, Cameras, GigE Phase Camera 
The camera wasn't working because the router has no built-in dhcp server.  We had to manually start the server after rebooting the computer.
Entry  Mon Aug 3 22:54:53 2009, Jenne, Koji, rana, Update, IOO, MC_trans is now better, but not best P8030099_copy.JPGP8030102_copy.JPG
Jenne, Koji, Rana
After fixing up the Mode Cleaner a bit more (fiddling more with the MC_align sliders to get the alignment before locking, making sure that it is
able to lock), we noticed that the MC Trans path could use some help. To align the MC, we put MC1 and MC3 back into the position where Rob left it on Thursday
Entry  Mon Aug 3 18:56:59 2009, Zach, Update, Cameras, GigE Phase Camera 
While aligning the optics, we tried to start up the CCD.  Although nothing should have changed since the last time I used it, the code claimed it
could not find the camera.  All the right leds are lit up.  The only indication that something is awry is that the yellow led on the camera isn't
blinking as it does when there is ethernet activity.  
Entry  Mon Aug 3 14:47:53 2009, Jenne, Update, IOO, MC locks again 
The mode cleaner seems to be locking again.  I've manually unlocked it a few times in the past 20min, and most of the time it catches lock again
(maybe about 80% of the time).  Other times, it starts to lock in a bad mode, and can't fix itself, so I unlock it, and let it restart and it usually
does fine the second time around. 
Entry  Mon Aug 3 14:15:50 2009, Jenne, Update, IOO, WFS recentered 
I am (was) able to get the mode cleaner mostly locked, but because WFS2 wasn't centered, the MC would drift, then lose lock.  I recentered both
the WFS (after unlocking the MC and the MZ), and am now about to commence relocking both of those.
 
Entry  Mon Aug 3 13:47:42 2009, pete, Update, Computers, RCG work 
Alex has firewalled megatron.  We have started a framebuilder there and added testpoints.  Now it is possible to take transfer functions with
the shared memory MDC+MDP sandbox system.  I have also copied filters into MDC (the controller) and made a really ugly medm master screen for the
system, which I will show to no one.
Entry  Mon Aug 3 01:08:20 2009, Alberto, Update, PSL, MC unlocked 
Friday afternoon the mode cleaner got unlocked. Then some adjustment of the MC1 bias sliders locked it again. The driftmon showed the excursion for pitch
and yaw of MC1 becasue it wasn't updated after the change.
Tonight Rana found the MC unlocked and simply touched the sliders to bring the OSEMs back to the driftmon values.
    Reply  Mon Aug 3 12:57:09 2009, Alberto, Update, PSL, MC unlocked 


    
        
            Quote:
        
        
            
            Friday afternoon the mode cleaner got unlocked. Then some adjustment of the MC1 bias sliders locked it again. The driftmon
Entry  Fri Jul 31 11:04:42 2009, Stephanie, Update, General, Multiply Resonant EOM Update BoxPic.pngBoxPic2.png
I put the flying-component circuit in a box; a photo is attached. I also measured the impedance; it looks exactly the same as it looked before I put
the circuit in the box.
Entry  Fri Jul 31 09:52:38 2009, Stephanie, Update, General, Multiply Resonant EOM Update BuiltCkt2_Simplified_EOM.pngImpedanceAG4395A_with10pF.pngBuiltCkt2_Simplified_EOM_R.pngImpedanceAG4395A_withEOM.png
I was able to make an impedance measurement of the flying-component circuit using Koji's method
for impedance measurement. I first measured the impedance of the circuit with a 10 pF capacitor in the place of the EOM (as shown in the circuit diagram).
This impedance plot is attached. I then added resistance to adjust the impedance slightly, attached the circuit to a New Focus KTP 4064 EOM, and took another
Entry  Wed Feb 18 21:10:21 2009, rana, Update, IOO, MC Drumhead mode lost again 
In early December, Caryn and I noticed that the MC Drumhead mode was visible at the Qmon point of
the MC demod board using a spectrum analyzer and no external excitation of the MC mirrors. We then
started tracking the MC Drumhead modes.
    Reply  Thu Jul 30 21:26:16 2009, rana, Update, IOO, MC Drumhead mode mc2drum.png
I used COMSOL 3.5a to do a FEA of one of the MC flat mirrors. Should be close to the same for all the mirrors.

The model is very simple- it includes just the cylindrical shape (no magnets, curvature, or coating or bevels).
Entry  Wed Jul 29 12:00:49 2009, Stephanie, Update, General, Multiply Resonant EOM Update ImpedanceTestingPhysicalSetup.pngImpResponses.pngImpedanceTestingSetup.pngImpedanceTestingCktDiagram.png1nF.png
For the past couple of days I have been trying to understand and perform Koji's method for impedance
measurement using the Agilent 4395A Network Analyzer (without the impedance testing kit). I have made some headway, but I don't completely understand
what's going on; here's what I've done so far.
    Reply  Thu Jul 30 19:55:23 2009, Koji, Update, General, Multiply Resonant EOM Update imepedance.pngimpedance_meas.jpg


    
        
            Quote:
        
        
            
            For the past couple of days I have been trying to understand and perform Koji's
Entry  Thu Jul 30 03:10:18 2009, rob, Update, IOO, MC tweaked further 
I tilted the periscope beam and aligned the MC.  Now the spot at the Faraday entrance is near the center of the aperture in up/down space. 
The arm powers are only going up to ~0.8, though.  Maybe we should try a little bit of left/right. 
I looked at the IP POS spot with a viewer card, and it looked round, so no obvious egregious clipping in the Faraday.  Someone might take
Entry  Wed Jul 29 13:15:35 2009, Clara, Update, PEM, Dents = Bad?? small_dent.pngbig_dent1.pngbig_dent2.png
I was in the lab last night accelerometerizing and noticed some dents on the tubes that stick out horizontally from the MC2 optical chamber (sorry, I
don't know what they're called or what they do). One of them is pretty big... I don't know if this is a problem, but it probably isn't a good thing. Photos
below:
    Reply  Wed Jul 29 19:46:04 2009, rana, alberto, Update, PEM, Dents = Bad?? 
[B]It looks like the MC2 chamber and/or stack has been jarred and shifted. Please be careful and use much less force and speed around the MC2 chamber.
[/B]
My guess is that the work with the accelerometers around there had made the MC2 angle and 
Entry  Wed Jul 29 19:41:58 2009, Chris, Configuration, General, EUCLID-setup configuration change EUCLID.png
David and I were thinking about changing the non-polarizing beam splitter in the EUCLID setup from 50/50 to 33/66 (ref picture).  It serves as a)
a pickoff to sample the input power and b) a splitter to send the returning beam to a photodetector 2 (it then hits a polarizer and half of this is lost. 
By changing the reflectivity to 66% then less (1/3 instead of 1/2) of the power coming into it would be "lost" at the ref photodetector 1, and
Entry  Fri Jul 24 11:04:11 2009, Alberto, Configuration, Computers, elog restarted 
This morning I found the elog down. I restarted it using the procedure in the wiki.
    Reply  Wed Jul 29 19:31:17 2009, rana, Configuration, Computers, elog restarted 
Just now found it dead. Restarted it. Is our elog backed up in the daily backups?
Entry  Wed Jul 29 14:56:44 2009, Jenne, Update, PEM, MiniEarthquakes due to construction 
The construction people next door seem to be getting pretty excited about pounding things lately.  At my desk the floor was shaking like a mini-earthquake,
and all of the accelerometers were pretty much railed. Clara has the Guralp box out right now, so the Guralp is unplugged, but the Ranger didn't seem to
be railed.
Entry  Wed Jul 29 14:22:33 2009, Zach, Update, Cameras, GigE Phase Camera 
This week, Joe and I have been setting up the laser and optics.  The mephisto laser is emitting a very ugly beam that we can hopefully remedy using
an iris and a lens.  After scanning the beam width at a few different distances from the laser, I am currently trying to determine the appropriate
lenses to use.
Entry  Wed Jul 29 12:14:40 2009, pete, Update, Computers, RCG work TF090729_1.pngTF090729_1.png
Koji, Pete 
Yesterday, Jay brought over the IO box for megatron, and got it working.  We plan to firewall megatron this afternoon, with the help of Jay
and Alex, so we can set up GDS there and play without worrying about breaking things.  In the meantime, we went to Wilson House to get some breakout
Entry  Wed Jul 29 11:58:57 2009, Alberto, Update, PSL, MC not locking 
This morning I found the Mode Cleaner unlocked.
I check the sliders for the mirrors bias and they have not changed. Also the OSEMs readbacks show no change in the optics positions.
I don't understand what's wrong because in the previous days, in this state of alignmanet, it could lock.
Entry  Wed Jul 29 11:15:06 2009, steve, Bureaucracy, SAFETY, Kevin receives safety training 
Kevin Vigue, our high school summer student went through the 40m specific safety traning yesterday.
Entry  Tue Jul 28 18:32:21 2009, Koji, Update, CDS, RCG work 
Peter and Koji,

We are constructing a setup for the new 40m CDS using Realtime Code Generator (RCG).
Entry  Tue Jul 28 16:03:14 2009, Clara, Update, PEM, Guralp Seismometer cable pin diagram guralp_pin_diagram.png
I mapped out the corresponding pins on both ends of the Guralp seismometer cable. Here is the diagram:
Entry  Mon Jul 27 19:55:19 2009, Koji, HowTo, IOO, Lens selection: plano-convex? or bi-convex? 
Q. When should we use plano-convex lenses, and when should we use bi-convex?
As I had the same question from Jenne and Dmass in a month,
I just like to introduce a good summary about it.
Entry  Mon Jul 27 17:48:44 2009, Jenne, Update, oplevs, ETMY oplev is still down for the count 
ETMY oplev is still out of order.  Hopefully I'll get it under control by tomorrow. 
Entry  Mon Jul 27 14:43:34 2009, Chris, Update, , Photodetectors 
I found two ThorLabs PDA55 Si photodetectors that says detect visible light from DC to 10MHz that I'm going to use from now on.  I don't know how
low of a frequency they will actually be good to.
Entry  Mon Jul 27 14:12:14 2009, rana, Summary, SUS, TM Coil Noise Spectra Coils.pdf
Rob noticed that the ITMY DAC channels were saturating occassionally. Looking at the spectrum we can see why.
With an RMS of 10000 cts, the peak excursions sometimes cause saturations.
Entry  Fri Jul 24 21:02:46 2009, Alberto, Update, PSL, Aligning the beam to the Faraday 
This afternoon I kept working on the alignment of the beam so that it matches at the same the PSL periscope, the Mode Cleaner and the Faraday isolator
at the input of the IFO.
The camera looking at the Farady showed a beam quite low from the center of the Faraday's entrance. I wanted to move it up.
    Reply  Sat Jul 25 16:04:32 2009, rob, Update, PSL, Aligning the beam to the Faraday 


    
        
            Quote:
        
        
            
       Reply  Sat Jul 25 19:04:01 2009, Koji, Update, PSL, Aligning the beam to the Faraday MC2_Cam.jpg


    
        
            Quote:
        
        
            
            
            
    
          Reply  Sun Jul 26 13:19:54 2009, rana, Update, PSL, Aligning the mode cleaner Untitled.png
I set the MC back to its good alignment (June 21st) using this procedure. The trend of the
OSEM values over the last 40 days and 40 nights is attached.
Then I aligned the periscope to that beam. This took some serious periscope knob action. Without WFS, the transmission went to 2.7 V and the reflection
             Reply  Sun Jul 26 16:05:17 2009, Alberto, Update, PSL, Aligning the mode cleaner 


    
        
            Quote:
        
        
            
            I set the MC back to its good alignment (June 21st) using this
             Reply  Mon Jul 27 09:34:07 2009, steve, Summary, IOO, Aligning the mode cleaner 20dtrend.jpg


    
        
            Quote:
        
        
            
            I set the MC back to its good alignment (June 21st) using this
Entry  Fri Jul 24 17:47:52 2009, Stephanie, Update, General, Multiply Resonant EOM Update BuiltCkt2_Picture_Simplified.pngBuiltCkt2_Simplified.pngSimplified.png
After speaking with Rana and realizing that it would be better to use smaller inductances in the flying-component circuit (and after a lot of tinkering
with the original), I rebuilt the circuit, removing all of the resistors (to simplify it) and making the necessary inductance and capacitance changes.
A picture of the circuit is attached, as is a circuit diagram.
    Reply  Sat Jul 25 13:49:28 2009, Koji, Update, General, Multiply Resonant EOM Update 


    
        
            Quote:
        
        
            
            After speaking with Rana and realizing that it would be better to use smaller inductances in the flying-component circuit
Entry  Wed Jul 22 16:15:52 2009, Chris Zimmerman, Update, General, Week 5/6 Update Beam_Scan.jpgLong_Range_Michelson_Setup_1_-_Actual.pngNSD_Displacement.png
The last week I've started setting up the HeNe laser on the PSL table and doing some basic measurements (Beam waist, etc) with the beam scan, shown on
the graph.  Today I moved a few steering mirrors that steve showed me from at table on the NW corner to the PSL table.  The goal setup is shown
below, based on the UCSD setup.  Also, I found something that confused me in the EUCLID setup, a  pair of quarter wave plates in the arm of their
    Reply  Sat Jul 25 13:34:58 2009, Koji, Update, General, Week 5/6 Update 


    
        
            Quote:
        
        
            
            The last week I've started setting up the HeNe laser on the PSL table and doing some basic measurements (Beam waist,
Entry  Fri Jul 24 17:20:48 2009, Jenne, Update, oplevs, ETMY oplev is iffy 
ETMY oplev is currently a work in progress.  The HeNe beam is hitting the photodiode, but the spot size there is pretty much the size of the entire
QPD.  Thus, the ETMY oplev isn't really useful right now.  I'm re-figuring things out (note to self: close to the laser, you have to use Gaussian
optics...regular ray tracing doesn't really work), and hopefully will have the oplev back under control by the time Alberto is finished realigning the
Entry  Thu Jul 23 20:30:23 2009, Alberto, Update, PSL, Beam aligned to the Farady 
After yesterday's changes in the MC cavity state today it was necessary to optimize the alignment to the Faraday.
The way I did it was by tuning the PSL periscope in pitch and yaw trying to maximize TRX with the arm locked. After a small change in either one
of the two directions I first maximized the MC transmitted power and then I ran the alignment script for the X arm.
Entry  Thu Jul 23 10:05:38 2009, Alberto, Update, PSL, Summary of the latest adventures with the alignment of the mode cleaner 







Entry  Thu Jul 23 07:34:45 2009, Aidan, Update, CDS, Added C2 MEDM screens to 40m SVN. 
 
See Adhikari eLOG entry: http://nodus.ligo.caltech.edu:8080/AdhikariLab/194
Entry  Wed Jul 22 20:11:26 2009, pete, Update, Computers, RCG front end 
I compiled and ran a simple (i.e. empty) front end controller on scipe12 at wilson house.  I hooked a signal into the ADC and watched it in the
auto-generated medm screens.  
There were a couple of gotchas:
Entry  Wed Jul 22 18:04:14 2009, rob, Omnistructure, Computers, weird noise coming from Gigabit switch 
in the rack next to the printer.  It sounds like a fan is hitting something.
Entry  Wed Jul 22 14:44:57 2009, Zach, Update, Cameras, GigE Phase Camera 
This past week, I have mostly been debugging my software.  I have tried to use the fluorescent lights to test the camera, but I can't tell for sure
if my code is finding the correct amplitude and phase or not.  I am currently using Mathematica to double check my calculations in solving for the
phase and amplitude.
Entry  Tue Jul 21 18:46:47 2009, steve, Configuration, Computers, computers are down 
All suspentions are kicked up. Sus dampings and  oplev servos turned off.
c1iscey and c1lsc are down. c1asc and c1iovme are up-down
    Reply  Wed Jul 22 01:57:19 2009, Alberto, Configuration, Computers, computers are down 


    
        
            Quote:
        
        
            
            All suspentions are kicked up. Sus dampings and  oplev servos turned off.
       Reply  Wed Jul 22 09:04:10 2009, Alberto, Configuration, Computers, computers are down 


    
        
            Quote:
        
        
            
            
            
  
          Reply  Wed Jul 22 11:14:11 2009, Alberto, Configuration, Computers, computers are down 


    
        
            Quote:
        
        
            
            
            
  
             Reply  Wed Jul 22 11:18:49 2009, rob, Configuration, Computers, sticky sliders 


    
        
            Quote:
        
        
            
            
            
  
Entry  Wed Jul 22 11:08:36 2009, Stephanie, Update, General, Multiply Resonant EOM Update BuiltCkt_Picture.pngBuiltCkt2_Final.png1stSegment.png2ndSegment_ExtraL.pngComplete_ExtraL.png
I have built a version of the circuit with flying components; the completed circuit is shown in the attached picture. I built the circuit in segments
and measured the transfer function after each segment to see whether it matched the LTSpice simulation after each step. The segments are shown in the circuit
diagram.
Entry  Wed Jul 22 10:49:40 2009, Alberto, Update, PSL, MC Alignment Trend 2009-07-21_MC-align-trend.pdf2009-07-22_mc-align-trend.pdf
Trying to track the MC positions back for a few days, it seems that the data hasn't been recorded properly for a while. Something happened yesterday
after my boot fest and then the record got restored. Attached here are the readbacks showing the event for MC1.
Is anything wrong with the data record?
Entry  Tue Jul 21 15:32:47 2009, Jenne, Update, IOO, MC_L flatlined 
[Clara, Jenne]
While Clara was working on her Wiener filtering and optimizing the locations of the accelerometers, she discovered that MC_L and MC_L_256 are totally
flatlined.  I looked at them, and it looks like they've been dead since ~9:30pm-ish on Sunday night.  Bootfest-type activities shall commence
    Reply  Tue Jul 21 17:52:12 2009, Jenne, Update, IOO, MC_L flatlined 


    
        
            Quote:
        
        
            
            [Clara, Jenne]
Entry  Tue Jul 21 17:01:18 2009, pete, DAQ, DAQ, temp channel PEM-PETER_FE 
I added a temporary channel, to input 9 on the PEM ADCU.    Beware the 30, 31, and 32 inputs.  I tried 32 and it only gave noise.
 
 
Entry  Tue Jul 21 13:55:08 2009, Clara, Update, PEM, Guralp Box Success! 
There managed to be just enough 100 kOhm resistors to stuff all the "2" channels (VERT2, N/S2, E/W2) with the fancy low-noise resistors. The
first six channels (VERT 1/2, NS 1/2, EW 1/2) are now completely done with the thin-film resistors, taking into account the changes that were made on the
circuit diagram. I also replaced the C8 capacitor with the fancy Garrett ones and added capacitors on top of R4 and R13 (after painstakingly making sure
ELOG V3.1.3-