  12297   Wed Jul 13 00:38:25 2016 JohannesUpdateGeneralVent progress - ETMY attempted repositioning[Lydia, Johannes]

We attempted to move the ETMY suspension
near the access port in preparation for the
  
  12298   Wed Jul 13 03:16:47 2016 KojiUpdateGeneralITMX dustMulticolor flash light:

- It seems that the usb port charging
doesn't work.
  
  12299   Wed Jul 13 15:35:56 2016 LydiaUpdateGeneralVent Progress - ETMY repositioned and removed[Lydia, Johannes]

Took
photos to document the original OSEM orientation
  
  12300   Wed Jul 13 21:13:51 2016 KojiUpdateGeneralETMX guide rod gluing / ETMY Magnet gluing[Eric, Koji]


ETMX: The Al guide
rod has been glued on the mirror.
ETMY:
 13x 
  12301   Thu Jul 14 01:00:33 2016 KojiUpdateGeneralETMX ruby guided gluingToday I took the picture of the glued ruby
stand-off. The groove has not been invaded
by the epoxy!
 ruby.jpg 
  12302   Thu Jul 14 22:29:57 2016 ericq UpdateGeneralETMX guide rod gluing / ETMY Magnet gluingThe pickle puckers came off ETMY cleanly  ETMY now rests   
  12305   Fri Jul 15 16:23:51 2016 ericq UpdateGeneralGluing setbacks[ericq, Lydia]

Here is a picture of the ETMX guide
rod post-gluing. There is unfortunately a
 IMG_2768.JPGIMG_2771.JPG 
  12306   Fri Jul 15 17:44:37 2016 AakashSummaryGeneralAcromag Setup | SURF2016Aidan has described the physical connections
and initial setup here :  https://nodus.ligo.caltech.edu:30889/ATFWiki/doku.php?id=main:resources:computing:acromag#recovering_from_a_terminal_power_communication_outage 
.
  
  12308   Mon Jul 18 05:05:05 2016 AakashUpdateGeneralHeater for Seismometer Enclosure | SURF 2016I took off the silicon rubber heaters which
were used by a SURF last year for heating
the enclosure. The heater data sheet has
 HEATERS.jpegHEATERS.jpeg 
  12310   Tue Jul 19 13:21:42 2016 JohannesUpdateGeneralVent progress - ETMY attempted repositioning[Lydia, Johannes]

We moved ITMY from its original
position to a place near the access point.
  
  12312   Tue Jul 19 15:30:08 2016 SteveUpdateGeneralHEPA dryer and dustI set up a simple HEPA filter dryer to
dry your clean room garment before 
you can put it away into your storage box.
 HEPAdryer.jpg 
  12313   Tue Jul 19 16:39:29 2016 LydiaUpdateGeneralETMX magnet gluing/guiderod excess glue removed[ericq, Lydia]

The epoxy arrived. Eric managed
to remove the excess glue below the
 P7190201.JPGP7190203.JPG 
  12317   Thu Jul 21 05:22:26 2016 AakashUpdateGeneralTemperature measurements across the enclosure | SURF 2016I have measured the transfer function of
temperature fluctuations inside the enclosure
to that of the temperature fluctuations outside.
 script21jul2016.mfig1.pdffig2.pdffig3.pdf 
  12322   Thu Jul 21 17:01:59 2016 ericqUpdateGeneralETMX magnet gluing/guiderod excess glue removedOne step forward, two steps back...

While attempting to suspend ETMX,
I broke off a side magnet 
  
  12323   Thu Jul 21 21:38:44 2016 AakashUpdateGeneralTemperature measurements across the enclosure | SURF 2016I have made the changes as suggested by
Gautam.
  
  12326   Fri Jul 22 05:20:26 2016 AakashUpdateGeneralTemperature measurements across the enclosure | SURF 2016Please find the new attached plots and
the new script.
 coherence.pdftransferfunc.pdftransferfuncdB.pdfscript22jul2016.m 
  12327   Fri Jul 22 23:03:23 2016 gautamUpdateGeneralETMX suspension - progress[ericq, gautam]

Summary:

Today, we attempted to progress
 IMG_2828.JPGIMG_2826.JPGIMG_2821.JPGIMG_2822.JPGIMG_2823.JPG 
  12328   Sun Jul 24 03:43:56 2016 ericqUpdateGeneralMagnet positioningWhen Koji and I were gluing magnets to
ETMY, we decided to position the side magnet
based on the empirically observed offsets
  
  12331   Mon Jul 25 13:01:49 2016 ericqUpdateGeneralETMX suspension - progress(Full resolution versions of the photos
in this ELOG are on picasa)

The OSEM gender changers were not
 IMG_2829.JPGIMG_2830.JPGIMG_2831.JPGIMG_2832.JPGIMG_2833.JPG 
  12332   Mon Jul 25 13:47:19 2016 ranaUpdateGeneralETMX suspension - progressUgh.    
  12335   Mon Jul 25 20:37:46 2016 gautamUpdateGeneralETMX suspension - Side OSEM test[Lydia, gautam]

Summary: We
did some preliminary tests to check if at
 osem_test_2016_07_25.png 
  12340   Tue Jul 26 18:07:57 2016 gautamUpdateGeneralETMX suspension - Further OSEM TestsToday, we did the following:


Once again, inserted all
four face OSEMs till the sensor voltage readouts
 OSEM_spectra.pdf 
  12345   Thu Jul 28 03:22:28 2016 ericqUpdateGeneralETMX magnets re-reglued[gautam, ericq]

Brief summary, some pictures and
such follow in the daytime. 
  
  12347   Thu Jul 28 13:49:44 2016 gautamUpdateGeneralETMX magnets re-reglued


 ETMX_sideMagnet.JPGETMX_sideMagnet_zoomed.JPG 
  12348   Thu Jul 28 16:43:01 2016 LydiaUpdateGeneralETMX aluminium standoff groove condition 

I took some pictures with the digital
microscope of the aluminum standoffs
 wire_damage_4.jpgwire_damage_zoom.jpgno_wire.jpgcomparison_2.jpg 
  12349   Thu Jul 28 17:48:17 2016 gautamUpdateGeneralETMY LR magnet broke offWhile ETMX magnets were curing, I wanted
to try and suspend ETMY in the endchamber,
put in the OSEMS and see if the magnets aligned
  
  12350   Thu Jul 28 22:43:03 2016 ranaUpdateGeneralETMY UL magnet broke offI'd recommend replacing the wire and
grinding down the clamp to prevent cutting
the wire. Since we have almost never replaced
  
  12351   Fri Jul 29 03:32:30 2016 ericqUpdateGeneralETMX suspended once more[gautam, ericq]

Tonight's progress on ETMX:


All pickle pickers removed
  
  12354   Fri Jul 29 13:17:34 2016 KojiUpdateGeneralOvenWhile the air bake oven situation is being
improved, how about to buy a cheepo toaster
oven at Target, BestBuy, or anywhere?
  
  12358   Sun Jul 31 17:28:38 2016 ranaOmnistructureGeneralupcleanI cleaned up the south Electronics bench
today.

The other two, as well as several
  
  12360   Mon Aug 1 18:50:29 2016 AakashUpdateGeneralAcromag Setup | SURF2016There were many unknown and unsolved problems
with using modbusApp for linux-arm architecture.
So I tried to install the necessary files
 7x 
  12364   Wed Aug 3 10:52:03 2016 SteveUpdateGeneralETMY soaking dishETMY UL epoxy soaking dish. All teflon
in glass.

 
 SD1.jpgSD2.jpgSD3.jpg 
  12366   Wed Aug 3 15:35:19 2016 AakashUpdateGeneralAcromag Setup | SURF2016Lydia helped me to troubleshoot the Accromag
connection problems which I was facing previously. 
If power goes off/turned off manually, the
  
  12368   Wed Aug 3 16:34:59 2016 LydiaUpdateGeneralAcromag Setup | SURF2016Actually, if the power goes off and back
on, the ethernet connection comes back online
after about 5 seconds, or faster if it is
  
  12374   Thu Aug 4 17:29:17 2016 PrafulUpdateGeneralGuralp CableThe Guralp cable has been pulled and put
in the corner to the left of the water cooler:

 
 13932028_1768980090054533_2094690556_o.jpg 
  12376   Thu Aug 4 17:57:09 2016 KojiConfigurationGeneralDon't restart apache2 - nodus /etc/apache2/sites-available/* accidentally deleted Late coming elog about the deletion
of the apahce config files


Thu Aug 4 8:50ish
  
  12387   Tue Aug 9 15:50:30 2016 PrafulUpdateGeneralGuralp CableThe Guralp cable has been reconnected and
powered after having the connector changed
out.
  
  12393   Wed Aug 10 17:20:16 2016 LydiaUpdateGeneralSeismometer channel names changed[ericq, Lydia]

We
changed the seismometer channel names from,
  
  12394   Wed Aug 10 17:30:26 2016 Max IsiUpdateGeneralSummary pages statusSummary pages are currently empty due to a
problem with the code responsible for locating
frame files in the cluster. This should be
  
  12399   Thu Aug 11 11:09:52 2016 Max IsiUpdateGeneralSummary pages statusThis problem has been fixed. 

> Summary pages are currently empty due to
  
  12432   Tue Aug 23 09:50:17 2016 Max IsiUpdateGeneralSummary pages down due to cluster maintenance Summary pages down today due to schedulted
LDAS cluster maintenance. The pages will
be back automatically once the servers are
  
  12440   Thu Aug 25 08:19:25 2016 Max IsiUpdateGeneralSummary pages down due to cluster maintenance The system is back from maintenance and
the pages for last couple of days will be
filled retroactively by the end of the week.
  
  12477   Wed Sep 7 18:00:47 2016 LydiaUpdateGeneralAcromag Progress[Teng, Lydia]

We
would like to establish a system for setting
  
  12481   Sat Sep 10 14:26:01 2016 ranaUpdateGeneralPRM SRM alignmentFor the PRM, I aligned it until the arm
flashes were maximized and the REFL camera
showed a centered spot with dips happening
 Osamu.JPG 
  12482   Mon Sep 12 17:15:22 2016 JohannesUpdateGeneralPRM SRM alignment[Gautam, Steve, Johannes]

We put on the remaining heavy doors
on the chambers (ITMY, ITMX,ETMX, in this
 IMG_3273.JPGIMG_3275.JPG 
  12485   Mon Sep 12 20:19:25 2016 LydiaUpdateGeneralMC REFL beam splitter not replacedThe
beam splitter that directs light into the
MC REFL photodiode has not been replaced;
  
  12489   Tue Sep 13 19:02:56 2016 TengUpdateGeneralITMX sensor[Lydia,Teng]

Something strange happened to the
ITMX osem reading around 4.pm. PDT as shown
 47.png34.png 
  12491   Wed Sep 14 09:33:54 2016 SteveUpdateGeneralITMX magnets are stuckedI believe that the UR and LR magnets are
stuck. There was no earth quake at 16:18
yesterday. Something had to kick it into
 ITMXmagStuck.png 
  12493   Wed Sep 14 19:41:23 2016 JohannesUpdateGeneralPSL back to high powerToday's summary:


Replaced mirror in MC REFL
path with R=10% BS and aligned beam on PD
  
  12494   Wed Sep 14 20:05:32 2016 LydiaUpdateGeneralITMX magnets are stuckedWhen I restarted c1susaux yesterday, I
didn't know that I needed to disable
the coil outputs first. So when it came back
  