40m QIL Cryo_Lab CTN SUS_Lab CAML OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 136 of 354  Not logged in ELOG logo
IDup Date Author Type Category Subject Text Attachments
  6796   Tue Jun 12 00:15:51 2012 JenneUpdateComputersrtcds: command not foundWe can't compile any changes to the LSC
or the GCV models since Jamie's new script
/ program isn't found.  I don't know
  
  6797   Tue Jun 12 01:03:18 2012 JenneUpdateComputersmini boot festAs usual, we noticed the frame builder
wasn't connecting happily with the rest of
the computers just as we were about to lock
 stock-vector-wine-icon-on-computer-keyboard-original-illustration-58731781.jpg 
  6798   Tue Jun 12 01:58:33 2012 yutaUpdateGreen Lockingaligned Y arm to Y end green[Jenne, Yuta]

We aligned Y arm to the Y end green
  
  6799   Tue Jun 12 02:07:42 2012 JenneUpdateSUSPRM oplevs left offYuta claims he fixed the PRM oplev by centering
it the other day, but no one has left it
on and watched it for a long while, to make
  
  6800   Tue Jun 12 02:09:43 2012 JenneUpdateComputersmini boot fest

    

       
            
  
  6801   Tue Jun 12 11:25:05 2012 JamieUpdateComputersrtcds: command not found

    

       
            
  
  6802   Tue Jun 12 11:54:50 2012 JenneUpdateGreen Lockingc1gcv recompiledYuta added channels so we can get the Q
phase of all the beat PDs to the c1gcv model. 
I showed him how to recompile/install/start.
 c1gcv20120612.png 
  6803   Tue Jun 12 13:49:32 2012 JamieConfigurationComputer Scripts / ProgramstconvertA nicer, better maintained version of tconvert
is now supplied by the lalapps package. 
It's called lalapps_tconvert. 
  
  6804   Tue Jun 12 16:33:32 2012 steveUpdateSUSPRM oplevs servo ON for confirmation


   
        
            
  
  6805   Tue Jun 12 17:04:55 2012 steveUpdateSUSPRM oplevs servo is still bad


   
        
            
 PRMolvstillosc.png 
  6806   Tue Jun 12 17:29:28 2012 DenUpdateCDSdq channelsAll PEM and IOO DQ channels disappeared.
These channels were commented in C1???.ini
files though I've uncommented them a few
  
  6807   Tue Jun 12 17:46:09 2012 JenneUpdateComputersrtcds: command found

    

       
            
  
  6808   Tue Jun 12 20:35:46 2012 yutaUpdateGreen Lockingc1gcv recompiled[Jamie, Yuta]

We recompiled c1gcv because the order
 c1gcv20120612-2.png 
  6809   Tue Jun 12 23:18:18 2012 yutaUpdateGreen LockingI-Q signals for the beat[Mengyao, Yuta]

 FINEIQplot20120612.pngCOARSEIQplot20120612.pngbeatysetup20120612.png 
  6810   Wed Jun 13 02:11:59 2012 yutaUpdateGreen Lockingmy first modescan (sort of)I stabilized Y arm length by using only
I phase coarse signal from the beat(C1:ALS-BEATY_COARSE_I_ERR).
I sweeped the arm length by injecting
 modescan20120612_1.png 
  6811   Wed Jun 13 02:24:02 2012 ranaUpdateGreen Lockingmy first modescan (sort of) That sounds goofy.
With the delay line technique,
you can get a linear signal over 50 MHz with
  
  6812   Wed Jun 13 03:03:38 2012 yutaUpdateGreen Lockingmy first modescan (sort of)Linear range df of the delay line technique
is about df ~ c/(2D). So, the linear range
for the fine signal(delay line length D=30m)
  
  6813   Wed Jun 13 11:10:56 2012 ranaUpdateGreen Lockingmy first modescan (sort of)You can easily calculate whether or not
the coarse readout will work by thinking
about the scan resolution you need given
  
  6814   Wed Jun 13 11:19:05 2012 steveUpdateSUSIDC receptacles clampedThe MC_ IDC 64 pin cables from sat. amplifiers
to junction-interface-board towards 
whitening - dewhitening at the back of rack
 IMG_1341.JPG 
  6815   Wed Jun 13 17:39:13 2012 yutaUpdateGreen Lockingcalibrating the beatbox[Jenne, Yuta]

We put 0 dBm sine wave to the RF input
 ALS-BEATY_COARSE_I_IN1_DQ.pngALS-BEATY_COARSE_Q_IN1_DQ.pngALS-BEATY_FINE_I_IN1_DQ.pngALS-BEATY_FINE_Q_IN1_DQ.png 
  6816   Thu Jun 14 01:36:34 2012 yutaUpdateGreen Lockingcan't scan Y arm for 1FSR[Jenne, Koji, Yuta]

We tried to scan of the Y arm but
 BEATY_COARSE_LoopOnOff.png 
  6817   Thu Jun 14 04:53:39 2012 yutaSummaryGreen Lockingdesigning ALS loop for mode scan[[Requirement]]
 Arm cavity FWHM for IR is 
 ALSloop.pngALSopenloop.pngyarmlength.png 
  6818   Thu Jun 14 21:37:37 2012 yutaUpdateGreen Lockingsucceeded in 1FSR mode scan[Jenne, Yuta]

We couldn't scan the Y arm for 1FSR
 YarmScan20120614.png 
  6819   Fri Jun 15 00:50:54 2012 yutaUpdateGreen Lockingscanned Y arm for 5FSRI scanned Y arm for 5FSR (below).
I could done this after I put a whitening
filter.
 YarmScan20120614_2.png 
  6820   Fri Jun 15 01:53:05 2012 KojiUpdateGreen Lockingscanned Y arm for 5FSRInteresting.
It seems for me that there is a dependence
of the noisiness as the beat frequency is
  
  6821   Fri Jun 15 13:33:39 2012 yutaUpdateGreen LockingADC noise contribution to ALSADC noise is not a limiting noise source
in a current ALS setup.
 YarmALSnoise20120615.png 
  6822   Sat Jun 16 01:03:21 2012 yutaUpdateGreen Lockingused longer delay line for mode scan[Mengyao, Yuta]

Last night, I used 1.5 m delay line
 YarmScan20120615.png 
  6823   Sat Jun 16 12:03:41 2012 ZachUpdateGreen Lockingscanned Y arm for 5FSRIs that time stamp really correct?
I wanted to look at the signal closely to
see if I could get any feeling for why it
  
  6824   Sat Jun 16 13:01:17 2012 yutaUpdateGreen Lockingscanned Y arm for 5FSR

    

       
            
 YarmScanDV.png 
  6825   Sat Jun 16 18:17:00 2012 yutaUpdateGreen LockingY arm length using 5FSR scanCalibrating error signal to beat
frequency;
  I injected 0 dBm RF sine wave
 ALS-BEATY_COARSE_I_IN1_DQ.pngCalibYarmScan20120614_2.png 
  6826   Sat Jun 16 18:51:44 2012 KojiUpdateGreen LockingY arm length using 5FSR scan

    

       
            
  
  6827   Sat Jun 16 19:32:11 2012 yutaUpdateGreen LockingY arm length using 5FSR scanI know!
But I think there's some error (~
10% ?) in calibrating the beatbox. In elog
  
  6828   Mon Jun 18 02:31:43 2012 yutaSummaryGreen Lockinganalysis of mode scan dataI analyzed mode scan data from last week.
Mode matching ratio for Y arm is 86.7
 coarse5FSRscan.pngfine1FSRscan.pngHOMRFSB.pngcoarse5FSRscanHOMRFSB.png 
  6829   Mon Jun 18 16:23:59 2012 JenneUpdateLockingLSC trigger updateThe LSC triggers for the individual filter
modules in a filter bank now works. 
This is handy so that boosts can come on
  
  6830   Mon Jun 18 17:28:03 2012 yutaSummaryComputersbugs in CDS_PARTS/simLinkParts/FcnFcn module in CDS_PARTS is used to include
a user defined function in a model.
We should be able to use this by entering
 model_sindegbug.pngdv_sindegbug.png 
  6831   Mon Jun 18 23:38:39 2012 JenneUpdateLSCAdded LSC channels to framesSince the .ini files get overwritten every
time a model is compiled now, we need to
put all channels we want saved to frames
  
  6832   Mon Jun 18 23:54:31 2012 yutaUpdateGreen Lockingphase tracker for ALS[Koji, Jenne, Yuta]

Summary:
 newIQLOCK.pngYarmScan20120618.pngfine8FSRscan.png 
  6833   Tue Jun 19 20:26:50 2012 JenneHowToLockingSummer PlanJenne and Yuta's
Summer Plan
  
  6834   Tue Jun 19 23:36:19 2012 yutaUpdateLSCcalibrated POY error signal[Jenne, Yuta]

We calibrated POY error signal(C1:LSC-POY11_I_ERR).
 LSCyarmTF_usingITMY.pngLSCyarm_HAover1plusG.pngPOYerrorcalibration.png 
  6835   Wed Jun 20 00:01:04 2012 JenneUpdateLSCcalibrated POY error signal[Yuta, Jenne]
We have measured the out of loop
residual motion of the Yarm while locked
 LSC_POY_11_I_ERR_calib_19June2012.pdfPOY_calib_19June2012_FiltBankSettings.png 
  6836   Wed Jun 20 00:02:16 2012 yutaUpdateGreen Lockingslower scan using phase tracking ALSFor those of you who want to see plots
from slower scan.
 YarmScan20120619.png 
  6837   Wed Jun 20 01:02:20 2012 JamieUpdateGreen LockingRF amp removed from X arm ALS setupI very badly forgot to log about this in
the crush of surfs.
I removed Koji's proto-beatbox RF
  
  6838   Wed Jun 20 16:37:11 2012 yutaUpdateLockingETMX 1064 trans camera[Jenne, Yuta]

We made ETMXT camera working.
  
  6839   Wed Jun 20 18:00:10 2012 ranaSummaryPSLsummaries Nice PSL summaries from LHO:
https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=3187
  
  6840   Wed Jun 20 18:09:23 2012 yutaUpdateLockingboth arms aligned, ITMX oplev centered[Jenne, Yuta]

We aligned FPMI. I also centered ITMX
 FPMIalignment2010620.png 
  6841   Wed Jun 20 18:43:57 2012 yutaUpdateLSCcalibrated POX error signal[Jenne, Yuta]

We did the same calibration for POX.
 LSCxarmTF_usingITMX.pngLSCxarm_HAover1plusG.pngPOXerrorcalibration.png 
  6842   Thu Jun 21 01:58:29 2012 JenneUpdateGreen LockingXgreen preparations[Yuta, Koji, Jenne]
Lots
of small things happened tonight, in preparation
  
  6843   Thu Jun 21 02:57:16 2012 JenneBureaucracyGeneral40m Action ItemsPRIORITY
ITEMS:
  
  6844   Thu Jun 21 09:01:18 2012 steveUpdateSTACISthe resurrection of STACIS -surfThere is a small wood cabinet under the
south end flow bench, labeled STACIS.
Unit is complete with extension cards
 IMG_1364.JPG 
  6845   Thu Jun 21 09:10:08 2012 steveUpdatePEMflow bench must be running all timesThe south end flow bench HEPA filter should
be run all times. You can turn it off for
a measurement or two but remember we are
  
ELOG V3.1.3-