  9052   Thu Aug 22 13:03:40 2013 JenneUpdateLSCDRMI Locked for 1+ minute!!!!!!

Quote:

  Very nice!!  I was wondering, shouldn't the driving matrix be such that MICH pushes on SRM as well?

 Hmmm, yes, that's a very good point.  I think you're right, and I'll give that a try today.

  9053   Thu Aug 22 13:20:54 2013 KojiUpdateLSCDRMI Locked for 1+ minute!!!!!!

Don't go for a hacky solution. We want to climb a staircase step by step.
Prepare an independent 110MHz demod ports.

Quote:

To-do:  Set up the AS OSA.  Also, perhaps temporarily borrow the 110 demod board from POP.  We were triggering on POP22 tonight, and that seemed to work okay. 

 

  9055   Thu Aug 22 21:16:47 2013 ManasaUpdateGreen LockingGTRY normalized

The Y arm green transmission has been measuring in counts all along. I modified the gain in the ALS-TRY filter module to normalise the transmission.

Transmission has been normalised with GTRY = 1 corresponding to 600 counts. 

  9056   Thu Aug 22 22:05:36 2013 ranaUpdateGreen LockingGTRY normalized

Meh. 600 counts is too weak.  You should fix the electronics so that the maximized green laser transmission gives more like ~10000 counts.

  9057   Fri Aug 23 01:52:34 2013 JenneUpdateSUSViolin filters moved to LSC, from SUS

[Rana, Jenne]

We were meditating a little bit on what may be the story behind the PRM violin filter situation.  We locked the PRMI, and turned on and off the violin filters.  We noticed, very bizarrely, that when the violin filters were ON, the servos would oscillate.  Weird.  Also, probably because the oscillation was causing us to hit the limit we have in the MICH servo, we rung up a 3rd harmonic of one of the violin modes, which was at 1955 Hz. 

We took a transfer function of the PRCL servo, saw that the UGF was 300 Hz, and lowered it to ~180 Hz.  After later investigations, that high-ish UGF probably wasn't a problem.  Anyhow, we then took MICH servo transfer functions, and saw some very weird stuff. 

At frequencies where we had violin filter notches, we were seeing peaks in the transfer function, which came close to touching, or crossed the 0dB line!  We suspect that this may have something to do with the balancing of the drives to the optics, since we have PRCL driving PRM, but MICH driving BS and PRM.  What we did was move the violin filter notches into the LSC model.  There were already SUS filter banks in the LSC model (right side of the LSC screen).  In preparation for the DRMI, I have put the BS violin notches into the BS, PRM and SRM filter banks, as well as the PRM and SRM filters into all 3 banks.  Right now for PRMI, I have the BS and PRM notches (as well as the Vio3 notch) turned on in both BS and PRM.  All of the violin-related filters are turned off in the LSC filter bank inside the SUS models.  When we did this, the servo oscillations no longer are excited when we turn on the notches, and when we take a new transfer function, there are no longer weird peaks at the notch frequencies.  More meditation needs to be done.

Also, for the violin3 filter, Rana noted that at 1955 Hz, after we confirmed that the REFL 55 phase was set correctly (and we're using REFL 55 I&Q for PRMI locking), the I-phase had a response of 0.36, while the Q-phase had a response of 0.20.  I should be able to think about these numbers, and decide if the vio3 is for the BS or the PRM violin mode.

 MICHloopNotches_23Aug2013.pdf

the above series of Bode plots shows the MICH Open Loop Gain as the REFL55 phase is adjusted (PURPLE, ORANGE) with the notches in the SUS and then (RED) as the notches are moved to the LSC and made the same for all optics.

In other news, I have the parts that Jamie ordered to make a new 110 demod board, so that's one of my daytime activities now, so we can have both POP110 and AS110.

  9058   Fri Aug 23 14:19:28 2013 ranaUpdateSUSViolin filters moved to LSC, from SUS

  Just to rephrase somewhat:

  • We balance the BS & PRM actuators in the LSC Output matrix so that there is no MICH signal going into REFL_I @ 100 Hz.
  • REFL Phase is adjusted by driving PRM and minimizing Q/I to within ~1 deg (Q/I ratio of ~2%)
  • The REFL_I sensing matrix element is ~50x bigger than REFL_Q (in W/m)
  • When we turn ON the violin mode notch in the BS SUS, it changes the MICH drive into a purely PRCL drive at that frequency !!!
  • So, putting notches into the SUS screens is bad since it imbalances the drives.
  9060   Sat Aug 24 00:11:07 2013 KojiUpdateLSCDRMI Locked with improved lock streatches

Friday night locking

Much more stable DRMI lock was achieved, partly thanks to the Friday-night quiet seismic,
and partly because of the improved servo gain and LF boosts


55MHz thru-put

I wanted to confirm the enhancement of the 110MHz signal at the AS port.

As the AS110 PD is placed in the CCD path, there is nothing visible with PRMI.
The Thorlabs PD was moved to the main AS path. Now the AS110 PD is receiving 50% of the power.
 

With PRMI 110MHz peak was -30dBm (As it was fluctuating, anything more precise number did not make sense)
When the DRMI was locked, the peak was enhanced to 0dBm.

The 2f signal comes from the beat between the sidebands.
Thus the amplitude of the intensity is proportional to the power of the sidebands (assuming the +1 and -1 order sidebands have the same amplitude)
-30dBm -> 0dBm means 31.6 times amplitude of the intensity. Therefore the amplitude transmission of the sidebands is 5.6 times more. (Is this true?)

According to the wiki, the AS port thru-put (i.e. power transmission) for the 55MHz sideband is 0.0026 and 0.43 for PRMI and DRMI respectively.
This corresponds to the amplitude difference of ~13. So we still have only half of the sidebands leaking out from the IFO. This could be attributed
to both the smaller PR gain and SR gain.


Locking setup

Same as the one Jenne used the other day. Later I engaged several additional triggers.
The following is the trigger setting I used

MICH: Delay 2 sec, FM1/FM2/FM3/FM6/FM7

PRCL: Delay 0.5 sec, FM2/FM3/FM6

SRCL: Delay 5 sec, FM1/FM2/FM3/FM6

SRCL FM1 was modified from +3dB to +6dB


Lock stability

Once lock is acquired, it lasts tens of minutes. (see the attached striptool chart.)
Even the lock is lost, it reacquires quickly.

The videos to show the lock acquisition and the in-lock stability are attached below.
The AS port beam is very round. It is not so shaky, but some yaw motion is visible.
The mode at the AS port is defined by the SRM, putting a QPD at the AS port would help to
stabilize the spot.


IFO state upon leaving

I left the 40m with the arms aligned, PRM and SRM slightly misaligned, and LSC setting is for the DRMI locking.


TO DO

- AS110I/Q for triggering

- PRCL/MICH/SRCL normalization

- We should resurrect the IFO config scripts.

- Remove BS->SRCL actuation coupling

- Handing off to 3f signals (preparation for the full lock)

- Improve ALS stability

- SRM ASC: AS QPD for SRM control


Lock Acquisition Video
UL (REFL) / UR (POP)
LL (AS) / LR (PRM Face)

 
In-lock video
UL (REFL) / UR (POP)
LL (AS) / LR (PRM Face)

 

Attachment 1: Screenshot-Untitled_Window.png
Screenshot-Untitled_Window.png
  9061   Sun Aug 25 06:07:11 2013 ranaUpdateLSCDRMI Locked with improved lock streatches

 We're ready for using the auto configure.

We can put our scripts for the MICH, PRMI, and DRMI into the IFO CONFIGURE screens for now and then it should be easy to get them into the Guardian once Jamie has the bugs worked out.

This screen can also be used to setup and start the dither alignment for each configuration (once we have one working for DRMI / SRM).

Also, now that the notches/bandstop filters for the violin modes have been move from the SUS into the LSC, we should fix the triggering to engage them a few seconds after the boosts.

  9063   Mon Aug 26 18:59:08 2013 MasayukiUpdateLSCLSCoffset script updated

I made scripts/LSC/LSCoffsets2.py which is the script to zero the dark offset of all the LSC PD.  The list of PDs is same as the list in scripts/LSC/LSCoffsets. New script average all outputs of PDs parallelly, so we can zero the offsets much faster.

You can define the averaging time, and you can choose the channel for getting the dark offset from INMON or OUT16. You should know that if you use OUT16 channel, the effect of the unwhite filter is not taken into account.

Example usage (at scripts/LSC):

   ./LSCoffsets2.py -d 20 --out16

you can find the help by calling this script with option -h or --help

  9064   Mon Aug 26 19:13:38 2013 KojiUpdateLSCLSCoffset script updated

What do you mean???

What is the effect of the anti-whitening filter?

Quote:

You should know that if you use OUT16 channel, the effect of the unwhite filter is not taken into account.

 

  9065   Mon Aug 26 19:31:22 2013 manasaUpdateSUSPRM, ITMY watch dogs

PRM and ITMY were found with their watchdogs shutdown this afternoon (cause unknown). I re-engaged them.

  9066   Mon Aug 26 19:54:15 2013 manasaUpdateCDSc1als model modified

I had made changes to the c1als model a couple of weeks ago. I had removed all the beat_coarse channels that had existed from pre-phase tracker era.

Also, I forgot to elog about it then. This dawned on me only when I found that c1als isn't working the way it should right now.

mistake-cartoon.gif

  9068   Tue Aug 27 02:18:28 2013 JenneUpdateLSCPRMI, DRMI sensing matrices

I have made a measurement of the PRMI and the DRMI sensing matrices. 

Keiko pointed out to me in an email a little while ago that I wasn't zeroing elements in the oscillator drive matrix after using them, so I was effectively driving all the degrees of freedom at once, which is why some of the recent sensing matrices looked a little bullshitty.  Anyhow, I put in a few lines to zero that row of the LSC  output matrix, so that we don't do that any more. 

PRMI sensing matrix:

SensMatMeas_26Aug2013_withErrorBars.png

DRMI sensing matrix, first-ever measurement, after the optic flipping / recent locking success:

SensMatMeas_26Aug2013_DRMI_firstEverMeasurement.png

Note that we don't have any error bars in the DRMI case, since the IFO fell out of lock during the error bar measurements.  So, we got the "real" data from the degrees of freedom, but not extra data for making error bars.  Also, the MICH / SRCL coupling hasn't been balanced out in the output matrix yet, but since the notches are engaged in the degrees of freedom during this measurement, that shouldn't be a significant effect.

To get the DRMI sensing matrix measured, I added the SRM's actuator calibration to SensMatDefinitions.py (data from elog 5637).  I also created a new file runDRMI_sens, to be the equivalent of runPRMI_sens.  In the new runDRMI_sens, I reduced the actuation from the oscillator by a factor of 10.  I had several attempts at higher oscillator amplitudes that kept kicking the IFO out of lock.

The DRMI was pretty good, but I wasn't getting ~10s of minutes like Koji was on Friday.  I also wasn't able to engage all of the FM triggers that he was.  The 10-30 Hz seismic BLRMS is a little higher than a usual night, but other than that, seismic looks pretty quiet.

My settings for the night:

LSC input matrix:  +0.1*REFL55Q = MICH, -0.125*REFL11I = PRCL, +1.00*REFL55I = SRCL.

Filter settings:  MICH, PRCL, SRCL all had FM4,5 always on.  MICH had FM2,3 triggered.  PRCL had FM2,3,6 triggered.  SRCL had FM2 triggered.  In particular, engaging FM 6 for MICH or SRCL made some loud low-ish frequency oscillation.  Engaging anything other than FM2 for SRCL kicked the IFO out of lock. 

Gains:  MICH = -0.800, PRCL = +0.050, SRCL = -0.100

Triggering:  All triggered on POP22I, upper = 50, lower = 10 (lower = 25 for SRCL).

FM trigger thresholds: MICH on = 35, off = 2, delay = 2 sec.  PRCL on = 35, off = 2, delay = 0.5 seconds.  SRCL on = 80, off = 25, delay = 5 sec.

Power normalization:  None, for any degree of freedom.

LSC Output matrix:  MICH = -0.267 for PRM, +0.50 for BS.  PRCL = +1.0 for PRM.  SRCL = +1.0 for SRM. 

LSC SUS filters:  BS, PRM, SRM all had FM1,2,3,6 engaged for the BS, PRM and SRM violin filters, as well as the 3rd order harmonic for one of them.

Other notes: 

I tried locking the SRMI, so that I could do the same kind of actuator calibration that Koji did for the PRMI in elog 8816, but was unsuccessful.  I checked optickle, and found that for REFL 55 I&Q locking, MICH and SRCL keep the same signs for SRMI as DRMI.  Also, for both, the optical response is a factor of ~15 lower for SRMI than DRMI, so the gains should be higher by a factor of 15 for both MICH and SRCL.  I think my big problem here is that I don't have anything to trigger on.  There isn't any signal to speak of in the POP PDs, with the PRM misaligned.  Hopefully we'll have AS110 shortly, and that will help.

I updated the IFO Configure restore scripts to our latest versions of locking.  I have also tested them, and restoring the Michelson, PRMI and DRMI all seem to work. (MICH restores to locking with AS55Q.  PRMI restores to locking with REFL165 I&Q.  DRMI restores to the settings noted above in this entry.)  The X and Y arm restores have been working, and I have been using them (semi-)regularly since I announced them in elog 8433 back in April.  Still to-do though:  Add PRCL ASC to the PRMI up script, and make the dither options work for at least the arms and PRM.  (Just need to point the drop down menu options to the new ASS scripts.)

 

 

  9070   Tue Aug 27 15:44:08 2013 manasaUpdateCDSIssues with ALS fixed

I figured out the problem with ALS from yesterday. While the model was just fine, the medm screens were not checked if they were reading the correct channel names. 

The channel names of the ALS input matrix elements had changed when the coarse channels were deleted from the c1als model. So the error signals were not reaching the servo modules as expected. This is why I was not able to make sense as to what the ALS was doing. 

All is fixed now and should be back to normal

  9077   Wed Aug 28 00:41:23 2013 JenneUpdateCDSCDS svn commits not happening

svn status update. asx, als and ioo were found not committed. Not sure about who modified ioo last after Jenne.

//edit Manasa - edited the/ elog instead of replying //

  9078   Wed Aug 28 03:28:00 2013 JenneUpdateLSCPlaying with DRMI, some ASS automation prep

[Rana, Jenne]

We did lots of poking around with the DRMI tonight.  I should elog more in the morning, but the most important points are:

Locking settings same as elog 9068, except PRCL gain changed to 0.035, and the FMs that are triggered.  PRCL tonight had FM2,3,6 triggered.  MICH had FM1,2,3,7 triggered.  SRCL had FM1,2 triggered.  Engaging the MICH boosts helped make things more quiet, so that some of the SRC boosts could be enabled.  Still not as good of lock stretches as Koji got last Friday (elog 9060). 

REFL55 and REFL11 were still saturating (only during acquisition), after the optical path changes I did last week (elog 9043).  We reduced the REFL55 whitening slider from 15 dB to 6 dB (but forgot to compensate with digital gain), to keep the counts (as seen on DTT time series, binning off) to less than ~20,000 counts.  REFL11 is still saturating, and we're not sure why, since it's slider gain is 0 dB.  To be investigated.

I was prepping the ASS to be more conveniently put into a wrapper script, which could be called from the IFO Configure screen.  This involved adding PRCL to the burt .req and .snap files, as well as modifying the scripts a little bit to include PRCL as an option.  I ended up changing the script names from DITHER_Arm_ON.py and DITHER_Arm_OFF.py to DITHER_ASS_ON.py adn DITHER_ASS_OFF.py, since they are no longer restricted to being arms-only.  You must still provide an argument to the script, to tell it which degree of freedom you want to activate.  I also changed the save offsets scripts.  The way they were, the X and Y arms just had separate hard-coded scripts, with no convenient way to incorporate PRCL.  I merged them (including PRCL) into WRITE_ASS_OFFSETS.py, which you must now provide the DoF as an argument.  I tested these new scripts on all 3 of the DoFs, and made changes to the ASS screen, so it now calls only the new scripts.  It should now be easy to incorporate future ASS modifications.

Rana was in the middle of modifying the ASS model to include SRCL, and we also need to include MICH.  The ASS model is not compile-ready, so don't compile it!!  If you need to compile the ASS, please save what's there as a different name, and do an "svn up" to get the latest working version.


We suspected that there might be angular drive issues with the SRM (it was wiggling a lot). We checked the damping via step responses - all Qs were less than 10. Then we found that the INPUT button on the SRM PIT OL was OFF (why ???). After turning this back on it behaved better. We measured the loop shape and found that the UGF was 7 Hz; good. Need to work on some loop shaping for this guy. Its just 1/f out to 300 Hz right now. UGF should be made a little lower so that we can stably turn on the Bounce/Roll notches and a ~50 Hz low pass filter.

Most importantly, the F2A filters need to be measured and implemented. They are a few years old.

  9079   Wed Aug 28 05:21:58 2013 manasaUpdateCDSCDS svn commits not happening

I am responsible for missed svn commits with als and asx. I have committed them.

But I have not modified anything with ioo in the last few weeks.

 

  9080   Wed Aug 28 06:17:15 2013 manasaUpdateComputer Scripts / Programsalias for MATLAB2010

Although Matlab 2013 has not been causing any visible trouble so far, it takes a while to startup.

I have added alias 'ml10' to bash to start Matlab 2010 from the terminal for convenience.

  9081   Wed Aug 28 06:26:28 2013 manasaUpdateComputer Scripts / ProgramsASS req and snap files edited

[From yesterday] ASS for X arm was behaving slightly funny over the last couple of days. ASS could not correct the BS misalignment. Jenne pointed out that the LSC output matrix on the ASS medm screen set itself to zeroes whenever we ran the ASS_dither_ON script. I checked the burt request file: ASS_DITHER_ON.req  in /opt/rtcds/caltech/c1/scripts/ASS and found that the LSC output matrix channels were not added to it. I added these channels for both the X and Y arm. Following this, I also edited the corresponding snap file as well. This should now set the LSC matrix to the right values everytime we run the script.

  9082   Wed Aug 28 07:33:51 2013 manasaUpdateLSCMICH locking

I wanted to measure the OLTF of MICH.

What I did:
1. Ran LSC offsets script to zero all the offsets.

2. Restored the IFO configure settings for locking Michelson (locked on AS55Q).

3. MICH wouldn't lock on these settings.

4. The MICH servo was hitting its limits (10000 counts). I checked the filter module. After a little bit of looking into things, I disabled FM3 (0,0:5,5), FM4 (1:10) and FM7 (1:5). FM3 and FM7 were filter modules that were switched ON at the trigger. I set these to manual. Enabling any of the filters (FM3, FM4, FM7) caused MICH to lose lock.

5. MICH gain was changed from -20 to -30. MICH locked with ASDC suppressed to 0.01 counts. I looked at the power spectrum of C1:LSC-MICH_OUT on dtt. //edit: Manasa// The plot (uncalibrated) now shows MICH_OUT power spectrum with MICH PSL shutter closed, free-running MICH and loop-enabled MICH.

6. I then wanted to measure the OLTF of MICH using dtt. A channels were set to C1:LSC-MICH_IN1/C1:LSC-MICH_IN2 and excitation given through C1:LSC-MICH_EXC. But I have not been able to get any good coherence for the measurement as yet.

Attachment 1: MICH.pdf
MICH.pdf
  9083   Wed Aug 28 11:15:02 2013 SteveUpdateGreen LockingXend green layout corrections

Quote:

Quote:

 Shutter moved, no more clipping.

Pick-off mirror 2" replaced by 1" one. Laseroptik HR 532nm, incident angle 30-45 degrees, AR 532 nm

Green REFL PD moved to 4" close to pick-off mirror. Pd being close to pick-off does not separate multiple reflections on it. I'll replace Laseroptic mirror with Al one. It is not easy to find.

 Hole cut into side wall for doubler oven cable to exit.

 

 

 Beam trap for Pd refl is in place. Cabeling is ti·died up.

 Laseroptic 1" mirror is replaced by Al 1" mirror. Problem remains the same. This diffraction patter has to be coming from the Faraday.

  Atm1, good separation when Pd is far 

  Atm2, bad separation when Pd is close 

 The extra high post 3.375"  for PZT is ready. We also have 2 more 2" green Laseroptik mirrors. I'm ready to swap them in.

The  75 mm  focal length  lens  was placed in front of the green REFL PD yesterday.

  9084   Wed Aug 28 11:23:41 2013 SteveUpdateVACcrane repair sheduled

Quote:

 1, Vacuum envelope grounds must be connected all times!  After door removal reconnect both cables immediately.

 2, The crane folding had a new issue of getting cut as picture shows.

 3, Too much oplev light is scattered. This picture was taken just before we put on the heavy door.

 4, We were unprepared to hold the smaller side chamber door 29" od of the IOC

 5, Silicon bronze 1/2-13 nuts for chamber doors will be replaced. They are not smooth turning.

 

 Fred Goldbar of KoneCranes will come 7:30am Wednesday, September 4 to look at this issue.

It is changed to Thursday morning.

  9085   Wed Aug 28 15:41:42 2013 SteveUpdateVACRGA scan at day 23

 Valve configuration: Vacuum Normal

pd76-m-d23

 

Attachment 1: pd75md23.png
pd75md23.png
  9088   Thu Aug 29 17:25:50 2013 JamieUpdateSUSSUS medm screen upgrade

Rana asked me to look at the SUS MEDM screen upgrade situation, and provide an upgrade prescription.  Unfortunately there not really a simple prescription that can be used, since our configuration diverges quite a bit from what's at the sites.  But here's what I can say:

It looks like we already have the beginnings of an upgrade in place, so I say we just run with that.  The new screens are in:

/opt/rtcds/userapps/release/sus/c1/medm/new

The primary screen is:

/opt/rtcds/userapps/release/sus/c1/medm/new/OVERVIEW.adl

This seems to be a copy of the site ASC_TIPTILT screens.  (In fact I think I remember putting this here).  I went ahead and did some ground work to make it easier to get these new screens into place.

  • I cleaned up all the channel name prefixes so that at least the channel prefixes will resolve to our SUS channels.
  • I made a link from the sitemap with some of the correct macros to fill some things in appropriately: "IFO SUS/NEW ETMX"
  • I fixed the names to the sub-screens, so that it correctly opens the correct sub-screens (although the macros seem to not be passed correctly)

At this point someone needs to just go through and fix all the channel names to match ours, and tweak the screen to our needs (there's no side OSEM, for instance).  The subscreens need to be cleaned up as well.

sed replace string

If there is a specific string you want to replace every instance of in the screen, you can do that easily from the command line like this:

sed -i 's/OLD/NEW/g'  

This will replace every instance of the string OLD with the string new in the file path/to/file.  Be careful: this will replace EVERY instance of OLD.  If OLD matches things you don't want, they will be replaced as well.

This construction is actually "regular expressions", so if you want to get fancy you can match against more complicated strings.  But just be careful.

If you leave out the "-i" the string-replaced text will go to stdout, instead of being replaced in the file "in place", so you can check it first.

query replace in emacs

If you want more fine-grained control of text replace, so that you can see what's being replaced, try using "query-replace" in emacs:

M-x query-replace

You can then type in the original string, followed by the replacement string.  When it starts to run it will highlight the string that will be replaced.  Hit "space" to accept or "n" to skip and go to the next.

 

 

  9090   Fri Aug 30 08:08:29 2013 steveUpdatesafetyfire horns-flashers tested OK

 

 We had fire alarm tests  and evacuation drills at 1:30pm yesterday. All flashers and horns are functioning unbearably loud and bright including clean assembly room.

  9091   Fri Aug 30 11:00:46 2013 ManasaUpdateGeneralSeries of earthquakes

There has been a series of earthquakes since the big 7.0 in Alaska this morning.

None of the watchdogs were tripped when I came in. But I could not retrieve any info about the suspensions from fast channels because c1sus was not talking to the fb and that required an mxstream restart to fix it.

MC is trying to lock itself, but the seismic doesn't seem to get quiet. So MC is not all that happy.

 Screenshot-Earthquakes_-_Mozilla_Firefox.png

SUSnSEIS.png

  9092   Fri Aug 30 14:31:57 2013 SteveUpdateGeneralcleaning up

I cleaned up around MC2 and 1Y1 area this morning.

ETMY NPRO moved from the side to the center of the low shelf. Thorlab catalog " as spacer " removed after lunch.

The Lightwave Controller values: LT 40.4C,  LTEC +0.1V,  T 41.041C,  Pwr 239 mW,  Adj 0,  DC 1.82A,  DPM  0.0V,  Neon OFF,  Ldon OFF,  Display 5,  DT 21.0C,  Dtec +1.0V

 

Attachment 1: MC2areaCP.jpg
MC2areaCP.jpg
Attachment 2: 1Y1areaCleanedUp.jpg
1Y1areaCleanedUp.jpg
Attachment 3: ETMY_NPROmoved.jpg
ETMY_NPROmoved.jpg
  9094   Mon Sep 2 15:22:57 2013 JenneUpdatePSLPMC relocked

 The PMC was locked on an LG 10 mode (or something like it), for at least the last 8 hours.  I relocked it on the regular 00 mode, and it's fine now.  

Also, in CDS news, I did an mxstream restart (the RCG upgrade is supposed to make this not an issue anymore...), and did a "diag reset" afterwards, and all of the IPC errors except for one in the LSC model have gone away (OAF is still not running....on my to-do list, but not super high priority).

  9095   Mon Sep 2 16:46:32 2013 JenneUpdateElectronicsRF distribution box is on the bench

I have pulled the RF distribution box out of the rack, so I can look at it, and modify it to have 2 110 MHz spigots. I'm going to make the mods as in elog 9072.

Before I pulled the distribution box, I turned off the RF Generation Box, so don't be surprised that the MC will not lock.  I have terminated the cables that bring the 11 and 55 MHz signals from the generation box to the distribution box, so if someone does turn on the generation box, there won't be bad reflections.

To get the box out, in addition to unplugging all of the cables that go to the distribution box, I had to disconnect 2 of the ADC ribbon cables from the top row of RFPD demod / whitening / ADC boards, since they were in the way.  Everything is labeled, so it should be easy to put back together.

Note to Future Jenne:  Past Jenne put the screws needed for those ADC cables and to hold the box in the rack, in the plastic box that is on the floor in front of the LSC rack. 

Also, I measured the 110 MHz port before I pulled the board, so I would know what my "before" looked like.  I was using the 300MHz 'scope's measurement functions, so these are in volts, not dBm.  Amplitude = 1.33V, RMS = 456 mV, freq = 109.4-111.9 MHz

  9096   Mon Sep 2 18:06:21 2013 JenneUpdateElectronicsRF distribution box: 110 MHz LO options

After scrounging for parts, and opening up the box, I have modified my proposal to the following:

RF_distribution_box_proposed_modifications.pdf

Note that the freq multiplier is supposed to take, at maximum, 15 dBm.  The reason I put the 5 dB attenuator, then an amplifier, then another attenuator is that I don't know of / can't find easily a 10 dB amplifier with the usual case type on the MiniCircuits site.  (If anyone knows of one off the top of their head, that would be handy.  Then I'd remove the attenuator between the multiplier and the amplifier, and make the 10 dB attenuator a 5 dB.)

Anyhow, the ZFL-500HLN can only output 16 dBm of power, and I don't think I have space for another ZHL-2 (which can output up to 26 dBm) inside the box, so I put an attenuator before, as well as after, the amplifier. 

I think I have space inside the box for all the bits and pieces I'll need, although to do things correctly, I need to drill holes in the teflon mounting plate to mount the amplifier and splitter.

0902131751.jpg

I also think that I have space on the front panel to put another isolated SMA feedthrough.

0902131751a.jpg

I have, on my desk, all the parts (except for mounting screws, and cables between things) to make these modifications to the distribution box. 

  9098   Tue Sep 3 14:23:21 2013 SteveUpdatePEM earthquakes

 ~Vancuver, Canada earthquakes: magnitude 6,  5  and more shaking

 

Attachment 1: EQm6&5.png
EQm6&5.png
  9099   Tue Sep 3 21:08:13 2013 JenneUpdateElectronicsRF distribution box: 110 MHz LO options

The RF distribution box is still on the bench, so again, don't be surprised that the MC doesn't lock.

I have completed my modifications as proposed in elog 9096, but I want to do a couple of quickie tests in the morning before I declare it ready for service.

  9101   Wed Sep 4 16:06:40 2013 JenneUpdateElectronicsRF distribution box: Reinstalled

I have reinstalled the RF distribution box, as well put in the AS110 demod board.  I plugged everything back in, and turned it all on.

The switch on the distribution box may be starting to fail.  When I was turning the box on, I could depress the button, and see the blue glow, but it wouldn't catch, so when I removed my finger, the glow went away.  I was afraid that I'd have to pull the box, but after a few more button toggles, I got it to stay on.  I'm leaving it for now, but we should remember that this may be a problem.

I will look at the phases of all the PDs, but none should need changing except POP 110.  Every other PD has the exact same cables as before.

  9102   Wed Sep 4 16:08:22 2013 manasaUpdateSUSMC2 tickler turned OFF

 [Jenne, Manasa]

While we were trying to relock the MC after Jenne put back the RF box, we found there was some mysterious motion in MC2. After spending time trying to figure out where this was coming from, the source was found to be at LOCKIN2 of MC2 suspension "The MC TICKLERthat was left enabled. This was turned OFF and MC locked just fine after that.

 

EDIT JCD:  The Tickler should be disabled, if the autolocker is disabled.

  9103   Wed Sep 4 17:22:09 2013 JenneUpdateLSCDemod phases for RFPDs

I checked the demod phases for AS55, POP110, and all the REFL PDs. 

AS55:  I locked MICH, and shook the ITMs (+1 for Y, -1 for X), and watched the AS55 I & Q spectra at 580Hz (notch in the servo was enabled).  I rotated the phase from -32.0 to +13.0 to get the signal entirely in the Q phase.

POP110:  I locked the PRMI (triggering on POP22), and maximized POP22.  I then rotated the phase of POP110 until the signal was maximally positive.  I forgot what the starting phase was, but it is now 84.  The POP11_I signal was entirely negative when I started, so the new phase is about 180 from the old phase.  I also checked by unlocking the cavity, and seeing that a large peak in POPDC corresponded to large negative dips in POP110_I and POP22_I.

REFL PDs:  I locked the PRMI, and shook the PRM (notches in the servos were enabled for both MICH and PRCL).  Maximized the peak in the I phase.  REFL11 was fine, REFL33 was fine.  REFL55 was changed from 120 to 45.  REFL165 was changed from 106 to 96.

I restored the SRM on the IFO_ALIGN screen, but the saved value was almost 2 full integers off in yaw from actual DRMI resonances.  It looks like it was saved when Rana and I were working late last week.  We must have accidentally saved it when it was misaligned, since hysteresis can't do that much.

I want to check the phases for POX and POY with arm locking, just in case.  Also need to set the AS110 phase (which is plugged into the AS11 channels - need to fix the channel names).

 

  9104   Wed Sep 4 20:39:23 2013 ranaUpdateSUSMC2 tickler turned OFF

Quote:

 [Jenne, Manasa]

While we were trying to relock the MC after Jenne put back the RF box, we found there was some mysterious motion in MC2. After spending time trying to figure out where this was coming from, the source was found to be at LOCKIN2 of MC2 suspension "The MC TICKLERthat was left enabled. This was turned OFF and MC locked just fine after that.

 

EDIT JCD:  The Tickler should be disabled, if the autolocker is disabled.

 Sounds like this was just incidental, since the MC locked fine also with the tickler enabled for weeks.

The tickle is disabled by the down script, but there's no way to correctly handle all possible button pushes. If you want to disable the autolocker for some reason you should run mcdown before trying to lock. This will set up things with the correct settings.

  9105   Wed Sep 4 20:47:15 2013 manasaUpdateLSCCalibrated in-loop MICH noise

To estimate in-loop MICH noise:

(a) Calibrate MICH_ERR:

1. Lock the arms for IR using POX11 and POY11.
2. Misalign the ETMs.
3. Obtain the average peak-to peak (bright to dark fringe) counts from the time series of AS55_Q_ERR. I measured this to be d = 6.358 counts.
4. This gives the calibration factor for AS55_Q_ERR [Calibration factor = 2*pi*d/1064/10^-9 = 3.7546x10^7 counts/m]

(b) In-loop MICH noise:

1. Lock MICH using AS55_Q.
2. Since LSC input matrix sets MICH_IN1 = 1* AS55_Q_ERR, the power spectrum measured using dtt and calibrated using the calibration factor from step 4 in (a) gives us the calibrated in-loop MICH noise.

The plot below shows the in-loop MICH noise and the dark noise (measured by closing the PSL shutter):

Compared with old measurements done by Keiko elog 6385 the noise levels are much better in the low frequency region below 100 Hz.
(No, no, no... this is not an apple-to-apple comparison: KA)

Attachment 1: MICH_noise.pdf
MICH_noise.pdf
  9106   Wed Sep 4 21:44:54 2013 Not JenneUpdateElectronicsRF distribution box: Reinstalled

Temporary fix for the switch: give a bit of oil to the button

Permanent fix: buy better switches.

  9107   Wed Sep 4 22:14:35 2013 JenneUpdateSUSMC2 tickler turned OFF

Quote:

 

 Sounds like this was just incidental, since the MC locked fine also with the tickler enabled for weeks.

The tickle is disabled by the down script, but there's no way to correctly handle all possible button pushes. If you want to disable the autolocker for some reason you should run mcdown before trying to lock. This will set up things with the correct settings.

 Isn't that backwards?  Shouldn't the tickler be enabled by the down script, and disabled by the up script?  Either way, the problem was that, after I acquired lock, the tickler was causing the transmitted power to fluctuate by ~20%, and often the MC would lose lock after a minute or so.  Also, the WFS definitely couldn't be enabled by hand. 

Anyhow, I'll try to keep in mind that this exists, so I'm not stymied by it again.

  9108   Thu Sep 5 00:40:33 2013 ranaUpdateSUSMC2 tickler turned OFF

 

 You're right - down turns it on. Still, the fact that the same tickle recently causes a problem and didn't make 20% power fluctuations until now tells me that its not that the tickle amplitude is too large. Whatever changed recently is the problem.

  9109   Thu Sep 5 01:55:29 2013 JenneUpdateLSCLSC model upated to have AS110 channels, violin filter triggering

I have modified the c1lsc model so that I have access to the AS110 channels in the triggering and power normalization matrices. 

I also put in a few blocks so that we can have triggering on the violin notches that we moved to the LSC model a week or so ago. 

Here is my svn comment, so I don't have to retype things:

2 changes:  AS110 channels added, and Violin filter triggers added.

AS110:     We recently installed a    new demod board    and PD for an AS110 signal.  Since we will not    be using AS11 in the forseeable    future,    the AS110 demod    board outputs use the former AS11 channels.  I    have left the AS11 channels in the model so that we can easily    add them back if we want to, but they are grounded rather than    connected to the ADC.  I've added digital demodulation for AS110, power normalization,    and then added the I&Q signals to both the trigger matrix and the main    power normalization matrix.  NOTE that these slide the matrix columns around.    Since the AS110    is also    using the former AS11 whitening    channels, swapped those on the    BIO block also.

Violins:  Recently, Rana and I moved the SUS LSC violin    filters    from the individual suspension    models over to the LSC model.  Giving every optic every    optics' violin    notch helps eliminate bad cross-coupling between servo loops.  Here, I have enabled triggering    for these notches, so that the violin filters can come on after a cavity is locked.  Since the    filter banks SHOULD BE THE SAME    for all LSC_SUS banks,    the "mask" is common to    all optics.

I also edited several medm screens, to show the new changes:  the lsc overview screen has a button to the violin notch triggering screen, in addition to being able to get to the new screen from the regular triggering matrix screen.  I made the trigger and normalization matrix screens bigger, since there are now 2 new columns. 

I added AS110 to both the LSCoffsets script, and Masayuki's new, better, LSCoffsets2.py. 

I added new lines to the .req files for the ifo configure burt restores for the new matrix columns, and the violin triggering.

I restored, checked out, and saved the Xarm, Yarm, MICH, PRM_sb, and DRM configurations. 

 


I tried locking the DRMI, but haven't really been successful.  I'm not 100% sure how to do the phasing for AS110, so that could be a problem.  For POP, I can watch POPDC to see if something is a carrier or a sideband flash, but I don't have something quite as convenient at the AS port.  I have set the AS110 phase to 60 degrees for now, since during free swinging DRMI flashes, it looks like most of the buildup is in the I phase with 60 degrees.  Even with the same configurations as a week or so ago, I'm not getting much more than ~1 second locks.

I also tried locking the SRMI, but am not getting anything at all.  I think I need to go back to simulation-land to figure out what good signals might be.

 


Other thoughts:

Stefan modified the LSC filter module triggering blocks, so now we have a new epics variable, "_INVERT", which sends the trigger through a NOT or not.  I think that we want to keep this variable set to 0 to be the same as things were, but I do need to expose this new variable on the screens.

The trigger and normalization matrices pictured on the LSC overview screen need to be expanded by the 2 new columns.  The actual matrix screens are good, but I forgot to fix up the little Kissel buttons.

When I have a free swinging SRMI, MICH and SRCL should have the same sign for the gain, if I'm using AS55 I&Q for locking.

LLO is using REFL 9I for SRCL, and ASDC for MICH for the SRMI, but I don't have any REFL beam with a misaligned PRM, so I don't think I can copy what Den and Lisa did on Monday night.

I have figured out / rediscovered why the "sqrt" buttons on the power normalization screen aren't restored when you restart the LSC model - They are controlled by momentary epics records, which go to embedded c-code to do some toggling.  I don't know yet of a good way to save the configuration of these guys for burt restore-type restoration.  This will be a problem for anything that is using these toggle c-codes.

  9110   Thu Sep 5 10:28:17 2013 SteveUpdateSUSPRM side

I think the crane repair guy accidentally  stepped on the  BSC support beam.

PRM side is not coming down.

Attachment 1: craneguywashere.png
craneguywashere.png
  9111   Thu Sep 5 10:47:58 2013 SteveUpdateVACvertex crane folding issue

 

 [Fred Goldbar, Mike Gerfen, Dennis Coyne and Steve]

We inspected the hinge, 1.25" cross pin and I-beams. It is hard to explain what is  causing the folding I-beam corner to jam against the main I-beam.

To limit the motion of the folding I-beam  cross pin bushing will be added. This will take a week to complete.

 

 

 

 

 

Attachment 1: 5mmLess.jpg
5mmLess.jpg
  9112   Thu Sep 5 11:19:33 2013 JenneUpdateSUSPRM side

Quote:

I think the crane repair guy accidentally  stepped on the  BS support beam.

PRM side is not coming down.

 Seems fine now.

  9113   Thu Sep 5 15:18:41 2013 JenneUpdateLSCFree swinging DRMI power buildups

I have the DRMI free swinging right now, since it's not really locking.  Looking at these time series in the attached pdf, particularly around time=1.15, it would be super handy to trigger the SRCL degree of freedom on AS110 after the PRMI is triggered on POP22.

Attachment 1: DRMI_free_swing_power_buildups.pdf
DRMI_free_swing_power_buildups.pdf
  9114   Thu Sep 5 21:07:09 2013 JenneUpdateLSCStarted work on logic for triggering

I want something like an "AND" for the degree of freedom triggers.  Koji and I talked through an idea, and I have it running in the c1tst model, but the logic isn't working like I expect, so I need to look into it more before I can put it into the lsc model.

  9115   Fri Sep 6 09:27:10 2013 SteveUpdateVAC31 days after pumpdown

Quote:

 Valve configuration: Vacuum Normal

 

 

Attachment 1: day31vac.png
day31vac.png
  9116   Fri Sep 6 23:01:08 2013 KojiUpdateLSCStable DRMI lock was recovered from the impact on the RF system modification

Summary

Stable DRMI lock was recovered. The AS110 phase was adjusted. PRCL and MICH were locked with REFL33I and REFL165Q.
Still SRCL is controlled with REFL55Q.


PRMI sensing matrix

Thursday night, Jenne and I found DRMI can not be locked at all. Also the PRMI lock with REFL55 showed change in the optical gain.

In order to investigate what is happening, the PRMI sensing matrix was measured and compared with the previous one taken in the night of 8/26.

SensMat_PRMI_1000cts_580Hz_2013-08-26_235635.pngVSSensMat_PRMI_1000cts_580Hz_2013-09-06_201137.png

It shows that some signals are unchanged, some are partial change, and some are completely different.
My intuition saids something is wierd with the sensing matrix measurement.
Right now I can't trust these plots.

- Jenne and I have adjusted REFL55 demod angle so that REFL55Q has no PRCL. And I have confirmed with DTT that this is still true.
  However, the radar chart shows that REFL55Q is almost correct phase for PRCL instead of MICH.

- REFL11 shows the same amplitude and angle as before. But POX11/POY11 shows different MICH angle.

- I have rotated REFL55 demod phase and remearsured the sensing matrix. Evrything else looked same but REFL55.
  Since REFL55I&Q were not used for the control for this measurement, what we expect is to see no change of the sensing matrix and
  only see the angle of "I"&"Q" rotates. But the result was different from the expectation.

DRMI locking

Since no real info was obtained from the sensing matrix, I had to make a fight without any weapon.
After sevral hours of work, stable DRMI lock was recovered.

Basically I gave larger gains to REFL55 signals: REFL55I for SRCL was 100 instead of 1, and REFL55Q for MICH was 2 instead of 0.1.
This was enough to get a second locking. Using this short sections, I have optimized the FM triggers and the gain boosts (i.e. FM1)
as well as the mirror alignment.

Then, PRM ASS was left running during the lock. This actually stabilized the lock a lot.
This made thee lock indefinite.

The demod phase of AS110I was adjusted so that AS110Q fluctuates around zero.
In this condition, the nominal AS110I was 7300 with the whitening gain of 30dB.

Note that the AS110I&Q were also measured with PRMI. With the same phase and gains, AS110I and Q were -35,  -170, respectively.
Do we expect to have this phase shift? If I believe these numbers, the aplitude of 110MHz at the optimal phase is 173,
The ratio of AS110 between DRMI and PRMI is 7300/173 = 42. This corresponds to the ratio of the 110MHz sideband power at the AS port.
According to the wiki, this ratio shoud be ~160.

AS110I was in fact glitchy as you can see in the StripTool chart. I wonder this signal is suitable for the normalization or not.


=== SENSING ===

REFL11 -67deg / whitening gain 0dB
REFL33 -20deg / whitening gain 30dB
REFL55 45deg / whitening gain 6dB
REFL165 96deg / whitening gain 45dB

POP110 69deg whitening on / 15dB
POP22 102.2deg whitening on / 21dB
AS110 145deg whitening off / 30dB (seems to be related to AS11 whitening setting)

=== INPUT MATRIX ===

REFL11I x -0.125 => PRCL (REFL33I x 2.5 was also OK)
REFL55I x 100 => SRCL
REFL55Q x 2 => MICH (REFL165Q x 0.1 was also OK)

=== NORMALIZATION / TRIGGER ===

No normalization

Trigger settings
MICH POP22I UP:50 DOWN:10
PRCL POP22I UP:50 DOWN:10
SRCL POP22I UP:50 DOWN:25

=== SERVO FILTERS ===

MICH x -0.8 FM4/5 ON, no limitter
FM Trigger: delay 2sec, FM1 (modified from 6dB to 20dB), FM2, FM3

PRCL x +0.035 FM4/5 ON, no limitter
FM Trigger: delay 0.5sec, FM2/3/6

SRCL x -0.1 FM4/5 ON, no limitter
FM Trigger: delay 5sec, FM1, FM2

=== OUTPUT FILTERS ===

MICH => PRM -0.267 / BS +0.5

PRCL => PRM +1.0

SRCL => SRM +1.0

=== VIOLIN FILTER TRIGGER ===

delay 1sec: FM1/FM2/FM3/FM6

=== ASC/ASS ===

PRM ASC UP:50 DOWN:25
PITCH&YAW: FM1/9 (ALWAYS ON) + FM2/3 (turned on by the up-script)

PRM ASS left turned on for slow tracking

Attachment 1: DRMI.png
DRMI.png
  9117   Mon Sep 9 15:33:06 2013 SteveUpdateVACvertex crane repair is scheduled

Quote:

 

 [Fred Goldbar, Mike Gerfen, Dennis Coyne and Steve]

We inspected the hinge, 1.25" cross pin and I-beams. It is hard to explain what is  causing the folding I-beam corner to jam against the main I-beam.

To limit the motion of the folding I-beam  cross pin bushing will be added. This will take a week to complete.

 

 

 

 

 

 KoneCrane contact John McDaniel (562) 903 - 1371,

Wednesday, September 18,  folding I-beam will be removed.  KoneCrane will start working at 7:30am and they should be out by 12:30pm

 Friday,  September 20, reinstalling machined hinge on the I-beam. Same timing schedule as Wednesday.

  9118   Mon Sep 9 20:46:28 2013 MasayukiUpdateLSCMICH calbration

[Manasa, Masayuki]

We took a bunch of measurements. Transfer function and power spectrum using DTT. They will be used to obtain calibrated MICH in-loop and free-running noise. Detail Elog with plots will follow very soon.

ELOG V3.1.3-